CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Upgrade Issues
T
Topic thumbnail image
Multi-System Reactor
[SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
G
Topic thumbnail image
Multi-System Reactor
[SOLVED] Question regarding "in" vs "contains" vs contents of the string
G
Topic thumbnail image
Multi-System Reactor
Logon screen timeout
G
Noticing since 170 that the lock screen doesn't switch to the logon prompt but, rather, stays on the active UI until such time as you go to click something within it. Then it jumps to the login screen. Brave browser Brave 1.92.139 (Official Build) (arm64) Chromium: 150.0.7871.114
Multi-System Reactor
[MSR] Copy&past of actions and/or drag&drop between set/reset
therealdbT
Hey @toggledbits One thing that bothers me while doing work on new systems/new features, is that I cannot copy&paste actions, and I cannot drag&drop between set and resets. #1 is for when I want to copy an action between different rules opened in two separate browser windows, while #2 is when I just need to flip a bunch of actions in the reset, or move some logic back and forth. Both will be appreciated, but I understand the technical challenges. Thanks!
Multi-System Reactor
Upgrade advice - upgrade from aarch64 to ARM64 image
T
I'm currently on version 26011. I understand that the aarch64 image is no longer supported. So, I therefore need to update to the ARM64 image. Can anyone possibly suggest how I update my docker compose.yaml file (see below). Ideally I'd like to keep my existing reactions etc. rather than start from scratch. # Multi-System Reactor template docker-compose.yml (version 22160) # # Change the lines indicated by "DO"... # services: reactor: container_name: reactor environment: # DO change the TZ: line to set your local time zone. # See valid TZ list: https://en.wikipedia.org/wiki/List_of_tz_database_time_zones TZ: GB # # DO NOT change this path. Your directory location is in "source" below. REACTOR_DATA_PREFIX: /var/reactor # DO change the image below to the one you are using (e.g. armv7l or aarch64 for RPi 4) image: toggledbits/reactor:latest-aarch64 restart: "always" expose: - 8111 ports: - 8111:8111 volumes: # DO change the /home/username/reactor below to the directory you created for # your local data; DO NOT change the /var/reactor part - /home/pi/docker/reactor:/var/reactor - /etc/localtime:/etc/localtime:ro tmpfs: /tmp
Multi-System Reactor
Alexa for MSR, any interest?
MikeReadingtonM
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Telegram notification broke with latest update
3
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Phantom device, “INFO” appears
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] Mode Status NULL
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[RESOLVED] HTTP query failing after version 26177
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Question about the find function
wmarcolinW
Topic thumbnail image
Multi-System Reactor
[Answered] OK to remove old json files?
3
Topic thumbnail image
Multi-System Reactor
Deprecation Announcement: 32-bit ARM *docker* images
toggledbitsT
If you are using the armv7l docker image, the OpenJS Foundation that publishes node is no longer producing 32-bit builds as of v24. That means the last supported LTS version of node for armv7l is v22, which will go End-of-Life in May 2027. Therefore, the Reactor armv7l image is now deprecated and will only be produced until node v22 goes EOL, and I will not publish armv7l images beyond that date. If you are running an RPi 3 or earlier with Reactor, you are on this image, and will need to upgrade hardware to a 64-bit model and use the arm64 image. If you need help getting it done, ask in this category.
Multi-System Reactor
[Solved] build 26150 - engine not starting
G
@toggledbits I pulled the image (well, Watchtower did) and within minutes the whole system went offline. The log looks like it ends with 26143. [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-mkahsmgf/26qq82mw-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lqyfljfi/22f8on0t-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lsb61rw8/24oenqi2-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/rule-lrh58he0:S-1c00gfib-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/1c00dylr-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lrh58he0/1nam9w5u-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-miuh2qqi/22ls4lql-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-kwc6rmci/rule-kwc6rmci:S-1vj8sdfc-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-kwc6rmci/rule-kwc6rmci:S-1qanz01x-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/24lq19p6-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-mk0o8iox/23oy468y-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-miscg2h3/rule-miscg2h3:S-22gmbq1c-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-kxgrfjke/238p0old-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-m7ccsso5/re-m7ccsso5-1r0myjxa-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/19nl9wq2-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/rule-ladyja6a:S-yl3xk9t-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ladyja6a/rule-ladyja6a:S-yl3vv5m-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-ln7j2nqp/re-ln7j2nqp-22mx9lzd-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-ln7j2nqp/22mx87c8-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-licneppy/1mzwe7ht-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-ml3194ih/25jqt1j4-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-kxgrg7kf/227hshak-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-reactorexmachina/13ua1p95-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-reactorexmachina/13uagam7-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-grpvl9oypg/rule-grpvl9oypg:R-134x4cbv-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-grpvl9oypg/rule-grpvl9oypg:R-134x2fyl-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#re-lscjrws1/238p5c22-cons [latest-26143]2026-05-31T15:23:44.547Z <default:INFO> Closing container Container#Predicate#rule-lbwr0jvq/1xkczf03-cons [latest-26143]2026-05-31T15:23:44.547Z <Structure:NOTICE> Structure Structure#1 stopped [latest-26143]2026-05-31T15:23:44.547Z <app:NOTICE> Closing APIs... [latest-26143]2026-05-31T15:23:44.547Z <wsapi:NOTICE> wsapi: closing... [latest-26143]2026-05-31T15:23:44.547Z <wsapi:NOTICE> wsapi: disconnecting from "192.168.1.23#82" (1001 service closing) [latest-26143]2026-05-31T15:23:44.548Z <httpapi:NOTICE> HTTP API closing... [latest-26143]2026-05-31T15:23:44.549Z <wsapi:NOTICE> wsapi: server closed [latest-26143]2026-05-31T15:23:44.549Z <httpapi:INFO> HTTP server closed. [latest-26143]2026-05-31T15:23:44.549Z <app:NOTICE> Stopping timers... [latest-26143]2026-05-31T15:23:44.551Z <app:null> Shutdown complete, process ID 1 [latest-26143]2026-05-31T15:23:44.551Z <app:null> Closing logs... [latest-26143]2026-05-31T15:23:44.551Z <default:null> Closing log I can SSH to the VM. Alas, I do not have the previous image for 26143 as I'm a little too quick sometimes on housekeeping.
Multi-System Reactor
http request action & digest auth
tunnusT
I’m using the HTTP Request action in MSR and need to authenticate against an endpoint that uses HTTP Digest authentication. Now that endpoint was changed to use SHA-256 in digest auth, so I would like to know if MSR supports it, or is it limited to MD5-based digest auth?
Multi-System Reactor

Set reaction triggering wrong z-wave device

Scheduled Pinned Locked Moved Multi-System Reactor
19 Posts 2 Posters 2.0k Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • T tamorgen

    Good afternoon,
    I've been having an issue where a rule that is supposed to trigger my front porch lights when motion is detected, is instead turning on our holiday soffit lighting. They are one z-wave entry appart. It's been driving me crazy trying to figure out what is triggering the lights to come on, because I haven't been able to find any rule that would trigger it, and the logs don't indicate any mention of that specific entity being turned on.

    The device that it's turning on is:

    Soffit Outlets
    zwavejs>136-0
    false
    6:48:32 PM

    The device that it should be turning on is:

    Front Porch Lights
    zwavejs>137-0
    false
    6:47:09 PM

    7586a793-96cd-40ee-84be-5fb07d0d7eb7-image.png

    I've switched the entry to use the HAAS entry to stop it, but I'd like to know why it's triggering an entry one entity off.

    This could also explain some issues I've been having with Zwave entries not working properly for some time.

    I'm running Reactor (Multi-hub) latest-26011-c621bbc7 in Docker/Portainer.
    ZWaveJSController [0.1.25139]

    T Offline
    T Offline
    tamorgen
    wrote on last edited by tamorgen
    #3

    Yes, it's no theory. I was able to confirm it by activating the action to turn on the zwave-137-0, and zwave-136-0 came on, and 137-0 did not. Once I determined that was happening, I found events for zwave-137-0 in the logs at the time it was zwave-136-0 was coming on.

    Edit: I could not find events for zwave-136-0 coming on, so that initially left me stumped.

    0d215b38-2941-475d-88f0-5c9d2f890a62-image.png

    1 Reply Last reply
    0
    • T Offline
      T Offline
      tamorgen
      wrote on last edited by tamorgen
      #4

      Here's a better output of the logs. I was providing output from Proxmox, which is awful for copying text.

      root@docker:/home/tmorgenthaler/reactor/logs# cat reactor.* | grep 137-0 | grep zwavejs | grep T22:29
      [latest-26011]2026-01-30T22:29:00.005Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs performing power_switch.on on Front Porch Lights (Switch#zwavejs>137-0) with {  }
      [latest-26011]2026-01-30T22:29:00.918Z <ZWaveJSController:5:ZWaveJSController.js:966> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
      [latest-26011]2026-01-30T22:29:01.169Z <ZWaveJSController:5:ZWaveJSController.js:966> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
      [latest-26011]2026-01-30T22:29:02.240Z <ZWaveJSController:5:ZWaveJSController.js:966> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
      [latest-26011]2026-01-30T22:29:02.241Z <ZWaveJSController:5:ZWaveJSController.js:966> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
      [latest-26011]2026-01-30T22:29:02.241Z <ZWaveJSController:5:ZWaveJSController.js:966> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
      [latest-26011]2026-01-30T22:29:02.241Z <ZWaveJSController:5:ZWaveJSController.js:1270> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to true
      [latest-26011]2026-01-30T22:29:02.241Z <ZWaveJSController:5:ZWaveJSController.js:1255> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
      [latest-26011]2026-01-30T22:29:02.242Z <ZWaveJSController:5:ZWaveJSController.js:1166> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
      [latest-26011]2026-01-30T22:29:02.242Z <ZWaveJSController:5:ZWaveJSController.js:1179> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value" }, "value": true, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
      [latest-26011]2026-01-30T22:29:02.242Z <ZWaveJSController:5:ZWaveJSController.js:1270> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to true
      [latest-26011]2026-01-30T22:29:02.491Z <ZWaveJSController:5:ZWaveJSController.js:966> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
      root@docker:/home/tmorgenthaler/reactor/logs# cat reactor.* | grep 136-0 | grep zwavejs | grep T22:29
      root@docker:/home/tmorgenthaler/reactor/logs# 
      

      This was the timestamp for when that particular rule was triggering. As you can see, the 137-0 entity has several entries for that timestamp, but 136-0 does not, yet I've been able to replicate that is what is occuring.

      1 Reply Last reply
      0
      • toggledbitsT Offline
        toggledbitsT Offline
        toggledbits
        wrote on last edited by
        #5

        Please go to the Entities list, find entity zwavejs>137-0, open its detail panel, and copy-paste the output from the Copy Attributes button here (as text, no screen shots).

        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

        T 1 Reply Last reply
        0
        • toggledbitsT toggledbits

          Please go to the Entities list, find entity zwavejs>137-0, open its detail panel, and copy-paste the output from the Copy Attributes button here (as text, no screen shots).

          T Offline
          T Offline
          tamorgen
          wrote on last edited by tamorgen
          #6

          @toggledbits said in Set reaction triggering wrong z-wave device:

          Please go to the Entities list, find entity zwavejs>137-0, open its detail panel, and copy-paste the output from the Copy Attributes button here (as text, no screen shots).

          I've providing a link as text file. I got a warning about the number of characters when I tried to paste into the reply directly.

          137-0 attributes

          1 Reply Last reply
          0
          • T Offline
            T Offline
            tamorgen
            wrote on last edited by
            #7

            I should also note that I compared/verified in HAAS/Zwave-JS the entity numbers are correct and correspond with what is in MSR.

            1 Reply Last reply
            0
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by toggledbits
              #8

              OK. Everything checks out there. I would upgrade to the latest ZWaveJSController -- it looks like you are a release behind. That version added logging for what is actually sent to ZWaveJS, which may be instructive. But restarting for that update and rebuilding the state data may resolve the issue (you've probably done the former, I assume, but the latter is less obvious), so we're changing the conditions of the test. But let's see what happens when you upgrade, and then see what the log entries look like if the behavior is the same, because it sure looks like ZWaveJSController has it correct.

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              0
              • T Offline
                T Offline
                tamorgen
                wrote on last edited by
                #9

                I wasn't sure if I was on the correct release or not. Does the Docker image include the Zwave release in the pull?

                T 1 Reply Last reply
                0
                • T tamorgen

                  I wasn't sure if I was on the correct release or not. Does the Docker image include the Zwave release in the pull?

                  T Offline
                  T Offline
                  tamorgen
                  wrote on last edited by
                  #10

                  said in Set reaction triggering wrong z-wave device:

                  I wasn't sure if I was on the correct release or not. Does the Docker image include the Zwave release in the pull?

                  Never mind. It's says it does not in your documentation. 😃

                  I updated to v25304 and restarted Reactor. I'll run some tests now.

                  T 1 Reply Last reply
                  0
                  • T tamorgen

                    said in Set reaction triggering wrong z-wave device:

                    I wasn't sure if I was on the correct release or not. Does the Docker image include the Zwave release in the pull?

                    Never mind. It's says it does not in your documentation. 😃

                    I updated to v25304 and restarted Reactor. I'll run some tests now.

                    T Offline
                    T Offline
                    tamorgen
                    wrote on last edited by tamorgen
                    #11

                    said in Set reaction triggering wrong z-wave device:

                    I updated to v25304 and restarted Reactor. I'll run some tests now.

                    Alright, it still seems to be doing the same thing. I'm tailing the zwavejs log, and pressing the button for the Set Reaction. I see it pushing the command for 137-0, however, the soffit lights (136-0) are coming on.

                    root@docker:/home/tmorgenthaler/reactor/logs# tail -f zwavejs.log | grep 137-0
                    [latest-26011]2026-01-31T20:25:01.008Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                    [latest-26011]2026-01-31T20:25:01.008Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                    [latest-26011]2026-01-31T20:25:01.008Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": true, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                    [latest-26011]2026-01-31T20:25:01.009Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to true
                    [latest-26011]2026-01-31T20:25:01.104Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:15.710Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs performing power_switch.on on Front Porch Lights (Switch#zwavejs>137-0) with {  }
                    [latest-26011]2026-01-31T20:25:15.973Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:16.125Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:16.125Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to true
                    [latest-26011]2026-01-31T20:25:16.125Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:16.126Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                    [latest-26011]2026-01-31T20:25:16.126Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                    [latest-26011]2026-01-31T20:25:16.126Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": true, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                    [latest-26011]2026-01-31T20:25:16.126Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to true
                    [latest-26011]2026-01-31T20:25:16.224Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:33.510Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:33.661Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:33.661Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                    [latest-26011]2026-01-31T20:25:33.662Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to false
                    [latest-26011]2026-01-31T20:25:33.666Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                    [latest-26011]2026-01-31T20:25:33.666Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                    [latest-26011]2026-01-31T20:25:33.666Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": false, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                    [latest-26011]2026-01-31T20:25:33.666Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to false
                    [latest-26011]2026-01-31T20:25:33.760Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                    

                    I also see the results of turning off the device from HAAS in the ZWaveJS logs.

                    Here are the entries for the devices in HAAS from ZwaveJS-UI

                    0ddf698e-d6f1-41fd-867b-4c687476b02e-Screenshot 2026-01-31 at 3.29.10 PM.png Screenshot 2026-01-31 at 3.29.10 PM

                    I've also creating an attirbutes text file for 136-0. Maybe something is funky in that entry.

                    136-0 attributes

                    1 Reply Last reply
                    0
                    • T Offline
                      T Offline
                      tamorgen
                      wrote on last edited by tamorgen
                      #12

                      Here are some logs of me turning the entities on and off from HAAS.

                      root@docker:/home/tmorgenthaler/reactor/logs# tail -f zwavejs.log | grep 13'[6-7]'-0
                      [latest-26011]2026-01-31T20:37:00.403Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>136-0 power_switch.state
                      [latest-26011]2026-01-31T20:37:00.403Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>136-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": true, "__endp": { "power_switch.state": { "entity": "136-0", "impl": { "valueId": "37:currentValue:" } } } }
                      [latest-26011]2026-01-31T20:37:00.403Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>136-0.x_zwave_values.Binary_Switch_currentValue to true
                      [latest-26011]2026-01-31T20:37:00.648Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>136-0
                      [latest-26011]2026-01-31T20:37:18.529Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>136-0
                      [latest-26011]2026-01-31T20:37:18.553Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>136-0
                      [latest-26011]2026-01-31T20:37:18.553Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>136-0.x_zwave_values.Binary_Switch_targetValue to false
                      [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>136-0
                      [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "136-0", "impl": { "valueId": "37:currentValue:" } }
                      [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>136-0 power_switch.state
                      [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>136-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": false, "__endp": { "power_switch.state": { "entity": "136-0", "impl": { "valueId": "37:currentValue:" } } } }
                      [latest-26011]2026-01-31T20:37:18.560Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>136-0.x_zwave_values.Binary_Switch_currentValue to false
                      [latest-26011]2026-01-31T20:37:18.779Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>136-0
                      [latest-26011]2026-01-31T20:37:25.647Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:25.803Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:25.803Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:25.804Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to true
                      [latest-26011]2026-01-31T20:37:25.808Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                      [latest-26011]2026-01-31T20:37:25.808Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                      [latest-26011]2026-01-31T20:37:25.808Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": true, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                      [latest-26011]2026-01-31T20:37:25.809Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to true
                      [latest-26011]2026-01-31T20:37:25.898Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:29.297Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:29.447Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:29.448Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                      [latest-26011]2026-01-31T20:37:29.448Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to false
                      [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                      [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                      [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": false, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                      [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to false
                      [latest-26011]2026-01-31T20:37:29.547Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                      
                      toggledbitsT 1 Reply Last reply
                      0
                      • T Offline
                        T Offline
                        tamorgen
                        wrote on last edited by
                        #13

                        I also just noticed that if I performed an action from the Entities page in MSR fr 137-0, it's turning on 136-0 in HAAS. If I turn on 136-0 through entities, it's turning on 137-0 in HAAS. It would appear these devices are somehow switching actions, despite everything showing what they are.

                        1 Reply Last reply
                        0
                        • T tamorgen

                          Here are some logs of me turning the entities on and off from HAAS.

                          root@docker:/home/tmorgenthaler/reactor/logs# tail -f zwavejs.log | grep 13'[6-7]'-0
                          [latest-26011]2026-01-31T20:37:00.403Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>136-0 power_switch.state
                          [latest-26011]2026-01-31T20:37:00.403Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>136-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": true, "__endp": { "power_switch.state": { "entity": "136-0", "impl": { "valueId": "37:currentValue:" } } } }
                          [latest-26011]2026-01-31T20:37:00.403Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>136-0.x_zwave_values.Binary_Switch_currentValue to true
                          [latest-26011]2026-01-31T20:37:00.648Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>136-0
                          [latest-26011]2026-01-31T20:37:18.529Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>136-0
                          [latest-26011]2026-01-31T20:37:18.553Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>136-0
                          [latest-26011]2026-01-31T20:37:18.553Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>136-0.x_zwave_values.Binary_Switch_targetValue to false
                          [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>136-0
                          [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "136-0", "impl": { "valueId": "37:currentValue:" } }
                          [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>136-0 power_switch.state
                          [latest-26011]2026-01-31T20:37:18.559Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>136-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": false, "__endp": { "power_switch.state": { "entity": "136-0", "impl": { "valueId": "37:currentValue:" } } } }
                          [latest-26011]2026-01-31T20:37:18.560Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>136-0.x_zwave_values.Binary_Switch_currentValue to false
                          [latest-26011]2026-01-31T20:37:18.779Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>136-0
                          [latest-26011]2026-01-31T20:37:25.647Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:25.803Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:25.803Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:25.804Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to true
                          [latest-26011]2026-01-31T20:37:25.808Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                          [latest-26011]2026-01-31T20:37:25.808Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                          [latest-26011]2026-01-31T20:37:25.808Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": true, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                          [latest-26011]2026-01-31T20:37:25.809Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to true
                          [latest-26011]2026-01-31T20:37:25.898Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:29.297Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:29.447Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:29.448Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event value updated entity Switch#zwavejs>137-0
                          [latest-26011]2026-01-31T20:37:29.448Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_targetValue to false
                          [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1237> ZWaveJSController#zwavejs updating attribute power_switch.state with { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } }
                          [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1148> ZWaveJSController#zwavejs _apply_value entity Switch#zwavejs>137-0 power_switch.state
                          [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1161> ZWaveJSController#zwavejs handling Switch#zwavejs>137-0 power_switch.state by { "valueId": "37:currentValue:" } with { "endpoint": 0, "commandClass": 37, "commandClassName": "Binary Switch", "property": "currentValue", "propertyName": "currentValue", "ccVersion": 2, "metadata": { "type": "boolean", "readable": true, "writeable": false, "label": "Current value", "stateful": true, "secret": false }, "value": false, "__endp": { "power_switch.state": { "entity": "137-0", "impl": { "valueId": "37:currentValue:" } } } }
                          [latest-26011]2026-01-31T20:37:29.453Z <ZWaveJSController:5:ZWaveJSController.js:1252> ZWaveJSController#zwavejs setting Switch#zwavejs>137-0.x_zwave_values.Binary_Switch_currentValue to false
                          [latest-26011]2026-01-31T20:37:29.547Z <ZWaveJSController:5:ZWaveJSController.js:948> ZWaveJSController#zwavejs handling node event statistics updated entity Switch#zwavejs>137-0
                          
                          toggledbitsT Offline
                          toggledbitsT Offline
                          toggledbits
                          wrote on last edited by toggledbits
                          #14

                          @tamorgen said in Set reaction triggering wrong z-wave device:

                          Here are some logs of me turning the entities on and off from HAAS.

                          You've shown here all stuff from ZWaveController, not HassController...? I don't think that would be helpful here anyway, because it would only show the HA entity IDs, and HA doesn't embed ZWave node numbers in their entity names. You would have to go look at the device in HA to confirm the node numbers. In HA's UI, go to Settings > Integrations > ZWave > Devices. Find the device you think is your Front Porch Lights switch, and click it. In the Device Info area, there's a Z-Wave Info heading with an arrow — click the arrow to expose the node number.

                          You said you updated ZWaveJSController, but it's still not showing me the expected log data. Can you confirm that in the startup messages for Reactor, ZWaveJSController reports it is version as 25304. If not, your update was not successful.

                          You can also go back to the ZWave-jS UI and command node 137 on from there, and see which device ZWave-JS switches. If it's the same device that Reactor switches, your Z-Wave nodes or HA devices are incorrectly identified.

                          What is clear in the Reactor logs so far is that ZWave node 137 is being told to do something, and ZWave node 137 responds back that it received the command its values changed. Nowhere along the way do the logs mention 136. If there was something wrong with what ZWaveJSController was commanding ZWaveJS to do, I would expect it log that it was performing an action on 137, but then gets update reports from 136, and that's not what is happening. I can also see in your Z-Wave data that node 137 is named "Front Porch Lights" at the node itself, which is consistent with the Reactor entity name, so Reactor/ZWaveJSController thinks it is doing the right thing.

                          I would start looking at the root, which is the ZWaveJS-UI, and make sure that node 137 is really your porch lights and you can command them on and off from there. If that's not the case, change the device name in Z-WaveJS UI, and then make sure the names in both HA and Reactor for nodes 136 and 137 match that data. Right now, it appears they do not.

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          T 1 Reply Last reply
                          0
                          • toggledbitsT toggledbits

                            @tamorgen said in Set reaction triggering wrong z-wave device:

                            Here are some logs of me turning the entities on and off from HAAS.

                            You've shown here all stuff from ZWaveController, not HassController...? I don't think that would be helpful here anyway, because it would only show the HA entity IDs, and HA doesn't embed ZWave node numbers in their entity names. You would have to go look at the device in HA to confirm the node numbers. In HA's UI, go to Settings > Integrations > ZWave > Devices. Find the device you think is your Front Porch Lights switch, and click it. In the Device Info area, there's a Z-Wave Info heading with an arrow — click the arrow to expose the node number.

                            You said you updated ZWaveJSController, but it's still not showing me the expected log data. Can you confirm that in the startup messages for Reactor, ZWaveJSController reports it is version as 25304. If not, your update was not successful.

                            You can also go back to the ZWave-jS UI and command node 137 on from there, and see which device ZWave-JS switches. If it's the same device that Reactor switches, your Z-Wave nodes or HA devices are incorrectly identified.

                            What is clear in the Reactor logs so far is that ZWave node 137 is being told to do something, and ZWave node 137 responds back that it received the command its values changed. Nowhere along the way do the logs mention 136. If there was something wrong with what ZWaveJSController was commanding ZWaveJS to do, I would expect it log that it was performing an action on 137, but then gets update reports from 136, and that's not what is happening. I can also see in your Z-Wave data that node 137 is named "Front Porch Lights" at the node itself, which is consistent with the Reactor entity name, so Reactor/ZWaveJSController thinks it is doing the right thing.

                            I would start looking at the root, which is the ZWaveJS-UI, and make sure that node 137 is really your porch lights and you can command them on and off from there. If that's not the case, change the device name in Z-WaveJS UI, and then make sure the names in both HA and Reactor for nodes 136 and 137 match that data. Right now, it appears they do not.

                            T Offline
                            T Offline
                            tamorgen
                            wrote on last edited by tamorgen
                            #15

                            @toggledbits said in Set reaction triggering wrong z-wave device:

                            . Can you confirm that in the startup messages for Reactor, ZWaveJSController reports it is version as 25304

                            Yes, it shows up as 0.1.25304

                            472fe4fb-680e-4559-9dea-659c4d7dbc52-image.png

                            So, you seemed to have hit it. There is a disagreement in the names in the Z-wave JS integration and the Z-Wave JS UI naming. I'm not sure how or when that happened, since I haven't touched the naming of these in at least 2 years.

                            b0f5045e-4afe-47d8-8354-64b43b0b8c98-image.png

                            2858fd9d-60be-47d3-9993-0e22f8a0b369-image.png

                            The device that is 136 is truly the Front Porch Sconces. Everywhere in the HA dashboards when I click on the binary switch, it does turn it on. Same with 137 being the Soffit Lights.

                            It would seem it's getting the names from the ZwaveJS UI values, since they seemed to be off. I've gone ahead and renamed them in ZwaveJS UI to reflect the values in ZwaveJS. How do I get ZWaveJSController to update the names? They still show up as the incorrect name. I went ahead and restarted MSR, and the old naming is till persistent.

                            5aaa0307-a69a-4fb2-b0ec-ee47e789f476-image.png

                            ad2f69ee-5402-4676-8bf8-2241d0bb9723-image.png 2c128df2-2833-4def-9af5-bcdb1463b13b-image.png

                            1 Reply Last reply
                            0
                            • toggledbitsT Offline
                              toggledbitsT Offline
                              toggledbits
                              wrote on last edited by
                              #16

                              Reactor only changes the entity name when the entity is first created. From there on, it sticks, no matter what the underlying hub does. To change the name, hit the "Rename" button on the entity in the detail pane (see your latest screen shots).

                              Also future note. When posting log snippets, please don't use grep or other filtering. Find the lines of interest, and post 20-25 of context before and as much context after as is relevant. Not all relevant log messages may contain the string you are searching for.

                              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                              T 1 Reply Last reply
                              0
                              • toggledbitsT toggledbits

                                Reactor only changes the entity name when the entity is first created. From there on, it sticks, no matter what the underlying hub does. To change the name, hit the "Rename" button on the entity in the detail pane (see your latest screen shots).

                                Also future note. When posting log snippets, please don't use grep or other filtering. Find the lines of interest, and post 20-25 of context before and as much context after as is relevant. Not all relevant log messages may contain the string you are searching for.

                                T Offline
                                T Offline
                                tamorgen
                                wrote on last edited by
                                #17

                                @toggledbits

                                Thank you. Perhaps the non-updating of the name was the root cause of my issue all along.

                                1 Reply Last reply
                                0
                                • toggledbitsT Offline
                                  toggledbitsT Offline
                                  toggledbits
                                  wrote on last edited by
                                  #18

                                  The name is incorrect at ZWave-JS (on the node itself) if that's the case, so to keep your sanity later, make sure you go all the way back to the source and work your way forward from there.

                                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                  T 1 Reply Last reply
                                  0
                                  • toggledbitsT toggledbits

                                    The name is incorrect at ZWave-JS (on the node itself) if that's the case, so to keep your sanity later, make sure you go all the way back to the source and work your way forward from there.

                                    T Offline
                                    T Offline
                                    tamorgen
                                    wrote on last edited by
                                    #19

                                    @toggledbits said in Set reaction triggering wrong z-wave device:

                                    The name is incorrect at ZWave-JS (on the node itself) if that's the case, so to keep your sanity later, make sure you go all the way back to the source and work your way forward from there.

                                    I renamed the devices on the ZWave-JS UI, so i won't have the problem going forward. I'm still not sure how this all happened, as I did not experience this problem in years past. The only thing I can think of is there was some sort of glitch in an upgrade. I know I had to restore the Z-Wave JS UI to an earlier version back in October because of a change they made that broke window coverings, so perhaps during that restore something went wonky.

                                    1 Reply Last reply
                                    1
                                    Reply
                                    • Reply as topic
                                    Log in to reply
                                    • Oldest to Newest
                                    • Newest to Oldest
                                    • Most Votes


                                    Recent Topics

                                    • Arming Envisalink panel from MSR
                                      T
                                      tamorgen
                                      0
                                      7
                                      181

                                    • [Solved] DynamicGroupController updating members issue
                                      CrilleC
                                      Crille
                                      0
                                      5
                                      134

                                    • Reactor (Multi-System/Multi-Hub) Announcements
                                      toggledbitsT
                                      toggledbits
                                      5
                                      148
                                      130.3k

                                    • DynamicGroupController and attributes
                                      therealdbT
                                      therealdb
                                      1
                                      5
                                      125

                                    • Upgrade Issues
                                      T
                                      tbully
                                      0
                                      9
                                      244

                                    • [SOLVED] Conflicting Set Reaction Groups Appear to Fire Simultaneously in Single Rule Evaluation
                                      toggledbitsT
                                      toggledbits
                                      0
                                      10
                                      269

                                    • [SOLVED] Question regarding "in" vs "contains" vs contents of the string
                                      G
                                      gwp1
                                      0
                                      5
                                      146

                                    • openLuup console disappeared - 500 - Internal Server Error
                                      A
                                      a-lurker
                                      0
                                      2
                                      176

                                    • Logon screen timeout
                                      G
                                      gwp1
                                      0
                                      5
                                      199

                                    • [MSR] Copy&past of actions and/or drag&drop between set/reset
                                      toggledbitsT
                                      toggledbits
                                      0
                                      9
                                      377

                                    • Upgrade advice - upgrade from aarch64 to ARM64 image
                                      toggledbitsT
                                      toggledbits
                                      0
                                      4
                                      222
                                    Powered by NodeBB | Contributors
                                    Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                    • Login

                                    • Don't have an account? Register

                                    • Login or register to search.
                                    • First post
                                      Last post
                                    0
                                    • Categories
                                    • Recent
                                    • Tags
                                    • Popular
                                    • Unsolved