Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. Has something changed with the "Changes" operator in Constraint groups ?
Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor

Has something changed with the "Changes" operator in Constraint groups ?

Scheduled Pinned Locked Moved Multi-System Reactor
6 Posts 4 Posters 296 Views 4 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • cw-kidC Offline
    cw-kidC Offline
    cw-kid
    wrote on last edited by cw-kid
    #1

    Hi

    I was looking at an old rule and I wanted to edit it, to add another Constraint, however I cannot seem to do it.

    On this screen shot you can see an existing entry in the Constraints and on its pull down menu the "Changes" option is available.

    09735de3-8e92-4e12-bfa2-5191f48924a7-image.png

    However on the new line I just added I have no changes option in its pull down menu.

    d85c4067-880e-4281-a12b-dac4d316a4da-image.png

    Here is the original now locked post about this topic.

    https://smarthome.community/topic/395/contact-sensor-opened-1-minute-ago-how?_=1736354690742

    If you look on the old screen shots on that post, I was using the "changes" operator. Like this:

    a1262e01-d3fd-4723-872f-872f1f6d9899-image.png

    However today when I edited this rule the operators are showing as == and not as changes on all the entries in the Constraints area.

    Also the old entries now say -- and the value is blank. But on the new line I just added it says that is not valid, so not sure how the old lines are like that.
    a458d52d-214d-4862-a2b7-d31009f89cde-image.png

    So I am a bit confused what happened.

    Thanks

    G 1 Reply Last reply
    0
    • cw-kidC cw-kid

      Hi

      I was looking at an old rule and I wanted to edit it, to add another Constraint, however I cannot seem to do it.

      On this screen shot you can see an existing entry in the Constraints and on its pull down menu the "Changes" option is available.

      09735de3-8e92-4e12-bfa2-5191f48924a7-image.png

      However on the new line I just added I have no changes option in its pull down menu.

      d85c4067-880e-4281-a12b-dac4d316a4da-image.png

      Here is the original now locked post about this topic.

      https://smarthome.community/topic/395/contact-sensor-opened-1-minute-ago-how?_=1736354690742

      If you look on the old screen shots on that post, I was using the "changes" operator. Like this:

      a1262e01-d3fd-4723-872f-872f1f6d9899-image.png

      However today when I edited this rule the operators are showing as == and not as changes on all the entries in the Constraints area.

      Also the old entries now say -- and the value is blank. But on the new line I just added it says that is not valid, so not sure how the old lines are like that.
      a458d52d-214d-4862-a2b7-d31009f89cde-image.png

      So I am a bit confused what happened.

      Thanks

      G Offline
      G Offline
      gwp1
      wrote on last edited by
      #2

      @cw-kid I feel like there was a thread on this or something in the release notes of a recent version that called this out but I cannot find it in the few minutes I had to search.

      *Hubitat C-7 2.4.1.151
      *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

      *HASS 2025.3.4
      w/ ZST10-700 fw 7.18.3

      *Prod MSR in docker/portainer
      MSR: latest-25082-3c348de6
      MQTTController: 24257
      ZWave Controller: 25082

      1 Reply Last reply
      0
      • therealdbT Offline
        therealdbT Offline
        therealdb
        wrote on last edited by
        #3

        yep, it was removed from 22305.

        • UI/Rules/Reactions: the changes operator should not be available in constraints (changes is an event, and constraints are static, not event-driven).

        --
        On a mission to automate everything.

        My MS Reactor contrib
        My Luup Plug-ins

        1 Reply Last reply
        0
        • cw-kidC Offline
          cw-kidC Offline
          cw-kid
          wrote on last edited by
          #4

          OK thanks for the heads up.

          So anyway to do this now ? I only want the rules Actions to run if the devices listed in the Constraints haven't changed their state within the last number of X seconds etc.

          1 Reply Last reply
          0
          • toggledbitsT Offline
            toggledbitsT Offline
            toggledbits
            wrote on last edited by
            #5

            If you need to use event-driven conditions for a constraint, the simple workaround is to create a rule containing those conditions, and then use a "Rule State" condition in the original rule's constraints to look at the state of the new rule.

            Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

            1 Reply Last reply
            1
            • cw-kidC Offline
              cw-kidC Offline
              cw-kid
              wrote on last edited by
              #6

              OK thanks, I think that works!

              So I have two rules now the main 1st rule that detects Motion on the IP Camera and also a Virtual Switch must be True, those are the two triggers, this is the rule with the Actions in it.

              In the Constraints I am referencing the "Rule State" of the 2nd new rule and that must be False.

              ffb990d2-5b0f-419f-88e3-4cde28ed51b0-image.png

              This is the new 2nd rule and I have just used the Triggers with the "Changes" operator.

              So if any of these devices change their state within the X number of Seconds the OR group will be True thus the 1st main rule would NOT run its Actions in that case.

              But if none of these devices have changed their state within the X number of Seconds the OR group will be False thus the 1st main rule would run its Actions.

              e972131c-82e8-44b6-819f-dfe9a217692a-image.png

              1 Reply Last reply
              1
              • toggledbitsT toggledbits locked this topic on
              Reply
              • Reply as topic
              Log in to reply
              • Oldest to Newest
              • Newest to Oldest
              • Most Votes


              Recent Topics

              • Advice reqeusted to migrate MSR from Bare Metal to Container
                T
                tamorgen
                0
                5
                43

              • Reactor (Multi-System/Multi-Hub) Announcements
                toggledbitsT
                toggledbits
                5
                122
                35.4k

              • Z-Wave Future....
                CatmanV2C
                CatmanV2
                0
                5
                131

              • Can´t restart or upgrade/deploy MSR
                toggledbitsT
                toggledbits
                0
                4
                86

              • [Solved] Limit HA Entity in MSR
                wmarcolinW
                wmarcolin
                0
                7
                191

              • Disaster recovery and virtualisation
                CatmanV2C
                CatmanV2
                0
                5
                662

              • Remote access of Zwave stick from Z-wave server
                CatmanV2C
                CatmanV2
                0
                3
                384

              • Organizing/ structuring rule sets and rules
                G
                gwp1
                0
                5
                374

              • Moving MSR from a QNAP container to RP 5 - some issues
                G
                gwp1
                0
                5
                346

              • Widget deletion does not work and landing page (status) is empy
                G
                gwp1
                0
                4
                338

              • Need help reducing false positive notifications
                T
                tamorgen
                0
                7
                520
              Powered by NodeBB | Contributors
              Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
              • Login

              • Don't have an account? Register

              • Login or register to search.