R
I have tried numerous ways to define a recurring annual period, for example from December 15 to January 15. No matter which method I try - after and before, between, after and/not after, Reactor reports "waiting for invalid date, invalid date. Some constructs also seem to cause Reactor to hang, timeout and restart. For example "before January 15 is evaluated as true, but reports "waiting for invalid date, invalid date". Does anyone have a tried and true method to define a recurring annual period? I think the "between" that I used successfully in the past may have broken with one of the updates.
Multi-System Reactor
Need help with sequence
T
Good evening all, For about the past week or so, I've been having problems with a specific rule in my home automation that controls when my home goes from an Away mode to Home mode. One of the conditions it checked for was my alarm panel, when it changed from Armed Away to Disarmed. There seems to have been a firmware update on the panel that added an intermittent step of "pending", and I can't say for certain it happens 100% of the time. Is there a way to write a condition that so it changes from one condition, to the next, and then another condition? As in, Home alarm changes from armed_away to pending to disarmed. Thanks.
Multi-System Reactor
Possible feature request?
CatmanV2C
No idea how easy this would be. During my migration away from Z-wave I've been replacing the Z-wave devices with Sonoff which has broken some of my automations. Any chance of a 'Test Reaction' function to call out which ones are broken because an entity no longer exists? Without actually running the reaction? Or does this exist already and I'm just not aware of how to do it? Obviously I can see entities that are no longer available, but not quite what I'm looking for. I guess it's something of an edge case so no huge issue. TIA! C
Multi-System Reactor
Copying a global reaction
tunnusT
With build 25328, if you copy a global reaction, a new reaction does not appear in the UI unless you do a refresh. I recall this used to work without needing this page refresh? Anyway, only a minor nuisance.
Multi-System Reactor
Logic Assistance: Exterior Lights on when Illuminance Below Threshold
PablaP
Topic thumbnail image
Multi-System Reactor
Time series documentation
tunnusT
Is the current manual (incl. examples) up to date with how retention value is handled in time series configuration? Referring to this post
Multi-System Reactor
MQTT templates for ZIgbee scene controller, or a better way?
CatmanV2C
Topic thumbnail image
Multi-System Reactor
Reset a delay
CatmanV2C
I'm sure this has been asked, and answered, but damned if I can figure it out Use case: I have a rear garden with lights. A door from the kitchen into the garden and a door from the garage. Currently if I open the kitchen door the lights come on (yay) and a 3 minute delay starts. After 3 minutes, no matter what else happens, the lights go off (Boo! But also yay!) What I would like is for the 3 minute delay until the lights go off to start from the latest door open event. That is, if I'm going from kitchen to garage, and back again, the lights stay on until there's three minutes of no activity. I've tried 'hacking' with a virtual switch, but can't seem to stop the delay. Any pointers? TIA C
Multi-System Reactor
Reactor Loading Screen Safari
S
Topic thumbnail image
Multi-System Reactor
Constraints states visually do not match actual
S
Topic thumbnail image
Multi-System Reactor
[MSR] Feature request: For Each action on arrays/groups
therealdbT
Topic thumbnail image
Multi-System Reactor
[Solved] Error: Command timeout
G
at _ClientAPI._commandTimeout (http://192.168.1.100:8111/client/ClientAPI.js:807:179 Seeing this randomly when returning to open browser tab after being away awhile. Once, maybe twice a day. "What did you do to trigger it?" Literally nothing, just walked away and returned and there it was. Actions taken in reasonably close proximity to this particular instance of it popping up: I'd restarted the MSR container in Portainer. I'll try to grab some logs here shortly.
Multi-System Reactor
Issue with MSR UI becoming unresponsive
S
I'm having an issue with MSR's UI being very unresponsive. It started happening a couple days ago and I didn't make any changes that would have caused this except adding some meross lan devices in HA. When I go into an entity action and use the search functionality, it usually will start filtering and then get to a place after a few letters are entered where it will take 30 seconds or more (sometimes minutes) for the UI to show what I am typing. During this time MSR ui is completely unresponsive. I've tried multiple browsers and multiple computers. HA and MSR are both deployed in docker. I have run HTOP on the host and when the problem happens there are no CPU/Memory spikes at all. From a functionality standpoint MSR is working perfectly. This seems to be an UI issue only. Do i need to ditch Docker and run MSR on a Proxmox VM? I have both stand alone Docker and Proxmox environments. I dont mind doing that I just want to be able to use the UI again... Installation method Home Assistant Container Core 2025.7.3 Frontend 20250702.3 nothing crazy in the logs except some openweather map stuff that doesn't make any sense as it is working fine in MSR Any help would be greatly appreciated Reactor latest-25328-b2ed1365 app 25328 configuration from /var/reactor/config NODE_PATH /opt/reactor:/opt/reactor/node_modules [latest-25328]2025-11-30T20:01:53.843Z <app:null> Reactor build latest-25328-b2ed1365 starting on v24.11.1 /usr/local/bin/node [latest-25328]2025-11-30T20:01:53.844Z <app:null> Process ID 1 user/group 0/0; docker; platform linux/x64 #161-Ubuntu SMP Tue Jul 22 14:25:40 UTC 2025; locale (undefined) [latest-25328]2025-11-30T20:01:53.844Z <app:null> Basedir /opt/reactor; data in /var/reactor/storage [latest-25328]2025-11-30T20:01:53.844Z <app:null> NODE_PATH=/opt/reactor:/opt/reactor/node_modules [latest-25328]2025-11-30T20:01:53.865Z <app:null> Resolved timezone=America/New_York, environment TZ=America/New_York; offset minutes from UTC=-300 [latest-25328]2025-11-30T20:01:53.867Z <default:null> Module i18n v25141 [latest-25328]2025-11-30T20:01:53.867Z <app:null> Configured locale (undefined); selected locale(s) en-US.UTF-8 [latest-25328]2025-11-30T20:01:53.879Z <app:null> Loaded locale en-US for en-US [latest-25328]2025-11-30T20:01:53.879Z <app:null> Local date/time using configured timezone and locale formatting is "11/30/2025, 3:01:53 PM" [latest-25328]2025-11-30T20:01:53.889Z <Structure:null> Module Structure v25326 [latest-25328]2025-11-30T20:01:53.890Z <Capabilities:null> Module Capabilities v24312 [latest-25328]2025-11-30T20:01:53.904Z <Plugin:null> Module Plugin v25141 [latest-25328]2025-11-30T20:01:53.923Z <Timer:null> Module Timer v25279 [latest-25328]2025-11-30T20:01:53.924Z <TimerBroker:null> Module TimerBroker v25314 [latest-25328]2025-11-30T20:01:53.927Z <Entity:null> Module Entity v25251 [latest-25328]2025-11-30T20:01:53.929Z <Controller:null> Module Controller v25253 [latest-25328]2025-11-30T20:01:53.930Z <AlertManager:null> Module AlertManager v25318 [latest-25328]2025-11-30T20:01:53.937Z <default:null> Module Ruleset v25283 [latest-25328]2025-11-30T20:01:53.937Z <default:null> Module Rulesets v25141 [latest-25328]2025-11-30T20:01:53.942Z <GlobalExpression:null> Module GlobalExpression v25258 [latest-25328]2025-11-30T20:01:53.953Z <Predicate:null> Module Predicate v25328 [latest-25328]2025-11-30T20:01:53.956Z <Rule:null> Module Rule v25323 [latest-25328]2025-11-30T20:01:53.958Z <GlobalReaction:null> Module GlobalReaction v25292 [latest-25328]2025-11-30T20:01:53.959Z <Engine:null> Module Engine v25325 [latest-25328]2025-11-30T20:01:53.964Z <httpapi:null> Module httpapi v25328 [latest-25328]2025-11-30T20:01:53.972Z <wsapi:null> Module wsapi v25328 [latest-25328]2025-11-30T20:01:53.994Z <TaskQueue:null> Module TaskQueue 24138 [latest-25328]2025-11-30T20:01:53.994Z <VeraController:null> Module VeraController v25141 [latest-25328]2025-11-30T20:01:54.179Z <HassController:null> Module HassController v25325 [latest-25328]2025-11-30T20:02:13.797Z <OWMWeatherController:null> Module OWMWeatherController v25268 [latest-25328]2025-11-30T20:02:13.800Z <SystemController:null> Module SystemController v25323 [latest-25328]2025-11-30T20:02:13.807Z <MQTTController:null> Module MQTTController v22092 [latest-25328]2025-11-30T20:02:20.630Z <OWMWeatherController:CRIT> FetchError: request to https://api.openweathermap.org/data/2.5/weather?lat=xxxxxxxxxx&lon=-xxxxxxxxx&appid=xxxxxxxxxxxxxxxxxxxxxxxxxx&units=standard&_r=1xxxxxxxxxxxxxxfailed, reason: [-] FetchError: request to https://api.openweathermap.org/data/2.5/weather?lat=xxxxxxxxxxx&lon=-xxxxxxxxxxxxxxxxxx&appid=xxxxxxxxxxxxxxxxxxx&units=standard&_r=xxxxxxxxxxxxxxxfailed, reason: at ClientRequest.<anonymous> (/opt/reactor/node_modules/node-fetch/lib/index.js:1501:11) at ClientRequest.emit (node:events:508:28) at ClientRequest.emit (node:domain:489:12) at emitErrorEvent (node:_http_client:108:11) at TLSSocket.socketErrorListener (node:_http_client:575:5) at TLSSocket.emit (node:events:508:28) at TLSSocket.emit (node:domain:489:12) at emitErrorNT (node:internal/streams/destroy:170:8) at emitErrorCloseNT (node:internal/streams/destroy:129:3) at processTicksAndRejections (node:internal/process/task_queues:89:21
Multi-System Reactor
Date/time condition
tunnusT
Topic thumbnail image
Multi-System Reactor
Device log?
G
@toggledbits is there a log that will show me what rule is turning on a specific device? I've got a switch that has been kicking on at 2200 ET for several nights now and the reactor.log doesn't have a thing in it that I can see on a device level (it being more rules-based).
Multi-System Reactor
Midnight crossing not working in date/time condition (build 25325)
tunnusT
Topic thumbnail image
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
[Solved] Local expression in Rule does not evaluate as they used to do
CrilleC
Topic thumbnail image
Multi-System Reactor
Home Assistant 2025.11.2 and latest-25315
CrilleC
Topic thumbnail image
Multi-System Reactor

[SOLVED] New iblind and zwaveJScontroller/MSR not communicating

Scheduled Pinned Locked Moved Multi-System Reactor
solved
44 Posts 3 Posters 12.8k Views 3 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • T tamorgen

    Okay, gotcha. I did verify that the cover.open using the zwavejscontroller entries does work on my system with the updated release. Curious that the cover.open command does not work using the equivalent haas entity.

    G Offline
    G Offline
    gwp1
    wrote on last edited by
    #25

    @tamorgen cover.open and cover.close worked for me intermittently, eventually degrading to not at all. position.set seems to be working pretty well.

    *Hubitat C-7 2.4.3.173
    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

    *HASS 2025.12.4, Core 2025.12.3
    w/ HA Connect ZWA-2
    FW: v1.1
    SDK: v7.23.1

    *Prod MSR in docker/portainer
    MSR: latest-25328-b2ed1365
    MQTTController: 25139
    ZWave Controller: 25139

    G 1 Reply Last reply
    0
    • G gwp1

      @tamorgen cover.open and cover.close worked for me intermittently, eventually degrading to not at all. position.set seems to be working pretty well.

      G Offline
      G Offline
      gwp1
      wrote on last edited by
      #26

      @toggledbits I conducted some tests tonight.

      MSR's ZWaveJSController
      HA ZWaveJSController Plugin via HA

      Sending you an image since I can't upload any here for some reason (parser error) via your file share.

      Results of my tests:
      MSR's ZWJSC: no response
      HA ZWJSC plugin: no response from any command other than x_hass_cover.set_cover_tilt_position

      [latest-23242]2023-09-17T23:34:45.311Z <Rule:INFO> The Internet is up (rule-l2gdh04j in Notifications) evaluation complete
      [latest-23242]2023-09-17T23:34:45.312Z <Rule:INFO> Check Internet Status (rule-l2f9yuad in Reactor Alerts and Checks) evaluation complete
      [latest-23242]2023-09-17T23:34:45.313Z <Rule:INFO> HTTP Failed Alerts (rule-l2kd6w6k in Reactor Alerts and Checks) evaluation complete
      [latest-23242]2023-09-17T23:34:45.313Z <Rule:INFO> MSR Update Notifier (rule-l9vf6nai in Reactor Alerts and Checks) evaluation complete
      [latest-23242]2023-09-17T23:34:45.316Z <Rule:INFO> The Internet is up (rule-l2gdh04j in Notifications) starting evaluation; because entity-changed System#reactor_system>system
      [latest-23242]2023-09-17T23:34:45.317Z <Rule:INFO> Check Internet Status (rule-l2f9yuad in Reactor Alerts and Checks) starting evaluation; because entity-changed System#reactor_system>system
      [latest-23242]2023-09-17T23:34:45.317Z <Rule:INFO> HTTP Failed Alerts (rule-l2kd6w6k in Reactor Alerts and Checks) starting evaluation; because entity-changed System#reactor_system>system
      [latest-23242]2023-09-17T23:34:45.317Z <Rule:INFO> MSR Update Notifier (rule-l9vf6nai in Reactor Alerts and Checks) starting evaluation; because entity-changed System#reactor_system>system
      [latest-23242]2023-09-17T23:34:45.318Z <Rule:INFO> The Internet is up (rule-l2gdh04j in Notifications) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:45.318Z <Rule:INFO> The Internet is up (rule-l2gdh04j in Notifications) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:45.320Z <Rule:INFO> Check Internet Status (rule-l2f9yuad in Reactor Alerts and Checks) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:45.320Z <Rule:INFO> Check Internet Status (rule-l2f9yuad in Reactor Alerts and Checks) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:45.321Z <Rule:INFO> HTTP Failed Alerts (rule-l2kd6w6k in Reactor Alerts and Checks) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:45.321Z <Rule:INFO> HTTP Failed Alerts (rule-l2kd6w6k in Reactor Alerts and Checks) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:45.322Z <Rule:INFO> MSR Update Notifier (rule-l9vf6nai in Reactor Alerts and Checks) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:45.323Z <Rule:INFO> MSR Update Notifier (rule-l9vf6nai in Reactor Alerts and Checks) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:45.323Z <Rule:INFO> The Internet is up (rule-l2gdh04j in Notifications) evaluation complete
      [latest-23242]2023-09-17T23:34:45.323Z <Rule:INFO> Check Internet Status (rule-l2f9yuad in Reactor Alerts and Checks) evaluation complete
      [latest-23242]2023-09-17T23:34:45.324Z <Rule:INFO> HTTP Failed Alerts (rule-l2kd6w6k in Reactor Alerts and Checks) evaluation complete
      [latest-23242]2023-09-17T23:34:45.324Z <Rule:INFO> MSR Update Notifier (rule-l9vf6nai in Reactor Alerts and Checks) evaluation complete
      [latest-23242]2023-09-17T23:34:45.346Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) starting evaluation; because entity-changed ValueSensor#hass>sensor_john_iphone_battery_status
      [latest-23242]2023-09-17T23:34:45.349Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:45.349Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:45.350Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) evaluation complete
      [latest-23242]2023-09-17T23:34:50.341Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) starting evaluation; because entity-changed ValueSensor#hass>sensor_john_iphone_battery_status
      [latest-23242]2023-09-17T23:34:50.347Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:50.348Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:50.349Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) evaluation complete
      [latest-23242]2023-09-17T23:34:51.559Z <HubitatController:INFO> HubitatController#hubitat ignoring DEVICE event for device 1405 (Sun Position); device not enumerated by Maker API
      [latest-23242]2023-09-17T23:34:51.600Z <HubitatController:INFO> HubitatController#hubitat ignoring DEVICE event for device 1405 (Sun Position); device not enumerated by Maker API
      [latest-23242]2023-09-17T23:34:51.662Z <HubitatController:INFO> HubitatController#hubitat ignoring DEVICE event for device 1405 (Sun Position); device not enumerated by Maker API
      [latest-23242]2023-09-17T23:34:55.352Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) starting evaluation; because entity-changed ValueSensor#hass>sensor_john_iphone_battery_status
      [latest-23242]2023-09-17T23:34:55.357Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) trigger evaluation result is false (previously false)
      [latest-23242]2023-09-17T23:34:55.357Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) evaluated; trigger state unchanged (false); rule state remains RESET
      [latest-23242]2023-09-17T23:34:55.359Z <Rule:INFO> Change to Night (via ESPresense) (rule-kwc6rmci in Mode Triggers) evaluation complete
      [latest-23242]2023-09-17T23:34:55.426Z <Engine:INFO> Enqueueing "Blinds DR Open" (re-kx6a2k13)
      **[latest-23242]2023-09-17T23:34:55.429Z <Engine:NOTICE> Starting reaction Blinds DR Open (re-kx6a2k13)**
      [latest-23242]2023-09-17T23:34:56.685Z <ZWaveJSController:5:ZWaveJSController.js:798> ZWaveJSController#zwavejs handling node event statistics updated entity Cover#zwavejs>22-0
      [latest-23242]2023-09-17T23:34:56.767Z <ZWaveJSController:5:ZWaveJSController.js:798> ZWaveJSController#zwavejs handling node event value updated entity Cover#zwavejs>22-0
      [latest-23242]2023-09-17T23:34:56.769Z <ZWaveJSController:5:ZWaveJSController.js:994> ZWaveJSController#zwavejs update node 22 value "0:106:targetValue:23" data [Object]{ "source": "node", "event": "value updated", "nodeId": 22, "args": { "commandClassName": "Window Covering", "commandClass": 106, "endpoint": 0, "property": "targetValue", "propertyKey": 23, "newValue": 50, "prevValue": 0, "propertyName": "targetValue", "propertyKeyName": "Horizontal Slats Angle" } }
      [latest-23242]2023-09-17T23:34:56.770Z <ZWaveJSController:5:ZWaveJSController.js:1006> ZWaveJSController#zwavejs updating attributes for node 22 value "0:106:targetValue:23"=50: [Array][  ]
      [latest-23242]2023-09-17T23:34:56.771Z <ZWaveJSController:5:ZWaveJSController.js:1025> ZWaveJSController#zwavejs setting Cover#zwavejs>22-0.x_zwave_values.Window_Covering_targetValue_23 to 50
      [latest-23242]2023-09-17T23:34:56.782Z <ZWaveJSController:5:ZWaveJSController.js:798> ZWaveJSController#zwavejs handling node event value updated entity Cover#zwavejs>22-0
      [latest-23242]2023-09-17T23:34:56.783Z <ZWaveJSController:5:ZWaveJSController.js:994> ZWaveJSController#zwavejs update node 22 value "0:106:currentValue:23" data [Object]{ "source": "node", "event": "value updated", "nodeId": 22, "args": { "commandClassName": "Window Covering", "commandClass": 106, "property": "currentValue", "propertyKey": 23, "endpoint": 0, "newValue": 50, "prevValue": 0, "propertyName": "currentValue", "propertyKeyName": "Horizontal Slats Angle" } }
      [latest-23242]2023-09-17T23:34:56.785Z <ZWaveJSController:5:ZWaveJSController.js:1006> ZWaveJSController#zwavejs updating attributes for node 22 value "0:106:currentValue:23"=50: [Array][ "cover.state", "position.value" ]
      [latest-23242]2023-09-17T23:34:56.787Z <ZWaveJSController:5:ZWaveJSController.js:1013> ZWaveJSController#zwavejs updating attribute cover.state with [Object]{ "entity": "22-0", "impl": { "expr": "!(value == 0 || value >= 99)", "valueId": "106:currentValue:23" } }
      [latest-23242]2023-09-17T23:34:56.787Z <ZWaveJSController:5:ZWaveJSController.js:947> ZWaveJSController#zwavejs _apply_value entity Cover#zwavejs>22-0 cover.state
      [latest-23242]2023-09-17T23:34:56.788Z <ZWaveJSController:5:ZWaveJSController.js:987> ZWaveJSController#zwavejs _apply_value cover.state=true
      [latest-23242]2023-09-17T23:34:56.789Z <ZWaveJSController:5:ZWaveJSController.js:1013> ZWaveJSController#zwavejs updating attribute position.value with [Object]{ "entity": "22-0", "impl": { "expr": "round( value / 99, 2 )", "valueId": "106:currentValue:23" } }
      [latest-23242]2023-09-17T23:34:56.790Z <ZWaveJSController:5:ZWaveJSController.js:947> ZWaveJSController#zwavejs _apply_value entity Cover#zwavejs>22-0 position.value
      [latest-23242]2023-09-17T23:34:56.791Z <ZWaveJSController:5:ZWaveJSController.js:987> ZWaveJSController#zwavejs _apply_value position.value=0.51
      [latest-23242]2023-09-17T23:34:56.792Z <ZWaveJSController:5:ZWaveJSController.js:1025> ZWaveJSController#zwavejs setting Cover#zwavejs>22-0.x_zwave_values.Window_Covering_currentValue_23 to 50
      [latest-23242]2023-09-17T23:34:56.807Z <HassController:INFO> HassController#hass action x_hass_cover.set_cover_tilt_position([Object]{ "tilt_position": 50 }) on Cover#hass>cover_dining_room2_horizontal_slats_angle succeeded
      [latest-23242]2023-09-17T23:34:56.809Z <Engine:INFO> Resuming reaction Blinds DR Open (re-kx6a2k13) from step 1
      [latest-23242]2023-09-17T23:34:56.810Z <Engine:NOTICE> Blinds DR Open delaying until 1694993697809<9/17/2023, 7:34:57 PM>
      [latest-23242]2023-09-17T23:34:56.930Z <ZWaveJSController:5:ZWaveJSController.js:798> ZWaveJSController#zwavejs handling node event statistics updated entity Cover#zwavejs>22-0
      [latest-23242]2023-09-17T23:34:57.811Z <Engine:INFO> Resuming reaction Blinds DR Open (re-kx6a2k13) from step 2
      [latest-23242]2023-09-17T23:34:57.812Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs performing zwave_device.refresh on Cover#zwavejs>7-0 with [Object]{  }
      [latest-23242]2023-09-17T23:34:57.814Z <ZWaveJSController:5:ZWaveJSController.js:1750> ZWaveJSController#zwavejs no implementation mapped; attempting default
      [latest-23242]2023-09-17T23:34:57.815Z <ZWaveJSController:5:ZWaveJSController.js:751> ZWaveJSController#zwavejs sending #1694993697815<9/17/2023, 7:34:57 PM>: [Object]{ "command": "node.refresh_values", "nodeId": 7, "messageId": 1694993697815 }
      [latest-23242]2023-09-17T23:34:57.830Z <ZWaveJSController:5:ZWaveJSController.js:778> ZWaveJSController#zwavejs command result error: [Object]{ "type": "result", "success": false, "messageId": 1694993697815, "errorCode": "node_not_found", "args": { "nodeId": 7 } }
      [latest-23242]2023-09-17T23:34:57.832Z <ZWaveJSController:ERR> ZWaveJSController#zwavejs request 1694993697815<9/17/2023, 7:34:57 PM> (node.refresh_values) failed: [Error] node_not_found [-]
      [latest-23242]2023-09-17T23:34:57.834Z <Engine:INFO> Resuming reaction Blinds DR Open (re-kx6a2k13) from step 3
      [latest-23242]2023-09-17T23:34:57.835Z <Engine:INFO> Blinds DR Open all actions completed.
      

      If you'd like the whole log I can upload that as well or anything else you need for review.

      *Hubitat C-7 2.4.3.173
      *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

      *HASS 2025.12.4, Core 2025.12.3
      w/ HA Connect ZWA-2
      FW: v1.1
      SDK: v7.23.1

      *Prod MSR in docker/portainer
      MSR: latest-25328-b2ed1365
      MQTTController: 25139
      ZWave Controller: 25139

      1 Reply Last reply
      0
      • toggledbitsT Offline
        toggledbitsT Offline
        toggledbits
        wrote on last edited by toggledbits
        #27

        Yeah, a clean log would be good to review. In your logging.yaml, please add the following (if there's already a section for ZWaveJSController, just modify it to make it look like this):

          ZWaveJSController:
            level: 5
            streams:
              - type: file
                name: zwavejs.log
                keep: 2
                level: 999
                recycle: true
        

        Restart Reactor and run a test (or a few) of cover.open and cover.close and position.set. Then copy just the zwavejs.log file up together with your latest zwavejs_devices_initial.json to link I sent you earlier. Thank you!

        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

        G T 2 Replies Last reply
        0
        • toggledbitsT toggledbits

          Yeah, a clean log would be good to review. In your logging.yaml, please add the following (if there's already a section for ZWaveJSController, just modify it to make it look like this):

            ZWaveJSController:
              level: 5
              streams:
                - type: file
                  name: zwavejs.log
                  keep: 2
                  level: 999
                  recycle: true
          

          Restart Reactor and run a test (or a few) of cover.open and cover.close and position.set. Then copy just the zwavejs.log file up together with your latest zwavejs_devices_initial.json to link I sent you earlier. Thank you!

          G Offline
          G Offline
          gwp1
          wrote on last edited by
          #28

          @toggledbits I actually had that logging enabled already and didn't realize/remember it.

          Scenarios tested:

          Test #1: 22-0 ~10:20 ET
          ZWJSC, cover.close
          Result: blind closed, "inside down"
          ZWJSC, cover.open
          Result: blind opened, position=50%
          Repeated, same results

          Test #2: 22-0
          ZWJSC, position.set = 0
          Result: blind closed, "inside up"
          ZWJSC, position.set = .5
          Result: blind opened, position=50%
          Repeated, same results

          Test #3: 22-0
          ZWJSC, cover.close
          Result: blind closed, "inside down"
          ZWJSC, cover.open
          Result: blind opened, position=50%
          Repeated, same results

          Unfortunately, everything WAI. Kinda frustrated at the moment. Same blind as last night's testing when nothing responded. Log being uploaded momentarily.

          *Hubitat C-7 2.4.3.173
          *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

          *HASS 2025.12.4, Core 2025.12.3
          w/ HA Connect ZWA-2
          FW: v1.1
          SDK: v7.23.1

          *Prod MSR in docker/portainer
          MSR: latest-25328-b2ed1365
          MQTTController: 25139
          ZWave Controller: 25139

          1 Reply Last reply
          0
          • toggledbitsT toggledbits

            Yeah, a clean log would be good to review. In your logging.yaml, please add the following (if there's already a section for ZWaveJSController, just modify it to make it look like this):

              ZWaveJSController:
                level: 5
                streams:
                  - type: file
                    name: zwavejs.log
                    keep: 2
                    level: 999
                    recycle: true
            

            Restart Reactor and run a test (or a few) of cover.open and cover.close and position.set. Then copy just the zwavejs.log file up together with your latest zwavejs_devices_initial.json to link I sent you earlier. Thank you!

            T Offline
            T Offline
            tamorgen
            wrote on last edited by
            #29

            @gwp1 ,
            Not to steal your thread, but out of curiosity, have you noticed any issues with battery life lately? I've noticed that a few of my iBlinds are draining very rapidly, ending in a unresponsive state. I've charged them, then less than a week later, they are dead and unresponsive.

            They all appear to be the older v2 iBlinds, so it could just be that the batteries are ending their useful life, however, it's also possible that the new configuration and command class is affecting them in some way. I'm gradually replacing them, as I've found the v3.1 iBlinds to be much more reliable. I haven't noticed this behavior in the v3.1 iBlinds.

            I'm just curious if you've seen this as well. If you are seeing it, it could be an issue with how ZWaveJS is communicating with the iBlinds due to this new roleout.

            G 1 Reply Last reply
            0
            • T tamorgen

              @gwp1 ,
              Not to steal your thread, but out of curiosity, have you noticed any issues with battery life lately? I've noticed that a few of my iBlinds are draining very rapidly, ending in a unresponsive state. I've charged them, then less than a week later, they are dead and unresponsive.

              They all appear to be the older v2 iBlinds, so it could just be that the batteries are ending their useful life, however, it's also possible that the new configuration and command class is affecting them in some way. I'm gradually replacing them, as I've found the v3.1 iBlinds to be much more reliable. I haven't noticed this behavior in the v3.1 iBlinds.

              I'm just curious if you've seen this as well. If you are seeing it, it could be an issue with how ZWaveJS is communicating with the iBlinds due to this new roleout.

              G Offline
              G Offline
              gwp1
              wrote on last edited by
              #30

              @tamorgen Not entirely stealing or off-topic as that has played a role before in iblind responsiveness. I have solar panels on mine - 50/50 on how well they work. My blinds are all v3.1, btw, @toggledbits, just as a point of reference.

              I have found if ZWaveJS HA Plugin shows anything under 60% battery the blinds become unresponsive. A quick plug of the power cable and a tap of the ping button and the physical button on the blind itself and they come back.

              For this specific topic, all tested blinds are either plugged in or showing 100% battery.

              *Hubitat C-7 2.4.3.173
              *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

              *HASS 2025.12.4, Core 2025.12.3
              w/ HA Connect ZWA-2
              FW: v1.1
              SDK: v7.23.1

              *Prod MSR in docker/portainer
              MSR: latest-25328-b2ed1365
              MQTTController: 25139
              ZWave Controller: 25139

              T 1 Reply Last reply
              0
              • G gwp1

                @tamorgen Not entirely stealing or off-topic as that has played a role before in iblind responsiveness. I have solar panels on mine - 50/50 on how well they work. My blinds are all v3.1, btw, @toggledbits, just as a point of reference.

                I have found if ZWaveJS HA Plugin shows anything under 60% battery the blinds become unresponsive. A quick plug of the power cable and a tap of the ping button and the physical button on the blind itself and they come back.

                For this specific topic, all tested blinds are either plugged in or showing 100% battery.

                T Offline
                T Offline
                tamorgen
                wrote on last edited by
                #31

                @gwp1,
                Thanks, I figured it couldn't hurt to ask someone else running HA to see if they were experiencing the same problems. I think it just might be old batteries.

                1 Reply Last reply
                0
                • T Offline
                  T Offline
                  tamorgen
                  wrote on last edited by
                  #32

                  @gwp1,
                  I'm working on trying to make something useful in the dashboards using this new device class, and it's not going well. I've reached out to iBlinds/Eric B for help. What we are both seeing as unknown/null states could be a problem.

                  There are three values that are null or unknown: cover.state, position.value, and then a repeat using the x_hass.state.
                  Capture4.PNG

                  When I go into Developer Tools in HA, the state is unknown as well. That makes sense since MSR has to grab it from somewhere.
                  Capture2.PNG I'm trying to work on my dashboard and display some useful information, and I'm unable to get the value of the attributes. I'm guessing that's because the State is unknown.
                  Capture5.PNG

                  Hopefully iBlinds can work with HA and ZWaveJS and get these values to show properly.

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by
                    #33

                    Yeah, logs confirm everything going out as expected, ZWJS acknowledging the request, and also sending a notification for a value change asynchronously. ZWaveJSController appears to be doing the right things. ZWaveJS appears to be doing its part as well.

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    G 1 Reply Last reply
                    0
                    • toggledbitsT toggledbits

                      Yeah, logs confirm everything going out as expected, ZWJS acknowledging the request, and also sending a notification for a value change asynchronously. ZWaveJSController appears to be doing the right things. ZWaveJS appears to be doing its part as well.

                      G Offline
                      G Offline
                      gwp1
                      wrote on last edited by gwp1
                      #34

                      @toggledbits I'm conducting an experiment.

                      DR2 blind (22-0) is configured as [Default] direction and using MSRs ZWJSController. I have set the three Reactions to:

                      DR OPEN: cover.open
                      DR CLOSE: cover.close
                      DR @25: position.set = .75 (resulting in the blind being tilted open 25%, "top inside").

                      All other iblinds are using HA's ZWJSC plugin and all ran flawlessly for the past 24 hours. I'm wondering if this issue is somehow load-induced. If this single blind remains solid I will add a second and so on.

                      UPDATE: as my patience level on any given day runs the gamut between saint and toddler I've added KITCHEN (18-0) to this test with the same settings as above excepting .80 instead of .75. Both of these iblinds were the most impacted in being unresponsive.

                      *Hubitat C-7 2.4.3.173
                      *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                      *HASS 2025.12.4, Core 2025.12.3
                      w/ HA Connect ZWA-2
                      FW: v1.1
                      SDK: v7.23.1

                      *Prod MSR in docker/portainer
                      MSR: latest-25328-b2ed1365
                      MQTTController: 25139
                      ZWave Controller: 25139

                      G 1 Reply Last reply
                      0
                      • G gwp1

                        @toggledbits I'm conducting an experiment.

                        DR2 blind (22-0) is configured as [Default] direction and using MSRs ZWJSController. I have set the three Reactions to:

                        DR OPEN: cover.open
                        DR CLOSE: cover.close
                        DR @25: position.set = .75 (resulting in the blind being tilted open 25%, "top inside").

                        All other iblinds are using HA's ZWJSC plugin and all ran flawlessly for the past 24 hours. I'm wondering if this issue is somehow load-induced. If this single blind remains solid I will add a second and so on.

                        UPDATE: as my patience level on any given day runs the gamut between saint and toddler I've added KITCHEN (18-0) to this test with the same settings as above excepting .80 instead of .75. Both of these iblinds were the most impacted in being unresponsive.

                        G Offline
                        G Offline
                        gwp1
                        wrote on last edited by gwp1
                        #35

                        @toggledbits we have fail!

                        Added two more iblinds to the test. They failed to respond so I isolated one of them and did the following tests on node 8-0:

                        LR Left OPEN: cover.open
                        LR Left CLOSE: cover.close
                        LR Left @20: position.set = .80 (resulting in the blind being tilted open 20%, "top inside").

                        Results:
                        cover.open = iblind opens, position of 50
                        cover.close = iblind moves to position of 50 <---expected result, position 0
                        position.set = iblind moves to position of 80

                        As this Reaction was to run BOTH left and right blinds I removed the right blind and ran the left solo as the kitchen and DR are (both still working fine, btw). For reference, Kitchen was existing unit and was re-interviewed to be current, DR is a brand new unit. LR's are existing units re-interviewed.

                        Log forthcoming.

                        *Hubitat C-7 2.4.3.173
                        *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                        *HASS 2025.12.4, Core 2025.12.3
                        w/ HA Connect ZWA-2
                        FW: v1.1
                        SDK: v7.23.1

                        *Prod MSR in docker/portainer
                        MSR: latest-25328-b2ed1365
                        MQTTController: 25139
                        ZWave Controller: 25139

                        toggledbitsT 1 Reply Last reply
                        0
                        • T Offline
                          T Offline
                          tamorgen
                          wrote on last edited by tamorgen
                          #36

                          @gwp1, I just replaced 6 of my ib2 motors with ib3.1, and they are working just fine (12 of 14 are v3.1). I can control them from MSR with ZWJSController without issue.

                          My only issue is actually Home Assistant itself. I've had to go to great lengths to get a somewhat working card for each of the blinds in my home, and I'm still not completely there yet. I'm hoping either the ZWaveJS devlopers or the HA developers figure out whats going on with the 'state' value for each of these, as they all return 'unknown', so none of the cards work out of the box.

                          G 1 Reply Last reply
                          0
                          • T tamorgen

                            @gwp1, I just replaced 6 of my ib2 motors with ib3.1, and they are working just fine (12 of 14 are v3.1). I can control them from MSR with ZWJSController without issue.

                            My only issue is actually Home Assistant itself. I've had to go to great lengths to get a somewhat working card for each of the blinds in my home, and I'm still not completely there yet. I'm hoping either the ZWaveJS devlopers or the HA developers figure out whats going on with the 'state' value for each of these, as they all return 'unknown', so none of the cards work out of the box.

                            G Offline
                            G Offline
                            gwp1
                            wrote on last edited by
                            #37

                            @tamorgen said in [SOLVED-ish] New iblind and zwaveJScontroller/MSR not communicating:

                            they are working just fine (12 of 14 are v3.1). I can control them from MSR with ZWJSController without issue.

                            It's more helpful if, instead of generalized statements, you provide settings/configurations you're using whilst having this success for comparison sake.

                            I ran into an issue this morning wherein, after completing the weekly zwave_device.set_config, the iblinds finish in a closed position but reporting back in all systems (HA, both ZWJSC's, and MSR) as 50 or open. I've created a workaround wherein, after completing the config, they wait a few seconds then tilt 20% and then set back to open.

                            *Hubitat C-7 2.4.3.173
                            *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                            *HASS 2025.12.4, Core 2025.12.3
                            w/ HA Connect ZWA-2
                            FW: v1.1
                            SDK: v7.23.1

                            *Prod MSR in docker/portainer
                            MSR: latest-25328-b2ed1365
                            MQTTController: 25139
                            ZWave Controller: 25139

                            T 1 Reply Last reply
                            0
                            • G gwp1

                              @tamorgen said in [SOLVED-ish] New iblind and zwaveJScontroller/MSR not communicating:

                              they are working just fine (12 of 14 are v3.1). I can control them from MSR with ZWJSController without issue.

                              It's more helpful if, instead of generalized statements, you provide settings/configurations you're using whilst having this success for comparison sake.

                              I ran into an issue this morning wherein, after completing the weekly zwave_device.set_config, the iblinds finish in a closed position but reporting back in all systems (HA, both ZWJSC's, and MSR) as 50 or open. I've created a workaround wherein, after completing the config, they wait a few seconds then tilt 20% and then set back to open.

                              T Offline
                              T Offline
                              tamorgen
                              wrote on last edited by tamorgen
                              #38

                              @gwp1 said in [SOLVED-ish] New iblind and zwaveJScontroller/MSR not communicating:

                              It's more helpful if, instead of generalized statements, you provide settings/configurations you're using whilst having this success for comparison sake.

                              All of mine are like this, cover.close, cover.open.

                              Perform cover.close on Office Blind Left (zwavejs>30-0)
                              Delay for 5 seconds
                              Perform cover.close on Office Blind Right (zwavejs>31-0)
                              Delay for 5 seconds
                              Perform zwave_device.refresh on Office Blind Left (zwavejs>30-0)
                              Perform zwave_device.refresh on Office Blind Right (zwavejs>31-0)
                              

                              I'm not even sure the zwave.device.refresh is needed anymore. This was more of an issue when trying to force the old device class to refresh on both the binary switch and the multi-level switch, as they weren't directly connected and didn't update each other. It was one of the reasons that the folks at iBlinds were pushing to get the window device class implemented.

                              G 1 Reply Last reply
                              0
                              • T tamorgen

                                @gwp1 said in [SOLVED-ish] New iblind and zwaveJScontroller/MSR not communicating:

                                It's more helpful if, instead of generalized statements, you provide settings/configurations you're using whilst having this success for comparison sake.

                                All of mine are like this, cover.close, cover.open.

                                Perform cover.close on Office Blind Left (zwavejs>30-0)
                                Delay for 5 seconds
                                Perform cover.close on Office Blind Right (zwavejs>31-0)
                                Delay for 5 seconds
                                Perform zwave_device.refresh on Office Blind Left (zwavejs>30-0)
                                Perform zwave_device.refresh on Office Blind Right (zwavejs>31-0)
                                

                                I'm not even sure the zwave.device.refresh is needed anymore. This was more of an issue when trying to force the old device class to refresh on both the binary switch and the multi-level switch, as they weren't directly connected and didn't update each other. It was one of the reasons that the folks at iBlinds were pushing to get the window device class implemented.

                                G Offline
                                G Offline
                                gwp1
                                wrote on last edited by
                                #39

                                @tamorgen I see you doing the delay as I do. How do you do a weekly config? (The blinds will "drift" if not config'd weekly or bi-weekly.

                                I have removed the zwave_device.refresh to see how that goes.

                                Question: you have a great number of blinds in your fleet as do I - how many blinds do you group together? I see you grouped two for your office blinds, do you have more than two at a time grouped in a single reaction? Or are you skipping reactions and adding each entity in each ruleset?

                                *Hubitat C-7 2.4.3.173
                                *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                                *HASS 2025.12.4, Core 2025.12.3
                                w/ HA Connect ZWA-2
                                FW: v1.1
                                SDK: v7.23.1

                                *Prod MSR in docker/portainer
                                MSR: latest-25328-b2ed1365
                                MQTTController: 25139
                                ZWave Controller: 25139

                                T 1 Reply Last reply
                                0
                                • G gwp1

                                  @tamorgen I see you doing the delay as I do. How do you do a weekly config? (The blinds will "drift" if not config'd weekly or bi-weekly.

                                  I have removed the zwave_device.refresh to see how that goes.

                                  Question: you have a great number of blinds in your fleet as do I - how many blinds do you group together? I see you grouped two for your office blinds, do you have more than two at a time grouped in a single reaction? Or are you skipping reactions and adding each entity in each ruleset?

                                  T Offline
                                  T Offline
                                  tamorgen
                                  wrote on last edited by tamorgen
                                  #40

                                  @gwp1 ,

                                  I really don't have any sort of weekly config on mine. I haven't noticed mine drifting at all, but a weekly recalibrate wouldn't be a bad idea.

                                  I have rules for hourly refreshing the the cover, position, and switch positions that are now pretty much legacy of the old device class. I only have two of the IB2 devices left, and they're in non critical rooms ( guest bedroom and mudroom). I'll replace those later this year. Once those are gone, I'll be able to remove those three hourly rules.

                                  I have reactions set up for each set of windows in a room. Most rooms only have two windows, so I group those. The lone exception is my family room, where I have four windows, but on different walls. I have those set up on two separate reactions, which allows me to separately set the blinds to a partial open position when the sun is shining directly in. The largest events with the blinds are at sunrise, sunset, and when the house is vacant or someone arrives, when I'll set the reactions from the rule, and I have "Wait for completion" enabled after each call for a reaction. It takes a couple of minutes for all my blinds to open/close when it's called. I initially didn't do this, but iBlinds recommended not calling them all at once (thus the pause in between each call for a blind to open/close). For the most part, this has helped tremendously with the IB2 motors, although they still had their fair share of problems, which is why I've been replacing them all this year.

                                  I call the reactions from rulesets, so I don't have to reinvent the wheel each time I want to perform an action on a window. It also allows me to make an adjustment once and not 10 different times in different rules.

                                  G 1 Reply Last reply
                                  0
                                  • T tamorgen

                                    @gwp1 ,

                                    I really don't have any sort of weekly config on mine. I haven't noticed mine drifting at all, but a weekly recalibrate wouldn't be a bad idea.

                                    I have rules for hourly refreshing the the cover, position, and switch positions that are now pretty much legacy of the old device class. I only have two of the IB2 devices left, and they're in non critical rooms ( guest bedroom and mudroom). I'll replace those later this year. Once those are gone, I'll be able to remove those three hourly rules.

                                    I have reactions set up for each set of windows in a room. Most rooms only have two windows, so I group those. The lone exception is my family room, where I have four windows, but on different walls. I have those set up on two separate reactions, which allows me to separately set the blinds to a partial open position when the sun is shining directly in. The largest events with the blinds are at sunrise, sunset, and when the house is vacant or someone arrives, when I'll set the reactions from the rule, and I have "Wait for completion" enabled after each call for a reaction. It takes a couple of minutes for all my blinds to open/close when it's called. I initially didn't do this, but iBlinds recommended not calling them all at once (thus the pause in between each call for a blind to open/close). For the most part, this has helped tremendously with the IB2 motors, although they still had their fair share of problems, which is why I've been replacing them all this year.

                                    I call the reactions from rulesets, so I don't have to reinvent the wheel each time I want to perform an action on a window. It also allows me to make an adjustment once and not 10 different times in different rules.

                                    G Offline
                                    G Offline
                                    gwp1
                                    wrote on last edited by
                                    #41

                                    @tamorgen we are very much aligned in our approach.

                                    • My office has four windows, one front-facing and three smaller side-facing. I group the three together.
                                    • My main room covers the single kitchen, single dining room, and two paired living room blinds.
                                    • My master bedroom has two paired together, the master bath a single that I do not group with the bedroom.
                                    • Guest rooms are single independents.

                                    I, too, do reactions for:

                                    • open (Day)
                                    • close (Evening/Night)
                                    • tilt (this is used for Away for all, also for "sun defer" as the sun moves around the house)

                                    I do reactions as well for the very same reason: single place to edit. I know @toggledbits will cringe but my "Open ALL" , "Tilt ALL", and "Close ALL" are reactions that contain the other room-specific reactions and are called by rulesets.

                                    I've increased my delays again back to 00:00:05 (was down to 00:00:02) just to see if that may help the initial issue that spawned this topic. I don't need to have all blinds close at once (sure, it would be cool) - it's still fun for guests when the actions start in the office at the front of the house and just file their way around until all are completed.

                                    *Hubitat C-7 2.4.3.173
                                    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                                    *HASS 2025.12.4, Core 2025.12.3
                                    w/ HA Connect ZWA-2
                                    FW: v1.1
                                    SDK: v7.23.1

                                    *Prod MSR in docker/portainer
                                    MSR: latest-25328-b2ed1365
                                    MQTTController: 25139
                                    ZWave Controller: 25139

                                    1 Reply Last reply
                                    0
                                    • G gwp1

                                      @toggledbits we have fail!

                                      Added two more iblinds to the test. They failed to respond so I isolated one of them and did the following tests on node 8-0:

                                      LR Left OPEN: cover.open
                                      LR Left CLOSE: cover.close
                                      LR Left @20: position.set = .80 (resulting in the blind being tilted open 20%, "top inside").

                                      Results:
                                      cover.open = iblind opens, position of 50
                                      cover.close = iblind moves to position of 50 <---expected result, position 0
                                      position.set = iblind moves to position of 80

                                      As this Reaction was to run BOTH left and right blinds I removed the right blind and ran the left solo as the kitchen and DR are (both still working fine, btw). For reference, Kitchen was existing unit and was re-interviewed to be current, DR is a brand new unit. LR's are existing units re-interviewed.

                                      Log forthcoming.

                                      toggledbitsT Offline
                                      toggledbitsT Offline
                                      toggledbits
                                      wrote on last edited by
                                      #42

                                      @gwp1 said in [SOLVED-ish] New iblind and zwaveJScontroller/MSR not communicating:

                                      Log forthcoming.

                                      Looked at the log. ZWaveJSController is consistently, correctly issuing the right commands and values for all actions in every case. ZWaveJS is responding with a successful acknowledgement of the command, and later passing an update notification with the node's position having a value consistent with the command previously given in every case. It appears that ZWaveJS understands what MSR is asking it to do, sending that to the device, and the device is sending back updates indicating it has done what has been asked. If that's not what the device actually does, then I assert it's firmware or hardware issue with the device.

                                      The log contains errors for an attempt to refresh (using the zwave_device.refresh action) non-existent node 7 (that is, ZWaveJS reports that the node doesn't exist; the entity may still exist as a zombie). That has no effect operationally, just bringing to your attention that after excluding/including devices, you may have missed a now-dead entity.

                                      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                      G 1 Reply Last reply
                                      0
                                      • toggledbitsT toggledbits

                                        @gwp1 said in [SOLVED-ish] New iblind and zwaveJScontroller/MSR not communicating:

                                        Log forthcoming.

                                        Looked at the log. ZWaveJSController is consistently, correctly issuing the right commands and values for all actions in every case. ZWaveJS is responding with a successful acknowledgement of the command, and later passing an update notification with the node's position having a value consistent with the command previously given in every case. It appears that ZWaveJS understands what MSR is asking it to do, sending that to the device, and the device is sending back updates indicating it has done what has been asked. If that's not what the device actually does, then I assert it's firmware or hardware issue with the device.

                                        The log contains errors for an attempt to refresh (using the zwave_device.refresh action) non-existent node 7 (that is, ZWaveJS reports that the node doesn't exist; the entity may still exist as a zombie). That has no effect operationally, just bringing to your attention that after excluding/including devices, you may have missed a now-dead entity.

                                        G Offline
                                        G Offline
                                        gwp1
                                        wrote on last edited by gwp1
                                        #43

                                        @toggledbits Node 7-0 has cleaned itself up in MSR (it was cleared out in HA's ZWJSC). I got the same from the logs, was hoping you would see something I missed.

                                        The firmware is on the latest. I'll doublecheck the firmware on the ZWave Stick that runs these from HA. Thanks @toggledbits, as usual.

                                        Updating this thread to [SOLVED] as whatever the issue may be it's not MSR's.

                                        *Hubitat C-7 2.4.3.173
                                        *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                                        *HASS 2025.12.4, Core 2025.12.3
                                        w/ HA Connect ZWA-2
                                        FW: v1.1
                                        SDK: v7.23.1

                                        *Prod MSR in docker/portainer
                                        MSR: latest-25328-b2ed1365
                                        MQTTController: 25139
                                        ZWave Controller: 25139

                                        1 Reply Last reply
                                        0
                                        • G Offline
                                          G Offline
                                          gwp1
                                          wrote on last edited by
                                          #44

                                          A final update here... adding in a minimum of 00:00:05 delays has resolved the issues.

                                          *Hubitat C-7 2.4.3.173
                                          *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

                                          *HASS 2025.12.4, Core 2025.12.3
                                          w/ HA Connect ZWA-2
                                          FW: v1.1
                                          SDK: v7.23.1

                                          *Prod MSR in docker/portainer
                                          MSR: latest-25328-b2ed1365
                                          MQTTController: 25139
                                          ZWave Controller: 25139

                                          1 Reply Last reply
                                          0
                                          • toggledbitsT toggledbits locked this topic on
                                          Reply
                                          • Reply as topic
                                          Log in to reply
                                          • Oldest to Newest
                                          • Newest to Oldest
                                          • Most Votes


                                          Recent Topics

                                          • [HowTo] Using HABridge with Reactor
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            9
                                            360

                                          • [Reactor] Bug when sending MQTT boolean payloads
                                            toggledbitsT
                                            toggledbits
                                            0
                                            4
                                            113

                                          • Genuinely impressed with Zigbee and HA / Reactor
                                            therealdbT
                                            therealdb
                                            1
                                            8
                                            267

                                          • Difficulty defining repeating annual period
                                            G
                                            gwp1
                                            0
                                            5
                                            65

                                          • Need help with sequence
                                            therealdbT
                                            therealdb
                                            0
                                            3
                                            38

                                          • Possible feature request?
                                            therealdbT
                                            therealdb
                                            0
                                            5
                                            148

                                          • Copying a global reaction
                                            tunnusT
                                            tunnus
                                            0
                                            1
                                            41

                                          • Logic Assistance: Exterior Lights on when Illuminance Below Threshold
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            11
                                            320

                                          • Time series documentation
                                            tunnusT
                                            tunnus
                                            0
                                            11
                                            378

                                          • MQTT templates for ZIgbee scene controller, or a better way?
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            3
                                            147

                                          • Reset a delay
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            8
                                            208
                                          Powered by NodeBB | Contributors
                                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                          • Login

                                          • Don't have an account? Register

                                          • Login or register to search.
                                          • First post
                                            Last post
                                          0
                                          • Categories
                                          • Recent
                                          • Tags
                                          • Popular
                                          • Unsolved