Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. [SOLVED] Will Pulse work for retrying a ruleset if the device hasn't responded as expected
UI not loading after upgrading to 26318
tunnusT
Sorry for a hasty post, will update some details later, but the scenario is that I managed to type a wrong password for too many times and had the following users.yaml section: authtrack: max_attempts: 4 within_minutes: 180 # 180 minutes = 3 hrs block_expiration_minutes: 10080 # 7 days At this time I used build 26298. Then noticed there's a new build with a bypass blocking feature (and yes, it said it won't remove existing block). Anyway, went ahead and upgraded to 26318, but the problem now is that UI is not loading at all (page does not answer). This also means that I cannot use "http://reactor_host:port/diag/clear_authtrack?askauth" command to clear the block (or use any other source IP for login). Docker container stays up & running and does not exit. I'll try to dig up some logs, but anything that I could immediately try out (could I delete a particular file for example)? EDIT: some logs [latest-26318]2026-11-17T20:42:32.337Z <Rule:INFO> MSR startup (rule-lculfnhm in Miscellaneous) started [latest-26318]2026-11-17T20:42:32.343Z <httpapi:NOTICE> httpapi#1 HTTP server listening on :::8111 [latest-26318]2026-11-17T20:42:32.347Z <httpapi:INFO> httpapi#1 local docs found in /opt/reactor/docs/html; setting up static service [latest-26318]2026-11-17T20:42:32.354Z <app:NOTICE> Starting WSAPI... [latest-26318]2026-11-17T20:42:32.355Z <wsapi:NOTICE> wsapi: starting version 26298 protocol [latest-26318]2026-11-17T20:42:32.523Z <Engine:INFO> Engine#1 master timer tick, local time "17/11/2026 22:42:32" (TZ offset 120 mins from UTC) [latest-26318]2026-11-17T20:42:32.542Z <Engine:NOTICE> Starting reaction MSR startup<SET> (rule-lculfnhm:S) [latest-26318]2026-11-17T20:42:32.545Z <Notifier:null> Module Notifier v26186 [latest-26318]2026-11-17T20:42:32.545Z <Engine:INFO> MSR startup<SET> all actions completed. [latest-26318]2026-11-17T20:42:32.557Z <Rule:INFO> Rule#rule-lculfnhm reaction rule-lculfnhm:S completed [latest-26318]2026-11-17T20:42:32.558Z <default:null> Module NotifyTelegram v26177
Multi-System Reactor
[Resolved] Hubitat upgrade 2.5.3.123 may have broken login
3
Topic thumbnail image
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Reactor Inspect - a small read-only helper panel for MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Reverse proxy & API ACL
tunnusT
I'm trying to allow anonymous access from a local network to /api/v1/log, but the problem now with the reverse proxy configuration is that this access is open via proxy to the internet. At least I wasn't able to configure ACL so that only an access from a local network would be permitted. reactor.yaml: baseurl: "http://192.168.1.12:8111" proxy_baseurl: "https://external.com:30000" trusted_proxy: "192.168.1.12" Local traffic would originate from 192.168.1.0/24 network. Synology is acting as a reverse proxy and hosting MSR as a docker container (which has its own network and IP 172.18.0.5). MSR build is latest-26298-fbb75fb8 users.yaml: - url: "/api/v1/log" method: "GET" source_ip: 172.18.0.0/24 allow: true Using the above ACL works, but it enables access via proxy also. If I use source_ip: 192.168.1.0/24, then it doesn't work either locally or remotely. So I'm kinda lost what should I use as source_ip in this case?
Multi-System Reactor
MFA
T
Topic thumbnail image
Multi-System Reactor
Grouped devices
G
I've seen many of you using Dynamic Group Controller. I'm using it myself for monitoring device battery levels. I've read and re-read the Dynamic Group Controller docs and still cannot come to an answer for my question so let me paint my scenario: I've migrated from EchoSpeaks in Hubitat ('cause borked and seemingly unmaintained) to Alexa Devices in Home Assistant ('cause not borked in 2026.11.0) to be able to send TTS to my Echo devices. In EchoSpeaks I could create groups. Sweet. In Alexa Devices I don't seem to be able to do so. As such, my thought was "wait - isn't there a way in MSR?" Is this an effective scenario that Dynamic Group Controller can be used for?
Multi-System Reactor
Login protections
tunnusT
Topic thumbnail image
Multi-System Reactor
Reactor Build 26284 stuck at Loading Reactor UI
T
Topic thumbnail image
Multi-System Reactor
MSR with reverse proxy
tunnusT
I'm trying to use MSR via reserve proxy in Synology DSM, but MSR page does not load https://<public ip>:30000/reactor/en-US/ At the same time logging page loads normally https://<public ip>:30000/api/v1/log I thought maybe authentication was messing it up, but there was no deny entries in the log, and also disabling authentication did not make any difference. For this use case VPN is not an option (that works, but as said not an option for this particular use case). Any ideas what could cause this? MSR build latest-26242-28d69aa8, Chrome browser
Multi-System Reactor
Missing attribute after upgrade
3
Topic thumbnail image
Multi-System Reactor
[MSR] Native fan capabilty
therealdbT
Nothing more to add. I see we have hvac_blower, but, anyway, maybe a native fan on the same assumptions of the fan from HASS could be reasonable. I have a couple of them. ie, this is from ESPHome via HASS. x_hass.domain="fan" x_hass.entity_id="fan.kitchen_seashell_hood_ventilation_fan" x_hass.floor_id=null x_hass.services=["fan","esphome"] x_hass.source="esphome" x_hass.state="off" x_hass_attr.friendly_name="Seashell Hood Ventilation Fan" x_hass_attr.percentage=50 x_hass_attr.percentage_step=25 x_hass_attr.preset_mode="" x_hass_attr.preset_modes=[] x_hass_attr.supported_features=49 Thanks.
Multi-System Reactor
[MSR] Rule do not fire
therealdbT
Topic thumbnail image
Multi-System Reactor
Rule condition shows TRUE in UI but Rule never transitions to SET — survives full restart
N
Build: latest-26221-b25bb3e3, Docker on Synology. Hi, I have a Rule whose Trigger/Constraints reference other Rules via Rule State ... is TRUE. At some point it stops firing. Expanding the rule's condition tree in the UI shows every Trigger and Constraint condition green/TRUE — confirmed live by walking into the room and watching Motion go true in real time. Rule History shows no new SET, just old reset entries. Tried, on the same rule, same evening: recreating the trigger conditions with fresh IDs, recreating the constraint conditions with fresh IDs (flat and wrapped in a new Group — wrapping in a Group produced one SET, but it didn't reproduce on repeat attempts with the same structure), and finally a full container restart with a verified-correct saved rule. Still no SET, even with a fresh live motion event right after the restart. Separately, I found that this rule (and its 10 per-room clones) share identical internal condition/group IDs with each other — leftover from a batch clone done months ago, never regenerated. Not sure if that's related, since fixing the IDs didn't reliably fix the symptom either. Has anyone seen a Rule State condition show TRUE in the UI without the Rule ever producing a SET, surviving a clean restart? Thanks in advance
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Unofficial thread for compatibility
tunnusT
As there are statements about compatibility for home assistant versions in MSR new version announcements (e.g. "HassController: Bless Hass to 2025.7.3"), I thought it would be good idea to track other controllers as well. As an example, I can confirm that build "latest-25208-c53e8513" works with Hubitat Elevation C-8 platform version 2.4.2.134 using Maker API. Updates: (the latest versions first in the list) OK: build "latest-25264-2fbe9217" with Hubitat C-8 platform v. 2.4.3.123
Multi-System Reactor
Ooops - Deleted Reactor Ex Machina II
R
I accidentally deleted Reactor Ex Machina II (REM II) from my Reactor rules. I tried to recover it by deleting the .json and .dval in the Rules subdirectory and then recreating it from Togglebits original posting, but that did not work. Does anyone know how to recover REM ll ?
Multi-System Reactor
Bail out of failed reaction?
T
Topic thumbnail image
Multi-System Reactor
Arming Envisalink panel from MSR
T
Topic thumbnail image
Multi-System Reactor
[Solved] DynamicGroupController updating members issue
CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor

[SOLVED] Will Pulse work for retrying a ruleset if the device hasn't responded as expected

Scheduled Pinned Locked Moved Multi-System Reactor
26 Posts 2 Posters 8.8k Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • toggledbitsT toggledbits

    @gwp1 said in Will Pulse work for retrying a ruleset if the device hasn't responded as expected:

    I guess first thing, am I correct in that the pulse running on the rulesets is wasting system resources if those rulesets aren't "eligible" for running?

    No. That's not the case. Unless the underlying condition is true, no pulse train is running. Nothing is happening. I come from the days of room-filling million-dollar computers with 256K (yes, K) of RAM. I don't like wasted cycles. 🙂

    What is true is that whatever the state of the current pulse may be when it is active is not changed by you editing the rules/condition options at the same time. It is not until the current pulse expires that your new pulse rules will take effect. So if you have a condition that is active right now in the middle of a 120 second pulse, and you edit the timing down to 15 seconds, that 120 second pulse is going to finish; it will not be cut short, it will not stop. When it finishes, the next pulse after will be on your new timing. Likewise, if it's timing a break and the underlying condition is still true, the break timing will finish.

    This is why I say, you have to reset the rule after editing it. Your earlier screen shot clearly shows a condition where you edited in the middle of a 120 second pulse break, going from 0 repeats back to 3, and the 120 second pulse break timer is still running. The rule reset function is provided for exactly this circumstance -- to dump existing states and timers. If you don't do the reset, you're going to see really confusing results as Reactor finishes what it was doing before it starts to follow your new instructions.

    And if the pulse is "running all the time" then there is a true state on your logic to make it do that. It does not run otherwise.

    G Offline
    G Offline
    gwp1
    wrote on last edited by
    #10

    @toggledbits The first sentence I can totally wrap my head around 🙂

    The last sentence is what's driving this. If you look at the correction ruleset you'll see it's kinda backward from normal in that the trigger is when something is NOT a certain temp or HVAC mode. This results in it always being in a true state as other rulesets are in effect.

    Different words:
    When Heating or Cooling rulesets are controlling things, Neutral correction shows true - because it is. This results in pulse always running (or, if metered, running out of retries.)

    *Hubitat C-7 2.5.2.139
    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

    *HAOS
    Core 2026.10.4
    w/ HA Connect ZWA-2 & ZBT-2
    FW: v1.1
    SDK: v7.23.1

    *Prod MSR in docker/portainer
    MSR: latest-26298-fbb75fb8
    MQTTController: 25139
    ZWave Controller: 25139

    1 Reply Last reply
    0
    • toggledbitsT Online
      toggledbitsT Online
      toggledbits
      wrote on last edited by
      #11

      I see what you're getting at. That's simply a problem with your condition structure. The inner groups can't know how any enclosing groups are going to interpret their output, so of course the pulses run, as well they should -- you've told them to. If that's not what you want, a slight restructure of your logic fixes that.

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      G 2 Replies Last reply
      0
      • toggledbitsT toggledbits

        I see what you're getting at. That's simply a problem with your condition structure. The inner groups can't know how any enclosing groups are going to interpret their output, so of course the pulses run, as well they should -- you've told them to. If that's not what you want, a slight restructure of your logic fixes that.

        G Offline
        G Offline
        gwp1
        wrote on last edited by
        #12

        @toggledbits Def not what I want but it's the direct path. "If after running Neutral the conditions don't match, run the correction."

        *Hubitat C-7 2.5.2.139
        *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

        *HAOS
        Core 2026.10.4
        w/ HA Connect ZWA-2 & ZBT-2
        FW: v1.1
        SDK: v7.23.1

        *Prod MSR in docker/portainer
        MSR: latest-26298-fbb75fb8
        MQTTController: 25139
        ZWave Controller: 25139

        1 Reply Last reply
        0
        • toggledbitsT Online
          toggledbitsT Online
          toggledbits
          wrote on last edited by toggledbits
          #13

          @gwp1 said in Will Pulse work for retrying a ruleset if the device hasn't responded as expected:

          Def not what I want but it's the direct path. "If after running Neutral the conditions don't match, run the correction."

          I'm not sure what that means.

          I think all you need to do is create an enclosing group, put all of the conditions/subgroups, including the Rule State condition, into it, and then move the pulse configuration to that upper enclosing group, removing it from the interior groups. The Rule State condition will then gate the pulse train.

          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

          1 Reply Last reply
          0
          • toggledbitsT toggledbits

            I see what you're getting at. That's simply a problem with your condition structure. The inner groups can't know how any enclosing groups are going to interpret their output, so of course the pulses run, as well they should -- you've told them to. If that's not what you want, a slight restructure of your logic fixes that.

            G Offline
            G Offline
            gwp1
            wrote on last edited by
            #14

            @toggledbits So this took a major rewrite, esp for the Neutral because you could be going from Heat to Neutral, from Cooling to Neutral, and back again. The goal here, now, is to have it so that something must go true and there are far more options to cover than triggering on something going false. This is what I've arrived at - a second+ set of eyes on my work would be appreciated.

            new.png

            new2.png

            I stared at it 'til I'm cross-eyed!

            *Hubitat C-7 2.5.2.139
            *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

            *HAOS
            Core 2026.10.4
            w/ HA Connect ZWA-2 & ZBT-2
            FW: v1.1
            SDK: v7.23.1

            *Prod MSR in docker/portainer
            MSR: latest-26298-fbb75fb8
            MQTTController: 25139
            ZWave Controller: 25139

            1 Reply Last reply
            0
            • toggledbitsT Online
              toggledbitsT Online
              toggledbits
              wrote on last edited by
              #15

              I'm thinking still not right. The group with the pulse output needs to be a wrapper group for EVERYTHING else, including the Rule State condition, to my way of looking at it.

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              G 1 Reply Last reply
              0
              • toggledbitsT toggledbits

                I'm thinking still not right. The group with the pulse output needs to be a wrapper group for EVERYTHING else, including the Rule State condition, to my way of looking at it.

                G Offline
                G Offline
                gwp1
                wrote on last edited by
                #16

                @toggledbits Like this:

                new3.png

                What's the reasoning behind bumping that up one more level?

                *Hubitat C-7 2.5.2.139
                *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                *HAOS
                Core 2026.10.4
                w/ HA Connect ZWA-2 & ZBT-2
                FW: v1.1
                SDK: v7.23.1

                *Prod MSR in docker/portainer
                MSR: latest-26298-fbb75fb8
                MQTTController: 25139
                ZWave Controller: 25139

                1 Reply Last reply
                0
                • toggledbitsT Online
                  toggledbitsT Online
                  toggledbits
                  wrote on last edited by
                  #17

                  Yes, I think this is closer to what you really want. This keeps the pulses from firing unless the Rule State condition is also true, so that you can (again) use the limited count of pulses, because pulses won't be firing unless all of the conditions AND the rule state are all true. That is, pulses will only happen when the devices aren't set properly for "Neutral" (for a while) and Neutral is the active mode.

                  You also have to think about your "sustained for" timing. That is also done in the interior, meaning it is done irrespective of whether the Neutral mode is active or not, and that, too, is probably not what you want. The effect is that your correction will fire immediately if the Neutral conditions haven't been met for a while at the time the system is switched into Neutral mode. I imagine you actually want a delay there, since it probably takes a couple of seconds for the transition into Neutral mode to make the round trip through the cloud and devices and be reported back. You need to give it a chance to work/catch up. A simple fix there is to simply add a sustained for delay to the Rule State (is Neutral active) condition, so your logic overall becomes "if the mode has been Neutral for at least 300 seconds and the devices haven't been set properly for at least 300 seconds".

                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                  G 1 Reply Last reply
                  0
                  • toggledbitsT toggledbits

                    Yes, I think this is closer to what you really want. This keeps the pulses from firing unless the Rule State condition is also true, so that you can (again) use the limited count of pulses, because pulses won't be firing unless all of the conditions AND the rule state are all true. That is, pulses will only happen when the devices aren't set properly for "Neutral" (for a while) and Neutral is the active mode.

                    You also have to think about your "sustained for" timing. That is also done in the interior, meaning it is done irrespective of whether the Neutral mode is active or not, and that, too, is probably not what you want. The effect is that your correction will fire immediately if the Neutral conditions haven't been met for a while at the time the system is switched into Neutral mode. I imagine you actually want a delay there, since it probably takes a couple of seconds for the transition into Neutral mode to make the round trip through the cloud and devices and be reported back. You need to give it a chance to work/catch up. A simple fix there is to simply add a sustained for delay to the Rule State (is Neutral active) condition, so your logic overall becomes "if the mode has been Neutral for at least 300 seconds and the devices haven't been set properly for at least 300 seconds".

                    G Offline
                    G Offline
                    gwp1
                    wrote on last edited by
                    #18

                    @toggledbits HA, funny you bring that last part up because the sun has gone down so the system races thru Neutral to Heating as the temps drop quickly. I did notice the 300 seconds was being ignored, seemingly, and the correction fired on the heels of the change.

                    I did move the 300 seconds up to the next group level. Since UP and Down both are sub-groups within the larger group I thought it made sense to raise that a level - do correct me if I'm wrong here.

                    Looking into the tweak you noted in your response.

                    *Hubitat C-7 2.5.2.139
                    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                    *HAOS
                    Core 2026.10.4
                    w/ HA Connect ZWA-2 & ZBT-2
                    FW: v1.1
                    SDK: v7.23.1

                    *Prod MSR in docker/portainer
                    MSR: latest-26298-fbb75fb8
                    MQTTController: 25139
                    ZWave Controller: 25139

                    toggledbitsT 1 Reply Last reply
                    0
                    • G gwp1

                      @toggledbits HA, funny you bring that last part up because the sun has gone down so the system races thru Neutral to Heating as the temps drop quickly. I did notice the 300 seconds was being ignored, seemingly, and the correction fired on the heels of the change.

                      I did move the 300 seconds up to the next group level. Since UP and Down both are sub-groups within the larger group I thought it made sense to raise that a level - do correct me if I'm wrong here.

                      Looking into the tweak you noted in your response.

                      toggledbitsT Online
                      toggledbitsT Online
                      toggledbits
                      wrote on last edited by
                      #19

                      @gwp1 said in Will Pulse work for retrying a ruleset if the device hasn't responded as expected:

                      I thought it made sense to raise that a level - do correct me if I'm wrong here.

                      This is a good rule of thumb. Well done!

                      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                      G 1 Reply Last reply
                      1
                      • toggledbitsT toggledbits

                        @gwp1 said in Will Pulse work for retrying a ruleset if the device hasn't responded as expected:

                        I thought it made sense to raise that a level - do correct me if I'm wrong here.

                        This is a good rule of thumb. Well done!

                        G Offline
                        G Offline
                        gwp1
                        wrote on last edited by
                        #20

                        @toggledbits QQ, all of these 300 second sustains... they're working concurrently, not consecutively, yes?

                        *Hubitat C-7 2.5.2.139
                        *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                        *HAOS
                        Core 2026.10.4
                        w/ HA Connect ZWA-2 & ZBT-2
                        FW: v1.1
                        SDK: v7.23.1

                        *Prod MSR in docker/portainer
                        MSR: latest-26298-fbb75fb8
                        MQTTController: 25139
                        ZWave Controller: 25139

                        1 Reply Last reply
                        0
                        • toggledbitsT Online
                          toggledbitsT Online
                          toggledbits
                          wrote on last edited by
                          #21

                          They can -- it depends on when their respective conditions get them rolling...

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          G 1 Reply Last reply
                          0
                          • toggledbitsT toggledbits

                            They can -- it depends on when their respective conditions get them rolling...

                            G Offline
                            G Offline
                            gwp1
                            wrote on last edited by gwp1
                            #22

                            @toggledbits Before heading off to sleep the house slips into "night" mode. One stat, the upstairs one, did not change to night temp so I came in to watch the correction happen.

                            It didn't. No sustained for timers rolling, nothing.

                            I moved the Sustained for 300s back down to the next group level, that of the Up and Down t-stat level and the sustained for timer showed up. #win

                            When I hit reset the rule state for Arm for Heating started its sustained for timer as expected. So did the timer for down which makes sense because it is the stat that didn't come along.

                            And then when the 300 seconds ran out... nothing. Nothing happened. Even the highest level pulse didn't... pulse.

                            Screen Shot 2021-12-14 at 10.48.11 PM.png

                            Up is still wrong and nothing looks like it's running to correct it. I'm wondering if moving the pulse to the top-most level isn't working. I can't see why not - but I don't know why the sustained for timers didn't go at one level higher, either.

                            Update: those moves didn't help, when the timers ran out the AND Upstairs for at least 300 secs [or] bar blinked and... no reaction ran.

                            *Hubitat C-7 2.5.2.139
                            *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                            *HAOS
                            Core 2026.10.4
                            w/ HA Connect ZWA-2 & ZBT-2
                            FW: v1.1
                            SDK: v7.23.1

                            *Prod MSR in docker/portainer
                            MSR: latest-26298-fbb75fb8
                            MQTTController: 25139
                            ZWave Controller: 25139

                            1 Reply Last reply
                            0
                            • toggledbitsT Online
                              toggledbitsT Online
                              toggledbits
                              wrote on last edited by
                              #23

                              Stats is in AND mode, so both Upstairs and Downstairs need to be true at the same time. Is that intended?

                              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                              G 1 Reply Last reply
                              0
                              • toggledbitsT toggledbits

                                Stats is in AND mode, so both Upstairs and Downstairs need to be true at the same time. Is that intended?

                                G Offline
                                G Offline
                                gwp1
                                wrote on last edited by gwp1
                                #24

                                @toggledbits Wow, great catch. There's also another error in this one where statmode and setpoints should be AND, not OR. I think this got bolluxed when I started moving groups into groups into groups.

                                Quick review of the other rulesets and I see a couple more of these here and there including one that I was trying to test/troubleshoot just this morning.

                                Nice catch - appreciate it! Now I'll validate these work again and then, one by one, make the pulse and sustained for edits back up to higher levels.

                                *Hubitat C-7 2.5.2.139
                                *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                                *HAOS
                                Core 2026.10.4
                                w/ HA Connect ZWA-2 & ZBT-2
                                FW: v1.1
                                SDK: v7.23.1

                                *Prod MSR in docker/portainer
                                MSR: latest-26298-fbb75fb8
                                MQTTController: 25139
                                ZWave Controller: 25139

                                1 Reply Last reply
                                0
                                • toggledbitsT Online
                                  toggledbitsT Online
                                  toggledbits
                                  wrote on last edited by toggledbits
                                  #25

                                  Remember to give those status lines a good hard squiz. I still don't understand your logic completely, but when you said you expected pulses to be rolling, and the top interior group was not true while an interior group was true (and that was correct/expected, as you also pointed out), that was the clue to make me ask about the operation on the group. Follow your groups up from where they are as expected to where they are not, and check those operators! 🙂

                                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                  G 1 Reply Last reply
                                  0
                                  • toggledbitsT toggledbits

                                    Remember to give those status lines a good hard squiz. I still don't understand your logic completely, but when you said you expected pulses to be rolling, and the top interior group was not true while an interior group was true (and that was correct/expected, as you also pointed out), that was the clue to make me ask about the operation on the group. Follow your groups up from where they are as expected to where they are not, and check those operators! 🙂

                                    G Offline
                                    G Offline
                                    gwp1
                                    wrote on last edited by
                                    #26

                                    @toggledbits I'm marking this as solved because I watched a couple of the rulesets WIA this morning as the day's temps ramped up.

                                    Thanks for your incite and guidance as always, sir!

                                    *Hubitat C-7 2.5.2.139
                                    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                                    *HAOS
                                    Core 2026.10.4
                                    w/ HA Connect ZWA-2 & ZBT-2
                                    FW: v1.1
                                    SDK: v7.23.1

                                    *Prod MSR in docker/portainer
                                    MSR: latest-26298-fbb75fb8
                                    MQTTController: 25139
                                    ZWave Controller: 25139

                                    1 Reply Last reply
                                    2
                                    • G gwp1 referenced this topic on
                                    Reply
                                    • Reply as topic
                                    Log in to reply
                                    • Oldest to Newest
                                    • Newest to Oldest
                                    • Most Votes


                                    Recent Topics

                                    • UI not loading after upgrading to 26318
                                      toggledbitsT
                                      toggledbits
                                      0
                                      6
                                      209

                                    • [Resolved] Hubitat upgrade 2.5.3.123 may have broken login
                                      toggledbitsT
                                      toggledbits
                                      0
                                      8
                                      338

                                    • Reactor (Multi-System/Multi-Hub) Announcements
                                      toggledbitsT
                                      toggledbits
                                      5
                                      153
                                      164.2k

                                    • Reactor Inspect - a small read-only helper panel for MSR
                                      G
                                      gwp1
                                      2
                                      8
                                      651

                                    • Reverse proxy & API ACL
                                      tunnusT
                                      tunnus
                                      0
                                      9
                                      577

                                    • MFA
                                      T
                                      tamorgen
                                      0
                                      28
                                      1.5k

                                    • Grouped devices
                                      G
                                      gwp1
                                      0
                                      3
                                      219

                                    • Login protections
                                      toggledbitsT
                                      toggledbits
                                      0
                                      2
                                      256

                                    • Reactor Build 26284 stuck at Loading Reactor UI
                                      T
                                      tamorgen
                                      0
                                      16
                                      1.8k

                                    • MSR with reverse proxy
                                      tunnusT
                                      tunnus
                                      0
                                      12
                                      931

                                    • Missing attribute after upgrade
                                      3
                                      3rdStng
                                      0
                                      3
                                      714

                                    • Use of Google Gemini as an MSR and Hubitat configuration aid
                                      therealdbT
                                      therealdb
                                      0
                                      2
                                      357
                                    Powered by NodeBB | Contributors
                                    Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                    • Login

                                    • Don't have an account? Register

                                    • Login or register to search.
                                    • First post
                                      Last post
                                    0
                                    • Categories
                                    • Recent
                                    • Tags
                                    • Popular
                                    • Unsolved