  4. Why is this Green and ticked when its not true ? And how to do OR
Arming Envisalink panel from MSR
T
Topic thumbnail image
Multi-System Reactor
[Solved] DynamicGroupController updating members issue
CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Upgrade Issues
T
Topic thumbnail image
Multi-System Reactor
[SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
G
Topic thumbnail image
Multi-System Reactor
[SOLVED] Question regarding "in" vs "contains" vs contents of the string
G
Topic thumbnail image
Multi-System Reactor
Logon screen timeout
G
Noticing since 170 that the lock screen doesn't switch to the logon prompt but, rather, stays on the active UI until such time as you go to click something within it. Then it jumps to the login screen. Brave browser Brave 1.92.139 (Official Build) (arm64) Chromium: 150.0.7871.114
Multi-System Reactor
[MSR] Copy&past of actions and/or drag&drop between set/reset
therealdbT
Hey @toggledbits One thing that bothers me while doing work on new systems/new features, is that I cannot copy&paste actions, and I cannot drag&drop between set and resets. #1 is for when I want to copy an action between different rules opened in two separate browser windows, while #2 is when I just need to flip a bunch of actions in the reset, or move some logic back and forth. Both will be appreciated, but I understand the technical challenges. Thanks!
Multi-System Reactor
Upgrade advice - upgrade from aarch64 to ARM64 image
T
I'm currently on version 26011. I understand that the aarch64 image is no longer supported. So, I therefore need to update to the ARM64 image. Can anyone possibly suggest how I update my docker compose.yaml file (see below). Ideally I'd like to keep my existing reactions etc. rather than start from scratch. # Multi-System Reactor template docker-compose.yml (version 22160) # # Change the lines indicated by "DO"... # services: reactor: container_name: reactor environment: # DO change the TZ: line to set your local time zone. # See valid TZ list: https://en.wikipedia.org/wiki/List_of_tz_database_time_zones TZ: GB # # DO NOT change this path. Your directory location is in "source" below. REACTOR_DATA_PREFIX: /var/reactor # DO change the image below to the one you are using (e.g. armv7l or aarch64 for RPi 4) image: toggledbits/reactor:latest-aarch64 restart: "always" expose: - 8111 ports: - 8111:8111 volumes: # DO change the /home/username/reactor below to the directory you created for # your local data; DO NOT change the /var/reactor part - /home/pi/docker/reactor:/var/reactor - /etc/localtime:/etc/localtime:ro tmpfs: /tmp
Multi-System Reactor
Alexa for MSR, any interest?
MikeReadingtonM
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Telegram notification broke with latest update
3
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Phantom device, “INFO” appears
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Mode Status NULL
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] HTTP query failing after version 26177
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Question about the find function
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[Answered] OK to remove old json files?
3
Topic thumbnail image
Multi-System Reactor
Deprecation Announcement: 32-bit ARM *docker* images
toggledbitsT
If you are using the armv7l docker image, the OpenJS Foundation that publishes node is no longer producing 32-bit builds as of v24. That means the last supported LTS version of node for armv7l is v22, which will go End-of-Life in May 2027. Therefore, the Reactor armv7l image is now deprecated and will only be produced until node v22 goes EOL, and I will not publish armv7l images beyond that date. If you are running an RPi 3 or earlier with Reactor, you are on this image, and will need to upgrade hardware to a 64-bit model and use the arm64 image. If you need help getting it done, ask in this category.
Multi-System Reactor
[Solved] build 26150 - engine not starting
G
@toggledbits I pulled the image (well, Watchtower did) and within minutes the whole system went offline. The log looks like it ends with 26143. [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-mkahsmgf/26qq82mw-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lqyfljfi/22f8on0t-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lsb61rw8/24oenqi2-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/rule-lrh58he0:S-1c00gfib-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/1c00dylr-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/1nam9w5u-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-miuh2qqi/22ls4lql-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-kwc6rmci/rule-kwc6rmci:S-1vj8sdfc-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-kwc6rmci/rule-kwc6rmci:S-1qanz01x-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/24lq19p6-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-mk0o8iox/23oy468y-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-miscg2h3/rule-miscg2h3:S-22gmbq1c-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-kxgrfjke/238p0old-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-m7ccsso5/re-m7ccsso5-1r0myjxa-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/19nl9wq2-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/rule-ladyja6a:S-yl3xk9t-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/rule-ladyja6a:S-yl3vv5m-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-ln7j2nqp/re-ln7j2nqp-22mx9lzd-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-ln7j2nqp/22mx87c8-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-licneppy/1mzwe7ht-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ml3194ih/25jqt1j4-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-kxgrg7kf/227hshak-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-reactorexmachina/13ua1p95-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-reactorexmachina/13uagam7-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-grpvl9oypg/rule-grpvl9oypg:R-134x4cbv-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-grpvl9oypg/rule-grpvl9oypg:R-134x2fyl-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-lscjrws1/238p5c22-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lbwr0jvq/1xkczf03-cons [latest-26143]2026-05-31T15:23:44.547Z <Structure:NOTICE> Structure Structure#1 stopped [latest-26143]2026-05-31T15:23:44.547Z <app:NOTICE> Closing APIs... [latest-26143]2026-05-31T15:23:44.547Z <wsapi:NOTICE> wsapi: closing... [latest-26143]2026-05-31T15:23:44.547Z <wsapi:NOTICE> wsapi: disconnecting from "192.168.1.23#82" (1001 service closing) [latest-26143]2026-05-31T15:23:44.548Z <httpapi:NOTICE> HTTP API closing... [latest-26143]2026-05-31T15:23:44.549Z <wsapi:NOTICE> wsapi: server closed [latest-26143]2026-05-31T15:23:44.549Z <httpapi:INFO> HTTP server closed. [latest-26143]2026-05-31T15:23:44.549Z <app:NOTICE> Stopping timers... [latest-26143]2026-05-31T15:23:44.551Z <app:null> Shutdown complete, process ID 1 [latest-26143]2026-05-31T15:23:44.551Z <app:null> Closing logs... [latest-26143]2026-05-31T15:23:44.551Z <default:null> Closing log I can SSH to the VM. Alas, I do not have the previous image for 26143 as I'm a little too quick sometimes on housekeeping.
Multi-System Reactor
http request action & digest auth
tunnusT
I’m using the HTTP Request action in MSR and need to authenticate against an endpoint that uses HTTP Digest authentication. Now that endpoint was changed to use SHA-256 in digest auth, so I would like to know if MSR supports it, or is it limited to MD5-based digest auth?
Multi-System Reactor

Why is this Green and ticked when its not true ? And how to do OR

Scheduled Pinned Locked Moved Multi-System Reactor
19 Posts 3 Posters 3.6k Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • cw-kidC Offline
    cw-kidC Offline
    cw-kid
    wrote on last edited by
    #7

    Its not working.

    Because its not evaluating the current set point properly it seems.

    I set it to 9 which is less than 10 but its still true when it should be false

    d933066c-cb8b-4c2a-9676-4b963e5f2625-image.png

    1 Reply Last reply
    0
    • ElcidE Elcid

      Yes will fire/go true, if one or more windows,

      You can also add time condition, say you wanted to wait 60 seconds just in case some one just opened window for a few seconds.
      click 3 dots for other options on trigger/condition

      cw-kidC Offline
      cw-kidC Offline
      cw-kid
      wrote on last edited by
      #8

      @elcid said in Why is this Green and ticked when its not true ? And how to do OR:

      You can also add time condition, say you wanted to wait 60 seconds just in case some one just opened window for a few seconds

      That's a good idea. I see the extra options but not sure where to stick in my 60 second delay without breaking it even more LOL

      27fb79fa-cd0b-41fc-87d1-0aaeed4b75a8-image.png

      1 Reply Last reply
      0
      • ElcidE Offline
        ElcidE Offline
        Elcid
        wrote on last edited by
        #9

        use sustained for so windows have to be open the sustained time.

        Your group appears to be working as it is true. What are your reactions

        cw-kidC 1 Reply Last reply
        0
        • ElcidE Elcid

          use sustained for so windows have to be open the sustained time.

          Your group appears to be working as it is true. What are your reactions

          cw-kidC Offline
          cw-kidC Offline
          cw-kid
          wrote on last edited by
          #10

          @elcid said in Why is this Green and ticked when its not true ? And how to do OR:

          Your group appears to be working as it is true. What are your reactions

          It shouldn't be true though, it should be false if its not > than 10

          So how can it be true when the thermostat is set to 9 ?

          Reactions ? You mean what is my action ?

          It just sends a HTTP GET request out.

          1 Reply Last reply
          0
          • cw-kidC Offline
            cw-kidC Offline
            cw-kid
            wrote on last edited by cw-kid
            #11

            5b2c1aa0-4af4-4e05-a10e-abf12b3dc41b-image.png

            Its not clear. It says "False" at the top in the blue bar.

            But its green and ticked.

            The current set point is 9.

            My trigger is >10

            So why is it green and ticked ?

            If I open a window now it runs the action when it shouldn't because the heating is off as its currently 10 or less.

            I only want the action to run when the heating is on - setpoint is greater than 10.

            1 Reply Last reply
            0
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by
              #12

              Reminder: this is the first time this code has run in anyone's hands other than mine. 🙂 It is also several years less used and tested than Vera Reactor.

              There is a bug in numeric comparisons, and it will be fixed for today's build (later this evening).

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              1
              • cw-kidC Offline
                cw-kidC Offline
                cw-kid
                wrote on last edited by
                #13

                Thought it was me again doing something stupid.

                1 Reply Last reply
                0
                • cw-kidC Offline
                  cw-kidC Offline
                  cw-kid
                  wrote on last edited by
                  #14

                  How do we update the Raspberry Pi installation when you release an update ?

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by
                    #15

                    No it's me. So sorry. Updates are easy. All you need to do is stop Reactor, un-tar the release package in the reactor directory, and don't run the install script. Just start Reactor again. That will leave your config files intact (the script shouldn't clobber them anyway, but then, 9 isn't greater than 10, is it? Sigh....)

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    cw-kidC 1 Reply Last reply
                    0
                    • cw-kidC Offline
                      cw-kidC Offline
                      cw-kid
                      wrote on last edited by cw-kid
                      #16

                      @toggledbits Hi

                      Was this fixed in the 21050 release ?

                      Thank you.

                      1 Reply Last reply
                      0
                      • toggledbitsT toggledbits

                        No it's me. So sorry. Updates are easy. All you need to do is stop Reactor, un-tar the release package in the reactor directory, and don't run the install script. Just start Reactor again. That will leave your config files intact (the script shouldn't clobber them anyway, but then, 9 isn't greater than 10, is it? Sigh....)

                        cw-kidC Offline
                        cw-kidC Offline
                        cw-kid
                        wrote on last edited by
                        #17

                        @toggledbits said in Why is this Green and ticked when its not true ? And how to do OR:

                        but then, 9 isn't greater than 10, is it? Sigh..

                        No LOL I was having a blonde moment 😲

                        toggledbitsT 1 Reply Last reply
                        0
                        • cw-kidC cw-kid

                          @toggledbits said in Why is this Green and ticked when its not true ? And how to do OR:

                          but then, 9 isn't greater than 10, is it? Sigh..

                          No LOL I was having a blonde moment 😲

                          toggledbitsT Offline
                          toggledbitsT Offline
                          toggledbits
                          wrote on last edited by
                          #18

                          @cw-kid said in Why is this Green and ticked when its not true ? And how to do OR:

                          No LOL I was having a blonde moment

                          Then I must have been having an early senior moment when I leaked that one. Sheesh.

                          I do believe that all of the numeric comparisons are working now.

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          1 Reply Last reply
                          0
                          • cw-kidC Offline
                            cw-kidC Offline
                            cw-kid
                            wrote on last edited by
                            #19

                            @toggledbits Just updated to 0.1.21051 and I can confirm its now working with my Thermostat and the trigger >10

                            10 or below is false and 11 or above is true.

                            Thank you

                            1 Reply Last reply
                            0
                            • toggledbitsT toggledbits locked this topic on
                            Reply
                            • Reply as topic
                            Log in to reply
                            • Oldest to Newest
                            • Newest to Oldest
                            • Most Votes


                            Recent Topics

                            • Arming Envisalink panel from MSR
                              T
                              tamorgen
                              0
                              7
                              124

                            • [Solved] DynamicGroupController updating members issue
                              CrilleC
                              Crille
                              0
                              5
                              81

                            • Reactor (Multi-System/Multi-Hub) Announcements
                              toggledbitsT
                              toggledbits
                              5
                              148
                              129.2k

                            • DynamicGroupController and attributes
                              therealdbT
                              therealdb
                              1
                              5
                              94

                            • Upgrade Issues
                              T
                              tbully
                              0
                              9
                              223

                            • [SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
                              toggledbitsT
                              toggledbits
                              0
                              10
                              242

                            • [SOLVED] Question regarding "in" vs "contains" vs contents of the string
                              G
                              gwp1
                              0
                              5
                              124

                            • openLuup console disappeared - 500 - Internal Server Error
                              A
                              a-lurker
                              0
                              2
                              170

                            • Logon screen timeout
                              G
                              gwp1
                              0
                              5
                              190

                            • [MSR] Copy&past of actions and/or drag&drop between set/reset
                              toggledbitsT
                              toggledbits
                              0
                              9
                              356

                            • Upgrade advice - upgrade from aarch64 to ARM64 image
                              toggledbitsT
                              toggledbits
                              0
                              4
                              212