UI not loading after upgrading to 26318
tunnusT
Sorry for a hasty post, will update some details later, but the scenario is that I managed to type a wrong password for too many times and had the following users.yaml section: authtrack: max_attempts: 4 within_minutes: 180 # 180 minutes = 3 hrs block_expiration_minutes: 10080 # 7 days At this time I used build 26298. Then noticed there's a new build with a bypass blocking feature (and yes, it said it won't remove existing block). Anyway, went ahead and upgraded to 26318, but the problem now is that UI is not loading at all (page does not answer). This also means that I cannot use "http://reactor_host:port/diag/clear_authtrack?askauth" command to clear the block (or use any other source IP for login). Docker container stays up & running and does not exit. I'll try to dig up some logs, but anything that I could immediately try out (could I delete a particular file for example)? EDIT: some logs [latest-26318]2026-11-17T20:42:32.337Z <Rule:INFO> MSR startup (rule-lculfnhm in Miscellaneous) started [latest-26318]2026-11-17T20:42:32.343Z <httpapi:NOTICE> httpapi#1 HTTP server listening on :::8111 [latest-26318]2026-11-17T20:42:32.347Z <httpapi:INFO> httpapi#1 local docs found in /opt/reactor/docs/html; setting up static service [latest-26318]2026-11-17T20:42:32.354Z <app:NOTICE> Starting WSAPI... [latest-26318]2026-11-17T20:42:32.355Z <wsapi:NOTICE> wsapi: starting version 26298 protocol [latest-26318]2026-11-17T20:42:32.523Z <Engine:INFO> Engine#1 master timer tick, local time "17/11/2026 22:42:32" (TZ offset 120 mins from UTC) [latest-26318]2026-11-17T20:42:32.542Z <Engine:NOTICE> Starting reaction MSR startup<SET> (rule-lculfnhm:S) [latest-26318]2026-11-17T20:42:32.545Z <Notifier:null> Module Notifier v26186 [latest-26318]2026-11-17T20:42:32.545Z <Engine:INFO> MSR startup<SET> all actions completed. [latest-26318]2026-11-17T20:42:32.557Z <Rule:INFO> Rule#rule-lculfnhm reaction rule-lculfnhm:S completed [latest-26318]2026-11-17T20:42:32.558Z <default:null> Module NotifyTelegram v26177
Multi-System Reactor
[Resolved] Hubitat upgrade 2.5.3.123 may have broken login
3
Topic thumbnail image
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Reactor Inspect - a small read-only helper panel for MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Reverse proxy & API ACL
tunnusT
I'm trying to allow anonymous access from a local network to /api/v1/log, but the problem now with the reverse proxy configuration is that this access is open via proxy to the internet. At least I wasn't able to configure ACL so that only an access from a local network would be permitted. reactor.yaml: baseurl: "http://192.168.1.12:8111" proxy_baseurl: "https://external.com:30000" trusted_proxy: "192.168.1.12" Local traffic would originate from 192.168.1.0/24 network. Synology is acting as a reverse proxy and hosting MSR as a docker container (which has its own network and IP 172.18.0.5). MSR build is latest-26298-fbb75fb8 users.yaml: - url: "/api/v1/log" method: "GET" source_ip: 172.18.0.0/24 allow: true Using the above ACL works, but it enables access via proxy also. If I use source_ip: 192.168.1.0/24, then it doesn't work either locally or remotely. So I'm kinda lost what should I use as source_ip in this case?
Multi-System Reactor
MFA
T
Topic thumbnail image
Multi-System Reactor
Grouped devices
G
I've seen many of you using Dynamic Group Controller. I'm using it myself for monitoring device battery levels. I've read and re-read the Dynamic Group Controller docs and still cannot come to an answer for my question so let me paint my scenario: I've migrated from EchoSpeaks in Hubitat ('cause borked and seemingly unmaintained) to Alexa Devices in Home Assistant ('cause not borked in 2026.11.0) to be able to send TTS to my Echo devices. In EchoSpeaks I could create groups. Sweet. In Alexa Devices I don't seem to be able to do so. As such, my thought was "wait - isn't there a way in MSR?" Is this an effective scenario that Dynamic Group Controller can be used for?
Multi-System Reactor
Login protections
tunnusT
Topic thumbnail image
Multi-System Reactor
Reactor Build 26284 stuck at Loading Reactor UI
T
Topic thumbnail image
Multi-System Reactor
MSR with reverse proxy
tunnusT
I'm trying to use MSR via reserve proxy in Synology DSM, but MSR page does not load https://<public ip>:30000/reactor/en-US/ At the same time logging page loads normally https://<public ip>:30000/api/v1/log I thought maybe authentication was messing it up, but there was no deny entries in the log, and also disabling authentication did not make any difference. For this use case VPN is not an option (that works, but as said not an option for this particular use case). Any ideas what could cause this? MSR build latest-26242-28d69aa8, Chrome browser
Multi-System Reactor
Missing attribute after upgrade
3
Topic thumbnail image
Multi-System Reactor
[MSR] Native fan capabilty
therealdbT
Nothing more to add. I see we have hvac_blower, but, anyway, maybe a native fan on the same assumptions of the fan from HASS could be reasonable. I have a couple of them. ie, this is from ESPHome via HASS. x_hass.domain="fan" x_hass.entity_id="fan.kitchen_seashell_hood_ventilation_fan" x_hass.floor_id=null x_hass.services=["fan","esphome"] x_hass.source="esphome" x_hass.state="off" x_hass_attr.friendly_name="Seashell Hood Ventilation Fan" x_hass_attr.percentage=50 x_hass_attr.percentage_step=25 x_hass_attr.preset_mode="" x_hass_attr.preset_modes=[] x_hass_attr.supported_features=49 Thanks.
Multi-System Reactor
[MSR] Rule do not fire
therealdbT
Topic thumbnail image
Multi-System Reactor
Rule condition shows TRUE in UI but Rule never transitions to SET — survives full restart
N
Build: latest-26221-b25bb3e3, Docker on Synology. Hi, I have a Rule whose Trigger/Constraints reference other Rules via Rule State ... is TRUE. At some point it stops firing. Expanding the rule's condition tree in the UI shows every Trigger and Constraint condition green/TRUE — confirmed live by walking into the room and watching Motion go true in real time. Rule History shows no new SET, just old reset entries. Tried, on the same rule, same evening: recreating the trigger conditions with fresh IDs, recreating the constraint conditions with fresh IDs (flat and wrapped in a new Group — wrapping in a Group produced one SET, but it didn't reproduce on repeat attempts with the same structure), and finally a full container restart with a verified-correct saved rule. Still no SET, even with a fresh live motion event right after the restart. Separately, I found that this rule (and its 10 per-room clones) share identical internal condition/group IDs with each other — leftover from a batch clone done months ago, never regenerated. Not sure if that's related, since fixing the IDs didn't reliably fix the symptom either. Has anyone seen a Rule State condition show TRUE in the UI without the Rule ever producing a SET, surviving a clean restart? Thanks in advance
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Unofficial thread for compatibility
tunnusT
As there are statements about compatibility for home assistant versions in MSR new version announcements (e.g. "HassController: Bless Hass to 2025.7.3"), I thought it would be good idea to track other controllers as well. As an example, I can confirm that build "latest-25208-c53e8513" works with Hubitat Elevation C-8 platform version 2.4.2.134 using Maker API. Updates: (the latest versions first in the list) OK: build "latest-25264-2fbe9217" with Hubitat C-8 platform v. 2.4.3.123
Multi-System Reactor
Ooops - Deleted Reactor Ex Machina II
R
I accidentally deleted Reactor Ex Machina II (REM II) from my Reactor rules. I tried to recover it by deleting the .json and .dval in the Rules subdirectory and then recreating it from Togglebits original posting, but that did not work. Does anyone know how to recover REM ll ?
Multi-System Reactor
Bail out of failed reaction?
T
Topic thumbnail image
Multi-System Reactor
Arming Envisalink panel from MSR
T
Topic thumbnail image
Multi-System Reactor
[Solved] DynamicGroupController updating members issue
CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor

Another philosophy question: Modes

Scheduled Pinned Locked Moved Multi-System Reactor
8 Posts 3 Posters 2.1k Views 3 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • G Offline
    G Offline
    gwp1
    wrote on last edited by
    #1

    General logic says Day is sunrise to sunset and Evening is sunset to sunrise noting that, at some point, you will manually trigger Night when retiring to sleep.

    That's fine.

    Except...

    What if your daily wake times fall before sunrise? Do you apply the theory that your "day" starts when you wake or stick with day starting at sunrise?

    The conundrum for me here is that my HVAC kicks into gear when mode = Day. If my wake time during parts of the year fall outside "official" Day then it's cold in the house when I'm crawling out of bed.

    How are others architecting this?

    *Hubitat C-7 2.5.2.139
    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

    *HAOS
    Core 2026.10.4
    w/ HA Connect ZWA-2 & ZBT-2
    FW: v1.1
    SDK: v7.23.1

    *Prod MSR in docker/portainer
    MSR: latest-26298-fbb75fb8
    MQTTController: 25139
    ZWave Controller: 25139

    1 Reply Last reply
    0
    • therealdbT Offline
      therealdbT Offline
      therealdb
      wrote on last edited by
      #2

      I use a variable called dark to represent the sun status. This is used to run lights and so on. And then I have house modes, and that represent the house status. If I’m moving from night to home and it’s still dark, for example, I’ll turn on lights.
      Same is for heating, where thermostat are increased if we’re home, otherwise are staying at a given comfort temperature.
      I also have party, house, green mode and mute flag, and all are used to drive lights, announcements and co accordingly. Those are flags, so I could even mix them (ie it’s dark, party is on - or it’s away, green mode is on, etc).
      Some mode (ie mute) are intrinsically turned on/off based on other sensors, ie to avoid announcements when everyone except me is sleeping in the house.

      --
      On a mission to automate everything.

      My MS Reactor contrib
      My Luup Plug-ins

      G 1 Reply Last reply
      1
      • CatmanV2C Offline
        CatmanV2C Offline
        CatmanV2
        wrote on last edited by
        #3

        I've tried to measure darkness to control lights, but just end up using times before and after sunset

        C

        The Ex-Vera abuser know as CatmanV2.....

        G 1 Reply Last reply
        0
        • CatmanV2C CatmanV2

          I've tried to measure darkness to control lights, but just end up using times before and after sunset

          C

          G Offline
          G Offline
          gwp1
          wrote on last edited by
          #4

          @catmanv2 I have an Ambient weather station in my backyard. I determined what solar radiation level was "the one" when it became darkish in the house (during storms as well as end of day.)

          Works a treat, it does.

          *Hubitat C-7 2.5.2.139
          *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

          *HAOS
          Core 2026.10.4
          w/ HA Connect ZWA-2 & ZBT-2
          FW: v1.1
          SDK: v7.23.1

          *Prod MSR in docker/portainer
          MSR: latest-26298-fbb75fb8
          MQTTController: 25139
          ZWave Controller: 25139

          CatmanV2C 1 Reply Last reply
          1
          • therealdbT therealdb

            I use a variable called dark to represent the sun status. This is used to run lights and so on. And then I have house modes, and that represent the house status. If I’m moving from night to home and it’s still dark, for example, I’ll turn on lights.
            Same is for heating, where thermostat are increased if we’re home, otherwise are staying at a given comfort temperature.
            I also have party, house, green mode and mute flag, and all are used to drive lights, announcements and co accordingly. Those are flags, so I could even mix them (ie it’s dark, party is on - or it’s away, green mode is on, etc).
            Some mode (ie mute) are intrinsically turned on/off based on other sensors, ie to avoid announcements when everyone except me is sleeping in the house.

            G Offline
            G Offline
            gwp1
            wrote on last edited by
            #5

            @therealdb said in Another philosophy question: Modes:

            Those are flags

            Define what you mean, here, please: "flags".

            I like your overall concept of splitting out actual modes from other controls. Interest is piqued.

            *Hubitat C-7 2.5.2.139
            *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

            *HAOS
            Core 2026.10.4
            w/ HA Connect ZWA-2 & ZBT-2
            FW: v1.1
            SDK: v7.23.1

            *Prod MSR in docker/portainer
            MSR: latest-26298-fbb75fb8
            MQTTController: 25139
            ZWave Controller: 25139

            therealdbT 1 Reply Last reply
            0
            • G gwp1

              @catmanv2 I have an Ambient weather station in my backyard. I determined what solar radiation level was "the one" when it became darkish in the house (during storms as well as end of day.)

              Works a treat, it does.

              CatmanV2C Offline
              CatmanV2C Offline
              CatmanV2
              wrote on last edited by
              #6

              @gwp1 said in Another philosophy question: Modes:

              @catmanv2 I have an Ambient weather station in my backyard. I determined what solar radiation level was "the one" when it became darkish in the house (during storms as well as end of day.)

              Works a treat, it does.

              I've looked at some of these. I have plenty of light sensors already and I just can't get a good lumen level 😞

              Can you share your model?

              C

              The Ex-Vera abuser know as CatmanV2.....

              G 1 Reply Last reply
              0
              • G gwp1

                @therealdb said in Another philosophy question: Modes:

                Those are flags

                Define what you mean, here, please: "flags".

                I like your overall concept of splitting out actual modes from other controls. Interest is piqued.

                therealdbT Offline
                therealdbT Offline
                therealdb
                wrote on last edited by
                #7

                @gwp1 they’re just virtual switches. In software development we usually refer to them as flags. You could enable or disable a flag to influence the corresponding features. I’m usually combining many of them. I also have brightness sensors to control my blinds.

                --
                On a mission to automate everything.

                My MS Reactor contrib
                My Luup Plug-ins

                1 Reply Last reply
                0
                • CatmanV2C CatmanV2

                  @gwp1 said in Another philosophy question: Modes:

                  @catmanv2 I have an Ambient weather station in my backyard. I determined what solar radiation level was "the one" when it became darkish in the house (during storms as well as end of day.)

                  Works a treat, it does.

                  I've looked at some of these. I have plenty of light sensors already and I just can't get a good lumen level 😞

                  Can you share your model?

                  C

                  G Offline
                  G Offline
                  gwp1
                  wrote on last edited by gwp1
                  #8

                  @catmanv2 Hardware:Ambient Weather WS-2902

                  They have an API you can call to your station and pull in the data. I drive my HVAC with it, too.

                  *Hubitat C-7 2.5.2.139
                  *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                  *HAOS
                  Core 2026.10.4
                  w/ HA Connect ZWA-2 & ZBT-2
                  FW: v1.1
                  SDK: v7.23.1

                  *Prod MSR in docker/portainer
                  MSR: latest-26298-fbb75fb8
                  MQTTController: 25139
                  ZWave Controller: 25139

                  1 Reply Last reply
                  2
                  • toggledbitsT toggledbits locked this topic on
                  Reply
                  • Reply as topic
                  Log in to reply
                  • Oldest to Newest
                  • Newest to Oldest
                  • Most Votes


                  Recent Topics

                  • UI not loading after upgrading to 26318
                    toggledbitsT
                    toggledbits
                    0
                    6
                    194

                  • [Resolved] Hubitat upgrade 2.5.3.123 may have broken login
                    toggledbitsT
                    toggledbits
                    0
                    8
                    334

                  • Reactor (Multi-System/Multi-Hub) Announcements
                    toggledbitsT
                    toggledbits
                    5
                    153
                    164.1k

                  • Reactor Inspect - a small read-only helper panel for MSR
                    G
                    gwp1
                    2
                    8
                    649

                  • Reverse proxy & API ACL
                    tunnusT
                    tunnus
                    0
                    9
                    563

                  • MFA
                    T
                    tamorgen
                    0
                    28
                    1.5k

                  • Grouped devices
                    G
                    gwp1
                    0
                    3
                    219

                  • Login protections
                    toggledbitsT
                    toggledbits
                    0
                    2
                    256

                  • Reactor Build 26284 stuck at Loading Reactor UI
                    T
                    tamorgen
                    0
                    16
                    1.8k

                  • MSR with reverse proxy
                    tunnusT
                    tunnus
                    0
                    12
                    928

                  • Missing attribute after upgrade
                    3
                    3rdStng
                    0
                    3
                    714

                  • Use of Google Gemini as an MSR and Hubitat configuration aid
                    therealdbT
                    therealdb
                    0
                    2
                    356
                  Powered by NodeBB | Contributors
                  Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                  • Login

                  • Don't have an account? Register

                  • Login or register to search.
                  • First post
                    Last post
                  0
                  • Categories
                  • Recent
                  • Tags
                  • Popular
                  • Unsolved