Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. Gradually turn on lights.
Oddness in Copy/Move of Reactions
G
Topic thumbnail image
Multi-System Reactor
[Solved] function isRuleEnabled() issue
CrilleC
Topic thumbnail image
Multi-System Reactor
[Reactor] Problem with Global Reactions and groups
therealdbT
Topic thumbnail image
Multi-System Reactor
Possible feature request 2?
CatmanV2C
Just another thought. Adding devices from my Home Assistant / Zigbee2MQTT integration. Works perfectly but they always add as their IEEE address. Some of these devices have up to 10 entities associated, and the moment they are renamed to something sensible, each of those entities 'ceases to exist' in MSR. I like things tidy, and deleting each defunct entity needs 3 clicks. Any chance of a 'bulk delete' option? No biggy as I've pretty much finished my Z-wave migration and I don't expect to be adding more than 2 new Zigbee devices Cheers C
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Copying a global reaction
tunnusT
With build 25328, if you copy a global reaction, a new reaction does not appear in the UI unless you do a refresh. I recall this used to work without needing this page refresh? Anyway, only a minor nuisance.
Multi-System Reactor
[Reactor] Bug when sending MQTT boolean payloads
therealdbT
Topic thumbnail image
Multi-System Reactor
Difficulty defining repeating annual period
R
I have tried numerous ways to define a recurring annual period, for example from December 15 to January 15. No matter which method I try - after and before, between, after and/not after, Reactor reports "waiting for invalid date, invalid date. Some constructs also seem to cause Reactor to hang, timeout and restart. For example "before January 15 is evaluated as true, but reports "waiting for invalid date, invalid date". Does anyone have a tried and true method to define a recurring annual period? I think the "between" that I used successfully in the past may have broken with one of the updates.
Multi-System Reactor
Need help with sequence
T
Good evening all, For about the past week or so, I've been having problems with a specific rule in my home automation that controls when my home goes from an Away mode to Home mode. One of the conditions it checked for was my alarm panel, when it changed from Armed Away to Disarmed. There seems to have been a firmware update on the panel that added an intermittent step of "pending", and I can't say for certain it happens 100% of the time. Is there a way to write a condition that so it changes from one condition, to the next, and then another condition? As in, Home alarm changes from armed_away to pending to disarmed. Thanks.
Multi-System Reactor
Possible feature request?
CatmanV2C
No idea how easy this would be. During my migration away from Z-wave I've been replacing the Z-wave devices with Sonoff which has broken some of my automations. Any chance of a 'Test Reaction' function to call out which ones are broken because an entity no longer exists? Without actually running the reaction? Or does this exist already and I'm just not aware of how to do it? Obviously I can see entities that are no longer available, but not quite what I'm looking for. I guess it's something of an edge case so no huge issue. TIA! C
Multi-System Reactor
Logic Assistance: Exterior Lights on when Illuminance Below Threshold
PablaP
Topic thumbnail image
Multi-System Reactor
Time series documentation
tunnusT
Is the current manual (incl. examples) up to date with how retention value is handled in time series configuration? Referring to this post
Multi-System Reactor
MQTT templates for ZIgbee scene controller, or a better way?
CatmanV2C
Topic thumbnail image
Multi-System Reactor
Reset a delay
CatmanV2C
I'm sure this has been asked, and answered, but damned if I can figure it out Use case: I have a rear garden with lights. A door from the kitchen into the garden and a door from the garage. Currently if I open the kitchen door the lights come on (yay) and a 3 minute delay starts. After 3 minutes, no matter what else happens, the lights go off (Boo! But also yay!) What I would like is for the 3 minute delay until the lights go off to start from the latest door open event. That is, if I'm going from kitchen to garage, and back again, the lights stay on until there's three minutes of no activity. I've tried 'hacking' with a virtual switch, but can't seem to stop the delay. Any pointers? TIA C
Multi-System Reactor
Reactor Loading Screen Safari
S
Topic thumbnail image
Multi-System Reactor
Constraints states visually do not match actual
S
Topic thumbnail image
Multi-System Reactor
[MSR] Feature request: For Each action on arrays/groups
therealdbT
Topic thumbnail image
Multi-System Reactor
[Solved] Error: Command timeout
G
at _ClientAPI._commandTimeout (http://192.168.1.100:8111/client/ClientAPI.js:807:179 Seeing this randomly when returning to open browser tab after being away awhile. Once, maybe twice a day. "What did you do to trigger it?" Literally nothing, just walked away and returned and there it was. Actions taken in reasonably close proximity to this particular instance of it popping up: I'd restarted the MSR container in Portainer. I'll try to grab some logs here shortly.
Multi-System Reactor
Issue with MSR UI becoming unresponsive
S
I'm having an issue with MSR's UI being very unresponsive. It started happening a couple days ago and I didn't make any changes that would have caused this except adding some meross lan devices in HA. When I go into an entity action and use the search functionality, it usually will start filtering and then get to a place after a few letters are entered where it will take 30 seconds or more (sometimes minutes) for the UI to show what I am typing. During this time MSR ui is completely unresponsive. I've tried multiple browsers and multiple computers. HA and MSR are both deployed in docker. I have run HTOP on the host and when the problem happens there are no CPU/Memory spikes at all. From a functionality standpoint MSR is working perfectly. This seems to be an UI issue only. Do i need to ditch Docker and run MSR on a Proxmox VM? I have both stand alone Docker and Proxmox environments. I dont mind doing that I just want to be able to use the UI again... Installation method Home Assistant Container Core 2025.7.3 Frontend 20250702.3 nothing crazy in the logs except some openweather map stuff that doesn't make any sense as it is working fine in MSR Any help would be greatly appreciated Reactor latest-25328-b2ed1365 app 25328 configuration from /var/reactor/config NODE_PATH /opt/reactor:/opt/reactor/node_modules [latest-25328]2025-11-30T20:01:53.843Z <app:null> Reactor build latest-25328-b2ed1365 starting on v24.11.1 /usr/local/bin/node [latest-25328]2025-11-30T20:01:53.844Z <app:null> Process ID 1 user/group 0/0; docker; platform linux/x64 #161-Ubuntu SMP Tue Jul 22 14:25:40 UTC 2025; locale (undefined) [latest-25328]2025-11-30T20:01:53.844Z <app:null> Basedir /opt/reactor; data in /var/reactor/storage [latest-25328]2025-11-30T20:01:53.844Z <app:null> NODE_PATH=/opt/reactor:/opt/reactor/node_modules [latest-25328]2025-11-30T20:01:53.865Z <app:null> Resolved timezone=America/New_York, environment TZ=America/New_York; offset minutes from UTC=-300 [latest-25328]2025-11-30T20:01:53.867Z <default:null> Module i18n v25141 [latest-25328]2025-11-30T20:01:53.867Z <app:null> Configured locale (undefined); selected locale(s) en-US.UTF-8 [latest-25328]2025-11-30T20:01:53.879Z <app:null> Loaded locale en-US for en-US [latest-25328]2025-11-30T20:01:53.879Z <app:null> Local date/time using configured timezone and locale formatting is "11/30/2025, 3:01:53 PM" [latest-25328]2025-11-30T20:01:53.889Z <Structure:null> Module Structure v25326 [latest-25328]2025-11-30T20:01:53.890Z <Capabilities:null> Module Capabilities v24312 [latest-25328]2025-11-30T20:01:53.904Z <Plugin:null> Module Plugin v25141 [latest-25328]2025-11-30T20:01:53.923Z <Timer:null> Module Timer v25279 [latest-25328]2025-11-30T20:01:53.924Z <TimerBroker:null> Module TimerBroker v25314 [latest-25328]2025-11-30T20:01:53.927Z <Entity:null> Module Entity v25251 [latest-25328]2025-11-30T20:01:53.929Z <Controller:null> Module Controller v25253 [latest-25328]2025-11-30T20:01:53.930Z <AlertManager:null> Module AlertManager v25318 [latest-25328]2025-11-30T20:01:53.937Z <default:null> Module Ruleset v25283 [latest-25328]2025-11-30T20:01:53.937Z <default:null> Module Rulesets v25141 [latest-25328]2025-11-30T20:01:53.942Z <GlobalExpression:null> Module GlobalExpression v25258 [latest-25328]2025-11-30T20:01:53.953Z <Predicate:null> Module Predicate v25328 [latest-25328]2025-11-30T20:01:53.956Z <Rule:null> Module Rule v25323 [latest-25328]2025-11-30T20:01:53.958Z <GlobalReaction:null> Module GlobalReaction v25292 [latest-25328]2025-11-30T20:01:53.959Z <Engine:null> Module Engine v25325 [latest-25328]2025-11-30T20:01:53.964Z <httpapi:null> Module httpapi v25328 [latest-25328]2025-11-30T20:01:53.972Z <wsapi:null> Module wsapi v25328 [latest-25328]2025-11-30T20:01:53.994Z <TaskQueue:null> Module TaskQueue 24138 [latest-25328]2025-11-30T20:01:53.994Z <VeraController:null> Module VeraController v25141 [latest-25328]2025-11-30T20:01:54.179Z <HassController:null> Module HassController v25325 [latest-25328]2025-11-30T20:02:13.797Z <OWMWeatherController:null> Module OWMWeatherController v25268 [latest-25328]2025-11-30T20:02:13.800Z <SystemController:null> Module SystemController v25323 [latest-25328]2025-11-30T20:02:13.807Z <MQTTController:null> Module MQTTController v22092 [latest-25328]2025-11-30T20:02:20.630Z <OWMWeatherController:CRIT> FetchError: request to https://api.openweathermap.org/data/2.5/weather?lat=xxxxxxxxxx&lon=-xxxxxxxxx&appid=xxxxxxxxxxxxxxxxxxxxxxxxxx&units=standard&_r=1xxxxxxxxxxxxxxfailed, reason: [-] FetchError: request to https://api.openweathermap.org/data/2.5/weather?lat=xxxxxxxxxxx&lon=-xxxxxxxxxxxxxxxxxx&appid=xxxxxxxxxxxxxxxxxxx&units=standard&_r=xxxxxxxxxxxxxxxfailed, reason: at ClientRequest.<anonymous> (/opt/reactor/node_modules/node-fetch/lib/index.js:1501:11) at ClientRequest.emit (node:events:508:28) at ClientRequest.emit (node:domain:489:12) at emitErrorEvent (node:_http_client:108:11) at TLSSocket.socketErrorListener (node:_http_client:575:5) at TLSSocket.emit (node:events:508:28) at TLSSocket.emit (node:domain:489:12) at emitErrorNT (node:internal/streams/destroy:170:8) at emitErrorCloseNT (node:internal/streams/destroy:129:3) at processTicksAndRejections (node:internal/process/task_queues:89:21
Multi-System Reactor
Date/time condition
tunnusT
Topic thumbnail image
Multi-System Reactor

Gradually turn on lights.

Scheduled Pinned Locked Moved Solved Multi-System Reactor
21 Posts 6 Posters 3.2k Views 6 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • V vezinpi

    @toggledbits I am having some difficulty implementing the suggested approach. In my case, what you suggested above worked but with some limitations. Maybe due to the fact that I am not using the Z-Wave controller but Z-Wave JS UI.

    I have created the same rule as you suggested but to better understand what is happening I perform some test from the "Entities" menu.

    1- The "dimming.step" when changed does not stick after a dimming.up/down

    In the "Entities" menu I set the attribute "dimming.step" to 0.05. Still in the etities menu, I then perform a "dimming.up" and can confirm that indeed the "dimming.level" went up by 0.05 however at the same time the dimming.step goes back to 0.1 (default). From that point, any subsequent "dimming.up" uses the default.

    2- The dimming.up does not exceed the previous level (This might be normal but a bit difficult to manage?)

    If the dimming level was set to 60% and then turn off, performing a "dimming up" will not go beyond 60%. So implementing the rule as suggested, make an infinite while since .99 is never reached.

    I tried this on 2 type of z-wave devices with the same result.

    Thanks in advance

    G Offline
    G Offline
    gwp1
    wrote on last edited by
    #7

    @vezinpi can you share screenshots of the rules?

    I implemented this and it appears to be working fine (though I want to do some fine tuning).

    *Hubitat C-7 2.4.3.177
    *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

    *HAOS
    Core 2026.1.1
    w/ HA Connect ZWA-2
    FW: v1.1
    SDK: v7.23.1

    *Prod MSR in docker/portainer
    MSR: latest-26011-c621bbc7
    MQTTController: 25139
    ZWave Controller: 25139

    1 Reply Last reply
    0
    • V Offline
      V Offline
      vezinpi
      wrote on last edited by
      #8

      @gwp1 Here is the screen capture. It is basically a copy of what toggledbits provided. Keep in mind that it is working fine with the default dimming.step and if your dimmer is normally set to 100% before being turned off.

      From the screen capture you can see that, in my case, the "Current value" is 0.59...This is as high as it will go if the previous state of the dimmer was 60%. This situation causes the while to repeat every 2 second indefinitely. I have to kill it in the "running reaction" status screen or to disable the rule.

      image.png

      G 1 Reply Last reply
      0
      • V vezinpi

        @gwp1 Here is the screen capture. It is basically a copy of what toggledbits provided. Keep in mind that it is working fine with the default dimming.step and if your dimmer is normally set to 100% before being turned off.

        From the screen capture you can see that, in my case, the "Current value" is 0.59...This is as high as it will go if the previous state of the dimmer was 60%. This situation causes the while to repeat every 2 second indefinitely. I have to kill it in the "running reaction" status screen or to disable the rule.

        image.png

        G Offline
        G Offline
        gwp1
        wrote on last edited by
        #9

        @vezinpi mine is as such:

        c49d3fa7-b5b0-429b-8546-46936b06bf7c-image.png

        Here's the rule's Set Reaction that pulls this in.

        07704c8c-6a37-4c7b-b67f-d8285f955bad-image.png

        I also have another group under this same rule's Set Reaction for Evenings.

        0cd4a81b-ea76-43b7-a6a5-a7c6e719ab28-image.png

        Everything I've seen shows this as working as intended. Only rises to 30% in the mornings, 80% at night. Only the mornings get the slow roll ramp up.

        *Hubitat C-7 2.4.3.177
        *Proxmox VE v8, Beelink MiniPC 12GBs, SSD

        *HAOS
        Core 2026.1.1
        w/ HA Connect ZWA-2
        FW: v1.1
        SDK: v7.23.1

        *Prod MSR in docker/portainer
        MSR: latest-26011-c621bbc7
        MQTTController: 25139
        ZWave Controller: 25139

        1 Reply Last reply
        0
        • V Offline
          V Offline
          vezinpi
          wrote on last edited by
          #10
          This post is deleted!
          1 Reply Last reply
          0
          • V Offline
            V Offline
            vezinpi
            wrote on last edited by vezinpi
            #11

            Hi again, more accurate info for the "Perform dimming.up/down"

            I have just made a test from the entity menu. Using the default dimming.step (0.1) I did the following starting with the dimmer off:

            1- Perform dimming.up 10 times

            This should have brought the dimmer to 100% but it did stop at 60% (0.59...)

            2- Perform dimming.down 10 times

            This should have brought the dimmer to 0% but it did stop at 50%

            From 100%, I can only dimmed.down to 50%
            from 0%, I can only dimmed.up to 60% (0.59)

            The dimming.set "value" works all the time

            Here is the log from Z-Wave JS for the 10x dimming.up followed by the 10x dimming.down test.

            2025-07-07 23:32:00.315 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 0 => 10
            2025-07-07 23:32:00.328 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 10 => 10
            2025-07-07 23:32:03.828 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 10 => 20
            2025-07-07 23:32:03.834 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 10 => 20
            2025-07-07 23:32:03.854 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 20 => 20
            2025-07-07 23:32:06.007 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 20 => 30
            2025-07-07 23:32:06.014 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 20 => 30
            2025-07-07 23:32:06.045 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 30 => 30
            2025-07-07 23:32:08.149 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 30 => 40
            2025-07-07 23:32:08.152 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 30 => 40
            2025-07-07 23:32:08.165 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 40 => 40
            2025-07-07 23:32:10.289 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 40 => 50
            2025-07-07 23:32:10.295 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 40 => 50
            2025-07-07 23:32:10.308 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:12.397 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 59
            2025-07-07 23:32:12.401 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 59
            2025-07-07 23:32:12.416 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:14.848 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 59 => 59
            2025-07-07 23:32:14.853 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:14.866 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:16.744 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 59 => 59
            2025-07-07 23:32:16.749 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:16.762 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:18.651 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 59 => 59
            2025-07-07 23:32:18.654 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:18.665 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:20.649 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 59 => 59
            2025-07-07 23:32:20.652 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:20.661 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 59
            2025-07-07 23:32:22.864 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 59 => 50
            2025-07-07 23:32:22.870 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 59 => 50
            2025-07-07 23:32:22.881 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:26.963 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:26.966 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:26.975 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:29.030 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:29.035 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:29.052 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:31.234 DEBUG Z-WAVE: Polling value 49-0-Air temperature
            2025-07-07 23:32:31.289 INFO Z-WAVE: [Node 036] Metadata updated: 49-0-Air temperature
            2025-07-07 23:32:31.292 INFO Z-WAVE: [Node 036] Value updated: 49-0-Air temperature 24 => 24
            2025-07-07 23:32:31.297 DEBUG Z-WAVE: 36-49-0-Air temperature will be polled in 60 seconds
            2025-07-07 23:32:31.715 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:31.718 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:31.727 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:34.557 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:34.562 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:34.578 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:36.379 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:36.384 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:36.398 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:38.130 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:38.133 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:38.141 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:39.756 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:39.759 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:39.767 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:41.731 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:41.737 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:41.756 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:43.814 INFO Z-WAVE: [Node 005] Value updated: 38-0-targetValue 50 => 50
            2025-07-07 23:32:43.819 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50
            2025-07-07 23:32:43.828 INFO Z-WAVE: [Node 005] Value updated: 38-0-currentValue 50 => 50 ~~~
            1 Reply Last reply
            0
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by toggledbits
              #12

              Sounds like you might have dimming.minimum on the entity set to 0.1? And what of dimming.maximum? Failing that, does the device itself have min/max set in its Z-Wave configuration?

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              0
              • V Offline
                V Offline
                vezinpi
                wrote on last edited by
                #13

                Hi,

                The dimming.maximum/minimum are set to 1 and 0

                image.png

                @toggledbits said in Gradually turn on lights.:

                Failing that, does the device itself have min/max set in its Z-Wave configuration?

                Not sure exactely how to check this. The device is a Zooz ZEN 72. I look in the Z-Wave JS UI and could not find any parameter that would limit the dimming min/max.

                I might be wrong here but it is my understanding that the Z-Wave JS UI sits between HA and the devices. Since the Z-Wave JS UI log shows that any level change request above 60 from MSR, stays at 60, it can only be coming from MSR or HA. In addition the dimming.set works without any issues.

                1 Reply Last reply
                0
                • toggledbitsT Offline
                  toggledbitsT Offline
                  toggledbits
                  wrote on last edited by
                  #14

                  OK. There are some rounding issues with JavaScript, and I think I can tune things up to work around them a little better. Stay tuned.

                  Also, tip: use the Copy Attributes button instead of screen-grabbing the attributes. Gives more data.

                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by
                    #15

                    Yup, a lot going on here. ZWave and ZWave-JS produce values for brightness in the range 0-99. HA maps that into its 0-255 scale, so precision oddities are introduced there. HassController then attempts to scale HA's 0-255 into Reactor's 0-1, which introduces more precision oddities.

                    I've made an interim build with a handful of adjustments. It is published only for docker aarch64/arm64 (RPi 64-bit and similar) right now, because I don't have time to repackage the whole thing for all platforms right now (I'll be unavailable from 11th through 20th), and it's too risky. For others reading, I don't recommend going to this build unless you need this specific fix immediately.

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    1 Reply Last reply
                    0
                    • V Offline
                      V Offline
                      vezinpi
                      wrote on last edited by
                      #16

                      @toggledbits Thank you for looking into this.

                      There is absolutely no rush on any of this on my side. When I read the post I really liked the approach you suggested and made a test rule to see how I could use it and got into some issues.

                      Since you took the time to make an interim built, I will take the time to test it and report back here with the result. This way, you will know the status when you return.

                      Thanks again

                      1 Reply Last reply
                      0
                      • V Offline
                        V Offline
                        vezinpi
                        wrote on last edited by vezinpi
                        #17

                        Loaded the new built and as expected, the dimming.up/down are working for all levels. I also noticed that the dimming.level reported are nicely round up to one digit after the "." except for 50% where it displays "0.51" (not really an isssue just reporting what I see)

                        However, the other issue mentionned my opening post (that got kind of forgotten) is still present. Here is the refference:

                        said in Gradually turn on lights.:

                        1- The "dimming.step" when changed does not stick after a dimming.up/down

                        In the "Entities" menu I set the attribute "dimming.step" to 0.05. Still in the etities menu, I then perform a "dimming.up" and can confirm that indeed the "dimming.level" went up by 0.05 however at the same time the dimming.step goes back to 0.1 (default). From that point, any subsequent "dimming.up" uses the default.

                        Again, this can wait until your next release if a fix is indeed needed.

                        1 Reply Last reply
                        0
                        • toggledbitsT Offline
                          toggledbitsT Offline
                          toggledbits
                          wrote on last edited by toggledbits
                          #18

                          Have you done a hard refresh on the browser? If that's not it, check file permissions on your storage directory, and also check the logs to see if any errors are emitted when you change the attribute value and within the window of about two minutes after (allowing for the delayed-write strategy caching). The other likely issue is that your storage directory has issues and isn't properly saving the state data for the entity.

                          Edit: Well, I said:

                          There is no code that changes dimming.step other than the button you use on the UI.

                          And that's technically true, there's no code, but... seems there is a stray directive in the entity mapping data table hass_devices.yaml, which is specific to HassController, left over from wayyyyy long ago that should not be there today, and will do what you are observing. Simple fix. I'll roll a new docker image shortly.

                          Edit 2: Updated container is up and ready.

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          1 Reply Last reply
                          0
                          • V Offline
                            V Offline
                            vezinpi
                            wrote on last edited by
                            #19

                            As usual, you nailed it!

                            With a dimming.step of 0.03, it does a very nice gradation.

                            Many thanks

                            1 Reply Last reply
                            0
                            • T Offline
                              T Offline
                              tbully
                              wrote on last edited by
                              #20

                              I'm having this same issue with a bare metal install. I assume this fix will be included in a future release? (No hurry. This is just a nice-to-have thing...)

                              toggledbitsT 1 Reply Last reply
                              0
                              • T tbully

                                I'm having this same issue with a bare metal install. I assume this fix will be included in a future release? (No hurry. This is just a nice-to-have thing...)

                                toggledbitsT Offline
                                toggledbitsT Offline
                                toggledbits
                                wrote on last edited by
                                #21

                                @tbully said in Gradually turn on lights.:

                                I'm having this same issue with a bare metal install. I assume this fix will be included in a future release? (No hurry. This is just a nice-to-have thing...)

                                The 25208 build released yesterday includes the fixes in the temporary containers built for @vezinpi and others on this thread.

                                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                1 Reply Last reply
                                1
                                • toggledbitsT toggledbits locked this topic on
                                Reply
                                • Reply as topic
                                Log in to reply
                                • Oldest to Newest
                                • Newest to Oldest
                                • Most Votes


                                Recent Topics

                                • Oddness in Copy/Move of Reactions
                                  G
                                  gwp1
                                  0
                                  1
                                  21

                                • [Solved] function isRuleEnabled() issue
                                  CrilleC
                                  Crille
                                  0
                                  4
                                  28

                                • [Reactor] Problem with Global Reactions and groups
                                  therealdbT
                                  therealdb
                                  0
                                  3
                                  48

                                • Possible feature request 2?
                                  CatmanV2C
                                  CatmanV2
                                  0
                                  3
                                  40

                                • Reactor (Multi-System/Multi-Hub) Announcements
                                  toggledbitsT
                                  toggledbits
                                  5
                                  133
                                  79.4k

                                • Genuinely impressed with Zigbee and HA / Reactor
                                  CatmanV2C
                                  CatmanV2
                                  1
                                  9
                                  339

                                • Copying a global reaction
                                  toggledbitsT
                                  toggledbits
                                  0
                                  3
                                  86

                                • [HowTo] Using HABridge with Reactor
                                  CatmanV2C
                                  CatmanV2
                                  0
                                  9
                                  403

                                • [Reactor] Bug when sending MQTT boolean payloads
                                  toggledbitsT
                                  toggledbits
                                  0
                                  4
                                  141

                                • Difficulty defining repeating annual period
                                  G
                                  gwp1
                                  0
                                  5
                                  107

                                • Need help with sequence
                                  therealdbT
                                  therealdb
                                  0
                                  3
                                  64

                                • Possible feature request?
                                  therealdbT
                                  therealdb
                                  0
                                  5
                                  169
                                Powered by NodeBB | Contributors
                                Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                • Login

                                • Don't have an account? Register

                                • Login or register to search.
                                • First post
                                  Last post
                                0
                                • Categories
                                • Recent
                                • Tags
                                • Popular
                                • Unsolved