Good morning,
I have a service MQTT service that needs a restart occasionally. The add-on (Smartbed MQTT) is for the smart bed base for my bed. It has a "safety light" that I can control from HAAS & MSR as a light entity, and also moves the head of the bed to a preset at bedtime, and then lies it back flat in the morning The problem is, from time to time, the light becomes "unavailable" Restarting from the Add-ons tab in HAAS always fixes it, but I should be able to detect when it happens when "light.tempur_pedic_safety_lights" is not true or false, i.e., unavailable.
What I don't know how to do is how to restart that service. Does anybody have experience in restarting add-ons from MSR?
Running:
Reactor (Multi-hub) latest-24212-3ce15e25 ZWaveJSController [0.1.24232]HAAS:
RPi5-64 (8GB) Core 2024.7.3 Supervisor 2024.08.0 Operating System 13.0 Frontend 20240710.0Hi!
Is it possible to generate two additional log files, the first being the replica of what is displayed on screen by the Rule History widgets and the other with Recently Changed Entities?
And could I configure the generation of one file per day, and delete the older ones? For example, store the last 5 days?
And being more ambitious, does Windget have an icon to open these TXT files in the navigated?
Well, we're approaching Christmas, so here's my request to Santa Claus @toggledbits 🙂
Hi @toggledbits
I'm working on a controller to generate llm response from a prompt in reactor. I have http response coming thru an http request action at the moment, capturing the response inside a local variable. So, it's practically sync.
I want to create a controller, so I don't have to rely on a proxy (and have a simpler architecture), and duplicate absurd http actions, but AFAIK in the current implementation, actions are async only. But if I have multiple requests going on, I cannot be sure what it's really inside an attribute. I also thought that something like a correlation id when sending the request could be used to identity multiple responses, but I wanted to double check with you before starting with something too complicated. I also noticed that some actions in home assistant (ie forecast) are sync and I'm wondering if you have any plan or hint to address this situation. Thanks.
Thanks.
@togglebits I am curious as to why the tilt_sensor.state (primary) = NULL. I believe it should show true or false. I have to use binary_sensor.state instead in my rules.
Again, not sure if this is related to Reactor/ZwaveJSController implementation or the actual Z-Wave JS UI docker version. I have copied, below, the attributes of the tilt sensor in hopes it can help.
Thanks in advance.
Reactor version 23302
ZWaveJSController version 23254
Z-Wave JS UI version 9.3.0.724519f
zwave-js version 12.2.3
@toggledbits I have noticed after upgrading both Reactor and ZWaveJSController to version 24257 that two of my devices/entities, TILT-ZWAVE2.5-ECO and Zooz ZSE18, had their entity re-named in an unusual way and also appears to be duplicated.
Reactor version 24257
ZWaveJSController version 24257
Z-Wave JS UI version 9.18.1
zwave-js version 13.2.0
Vestibule Motion Sensor State attributes/partial screenshot of entities it created. All entities have the same attributes.
motion_sensor.state=true x_zwave_values.Notification_Home_Security_Motion_sensor_status=8 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=23 zwave_device.valueId=[113,"Notification","Home Security","Home Security","Motion sensor status","Motion sensor status"] zwave_device.version_info=nullTilt Sensor Door State and Tilt Sensor Door State Simple attributes/partial screenshot of entities it created. All entities have similar attributes with exception of x_zwave_values.Notification_Access_Control_Door_State = 22 or 23.
tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state_simple=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state_simple=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=nullI'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only).
Anyway, here's my reactor-mqtt-contrib package:
Contrib MQTT templates for Reactor. Contribute to dbochicchio/reactor-mqtt-contrib development by creating an account on GitHub.
Simply download yaml files (everything or just the ones you need) and you're good to go.
I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them.
The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression.
Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests 🙂
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.Hi @toggledbits.
After a couple of weeks, I noticed that my Remotec zrc90 isn't working as expected.
Scenes are working in ZWaveJS, but this device has a strange behavior: the scene change, but then it's set again to null. In Reactor, this remains null:
battery_power.level=0.7 battery_power.since=1725817957361 x_debug.dt={"description":"Scene master 8 button remote","model":"BW8510/ZRC-90US","default_name":"Scene master 8 button remote","manufacturerId":21076,"productType":0,"productId":34064} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=70 x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_scene_003=null x_zwave_values.Central_Scene_scene_004=null x_zwave_values.Central_Scene_scene_005=null x_zwave_values.Central_Scene_scene_006=null x_zwave_values.Central_Scene_scene_007=null x_zwave_values.Central_Scene_scene_008=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Manufacturer_Specific_manufacturerId=21076 x_zwave_values.Manufacturer_Specific_productId=34064 x_zwave_values.Manufacturer_Specific_productType=1 x_zwave_values.Version_firmwareVersions=["1.1","1.1"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=2 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=0 zwave_device.capabilities=[91,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Remote Controller" zwave_device.impl_sig="24242:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=false zwave_device.is_secure=false zwave_device.manufacturer_info=[21076,1,34064] zwave_device.max_data_rate=null zwave_device.node_id=154 zwave_device.specific_class="Simple Remote Control" zwave_device.status=2 zwave_device.status_text="awake" zwave_device.version_info=[null,"1.1"] zwave_device.wakeup_interval=0Anything I could look at? Thanks.
Hi, @toggledbits!
I have a question about the execution behavior. See the code below, and I'll explain the situation.
12957c3e-ff06-46c9-929d-b53f936665df-image.png
This is a routine that, at a certain point, determines that the desktop on which the VM hosting the Reactor is located receives an instruction to perform a shutdown (Shell Command).
When this happens, the desktop is turned off, and then Hubitat detects by a "ping" that the VM has been down, waits 15 seconds, turns off the power to this desktop, and then 15 seconds later turns on the desktop with the Reactor VM again.
After restarting the desktop, the VM is loaded, and the Reactor is triggered. Still, the following problem occurs: I expected that when the rule was continued to be executed again, the next step would be executed, that of the 900-second delay after shutdown, but the Shell command is executed again, and then it goes into a loop, the rule does not advance.
To break the loop, I first have to make the VM not load, change the desktop password, and then start the VM. In this case, Reactor generates an error when trying to execute the Shell Command because of the invalid password and then finishes the routine following the 900 delay step.
b58b0d4a-d6c1-4fe3-bab7-4222acea9607-image.png
Is my interpretation that when it returns, the routine should continue to the next step that has not yet been executed incorrectly? Or does Reactor, through the shutdown command, interpret that it hasn't finished this step and keep trying, which is the correct reaction?
Thanks for clarifying.
Hi @toggledbits ,
I'm slowly moving my ZWave network from Vera to ZWaveJS. I successfully cloned my ZWave network using a spare Vera Edge (a new post for the community later when I'll be fully back from vacation) and I'm testing a couple of things before moving everything to ZWaveJS.
In the meanwhile, I have a couple of venetian blinds connected to Fibaro Roller Shutters 2 (FGR222) and I'm using some proprietary ZWave commands to control the tilt position, that right now I'm sending via Vera (with some code from the old place, messing with this):
af7f883c-f49e-419c-a2fe-8669572e3792-image.png
The ZWaveJS values are reported via this:
x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsPosition=0 x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsTilt=0I hope there's a way to expose a separate device to control the tilt position directly, without doing the mess I'm doing now. Let me know if you need some files. Thanks.
As per @toggledbits request, new topic.
Position and cover commands not working and position/cover attributes are incorrect. Dimming is OK.
cover.state=null dimming.level=1 dimming.step=0.1 energy_sensor.units="kWh" energy_sensor.value=0.41 position.value=null power_sensor.units="W" power_sensor.value=0 power_switch.state=true x_debug.dt={"entity_class":"Cover","match":"deviceClass.generic.key=17;deviceClass.specific.key=6","capabilities":["cover","toggle","position"],"primary_attribute":"cover.state"} x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.41 x_zwave_values.Meter_value_66049=0 x_zwave_values.Multilevel_Switch_Down=null x_zwave_values.Multilevel_Switch_Up=null x_zwave_values.Multilevel_Switch_currentValue=99 x_zwave_values.Multilevel_Switch_duration="unknown" x_zwave_values.Multilevel_Switch_restorePrevious=null x_zwave_values.Multilevel_Switch_targetValue=99 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_System_Hardware_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null zwave_device.capabilities=[38,50,113] zwave_device.endpoint=1 zwave_device.failed=null zwave_device.impl_sig="24225:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=148 zwave_device.version_info=nullThanks!
Another one for you, @toggledbits.
I have two water sensors (same device, NAS-WS01Z), but one is reporting leak_detector.state=true even if no alarm is detected (I double checked from ZWaveJS UI):
battery_power.level=0.86 battery_power.since=null leak_detector.state=true x_debug.dt={"entity_class":"Notification Sensor","match":"deviceClass.generic.key=7"} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=86 x_zwave_values.Binary_Sensor_Water=false x_zwave_values.Configuration_Alarm_Activity_Duration=5 x_zwave_values.Configuration_Alarm_Beep=1 x_zwave_values.Configuration_Alarm_Duration=120 x_zwave_values.Configuration_Alarm_Interval=null x_zwave_values.Configuration_Basic_Set_Level=255 x_zwave_values.Configuration_First_Alarm_Activity_Duration=null x_zwave_values.Configuration_Water_Detection=1 x_zwave_values.Manufacturer_Specific_manufacturerId=600 x_zwave_values.Manufacturer_Specific_productId=4229 x_zwave_values.Manufacturer_Specific_productType=3 x_zwave_values.Notification_Water_Alarm_Sensor_status=null x_zwave_values.Notification_alarmLevel=0 x_zwave_values.Notification_alarmType=0 x_zwave_values.Version_firmwareVersions=null x_zwave_values.Version_hardwareVersion=null x_zwave_values.Version_libraryType=null x_zwave_values.Version_protocolVersion=null x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=43200 zwave_device.capabilities=[48,112,113,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Notification Sensor" zwave_device.impl_sig="24225:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.last_wakeup=1724143899220 zwave_device.manufacturer_info=[600,3,4229] zwave_device.max_data_rate=null zwave_device.node_id=114 zwave_device.specific_class="Notification Sensor" zwave_device.status=1 zwave_device.status_text="asleep" zwave_device.version_info=[null,null] zwave_device.wakeup_interval=43200here's the other one, correctly report the leak status:
battery_power.level=1 battery_power.since=null leak_detector.state=false x_debug.dt={"entity_class":"Notification Sensor","match":"deviceClass.generic.key=7"} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=100 x_zwave_values.Binary_Sensor_Water=false x_zwave_values.Configuration_Alarm_Activity_Duration=5 x_zwave_values.Configuration_Alarm_Beep=1 x_zwave_values.Configuration_Alarm_Duration=120 x_zwave_values.Configuration_Alarm_Interval=1 x_zwave_values.Configuration_Basic_Set_Level=255 x_zwave_values.Configuration_First_Alarm_Activity_Duration=60 x_zwave_values.Configuration_Water_Detection=1 x_zwave_values.Manufacturer_Specific_manufacturerId=600 x_zwave_values.Manufacturer_Specific_productId=4229 x_zwave_values.Manufacturer_Specific_productType=3 x_zwave_values.Notification_Water_Alarm_Sensor_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null x_zwave_values.Version_firmwareVersions=["2.54"] x_zwave_values.Version_hardwareVersion=48 x_zwave_values.Version_libraryType=6 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=43200 zwave_device.capabilities=[48,112,113,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Notification Sensor" zwave_device.impl_sig="24225:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.last_wakeup=1724105239533 zwave_device.manufacturer_info=[600,3,4229] zwave_device.max_data_rate=null zwave_device.node_id=113 zwave_device.specific_class="Notification Sensor" zwave_device.status=1 zwave_device.status_text="asleep" zwave_device.version_info=[null,"2.54"] zwave_device.wakeup_interval=43200Also, both seems to have no primary value. Thanks.
Hi-
I have an android media player entity publishing from HA. I watch for changes in transport state and media title to trigger some actions.
Though those attributes report as expected, the set rule is being throttled for possible flapping.
There is an attribute for media position that continually updates, I suspect it is causing the evaluations to run constantly.
The workaround I am seeking is to ignore those attributes in HA or MSR. Anyone know how, or have a better idea??
Thx
Btw- this problem has spanned versions of HA and reactor, but I am current on both. Too current on HA for transparency, but the issue has survived several updates.
Referencing an expression inside a reaction is in the form of ${{ expression }}. When referenced inside my shell command to set the watering delay duration for my Rachio sprinkler system, it just does not work.
If I enter "86400" instead of referencing the expression lWateringDelayDuration, it works. Either I am doing something wrong or referencing an expression inside a shell command is not supported.
Reactor version: 24212
Local Expression
lWateringDelayDuration =
Setting Reaction using Shell command
curl -X PUT -H "Content-Type: application/json" -H "Authorization: Bearer xxxxxxxxxx -d '{ "id" : "xxxxxxxxxx", "duration" : ${{ lWateringDelayDuration}} }' https://api.rach.io/1/public/device/rain_delayThanks in advance
As per @toggledbits request, here's a new topic.
My Fibaro Door Window Sensor 2 (FGDW002) is always reporting as open, even if
x_zwave_values.Notification_Access_Control_Door_state=23 x_zwave_values.Notification_Access_Control_Door_state_simple=23which means that the door is closed. It was working before and I could downgrade to test, if necessary. Thanks.
Hi @toggledbits,
I'm not sure if it's a bug or something, but I have a lot of Fibaro Double Switch (FGS223) as follows.
In the example, it's zwavejs>65-2:
energy_sensor.units="kWh" energy_sensor.value=0.21 power_sensor.units="W" power_sensor.value=0 power_switch.state=false x_debug.dt={"entity_class":"Switch","match":"deviceClass.generic.key=16","capabilities":["power_switch","toggle"],"primary_attribute":"power_switch.state"} x_zwave_values.Binary_Switch_currentValue=false x_zwave_values.Binary_Switch_targetValue=false x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.21 x_zwave_values.Meter_value_66049=0 zwave_device.capabilities=[37,50] zwave_device.endpoint=2 zwave_device.failed=null zwave_device.impl_sig="23326:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=65 zwave_device.version_info=nullWhen operating endpoint 2, it's triggered endpoint 1. Endpoint 1 is fine. This is causing a lot of troubles, as you may imagine.
Also, endpoint 0 is not really a switch, and the associated actions are not doing anything at all. Maybe these could be removed. Also, I see battery_maintenance and power_source capabilities, all with null values.
battery_maintenance.charging=null battery_maintenance.rechargeable=false battery_maintenance.replace=false battery_maintenance.state=null heat_detector.state=false power_source.source=null power_switch.state=null x_debug.dt={"entity_class":"Switch","match":"deviceClass.generic.key=16","capabilities":["power_switch","toggle"],"primary_attribute":"power_switch.state","description":"Double Switch 2","model":"FGS223","default_name":"Double Switch 2","manufacturerId":271,"productType":515,"productId":4096} x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Configuration_First_Channel_Energy_Reports_Threshold=100 x_zwave_values.Configuration_First_Channel_Operating_Mode=0 x_zwave_values.Configuration_First_Channel_Power_Reports_Minimum_Time_Between_Reports=10 x_zwave_values.Configuration_First_Channel_Power_Reports_Threshold=20 x_zwave_values.Configuration_First_Channel_Pulse_Time_for_Blink_Mode=5 x_zwave_values.Configuration_First_Channel_Reaction_to_Key_S1_for_Delay_Auto_ON_OFF_Modes=0 x_zwave_values.Configuration_First_Channel_Time_Parameter_for_Delay_Auto_ON_OFF_Modes=50 x_zwave_values.Configuration_General_Purpose_Alarm_Response=3 x_zwave_values.Configuration_Include_Consumption_By_Device_Itself_in_Reports=0 x_zwave_values.Configuration_Input_Button_Switch_Configuration=2 x_zwave_values.Configuration_Key_S1_Associations_Double_Click_Value_Sent=99 x_zwave_values.Configuration_Key_S1_Associations_Send_OFF_With_Single_Click_2=0 x_zwave_values.Configuration_Key_S1_Associations_Send_ON_With_Single_Click_1=0 x_zwave_values.Configuration_Key_S1_Associations_Send_When_Double_Clicking_8=0 x_zwave_values.Configuration_Key_S1_Associations_Send_When_Holding_and_Releasing_4=0 x_zwave_values.Configuration_Key_S1_Associations_Switch_OFF_Value_Sent=0 x_zwave_values.Configuration_Key_S1_Associations_Switch_ON_Value_Sent=255 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Held_Down_and_Released_8=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_1_Time_1=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_2_Times_2=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_3_Times_4=1 x_zwave_values.Configuration_Key_S2_Associations_Double_Click_Value_Sent=99 x_zwave_values.Configuration_Key_S2_Associations_Send_OFF_With_Single_Click_2=0 x_zwave_values.Configuration_Key_S2_Associations_Send_ON_With_Single_Click_1=0 x_zwave_values.Configuration_Key_S2_Associations_Send_When_Double_Clicking_8=0 x_zwave_values.Configuration_Key_S2_Associations_Send_When_Holding_and_Releasing_4=0 x_zwave_values.Configuration_Key_S2_Associations_Switch_OFF_Value_Sent=0 x_zwave_values.Configuration_Key_S2_Associations_Switch_ON_Value_Sent=255 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Held_Down_and_Released_8=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_1_Time_1=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_2_Times_2=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_3_Times_4=1 x_zwave_values.Configuration_Periodic_Active_Power_Reports=3600 x_zwave_values.Configuration_Periodic_Energy_Reports=3600 x_zwave_values.Configuration_Report_During_Blink_Mode=0 x_zwave_values.Configuration_Second_Channel_Energy_Reports_Threshold=100 x_zwave_values.Configuration_Second_Channel_Operating_Mode=0 x_zwave_values.Configuration_Second_Channel_Power_Reports_Minimum_Time_Between_Reports=10 x_zwave_values.Configuration_Second_Channel_Power_Reports_Threshold=20 x_zwave_values.Configuration_Second_Channel_Pulse_Time_for_Blink_Mode=5 x_zwave_values.Configuration_Second_Channel_Reaction_to_Key_S2_for_Delay_Auto_ON_OFF_Modes=0 x_zwave_values.Configuration_Second_Channel_Time_Parameter_for_Delay_Auto_ON_OFF_Modes=50 x_zwave_values.Configuration_Send_Secure_Commands_to_2nd_Association_Group_1=1 x_zwave_values.Configuration_Send_Secure_Commands_to_3rd_Association_Group_2=1 x_zwave_values.Configuration_Send_Secure_Commands_to_4th_Association_Group_4=1 x_zwave_values.Configuration_Send_Secure_Commands_to_5th_Association_Group_8=1 x_zwave_values.Configuration_Smoke_CO_or_CO2_Alarm_Response=3 x_zwave_values.Configuration_State_After_Power_Failure=1 x_zwave_values.Configuration_Temperature_Alarm_Response=1 x_zwave_values.Configuration_Time_of_Alarm_State=600 x_zwave_values.Configuration_Water_Flood_Alarm_Response=2 x_zwave_values.Manufacturer_Specific_manufacturerId=271 x_zwave_values.Manufacturer_Specific_productId=4096 x_zwave_values.Manufacturer_Specific_productType=515 x_zwave_values.Notification_Heat_Alarm_Heat_sensor_status=0 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null x_zwave_values.Protection_exclusiveControlNodeId=null x_zwave_values.Protection_local=0 x_zwave_values.Protection_rf=0 x_zwave_values.Protection_timeout=null x_zwave_values.Version_firmwareVersions=["3.2"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=3 x_zwave_values.Version_protocolVersion="4.5" zwave_device.capabilities=[91,112,113,114,117,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Binary Switch" zwave_device.impl_sig="23326:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=true zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.manufacturer_info=[271,515,4096] zwave_device.max_data_rate=null zwave_device.node_id=65 zwave_device.specific_class="Binary Power Switch" zwave_device.status=4 zwave_device.status_text="alive" zwave_device.version_info=[null,"3.2"]Thanks.
Good morning,
I'm having an issue with controlling my Zooz Zen14 outdoor double outlet. I should be able to control each outlet individually, and this does work when use Home Assistant (haas) from Reactor.
When I use zwavejs, I see 3 entries:
8305eccf-a99e-421f-ad18-1f08da9c8c9c-image.png
The first entry is for the overall device. I can turn both outlets on and off (in theory) by setting the power_switch state to on or off. This does turn them on and off when using zwavejs.
When I go to the individual outlets, performing the power_switch.on or power_switch.off actions turns them all (main, 1 and 2) on or off, and not just the individual outlets. When I perform the same action from haas, turning on outlet 1 will turn on the main switch and 1, but not 2.
I reviewed the logs for that node and I'm not seeing anything obvious.
:~/reactor/logs$ cat reactor.log.1 | grep ZWaveJSController#zwavejs | grep "node 216" [latest-24212]2024-08-07T00:19:00.233Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "endpoint": 0, "property": "targetValue", "newValue": true, "prevValue": false, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:00.235Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 0, "newValue": true, "prevValue": false, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:00.321Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 0, "newValue": true, "prevValue": true, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:00.322Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "targetValue", "endpoint": 0, "newValue": true, "prevValue": true, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:00.323Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:duration:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "duration", "endpoint": 0, "newValue": { "value": 0, "unit": "seconds" }, "prevValue": { "value": 0, "unit": "seconds" }, "propertyName": "duration" } } [latest-24212]2024-08-07T00:19:02.189Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 1, "newValue": true, "prevValue": false, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:02.192Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "targetValue", "endpoint": 1, "newValue": true, "prevValue": false, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:02.193Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:duration:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "duration", "endpoint": 1, "newValue": { "value": 0, "unit": "seconds" }, "prevValue": { "value": 0, "unit": "seconds" }, "propertyName": "duration" } } [latest-24212]2024-08-07T05:32:30.127Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 0 (entity "216-0") [latest-24212]2024-08-07T05:32:30.127Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 1 (entity "216-1") [latest-24212]2024-08-07T05:32:30.128Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 2 (entity "216-2")I'm running:
Reactor (Multi-hub) latest-24212-3ce15e25
ZWaveJSController [0.1.23326] (with zwavejs_data from 7/25/2024)
HA:
Core 2024.7.3
Supervisor 2024.08.0
Operating System 12.3
Frontend 20240710.0
Feature request on reactions side.
-
For starters,
you've put spaces between(edit: extra spaces should be OK)buttonCodes
and the[
which will not be interpreted correctly.
Look above at my original example: the syntax isbuttonCodes[index]
with no spaces.Secondly, your definition of
buttonCodes
itself shows just a long comma-separated list, which cannot work as is. To make it an array, it must start with[
and end with]
.Third, you reference
buttonCodes
in other variables, but named the expressionButtonCodes
which is different. These things must match exactly.Fourth, some of your
CharacterN
definitions result in alphanumeric characters which are NOT "just 0 through 9" -- like "x" or "." -- hence they CANNOT serve as theindex
for an array lookup. Another approach is needed (example: use an Object, per the suggestion below).This is proving more challenging than expected -- even turning everything into an Object would pose its own hazards at this point -- but getting the syntax right is way more than half the battle!
-
Also note that the data type of most of the index expressions is a string. Use
int()
to make sure it's a number: C1 =ButtonCodes[ int( Character1 ) ]
Also, it may be useful to break everything out this way while you're testing and figuring it out, but ultimately, you may want to combine them: C1 =
ButtonCodes[ int( substr( Channel, 0, 1 ) ) ]
-
The X's are just left over remnants of the lua process I was using. It was just padding and acted a indicator that the channel was at a end and stop the process. So channel 7.1 would come over as 7.1xx. I set 5 characters to accommodate a 5 digit channel i.e. 135.1 I will take a look at your suggestions.
-
One technique I use involves setting up to "parallel" arrays, an example of which I'll outline here without explicit reference to the problem at hand. I hope to share the mechanics of it without clutter...
value_I_have := getEntity(vera>source).parameter.i.want // result is "y" array_of_values := ["x","y","z"] // all possible input values listed in some order array_of_codes := ["0123","2345","3456"] // desired converted output values for "x", "y" and "z" buttonPush := array_of_codes[ indexOf (array_of_values, value_I_have) ]
Let that sink in a bit. In fact, if I were you @Tarkus , I'd mess around with abbreviated versions of this example in a throwaway Rule, just to get the feel for how each input affects the output.
-
@tarkus said in Feature request on reactions side.:
@librasun yes i do that often
That avoids the "trick" of trying to let
Character1
stand in as a numeric value (i.e. serving as anindex
to anarray
), since we now know that it may be alphabetical. -
@tarkus said in Feature request on reactions side.:
I thought a period was considered numeric in programing to accommodate decimals.
Your assumption is correct, however the intent was to let your deciphered "digits" (which I was misled to believe were strictly 0 through 9) stand as "numbers" in the expression
buttonCodes[ ]
, whereasbuttonCodes[ . ]
andbuttonCodes["x"]
simply make no sense in that context.Hence the need for parallel lookups.
-
@librasun said in Feature request on reactions side.:
whereas buttonCodes[ . ] and buttonCodes["x"] simply make no sense.
These are actually OK if
buttonCodes
is an object, not an array. You can use the square-bracket notation same as dot member access, sobuttonCodes[ "x" ]
(note the quotes so it's a string) is the same asbuttonCodes.x
. Using the square bracket notation lets you use a variable for the member name. You don't need a second array, you just need to structurebuttonCodes
correctly...buttonCodes = { '0': 'codes for 0', '1': 'codes for 1', '.': 'codes for dot' } key_to_send = "." # or whatever/however you get the key send_data = buttonCodes[ key_to_send ]
-
@toggledbits said in Feature request on reactions side.:
You don't need a second array, you just need to structure
buttonCodes
correctly...I completely agree. If I could turn back time knowing what I know now about this scenario, I would definitely have chosen an Object. It's concise, easy to edit, employ, etc. I just didn't wanna yank @Tarkus around by the nose after we've come this far, lol.
-
@toggledbits , since we're on the topic of Objects, I've been meaning to ask:
Is there any chance you'd consider implementing athis
self-reference for Objects, so I could in theory build:obj := {'noun':'cat','verb':'plays','sentence':'The ' + this.noun + ' ' + this.verb}
Maybe that's cray-cray, but I've already bumped into a couple of occasions where it could be handy.
REFERENCE: https://www.w3schools.com/js/js_this.asp
-
That's not really the way
this
works for objects in any language I've ever seen or used. We keep using the term "object" here, because of JavaScript, but I really prefer the Python term "dictionary", and maybe I'm going to start using that instead (the grammar actually does, but somehow that didn't make the leap to the documentation and followed the JS nomenclature instead). It's not an object in the sense that there's class definition associated with it, it's just a collection of key/value pairs. Even in JavaScript for many versions, an "object" was really a fancy dictionary, and it is only the more recent versions where that is being formalized, but of course, for compatibility, they are forced to support the old model for some time. -
@librasun said in Feature request on reactions side.:
Secondly, your definition of buttonCodes itself shows just a long comma-separated list, which cannot work as is. To make it an array, it must start with [ and end with ].
Yeah i had the brackets but it did not work so the absence of of them is just me trying different things and not knowing what I am doing. LOL
-
@toggledbits said in Feature request on reactions side.:
whereas buttonCodes[ . ] and buttonCodes["x"] simply make no sense.
These are actually OK if buttonCodes is an object, not an array. You can use the square-bracket notation same as dot member access, so buttonCodes[ "x" ] (note the quotes so it's a string) is the same as buttonCodes.x. Using the square bracket notation lets you use a variable for the member name. You don't need a second array, you just need to structure buttonCodes correctly...
buttonCodes = { '0': 'codes for 0', '1': 'codes for 1', '.': 'codes for dot' }
key_to_send = "." # or whatever/however you get the key
send_data = buttonCodes[ key_to_send ]I ended up using this method and it works great!
Thanks for all the help.
-