Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. Ways to find controller's external IP address using MSR
[MSR] Rule do not fire
therealdbT
Topic thumbnail image
Multi-System Reactor
Rule condition shows TRUE in UI but Rule never transitions to SET — survives full restart
N
Build: latest-26221-b25bb3e3, Docker on Synology. Hi, I have a Rule whose Trigger/Constraints reference other Rules via Rule State ... is TRUE. At some point it stops firing. Expanding the rule's condition tree in the UI shows every Trigger and Constraint condition green/TRUE — confirmed live by walking into the room and watching Motion go true in real time. Rule History shows no new SET, just old reset entries. Tried, on the same rule, same evening: recreating the trigger conditions with fresh IDs, recreating the constraint conditions with fresh IDs (flat and wrapped in a new Group — wrapping in a Group produced one SET, but it didn't reproduce on repeat attempts with the same structure), and finally a full container restart with a verified-correct saved rule. Still no SET, even with a fresh live motion event right after the restart. Separately, I found that this rule (and its 10 per-room clones) share identical internal condition/group IDs with each other — leftover from a batch clone done months ago, never regenerated. Not sure if that's related, since fixing the IDs didn't reliably fix the symptom either. Has anyone seen a Rule State condition show TRUE in the UI without the Rule ever producing a SET, surviving a clean restart? Thanks in advance
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Unofficial thread for compatibility
tunnusT
As there are statements about compatibility for home assistant versions in MSR new version announcements (e.g. "HassController: Bless Hass to 2025.7.3"), I thought it would be good idea to track other controllers as well. As an example, I can confirm that build "latest-25208-c53e8513" works with Hubitat Elevation C-8 platform version 2.4.2.134 using Maker API. Updates: (the latest versions first in the list) OK: build "latest-25264-2fbe9217" with Hubitat C-8 platform v. 2.4.3.123
Multi-System Reactor
Ooops - Deleted Reactor Ex Machina II
R
I accidentally deleted Reactor Ex Machina II (REM II) from my Reactor rules. I tried to recover it by deleting the .json and .dval in the Rules subdirectory and then recreating it from Togglebits original posting, but that did not work. Does anyone know how to recover REM ll ?
Multi-System Reactor
Bail out of failed reaction?
T
Topic thumbnail image
Multi-System Reactor
Arming Envisalink panel from MSR
T
Topic thumbnail image
Multi-System Reactor
[Solved] DynamicGroupController updating members issue
CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor
Upgrade Issues
T
Topic thumbnail image
Multi-System Reactor
[SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
G
Topic thumbnail image
Multi-System Reactor
[SOLVED] Question regarding "in" vs "contains" vs contents of the string
G
Topic thumbnail image
Multi-System Reactor
Logon screen timeout
G
Noticing since 170 that the lock screen doesn't switch to the logon prompt but, rather, stays on the active UI until such time as you go to click something within it. Then it jumps to the login screen. Brave browser Brave 1.92.139 (Official Build) (arm64) Chromium: 150.0.7871.114
Multi-System Reactor
[MSR] Copy&past of actions and/or drag&drop between set/reset
therealdbT
Hey @toggledbits One thing that bothers me while doing work on new systems/new features, is that I cannot copy&paste actions, and I cannot drag&drop between set and resets. #1 is for when I want to copy an action between different rules opened in two separate browser windows, while #2 is when I just need to flip a bunch of actions in the reset, or move some logic back and forth. Both will be appreciated, but I understand the technical challenges. Thanks!
Multi-System Reactor
Upgrade advice - upgrade from aarch64 to ARM64 image
T
I'm currently on version 26011. I understand that the aarch64 image is no longer supported. So, I therefore need to update to the ARM64 image. Can anyone possibly suggest how I update my docker compose.yaml file (see below). Ideally I'd like to keep my existing reactions etc. rather than start from scratch. # Multi-System Reactor template docker-compose.yml (version 22160) # # Change the lines indicated by "DO"... # services: reactor: container_name: reactor environment: # DO change the TZ: line to set your local time zone. # See valid TZ list: https://en.wikipedia.org/wiki/List_of_tz_database_time_zones TZ: GB # # DO NOT change this path. Your directory location is in "source" below. REACTOR_DATA_PREFIX: /var/reactor # DO change the image below to the one you are using (e.g. armv7l or aarch64 for RPi 4) image: toggledbits/reactor:latest-aarch64 restart: "always" expose: - 8111 ports: - 8111:8111 volumes: # DO change the /home/username/reactor below to the directory you created for # your local data; DO NOT change the /var/reactor part - /home/pi/docker/reactor:/var/reactor - /etc/localtime:/etc/localtime:ro tmpfs: /tmp
Multi-System Reactor
Alexa for MSR, any interest?
MikeReadingtonM
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Telegram notification broke with latest update
3
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Phantom device, “INFO” appears
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Mode Status NULL
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] HTTP query failing after version 26177
wmarcolinW
Topic thumbnail image
Multi-System Reactor

Ways to find controller's external IP address using MSR

Scheduled Pinned Locked Moved Multi-System Reactor
18 Posts 4 Posters 3.5k Views 4 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • LibraSunL Offline
    LibraSunL Offline
    LibraSun
    wrote on last edited by LibraSun
    #7

    Maybe this is fair game to ask @toggledbits to include as native "system info" within MSR then, instead of rolling our own IP detection. After all, he's already pinging DNS servers to monitor Internet availability.

    Answer: "Nope" (reasons below)

    1 Reply Last reply
    0
    • toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by toggledbits
      #8

      Yeah, but that's not really related; the fact that they are both network-based queries is about where the commonality ends. Pinging the DNS servers doesn't give me any information back other than that they are reachable, and that's not even done the same way (it's handled at layer 3 in the stack). I'm not making a DNS query to them (which would be up at the top layer 7). The ping is meant to be fast and speak only to the functioning of routing beyond the LAN, where a DNS query (or more correctly, a DNS failure) would require a lot more analysis to determine if a problem was a fault of the network layer, the service, the server, etc.

      A DNS query is also not really going to expose your external IP. It has to route through it, for sure, but the DNS response packet itself contains only an answer to the question asked, which is typically "what is the A or AAAA record for <some name>?". The response contains only the answer to the question asked (it's one of <array of addresses>" or "I don't know"), and does not contain routing information for how either the query or the response moved. The only way to use DNS to get your external IP is if (a) your external IP has a name associated with it, (b) the owner of the domain in which the name lives has provided PTR records to provide "reverse DNS" data (map the name back to an IP address), and (c) you make a reverse DNS query for that name (which is not what's happening). That's such a "hail Mary" set of conditions in the real world (and requires user configuration when it is possible) that sites like ipify.org exist and are more useful.

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      1 Reply Last reply
      1
      • cw-kidC Offline
        cw-kidC Offline
        cw-kid
        wrote on last edited by cw-kid
        #9

        This trigger isn't working for me. I am getting a lot of false triggers where its saying my WAN IP address has changed when it hasn't.

        Sometimes it's showing a value of

        ${{ myIP.ip }}

        And then the rule fires suggesting the WAN IP has changed when it hasn't.

        I need the "changes" trigger to only trigger if its validated more than once or over a period of time, that the actual WAN IP address has changed and its not some blip or problem or slowness with it working out what the WAN IP really is.

        1 Reply Last reply
        0
        • LibraSunL Offline
          LibraSunL Offline
          LibraSun
          wrote on last edited by
          #10

          Good catch. Sounds like some other condition is called for, which either inspects the contents of myIP.ip for a suitable RegEx match (e.g. digits and dots) or verifies that the contained value is not NULL, or at least different from the literal ${{}} you experienced.

          1 Reply Last reply
          0
          • toggledbitsT Offline
            toggledbitsT Offline
            toggledbits
            wrote on last edited by
            #11

            That non-substituted value means that the expression failed. Check the log. I suspect that the query is failing from time to time, resulting in no data to myIP. That would also be in the log. The query failing will clear myIP, and that would make myIP.ip throw an evaluation error.

            This would be a good use for the ?. operator: myIP?.ip will return null if the fetch fails and myIP gets cleared, rather than throwing an error. You can then test for that null.

            Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

            1 Reply Last reply
            1
            • cw-kidC Offline
              cw-kidC Offline
              cw-kid
              wrote on last edited by
              #12

              I've changed the rule to use "myIP?.ip" instead that seems to still work OK and my current WAN IP is brought down from the online API request.

              As for the false triggering when the query is failing from time to time, I tried setting the trigger "for at least X secs"

              Expression Value: ip changes from 11.222.333.444 to (any) for at least 360 secs

              However this doesn't seem to work at all. I turned off my VPN and the WAN IP address changed, the rule that checks for the IP worked and the global expression contains the new IP address.

              However the other rule that is meant to trigger on expression value changes from specified IP to any other IP / value never fired.

              So I am not sure what is the best way to setup this trigger, so it works and doesn't false fire if the expression value goes to null / the http request query didn't happen to work that time.

              1 Reply Last reply
              0
              • LibraSunL Offline
                LibraSunL Offline
                LibraSun
                wrote on last edited by
                #13

                I was going to suggest the ol' "Sustained for __ seconds" trick, so glad you landed upon the same solution. Unclear why something would "stop working" just because of that. Have you checked the Logs? And is the secondary Rule enabled?

                cw-kidC 1 Reply Last reply
                0
                • LibraSunL LibraSun

                  I was going to suggest the ol' "Sustained for __ seconds" trick, so glad you landed upon the same solution. Unclear why something would "stop working" just because of that. Have you checked the Logs? And is the secondary Rule enabled?

                  cw-kidC Offline
                  cw-kidC Offline
                  cw-kid
                  wrote on last edited by
                  #14

                  @librasun If I removed the sustained for X seconds it starts "working" again but I am still getting false triggers though sometimes.

                  1 Reply Last reply
                  0
                  • cw-kidC Offline
                    cw-kidC Offline
                    cw-kid
                    wrote on last edited by
                    #15

                    Thought I'd try this one instead:

                    e3161ba3-2fe8-46bb-b1f2-68bef1a8bc2d-image.png

                    Is this a bug however ? I cannot set that to more than 60 seconds if I put in 360 seconds and save it reverts back to 60 seconds.

                    1 Reply Last reply
                    0
                    • toggledbitsT Offline
                      toggledbitsT Offline
                      toggledbits
                      wrote on last edited by
                      #16

                      The changes operator produces a pulsed output (otherwise you would never be notified of two or more changes sequentially). A pulsed output cannot be "sustained", because it only ever lasts 10ms or less.

                      Since you are testing "changes from expected to anything else", that's really not logically different from "not equal to expected". Use a plain equality/inequality. That will produce a sustained output for which the sustained for restriction can be used.

                      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                      cw-kidC 1 Reply Last reply
                      0
                      • toggledbitsT toggledbits

                        The changes operator produces a pulsed output (otherwise you would never be notified of two or more changes sequentially). A pulsed output cannot be "sustained", because it only ever lasts 10ms or less.

                        Since you are testing "changes from expected to anything else", that's really not logically different from "not equal to expected". Use a plain equality/inequality. That will produce a sustained output for which the sustained for restriction can be used.

                        cw-kidC Offline
                        cw-kidC Offline
                        cw-kid
                        wrote on last edited by cw-kid
                        #17

                        @toggledbits

                        OK thanks that makes sense.

                        I will not use "Changes" then in the trigger.

                        Instead I will try <> NOT expected value (IP address) and use a sustained for X secs.

                        1 Reply Last reply
                        1
                        • toggledbitsT Offline
                          toggledbitsT Offline
                          toggledbits
                          wrote on last edited by
                          #18

                          On my end I'll tighten up the UI so that option can't be selected when the changes operator is used.

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          1 Reply Last reply
                          2
                          • toggledbitsT toggledbits locked this topic on
                          Reply
                          • Reply as topic
                          Log in to reply
                          • Oldest to Newest
                          • Newest to Oldest
                          • Most Votes


                          Recent Topics

                          • [MSR] Rule do not fire
                            therealdbT
                            therealdb
                            0
                            3
                            60

                          • Rule condition shows TRUE in UI but Rule never transitions to SET — survives full restart
                            N
                            noelab
                            0
                            8
                            162

                          • DynamicGroupController and attributes
                            toggledbitsT
                            toggledbits
                            1
                            9
                            288

                          • Reactor (Multi-System/Multi-Hub) Announcements
                            toggledbitsT
                            toggledbits
                            5
                            149
                            137.6k

                          • Unofficial thread for compatibility
                            tunnusT
                            tunnus
                            2
                            2
                            732

                          • Ooops - Deleted Reactor Ex Machina II
                            toggledbitsT
                            toggledbits
                            0
                            2
                            87

                          • Bail out of failed reaction?
                            T
                            tamorgen
                            0
                            3
                            133

                          • Arming Envisalink panel from MSR
                            T
                            tamorgen
                            0
                            7
                            360

                          • [Solved] DynamicGroupController updating members issue
                            CrilleC
                            Crille
                            0
                            5
                            257

                          • Upgrade Issues
                            T
                            tbully
                            0
                            9
                            389

                          • [SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
                            toggledbitsT
                            toggledbits
                            0
                            10
                            500

                          • [SOLVED] Question regarding "in" vs "contains" vs contents of the string
                            G
                            gwp1
                            0
                            5
                            255
                          Powered by NodeBB | Contributors
                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                          • Login

                          • Don't have an account? Register

                          • Login or register to search.
                          • First post
                            Last post
                          0
                          • Categories
                          • Recent
                          • Tags
                          • Popular
                          • Unsolved