  4. [SOLVED] How do I: delay a notification to fire only if the ruleset actually fires
Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor

[SOLVED] How do I: delay a notification to fire only if the ruleset actually fires

Scheduled Pinned Locked Moved Multi-System Reactor
reactionsdelays
17 Posts 4 Posters 843 Views 4 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • G gwp1

    @toggledbits I had a delay in it originally and all that did was delay the notification even if the ruleset ended up not ultimately firing because conditions changed and the Set Reaction didn't need to be fired - ie, I still got the notification (albeit delayed) even if the ruleset was aborted because the Triggers no longer applied.

    toggledbitsT Offline
    toggledbitsT Offline
    toggledbits
    wrote on last edited by
    #8

    @gwp1 said in How do I: delay a notification to fire only if the ruleset actually fires:

    even if the ruleset was aborted because the Triggers no longer applied.

    That is correct behavior. You can get the reaction to stop if the rule resets by supplying a Reset Reaction. If the Reset Reaction is not empty, Reactor will abort the running Set Reaction. It can even contain just a comment (so not actually do anything); as long as it's not empty, Reactor will abort the delay and everything that follows it.

    Documentation: Reaction Delays

    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

    G 2 Replies Last reply
    0
    • toggledbitsT toggledbits

      @gwp1 said in How do I: delay a notification to fire only if the ruleset actually fires:

      even if the ruleset was aborted because the Triggers no longer applied.

      That is correct behavior. You can get the reaction to stop if the rule resets by supplying a Reset Reaction. If the Reset Reaction is not empty, Reactor will abort the running Set Reaction. It can even contain just a comment (so not actually do anything); as long as it's not empty, Reactor will abort the delay and everything that follows it.

      Documentation: Reaction Delays

      G Offline
      G Offline
      gwp1
      wrote on last edited by
      #9

      @toggledbits said in How do I: delay a notification to fire only if the ruleset actually fires:

      You can get the reaction to stop if the rule resets by supplying a Reset Reaction. If the Reset Reaction is not empty, Reactor will abort the running Set Reaction. It can even contain just a comment (so not actually do anything); as long as it's not empty, Reactor will abort the delay and everything that follows it.

      Wow, I never would have considered that, not in a million years. Thanks, Teach!

      *Hubitat C-7 2.4.1.151
      *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

      *HASS 2025.3.4
      w/ ZST10-700 fw 7.18.3

      *Prod MSR in docker/portainer
      MSR: latest-25082-3c348de6
      MQTTController: 24257
      ZWave Controller: 25082

      toggledbitsT 1 Reply Last reply
      0
      • G gwp1

        @toggledbits said in How do I: delay a notification to fire only if the ruleset actually fires:

        You can get the reaction to stop if the rule resets by supplying a Reset Reaction. If the Reset Reaction is not empty, Reactor will abort the running Set Reaction. It can even contain just a comment (so not actually do anything); as long as it's not empty, Reactor will abort the delay and everything that follows it.

        Wow, I never would have considered that, not in a million years. Thanks, Teach!

        toggledbitsT Offline
        toggledbitsT Offline
        toggledbits
        wrote on last edited by
        #10

        @gwp1 said in How do I: delay a notification to fire only if the ruleset actually fires:

        Wow, I never would have considered that, not in a million years.

        Well, there's a place you can go (and it's not here) that will tell you this and many similar secrets... 😉

        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

        G 1 Reply Last reply
        0
        • toggledbitsT toggledbits

          @gwp1 said in How do I: delay a notification to fire only if the ruleset actually fires:

          Wow, I never would have considered that, not in a million years.

          Well, there's a place you can go (and it's not here) that will tell you this and many similar secrets... 😉

          G Offline
          G Offline
          gwp1
          wrote on last edited by
          #11

          @toggledbits I certainly hope you aren't pointing to the MANUAL! Next thing, you'll want me asking directions before embarking on an excursion from the house!

          *Hubitat C-7 2.4.1.151
          *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

          *HASS 2025.3.4
          w/ ZST10-700 fw 7.18.3

          *Prod MSR in docker/portainer
          MSR: latest-25082-3c348de6
          MQTTController: 24257
          ZWave Controller: 25082

          1 Reply Last reply
          1
          • toggledbitsT toggledbits

            @gwp1 said in How do I: delay a notification to fire only if the ruleset actually fires:

            even if the ruleset was aborted because the Triggers no longer applied.

            That is correct behavior. You can get the reaction to stop if the rule resets by supplying a Reset Reaction. If the Reset Reaction is not empty, Reactor will abort the running Set Reaction. It can even contain just a comment (so not actually do anything); as long as it's not empty, Reactor will abort the delay and everything that follows it.

            Documentation: Reaction Delays

            G Offline
            G Offline
            gwp1
            wrote on last edited by
            #12

            @toggledbits said in [SOLVED] How do I: delay a notification to fire only if the ruleset actually fires:

            You can get the reaction to stop if the rule resets by supplying a Reset Reaction. If the Reset Reaction is not empty, Reactor will abort the running Set Reaction. It can even contain just a comment (so not actually do anything); as long as it's not empty, Reactor will abort the delay and everything that follows it.

            Documentation: Reaction Delays

            This functionality has stopped working as of build 21331 (and the subsequent 21332) from my observations.

            Screen Shot 2021-11-28 at 9.17.29 PM.png

            Screen Shot 2021-11-28 at 9.17.50 PM.png

            (Yes, I literally c/p'd your explanation into the Comment field so I'd know why I created that particular Reset Reaction.) The current behaviour is how one would expect it to respond if the Reset Reaction were empty. I don't have logs pulled yet, sleep for work tomorrow beckons but I wanted to put it on the proverbial radar. If this should be reported in Mantis I'm happy to do so, just may be a couple days what with Giving Tuesday this week.

            *Hubitat C-7 2.4.1.151
            *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

            *HASS 2025.3.4
            w/ ZST10-700 fw 7.18.3

            *Prod MSR in docker/portainer
            MSR: latest-25082-3c348de6
            MQTTController: 24257
            ZWave Controller: 25082

            1 Reply Last reply
            1
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by
              #13

              I have a pretty short and definitive test for this, and it's working as expected. There have been no code changes in this area, so I'd be surprised to see a change in behavior.

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              0
              • A Offline
                A Offline
                Alan_F
                wrote on last edited by
                #14

                I've re-read this thread a few times and still am confused by the whole thing. If I understand the images of the rule set, the notification should not be sent because this entire rule set doesn't become true unless one of the conditions is sustained for 420 seconds. That notification should never fire earlier than 420 seconds after one of the Thermostat.Setpoint <> XX is first detected. There is no issue of stopping a running rule set. This rule set isn't supposed to run unless the error state is sustained for 420 seconds. I have several rule sets that work just like this, and they work as expected. Nothing happens if the mis-matched conditions are corrected before the 'sustained for' time expires.

                Light bulb moment: I think I just figured why this may be firing the notification when you don't want it to.

                Existing conditions:
                Downstairs set point is 62. it has been set to 62 for more than 420 seconds.
                Downstairs mode is set to heat.
                Armed for heating master rule set is true
                House mode switches from 'away' to 'home'.

                This rule set will fire immediately.

                This would also occur if the Armed for heating master rule set changed to true, or if the downstairs thermostat mode changed to heat. As long as the thermostat has been set to something other than 65 or 68 for 420 seconds prior to those other conditions coming true, the 'delay' (really 'sustained for') is already met.

                This either needs to be wrapped in an outer group with a 'sustained for 420 seconds' on the whole thing, or the house mode, armed for heating master, and thermostat mode conditions also need to be set to only go true when they are sustained for 420 seconds.

                I'm not sure I understand your use case, but if it's possible for the set point to be other than 65/68 and one of those other conditions to then change, this could definitely be double-running your HVAC - Heating Day reaction. If, for example, you have a reduced set point when you're in away mode (or at night), and the HVAC - Heating Day reaction is supposed to fire when you come home (or switch to day mode), then this rule will fire at the same time, assuming you've been away more than 420 seconds (or in night mode more than 420 seconds) with the set points turned down.

                If this really does involve an already-running reaction that needs to be stopped by a reset reaction, then I'm completely misunderstanding how the rules in the images you posted work.

                G 1 Reply Last reply
                0
                • A Alan_F

                  I've re-read this thread a few times and still am confused by the whole thing. If I understand the images of the rule set, the notification should not be sent because this entire rule set doesn't become true unless one of the conditions is sustained for 420 seconds. That notification should never fire earlier than 420 seconds after one of the Thermostat.Setpoint <> XX is first detected. There is no issue of stopping a running rule set. This rule set isn't supposed to run unless the error state is sustained for 420 seconds. I have several rule sets that work just like this, and they work as expected. Nothing happens if the mis-matched conditions are corrected before the 'sustained for' time expires.

                  Light bulb moment: I think I just figured why this may be firing the notification when you don't want it to.

                  Existing conditions:
                  Downstairs set point is 62. it has been set to 62 for more than 420 seconds.
                  Downstairs mode is set to heat.
                  Armed for heating master rule set is true
                  House mode switches from 'away' to 'home'.

                  This rule set will fire immediately.

                  This would also occur if the Armed for heating master rule set changed to true, or if the downstairs thermostat mode changed to heat. As long as the thermostat has been set to something other than 65 or 68 for 420 seconds prior to those other conditions coming true, the 'delay' (really 'sustained for') is already met.

                  This either needs to be wrapped in an outer group with a 'sustained for 420 seconds' on the whole thing, or the house mode, armed for heating master, and thermostat mode conditions also need to be set to only go true when they are sustained for 420 seconds.

                  I'm not sure I understand your use case, but if it's possible for the set point to be other than 65/68 and one of those other conditions to then change, this could definitely be double-running your HVAC - Heating Day reaction. If, for example, you have a reduced set point when you're in away mode (or at night), and the HVAC - Heating Day reaction is supposed to fire when you come home (or switch to day mode), then this rule will fire at the same time, assuming you've been away more than 420 seconds (or in night mode more than 420 seconds) with the set points turned down.

                  If this really does involve an already-running reaction that needs to be stopped by a reset reaction, then I'm completely misunderstanding how the rules in the images you posted work.

                  G Offline
                  G Offline
                  gwp1
                  wrote on last edited by
                  #15

                  @alan_f The goal here is, for those times when Honeywell flakes on accepting the API post to change temps, this will monitor that and, if the expected setpoints aren't met for the specified conditions (ie, Heating at Home, Heating Away, etc.) then it will resend the commands to Honeywell. The reason for the 420 second delay is to allow the Honeywell API to "compose itself" since it's easily overrun and sending the course correction immediately will presumably result in no correction happening.

                  @toggledbits I'm at a bit of a loss, then. Nothing was touched with this ruleset since I added the Reset Reaction and it resolved this issue originally. What is the test you have for this and can I use it to spin up a temp rule and validate locally?

                  *Hubitat C-7 2.4.1.151
                  *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                  *HASS 2025.3.4
                  w/ ZST10-700 fw 7.18.3

                  *Prod MSR in docker/portainer
                  MSR: latest-25082-3c348de6
                  MQTTController: 24257
                  ZWave Controller: 25082

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by toggledbits
                    #16

                    I think there's a misunderstanding here, and you need to review your logic and the state of devices in the detail panel for the rule, which shows the status of the condition targets and each condition as well as the running timers (when running).

                    A Reset reaction can only stop a running Set reaction. There is no delay in your Set reaction, so your Set reaction will run instantly and completely when the trigger conditions are met. There is no opportunity here, based on what I see from what is posted earlier, for the Reset reaction to intervene. That whole issue is moot as it applies to the rule and reaction shown.

                    The sustained for delay is self-cancelling. When the related condition is no longer met (i.e. result is false), the timer is cancelled. If this rule is setting, it is doing so because one of the two conditions is being met. A review of the detail panel and status will show this.

                    I"m getting the idea that you are not looking at the detail panel. Go look at it. Post it if the results aren't what you expect.

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    1 Reply Last reply
                    0
                    • A Offline
                      A Offline
                      Alan_F
                      wrote on last edited by Alan_F
                      #17

                      @gwp1 I think I correctly understood the use case then. The issue is that your rule set doesn't start counting the 420 seconds when the initial command is sent to the Honeywell API. The 420 seconds starts counting as soon as the setpoint is <> 65 (or 68). If you ever have the thermostats set to another value (when away, or night, or when not in heat mode) then the 'sustained for' will start counting and as soon as 420 seconds have passed, that element of the rule will go to true. You'll see it is green in the detail panel if you expand the rule set.

                      The thing I'm not clear on, but am making some assumptions about, is what triggers the initial call to the Honeywell API that this rule is designed to monitor/verify. Making the assumption that you turn down the thermostat at night with something like "HVAC - Heating NIGHT", and that heating is still armed and the thermostat mode is still set to heat at night, then 420 seconds after you go into night mode, every element of this rule set will be true except the Hubitat house mode rule. The rule set is primed to activate if that goes true.

                      So at night:

                      • Armed for heating is true
                      • (7 minutes after you enter night mode) Set point has been at some other value for more than 420 seconds
                      • Thermostat mode is set to heat
                      • But the rule set is NOT activated because the "AND house mode not in (night, vacation, away)" is not true

                      In the morning when the Hubitat mode switches from "night" to "day", this rule will go true immediately as all elements are now true.

                      • Armed for heating is true
                      • Set point has been at some other value for more than 420 seconds. It is still at the night value until the API reports the new daytime value
                      • Thermostat mode is set to heat
                      • House mode not in (night, vacation, away)" is true

                      If you add the 420 second 'sustained' to the other elements, then in the morning when the Hubitat mode switches to "day", this rule will NOT go true immediately

                      • Armed for heating has been true for at least 420 seconds
                      • Set point has been at some other value for at least 420 seconds
                      • Thermostat mode is set to heat for at least 420 seconds
                      • House mode not in (night, vacation, away)" has NOT been true for 420 seconds until 7 minutes after you switch to day mode.

                      As long as one of the other elements goes false within 7 minutes, the rule set will never activate. The expected behavior is that the "set point has been at some other value" will go false within 7 minutes. If that doesn't happen, the whole rule set will go true and the set actions will fire including re-running the other rule set and notifying you.

                      I still think this could be improved as I'm pretty sure this will only fire once. If the second attempt at setting the thermostat fails, this rule will remain set and there is nothing to cause it to un-set and then re-activate. That could be your desired behavior if you want to manually fix it when it fails the first time and avoid calling the rule every 7 minutes on repeated failures.

                      I dealt with a lot of the same issues setting up rules for my flaky Lennox thermostat. It's still in Node-Red and looks like this:

                      55821e35-adfb-495c-b2b3-2a6ad7ea47bd-image.png <img src="blob:chrome-untrusted://media-app/55d4404c-a480-4453-ae24-0e6410279a3b" alt="Screenshot 2021-11-29 11.34.25.png"/>

                      I'm not smart/experienced/brave enough to try to replicate that in MSR yet.

                      1 Reply Last reply
                      0
                      • toggledbitsT toggledbits locked this topic on
                      Reply
                      • Reply as topic
                      Log in to reply
                      • Oldest to Newest
                      • Newest to Oldest
                      • Most Votes


                      Recent Topics

                      • Advice reqeusted to migrate MSR from Bare Metal to Container
                        T
                        tamorgen
                        0
                        5
                        44

                      • Reactor (Multi-System/Multi-Hub) Announcements
                        toggledbitsT
                        toggledbits
                        5
                        122
                        35.4k

                      • Z-Wave Future....
                        CatmanV2C
                        CatmanV2
                        0
                        5
                        132

                      • Can´t restart or upgrade/deploy MSR
                        toggledbitsT
                        toggledbits
                        0
                        4
                        87

                      • [Solved] Limit HA Entity in MSR
                        wmarcolinW
                        wmarcolin
                        0
                        7
                        191

                      • Disaster recovery and virtualisation
                        CatmanV2C
                        CatmanV2
                        0
                        5
                        662

                      • Remote access of Zwave stick from Z-wave server
                        CatmanV2C
                        CatmanV2
                        0
                        3
                        384

                      • Organizing/ structuring rule sets and rules
                        G
                        gwp1
                        0
                        5
                        374

                      • Moving MSR from a QNAP container to RP 5 - some issues
                        G
                        gwp1
                        0
                        5
                        346

                      • Widget deletion does not work and landing page (status) is empy
                        G
                        gwp1
                        0
                        4
                        340

                      • Need help reducing false positive notifications