@toggledbits I understand that you do not perform testing on Mac computers but thought I'd share the following with you in case something can be done.
I started seeing these errors with version 24302. I thought that upgrading to 24343 would have fixed the issue but unfortunately not. I either have to close the browser or clear the cache for the errors to stop popping-up but they slowly come back.
I see these errors on the following browsers:
Safari 16.6.1 on macOS Big Sur Safari 18.1.1 on MacOS Sonoma DuckDuckGo 1.118.0 on macOS Big Sur and Sonoma Firefox 133.0.3 on macOS Big Sur Chrome 131.0.6778 on macOS Big SurHere are the errors
Safari while creating/updating an expression
@http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:543:91 makeExprMenu@http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:537:28 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:92:64 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:89:68 each@http://192.168.0.13:8111/node_modules/jquery/dist/jquery.min.js:2:3133 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:89:35 @http://192.168.0.13:8111/client/MessageBus.js:98:44 forEach@[native code] @http://192.168.0.13:8111/client/MessageBus.js:95:54 @http://192.168.0.13:8111/client/MessageBus.js:106:44 @http://192.168.0.13:8111/client/Observable.js:78:28 signalModified@http://192.168.0.13:8111/reactor/en-ca/lib/js/ee.js:146:21 signalModified@http://192.168.0.13:8111/reactor/en-ca/lib/js/expression-editor.js:40:29 reindexExpressions@http://192.168.0.13:8111/reactor/en-ca/lib/js/expression-editor.js:71:32 @http://192.168.0.13:8111/reactor/en-ca/lib/js/expression-editor.js:608:40 dispatch@http://192.168.0.13:8111/node_modules/jquery/dist/jquery.min.js:2:40040DuckDuckGo while clicking on status
http://192.168.0.13:8111/reactor/en-ca/lib/js/reactor-ui-status.js:789:44 asyncFunctionResume@[native code] saveGridLayout@[native code] dispatchEvent@[native code] _triggerEvent@http://192.168.0.13:8111/node_modules/gridstack/dist/gridstack.js:1401:30 _triggerAddEvent@http://192.168.0.13:8111/node_modules/gridstack/dist/gridstack.js:1383:31 makeWidget@http://192.168.0.13:8111/node_modules/gridstack/dist/gridstack.js:968:30 addWidget@http://192.168.0.13:8111/node_modules/gridstack/dist/gridstack.js:388:24 placeWidgetAdder@http://192.168.0.13:8111/reactor/en-ca/lib/js/reactor-ui-status.js:183:44Firefox while updating a rule
@http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:543:91 makeExprMenu@http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:537:28 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:92:64 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:89:68 each@http://192.168.0.13:8111/node_modules/jquery/dist/jquery.min.js:2:3133 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reaction-editor.js:89:35 @http://192.168.0.13:8111/client/MessageBus.js:98:44 forEach@[native code] @http://192.168.0.13:8111/client/MessageBus.js:95:54 @http://192.168.0.13:8111/client/MessageBus.js:106:44 @http://192.168.0.13:8111/client/Observable.js:78:28 notifySaved@http://192.168.0.13:8111/reactor/en-ca/lib/js/ee.js:82:21 notifySaved@http://192.168.0.13:8111/reactor/en-ca/lib/js/expression-editor.js:47:26 @http://192.168.0.13:8111/reactor/en-ca/lib/js/reactor-ui-rules.js:1460:39 forEach@[native code] @http://192.168.0.13:8111/reactor/en-ca/lib/js/reactor-ui-rules.js:1459:58Chrome while creating/updating an expression
TypeError: Cannot read properties of undefined (reading 'getEditor') at RuleEditor.makeExprMenu (http://192.168.0.13:8111/reactor/en-ca/lib/js/rule-editor.js:1788:86) at Object.handler (http://192.168.0.13:8111/reactor/en-ca/lib/js/rule-editor.js:2174:54) at http://192.168.0.13:8111/client/MessageBus.js:98:44 at Array.forEach (<anonymous>) at MessageBus._sendToBus (http://192.168.0.13:8111/client/MessageBus.js:95:54) at MessageBus.send (http://192.168.0.13:8111/client/MessageBus.js:106:44) at ExpressionEditor.publish (http://192.168.0.13:8111/client/Observable.js:78:28) at ExpressionEditor.signalModified (http://192.168.0.13:8111/reactor/en-ca/lib/js/ee.js:146:14) at ExpressionEditor.signalModified (http://192.168.0.13:8111/reactor/en-ca/lib/js/expression-editor.js:40:15) at ExpressionEditor.reindexExpressions (http://192.168.0.13:8111/reactor/en-ca/lib/js/expression-editor.js:71:18) ``Thanks to @toggledbits for adding a custom CSS. I've started doing a darker Reactor style.
Here's the file: https://gist.github.com/dbochicchio/825098ac13b7f8cac22012eae37ff7ce
A couple of things are still too bright and I'll eventually catch-up. Just place it under your /config directory, naming the file as customstyles.css. Hard refresh your browser.
Hi
Having to rebuild my Linux Debian box as the SSD failed. And I have forgotten exactly what I did the first time to get it all setup.
I have Debian 12 up and running on the new SSD, I only have console no Desktop GUI.
I am trying to do the bare metal install for MSR. However I am not sure if I am meant to install nodejs whlist logged in as the root user or as the none root user with my name ?
I used putty and connected via SSH and logged in as root and I installed nodejs but I think this was wrong as when logged in as my user name and I do a node -v command it says node is not installed or doesn't show any version number anyway.
But when logged in as root and I do a node -v command it does show me its installed and displays the version number. maybe its a path issue for my username and he can't see node is installed?
So now I am thinking I should of installed node whilst logged in as my user name and not as the root user.
This is how I installed nodejs as whilst logged in as root
ac7bf6c3-23ad-46fc-8ada-44af6704e63e-image.png
Thanks in advance.
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.As the title says, here's my OpenAI Controller for Reactor:
OpenAI Controller per Reactor. Contribute to dbochicchio/reactor-openai development by creating an account on GitHub.
It supports both OpenAI and Azure OpenAI endpoints. You'll need keys/endpoints, according to each service.
The controller supports multiple models, and each one could be mapped as an entity.
It's quite easy to use, and responses can be stored in variables, for easy access. Or sent to another action (Text To Speech, another endpoint, etc).
9013ae50-fd68-42a2-87c3-97479132e465-image.png
80a88eec-7c89-464a-8196-690b4b72d044-image.png
Have fun with LLM into your scenes!
In Home Assistant I have an integration that if I add entities to it, I will get the following error in MSR as certain entity values I'm using in expressions are null for a moment. This is more or less cosmetic issue and happens very rarely as I rarely modify that integration on the hass side.
Screenshot 2024-11-28 at 22.20.41.png
And the expression is
Screenshot 2024-11-28 at 22.38.19.png
Could I "wrap" hass-entity shown above somewhat differently to prevent this error from happening? Using build 24302.
Hello
I am trying to set up Multi System Reactor to automate routines across multiple smart home devices & platforms (e.g., Home Assistant, SmartThings, and Hubitat). While I have successfully linked the systems; I am facing issues with:
-Delays in triggering actions on secondary devices.
-Inconsistent execution of complex logic conditions.
-Synchronization of states between devices when one system updates.
Is there a recommended way to optimize performance & confirm seamless state sharing across systems?
I have checked https://smarthome.community/category/22/multi-system-reactor-msbi guide for reference but still need advice.
Any tips on debugging or log analysis to pinpoint where the issue arises would also be appreciated.
Thank you !
I've managed to use MSR UI on iOS devices to some degree*, so that although UI elements (e.g. rule sets) are not visible in portrait mode, you've seen them in landscape. Now with recents builds (24302) this does not work anymore, elements (rule sets, entities) are not anymore visible in landscape mode.
Does anyone have similar experiences? Using iOS 18 and Safari/Chrome browser.
( *Drag & drop of rule conditions have never worked on a mobile)
@toggledbits Since I have upgraded ZWaveJSController to 24293 from 24257 I am seeing entries related to registering action set_volume, but action is not defined by the capability 143 every time I restart Reactor.
The Siren seems to be doing what it is supposed to do. The volume levels are fine. Should I worry about it?
Reactor version 24302
ZWaveJSController version 24293
Z-Wave JS UI version 9.27.4
zwave-js version 14.3.4
I have the following ACL defined:
groups: admin: users: - admin applications: true api_acls: # This ACL allows users in the "admin" group to access the API - url: "/api" group: admin allow: true log: true # This ACL allows anyone/thing to access the /api/v1/alive API endpoint - url: "/api/v1/alive" allow: trueAnd I have authenticated to MSR as "admin" user. However, I'm getting "access denied" when trying to access http://*******:8111/api/v1/log
So what I'm missing, is my ACL incorrectly defined?
Using build 24302 on Docker.
Hi
I have just connected a bunch of EzloPi controllers to MSR to import some ESP based devices etc.
They all seemed to have worked and imported in to MSR apart from I have one missing device. It is a Digital Gas Sensor device.
This is how that device looks in the Ezlo API.
Devices Info:
_id: "10696001" deviceTypeId: "ezlopi" parentDeviceId: "10696000" category: "level_sensor" subcategory: "" gatewayId: "457a5069" batteryPowered: false name: "Gas Sensor Digital" type: "sensor" reachable: true persistent: true serviceNotification: false armed: false roomId: "" security: "no" ready: true status: "idle" parentRoom: true protectConfig: "default"Items Info:
_id: "20696001" deviceId: "10696001" hasGetter: true hasSetter: false name: "smoke_density" show: true valueType: "substance_amount" scale: "parts_per_million" value: 2.7472610473632812 valueFormatted: "2.75" status: "idle"There is also an Analog Gas sensor that one did import in to MSR OK.
68d63dab-b871-4f44-912b-cf6e0b9eb4c6-image.png
Devices Info:
_id: "10696000" deviceTypeId: "ezlopi" parentDeviceId: "10696000" category: "security_sensor" subcategory: "gas" gatewayId: "457a5069" batteryPowered: false name: "Gas Sensor Analog" type: "sensor" reachable: true persistent: true serviceNotification: false armed: false roomId: "" security: "no" ready: true status: "idle" parentRoom: true protectConfig: "default"Items Info:
_id: "20696000" deviceId: "10696000" hasGetter: true hasSetter: false name: "gas_alarm" show: true valueType: "token" enum: 0: "no_gas" 1: "combustible_gas_detected" 2: "toxic_gas_detected" 3: "unknown" valueFormatted: "no_gas" value: "no_gas" status: "idle"And this is how this MQ2 Gas Sensor looks like on their dashboard:
Digital
cb77dfa3-4af5-4d06-9635-89207a716a89-image.png
Analog
4fb4da1b-e946-4b89-876c-bcd9f5699b6c-image.png
They have an EzloPi website here you can create your own sensor projects using ESP boards, which is very interesting stuff!
And I just wrote on the Ezlo forum here, how to connect an EzloPi controller to MSR.
THANKS.
A couple of things for you @toggledbits, since you mentioned that this release has new features and some tweaks are expected.
Local expressions cannot be deleted. Pushing the X button has no effect for me.
When cloning an entity action, the result is strange (first is cloned one, second is the original action):
a92ea094-9e2c-4aaa-bf47-2d07a6ffdbd0-image.png
When changing the action on the cloned element, the params are added to the original one. See screenshot:
92ac3011-83c8-466b-bd23-47d483ad7a52-image.png
Dark theme has a couple of strange contrasts. One is visible in the previous screenshots (white text on yellow background). Another one is in groups (blue text on blue background):
9b3c4988-53ef-44e6-9672-30e744cacb75-image.png
Overall, I found blue, yellow, red and green (in buttons and forms) to be too bright.
On the bright side:
I love the new script action: thank you! The dark theme is a great start to avoid getting blinded at night I promise I'll try very soon the new features around actions. Thanks!@toggledbits
I just upgraded to version MSR 24293, bare metal running on Fedora. Upon restart, I am getting a error banner:
I followed the new directions about npm
npm i --no-save --no-package-lock --omit dev
Any idea what the issue is?
Seems like switching the UI to the newly added dark mode (thank you for this) does nothing. The UI stays in light mode and only a few buttons turn into dark mode (see screenshot)
Things I have tried:
Hard refresh
Different browser
Different computer
Restarting Reactor
Failed troubleshooting attempts:
No errors in Chrome console
No relevant errors in Reactor log (can still PM the full log file)
Reactor version: latest-24293-ea42a81d
Hardware: Odroid N2+
Linux version: Ubuntu 24.04.1 LTS
3df2806f-9146-485b-9ec1-d056e91cefe5-image.png Dark mode enabled
ff823023-c079-4684-b01f-d6ac6527d31a-image.png Light mode enabled
Good morning,
I have a service MQTT service that needs a restart occasionally. The add-on (Smartbed MQTT) is for the smart bed base for my bed. It has a "safety light" that I can control from HAAS & MSR as a light entity, and also moves the head of the bed to a preset at bedtime, and then lies it back flat in the morning The problem is, from time to time, the light becomes "unavailable" Restarting from the Add-ons tab in HAAS always fixes it, but I should be able to detect when it happens when "light.tempur_pedic_safety_lights" is not true or false, i.e., unavailable.
What I don't know how to do is how to restart that service. Does anybody have experience in restarting add-ons from MSR?
Running:
Reactor (Multi-hub) latest-24212-3ce15e25 ZWaveJSController [0.1.24232]HAAS:
RPi5-64 (8GB) Core 2024.7.3 Supervisor 2024.08.0 Operating System 13.0 Frontend 20240710.0Need Testers
-
OK. That's normal behavior if the login/session cookie expires or is no longer valid. And it's all browser-side, so the logs aren't of any value there. And it's working for me, so we may have to dig a little. Next time you are tempted to use the Restart button, just do a plain refresh on your browser and see (report) what happens.
Also, what browser are you using? And, please upload your users.yaml file (redact any plaintext passwords)
-
@toggledbits Using Brave browser. Redacted
users.yaml
on it's way. -
If you just refresh the page instead of hitting the button, does it refresh, or go to the login page?
-
userauth build 24143
- Fixes something that might, perhaps, address the Restart button issue some people are having (and I cannot reproduce at all on any broser). Also adds some debug (browser side) that we might be able to access to figure it out if it persists.
- Revamps the port determination. Some of you, particularly docker users, may find that your Reactor UI shifts to port 8554, and is actually the desired location for HTTPS service.
- Updated a lot of docs, including developer docs for building controllers.
-
@toggledbits Restart-button still does not work. Chrome:
-
That's ACL restriction. You probably need to give logged-in users permission to use the API, or at least, that particular API.
-
@toggledbits here's my users.yaml: (how should I change that?)
users: # This section defines your valid users. The format is: # username: password (one per line). admin: xxxxxxxx groups: admin: users: - admin applications: true # special form allows access to ALL applications api: default: allow session: timeout: 43200 rolling: true # activity extends timeout when true # If log_acls is true, the selected ACL for every API access is logged. log_acls: true # If debug_acls is true, even more information about ACL selection is logged. debug_acls: false
-
That's not up to date with current usage/structure. Refer to the
users.yaml
file that came in thedist-config
directory, and the documentation for Access Control. -
@toggledbits ok, using that new file as a reference, now Restart-button is working
-
userauth build 24145
- Fix issue with VirtualEntityController weighted average computation (remove workarounds if you added them per earlier post).
- Make login page react to ENTER key.
- Remove dependency on user-supplied ACL for certain functions in the UI, like the Restart Reactor button on the Tools tab. These functions are now performed through the websocket interface.
If there are no further issues, this build will likely be the last on this branch, and I will be merging all the changes into
latest
and releasing that over the weekend or sometime next week. -
@toggledbits minor thing still in the docs related to time series, there's one example using "wma" name
-
I actually made
wma
a synonym forwa
, so it should work either way. But, I will make the doc consistent. -
@toggledbits ok, thanks!
One bug might be lurking in, as I have now three virtual entities all using time series with "wa", and from time to time I'm seeing "null" value at least in one of them (sources should be stable). Still, this situation seems to be hard to reproduce, so just have to keep an eye on it. But letting you know if you'd know better what to look for.
temperature_sensor.units=null temperature_sensor.value=null x_virtualentity.last_request_time=null x_virtualentity.request_failures=null x_virtualentity.template=null x_virtualentity.timeseries_debug=[{"time":1716579660000,"value":19.6}] x_virtualentity.timeseries_interval=1 x_virtualentity.timeseries_retention=3
config:
... model: time series entity: "hass>sensor_outdoor_temperature" attribute: "temperature_sensor.value" interval: 5 # minutes retention: 20 # minutes aggregate: wa depth: 4 precision: 1 weight: - 0.50 - 0.35 - 0.10 - 0.05
-
OK. I'll do some more experiments here. Let me know if anything turns up on your end.
-
@toggledbits this particular time series has now been stable, at least I haven't seen null values recently, but as I'm testing an other kind of series ("accel"), I'm only getting null (see below).
First, my config:
... name: "Netatmo CO2 change rate" capabilities: value_sensor: attributes: value: model: time series entity: "hubitat>88" attribute: "x_hubitat_CarbonDioxideMeasurement.carbonDioxide" interval: 5 # minutes retention: 30 # minutes aggregate: accel depth: 5 precision: 2 primary_attribute: value_sensor.value type: ValueSensor
and from Entities view:
value_sensor.units=null value_sensor.value=null x_virtualentity.last_request_time=null x_virtualentity.request_failures=null x_virtualentity.template=null x_virtualentity.timeseries_debug=[{"time":1716813840000,"value":774},{"time":1716814140000,"value":775},{"time":1716814440000,"value":775},{"time":1716814740000,"value":760},{"time":1716815040000,"value":760},{"time":1716815340000,"value":752},{"time":1716815640000,"value":752}] x_virtualentity.timeseries_interval=5 x_virtualentity.timeseries_retention=30
Could be a trivial configuration mistake, but I followed an example in the docs.
-
Acceleration is change in velocity (rate). In order to determine the change in rate, two rates have to be calculated.
The
depth
is used to determine the depth of the rate computation, so a depth of three would mean the rate is computed across a span of 3 samples. The first rate would therefore be computed from samples 1 and 3 (span 1-3, rate between t and t-10), and the second would be computed from samples 3 and 5 (span 3-5, rate between t-10 and t-20). The change in the two rates is computed to get the acceleration.That means the number of samples required for the computation is
2 * depth - 1
.You have 7 samples in your time series, from t to t-30 in 5 minute increments: t, t-5, t-10, t-15, t-20, t-25, and t-30. Let's number these from 1 to 7, with 1 at t (newest) and 7 at t-30 (oldest). You've specified
5
for the depth, but that would require 9 samples, and you only have 7, so the result is null because the acceleration cannot be computed.Reduce your span to 3 or 4, or increase your sampling period to 40 minutes if you want
depth
of 5 (meaning rate would be computed over the two most recent 20 minute periods). -
@toggledbits thanks (again)! Decreased depth to 4, and now it's working
-