[Solved] DynamicGroupController updating members issue
CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Arming Envisalink panel from MSR
T
Topic thumbnail image
Multi-System Reactor
Upgrade Issues
T
Topic thumbnail image
Multi-System Reactor
[SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
G
Topic thumbnail image
Multi-System Reactor
[SOLVED] Question regarding "in" vs "contains" vs contents of the string
G
Topic thumbnail image
Multi-System Reactor
Logon screen timeout
G
Noticing since 170 that the lock screen doesn't switch to the logon prompt but, rather, stays on the active UI until such time as you go to click something within it. Then it jumps to the login screen. Brave browser Brave 1.92.139 (Official Build) (arm64) Chromium: 150.0.7871.114
Multi-System Reactor
[MSR] Copy&past of actions and/or drag&drop between set/reset
therealdbT
Hey @toggledbits One thing that bothers me while doing work on new systems/new features, is that I cannot copy&paste actions, and I cannot drag&drop between set and resets. #1 is for when I want to copy an action between different rules opened in two separate browser windows, while #2 is when I just need to flip a bunch of actions in the reset, or move some logic back and forth. Both will be appreciated, but I understand the technical challenges. Thanks!
Multi-System Reactor
Upgrade advice - upgrade from aarch64 to ARM64 image
T
I'm currently on version 26011. I understand that the aarch64 image is no longer supported. So, I therefore need to update to the ARM64 image. Can anyone possibly suggest how I update my docker compose.yaml file (see below). Ideally I'd like to keep my existing reactions etc. rather than start from scratch. # Multi-System Reactor template docker-compose.yml (version 22160) # # Change the lines indicated by "DO"... # services: reactor: container_name: reactor environment: # DO change the TZ: line to set your local time zone. # See valid TZ list: https://en.wikipedia.org/wiki/List_of_tz_database_time_zones TZ: GB # # DO NOT change this path. Your directory location is in "source" below. REACTOR_DATA_PREFIX: /var/reactor # DO change the image below to the one you are using (e.g. armv7l or aarch64 for RPi 4) image: toggledbits/reactor:latest-aarch64 restart: "always" expose: - 8111 ports: - 8111:8111 volumes: # DO change the /home/username/reactor below to the directory you created for # your local data; DO NOT change the /var/reactor part - /home/pi/docker/reactor:/var/reactor - /etc/localtime:/etc/localtime:ro tmpfs: /tmp
Multi-System Reactor
Alexa for MSR, any interest?
MikeReadingtonM
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Telegram notification broke with latest update
3
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Phantom device, “INFO” appears
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Mode Status NULL
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] HTTP query failing after version 26177
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Question about the find function
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[Answered] OK to remove old json files?
3
Topic thumbnail image
Multi-System Reactor
Deprecation Announcement: 32-bit ARM *docker* images
toggledbitsT
If you are using the armv7l docker image, the OpenJS Foundation that publishes node is no longer producing 32-bit builds as of v24. That means the last supported LTS version of node for armv7l is v22, which will go End-of-Life in May 2027. Therefore, the Reactor armv7l image is now deprecated and will only be produced until node v22 goes EOL, and I will not publish armv7l images beyond that date. If you are running an RPi 3 or earlier with Reactor, you are on this image, and will need to upgrade hardware to a 64-bit model and use the arm64 image. If you need help getting it done, ask in this category.
Multi-System Reactor
[Solved] build 26150 - engine not starting
G
@toggledbits I pulled the image (well, Watchtower did) and within minutes the whole system went offline. The log looks like it ends with 26143. [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-mkahsmgf/26qq82mw-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lqyfljfi/22f8on0t-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lsb61rw8/24oenqi2-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/rule-lrh58he0:S-1c00gfib-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/1c00dylr-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/1nam9w5u-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-miuh2qqi/22ls4lql-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-kwc6rmci/rule-kwc6rmci:S-1vj8sdfc-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-kwc6rmci/rule-kwc6rmci:S-1qanz01x-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/24lq19p6-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-mk0o8iox/23oy468y-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-miscg2h3/rule-miscg2h3:S-22gmbq1c-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-kxgrfjke/238p0old-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-m7ccsso5/re-m7ccsso5-1r0myjxa-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/19nl9wq2-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/rule-ladyja6a:S-yl3xk9t-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/rule-ladyja6a:S-yl3vv5m-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-ln7j2nqp/re-ln7j2nqp-22mx9lzd-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-ln7j2nqp/22mx87c8-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-licneppy/1mzwe7ht-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ml3194ih/25jqt1j4-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-kxgrg7kf/227hshak-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-reactorexmachina/13ua1p95-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-reactorexmachina/13uagam7-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-grpvl9oypg/rule-grpvl9oypg:R-134x4cbv-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-grpvl9oypg/rule-grpvl9oypg:R-134x2fyl-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-lscjrws1/238p5c22-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lbwr0jvq/1xkczf03-cons [latest-26143]2026-05-31T15:23:44.547Z <Structure:NOTICE> Structure Structure#1 stopped [latest-26143]2026-05-31T15:23:44.547Z <app:NOTICE> Closing APIs... [latest-26143]2026-05-31T15:23:44.547Z <wsapi:NOTICE> wsapi: closing... [latest-26143]2026-05-31T15:23:44.547Z <wsapi:NOTICE> wsapi: disconnecting from "192.168.1.23#82" (1001 service closing) [latest-26143]2026-05-31T15:23:44.548Z <httpapi:NOTICE> HTTP API closing... [latest-26143]2026-05-31T15:23:44.549Z <wsapi:NOTICE> wsapi: server closed [latest-26143]2026-05-31T15:23:44.549Z <httpapi:INFO> HTTP server closed. [latest-26143]2026-05-31T15:23:44.549Z <app:NOTICE> Stopping timers... [latest-26143]2026-05-31T15:23:44.551Z <app:null> Shutdown complete, process ID 1 [latest-26143]2026-05-31T15:23:44.551Z <app:null> Closing logs... [latest-26143]2026-05-31T15:23:44.551Z <default:null> Closing log I can SSH to the VM. Alas, I do not have the previous image for 26143 as I'm a little too quick sometimes on housekeeping.
Multi-System Reactor
http request action & digest auth
tunnusT
I’m using the HTTP Request action in MSR and need to authenticate against an endpoint that uses HTTP Digest authentication. Now that endpoint was changed to use SHA-256 in digest auth, so I would like to know if MSR supports it, or is it limited to MD5-based digest auth?
Multi-System Reactor

MSR if you have only one system

Scheduled Pinned Locked Moved Multi-System Reactor
11 Posts 5 Posters 2.0k Views 5 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • CatmanV2C Offline
    CatmanV2C Offline
    CatmanV2
    wrote on last edited by
    #1

    As above really

    Watching the MSR threads. Is there a benefit / should I look to move to MSR if I only have (and likely at this point only intend to have) one system (i.e. OpenLuup)

    Just curious, really

    C

    The Ex-Vera abuser know as CatmanV2.....

    1 Reply Last reply
    0
    • 3 Offline
      3 Offline
      3rdStng
      wrote on last edited by
      #2

      My vote is yes. I was/am running Vera, which we all know is slow and gets bogged down at times. Moving my Reactor for Vera off to its own docker was a huge performance lift in the Vera. I continued to move all of my scenes off next. I now have a Hubitat and Vera, but each are only there for control of the device itself. All my scenes, schedules, modes, etc. are all managed and run by MSR.

      1 Reply Last reply
      1
      • CatmanV2C Offline
        CatmanV2C Offline
        CatmanV2
        wrote on last edited by
        #3

        Yep, that makes sense.

        Except I don't have Vera. Everything I have is running in Reactor on an Intel NUC with OpenLuup on Debian....

        C

        The Ex-Vera abuser know as CatmanV2.....

        1 Reply Last reply
        0
        • 3 Offline
          3 Offline
          3rdStng
          wrote on last edited by
          #4

          I just noticed your signature line. That's funny. I realize you don't have Vera. For me though, getting all the routines and everything vendor neutral has made it super simple for me to move/migrate devices between hubs. And the family doesn't know. My only hold up right now is an easy to use and easy to configure dashboard. But I've got a plan for that. Just need to do a bulk migration one day of a group of sensors. I look forward to the day that MSR has its Dashboard running.

          MatohlM 1 Reply Last reply
          1
          • toggledbitsT Offline
            toggledbitsT Offline
            toggledbits
            wrote on last edited by toggledbits
            #5

            If you are using openLuup as a single system, that resolves many of the performance issues of the Vera itself (it makes an acceptable radio for the devices it can support, as we all know). There are pros and cons to moving to MSR in this kind of scenario.

            You are bridged, meaning there is a socket-based tunnel between the Vera and openLuup to get the Vera devices into openLuup. If you introduce MSR into the equation, then there are three possibilities: (1) you configure MSR to talk to the Vera directly, in which case MSR brings the Vera devices in and lets you run the rules, etc., but it can't see the openLuup devices (only relevant if there are other plugins/devices on openLuup that you need access to from MSR); (2) you configure MSR to talk to openLuup, in which case you have all of your Vera and openLuup devices available in MSR, but MSR is talking to the Vera devices over a bridge to openLuup that is talking to the Vera devices over the bridge to Vera (bridge to a bridge, not very efficient); (3) you connect MSR to both, in which case you have all the devices from both like #2, with the option of talking to the Vera devices more directly, but confusion may set in because all of the Vera devices will appear as both the native Vera entities and bridged openLuup entities -- every Vera device is listed in MSR once for its appearance on Vera and again for its appearance in openLuup.

            The biggest con to staying on the Reactor plugin (for Vera/openLuup) is that I have no further development planned for it. As new features go into MSR, I have no plans to "back port" them into R4V. As Vera is "walking dead", so is every Vera plugin, including R4V.

            Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

            CatmanV2C 1 Reply Last reply
            0
            • 3 3rdStng

              I just noticed your signature line. That's funny. I realize you don't have Vera. For me though, getting all the routines and everything vendor neutral has made it super simple for me to move/migrate devices between hubs. And the family doesn't know. My only hold up right now is an easy to use and easy to configure dashboard. But I've got a plan for that. Just need to do a bulk migration one day of a group of sensors. I look forward to the day that MSR has its Dashboard running.

              MatohlM Offline
              MatohlM Offline
              Matohl
              wrote on last edited by
              #6

              @3rdstng I have walked the HA route instead of Openluup. Vera for the devices that are supported by it and HA for the ones that are not supported by Vera. I have connected MSR directly to Vera and the same for HA to Vera which means I see them twice in MSR as described above which could sometimes lead to some confusion. However, I use MSR for all the rules and HA for its very flexible dashboards and support to devices that are not (and will not be) supported by Vera.

              1 Reply Last reply
              0
              • toggledbitsT toggledbits

                If you are using openLuup as a single system, that resolves many of the performance issues of the Vera itself (it makes an acceptable radio for the devices it can support, as we all know). There are pros and cons to moving to MSR in this kind of scenario.

                You are bridged, meaning there is a socket-based tunnel between the Vera and openLuup to get the Vera devices into openLuup. If you introduce MSR into the equation, then there are three possibilities: (1) you configure MSR to talk to the Vera directly, in which case MSR brings the Vera devices in and lets you run the rules, etc., but it can't see the openLuup devices (only relevant if there are other plugins/devices on openLuup that you need access to from MSR); (2) you configure MSR to talk to openLuup, in which case you have all of your Vera and openLuup devices available in MSR, but MSR is talking to the Vera devices over a bridge to openLuup that is talking to the Vera devices over the bridge to Vera (bridge to a bridge, not very efficient); (3) you connect MSR to both, in which case you have all the devices from both like #2, with the option of talking to the Vera devices more directly, but confusion may set in because all of the Vera devices will appear as both the native Vera entities and bridged openLuup entities -- every Vera device is listed in MSR once for its appearance on Vera and again for its appearance in openLuup.

                The biggest con to staying on the Reactor plugin (for Vera/openLuup) is that I have no further development planned for it. As new features go into MSR, I have no plans to "back port" them into R4V. As Vera is "walking dead", so is every Vera plugin, including R4V.

                CatmanV2C Offline
                CatmanV2C Offline
                CatmanV2
                wrote on last edited by
                #7

                @toggledbits said in MSR if you have only one system:

                If you are using openLuup as a single system, that resolves many of the performance issues of the Vera itself (it makes an acceptable radio for the devices it can support, as we all know). There are pros and cons to moving to MSR in this kind of scenario.

                You are bridged, meaning there is a socket-based tunnel between the Vera and openLuup to get the Vera devices into openLuup. If you introduce MSR into the equation, then there are three possibilities: (1) you configure MSR to talk to the Vera directly, in which case MSR brings the Vera devices in and lets you run the rules, etc., but it can't see the openLuup devices (only relevant if there are other plugins/devices on openLuup that you need access to from MSR); (2) you configure MSR to talk to openLuup, in which case you have all of your Vera and openLuup devices available in MSR, but MSR is talking to the Vera devices over a bridge to openLuup that is talking to the Vera devices over the bridge to Vera (bridge to a bridge, not very efficient); (3) you connect MSR to both, in which case you have all the devices from both like #2, with the option of talking to the Vera devices more directly, but confusion may set in because all of the Vera devices will appear as both the native Vera entities and bridged openLuup entities -- every Vera device is listed in MSR once for its appearance on Vera and again for its appearance in openLuup.

                The biggest con to staying on the Reactor plugin (for Vera/openLuup) is that I have no further development planned for it. As new features go into MSR, I have no plans to "back port" them into R4V. As Vera is "walking dead", so is every Vera plugin, including R4V.

                Thanks. That last paragraph is the only one that seems to apply, unless for 'Vera', I read Z-Way-Server?

                The last paragraph is compelling. I assume there's not conflict runnin MSR and Reactor together?

                C

                The Ex-Vera abuser know as CatmanV2.....

                toggledbitsT 1 Reply Last reply
                0
                • CatmanV2C CatmanV2

                  @toggledbits said in MSR if you have only one system:

                  If you are using openLuup as a single system, that resolves many of the performance issues of the Vera itself (it makes an acceptable radio for the devices it can support, as we all know). There are pros and cons to moving to MSR in this kind of scenario.

                  You are bridged, meaning there is a socket-based tunnel between the Vera and openLuup to get the Vera devices into openLuup. If you introduce MSR into the equation, then there are three possibilities: (1) you configure MSR to talk to the Vera directly, in which case MSR brings the Vera devices in and lets you run the rules, etc., but it can't see the openLuup devices (only relevant if there are other plugins/devices on openLuup that you need access to from MSR); (2) you configure MSR to talk to openLuup, in which case you have all of your Vera and openLuup devices available in MSR, but MSR is talking to the Vera devices over a bridge to openLuup that is talking to the Vera devices over the bridge to Vera (bridge to a bridge, not very efficient); (3) you connect MSR to both, in which case you have all the devices from both like #2, with the option of talking to the Vera devices more directly, but confusion may set in because all of the Vera devices will appear as both the native Vera entities and bridged openLuup entities -- every Vera device is listed in MSR once for its appearance on Vera and again for its appearance in openLuup.

                  The biggest con to staying on the Reactor plugin (for Vera/openLuup) is that I have no further development planned for it. As new features go into MSR, I have no plans to "back port" them into R4V. As Vera is "walking dead", so is every Vera plugin, including R4V.

                  Thanks. That last paragraph is the only one that seems to apply, unless for 'Vera', I read Z-Way-Server?

                  The last paragraph is compelling. I assume there's not conflict runnin MSR and Reactor together?

                  C

                  toggledbitsT Offline
                  toggledbitsT Offline
                  toggledbits
                  wrote on last edited by
                  #8

                  @catmanv2 said in MSR if you have only one system:

                  unless for 'Vera', I read Z-Way-Server?

                  Not sure what you mean here.

                  There is no problem running the Reactor for Vera plugin on a Vera or openLuup and running MSR in parallel with it.

                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                  CatmanV2C 1 Reply Last reply
                  0
                  • toggledbitsT toggledbits

                    @catmanv2 said in MSR if you have only one system:

                    unless for 'Vera', I read Z-Way-Server?

                    Not sure what you mean here.

                    There is no problem running the Reactor for Vera plugin on a Vera or openLuup and running MSR in parallel with it.

                    CatmanV2C Offline
                    CatmanV2C Offline
                    CatmanV2
                    wrote on last edited by
                    #9

                    @toggledbits

                    Typed earlier:

                    'You are bridged, meaning there is a socket-based tunnel between the Vera and openLuup to get the Vera devices into openLuup.'

                    Should I read z-way-server for Vera as I don't have a Vera any more?

                    C

                    The Ex-Vera abuser know as CatmanV2.....

                    1 Reply Last reply
                    0
                    • toggledbitsT Offline
                      toggledbitsT Offline
                      toggledbits
                      wrote on last edited by toggledbits
                      #10

                      I don't know how the openLuup ZWay integration works, I don't use it, but if it communicates via a socket with openLuup, then yes, tunnel-to-tunnel. At least its within the same system, though.

                      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                      therealdbT 1 Reply Last reply
                      1
                      • toggledbitsT toggledbits

                        I don't know how the openLuup ZWay integration works, I don't use it, but if it communicates via a socket with openLuup, then yes, tunnel-to-tunnel. At least its within the same system, though.

                        therealdbT Offline
                        therealdbT Offline
                        therealdb
                        wrote on last edited by
                        #11

                        @toggledbits said in MSR if you have only one system:

                        I don't know how the openLuup ZWay integration works

                        It's using polling via HTTP.

                        --
                        On a mission to automate everything.

                        My MS Reactor contrib
                        My Luup Plug-ins

                        1 Reply Last reply
                        0
                        • toggledbitsT toggledbits locked this topic on
                        Reply
                        • Reply as topic
                        Log in to reply
                        • Oldest to Newest
                        • Newest to Oldest
                        • Most Votes


                        Recent Topics

                        • [Solved] DynamicGroupController updating members issue
                          CrilleC
                          Crille
                          0
                          5
                          28

                        • Reactor (Multi-System/Multi-Hub) Announcements
                          toggledbitsT
                          toggledbits
                          5
                          148
                          128.6k

                        • DynamicGroupController and attributes
                          therealdbT
                          therealdb
                          1
                          5
                          78

                        • Arming Envisalink panel from MSR
                          toggledbitsT
                          toggledbits
                          0
                          5
                          97

                        • Upgrade Issues
                          T
                          tbully
                          0
                          9
                          213

                        • [SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
                          toggledbitsT
                          toggledbits
                          0
                          10
                          224

                        • [SOLVED] Question regarding "in" vs "contains" vs contents of the string
                          G
                          gwp1
                          0
                          5
                          111

                        • openLuup console disappeared - 500 - Internal Server Error
                          A
                          a-lurker
                          0
                          2
                          163

                        • Logon screen timeout
                          G
                          gwp1
                          0
                          5
                          190

                        • [MSR] Copy&past of actions and/or drag&drop between set/reset
                          toggledbitsT
                          toggledbits
                          0
                          9
                          340

                        • Upgrade advice - upgrade from aarch64 to ARM64 image
                          toggledbitsT
                          toggledbits
                          0
                          4
                          200
                        Powered by NodeBB | Contributors
                        Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                        • Login

                        • Don't have an account? Register

                        • Login or register to search.
                        • First post
                          Last post
                        0
                        • Categories
                        • Recent
                        • Tags
                        • Popular
                        • Unsolved