Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor

Build 21117

Scheduled Pinned Locked Moved Multi-System Reactor
19 Posts 3 Posters 752 Views 3 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • LibraSunL Offline
    LibraSunL Offline
    LibraSun
    wrote on last edited by LibraSun
    #8

    Yes and no. My only use case for Global Reactions has been rare times when I want to call the exact same routine from multiple other Rules, without it living inside yet another Rule. Good for compactness and ease of editing. Otherwise, I never use Global Reactions.

    EDIT: Just looked again. I have none! 🙂

    cw-kidC 1 Reply Last reply
    0
    • LibraSunL LibraSun

      Yes and no. My only use case for Global Reactions has been rare times when I want to call the exact same routine from multiple other Rules, without it living inside yet another Rule. Good for compactness and ease of editing. Otherwise, I never use Global Reactions.

      EDIT: Just looked again. I have none! 🙂

      cw-kidC Offline
      cw-kidC Offline
      cw-kid
      wrote on last edited by
      #9

      @librasun said in Build 21117:

      My only use case for Global Reactions has been rare times when I want to call the exact same routine from multiple other Rules, without it living inside yet another Rule

      That's true I didn't think of that use case.

      I have only been using Global Reactions like manually triggered Vera scenes, as I could send a http request in to MSR and have that Global Reaction run.

      However Global Reactions have limitations e.g. they have no contraints / conditions.

      1 Reply Last reply
      0
      • cw-kidC Offline
        cw-kidC Offline
        cw-kid
        wrote on last edited by cw-kid
        #10

        @LibraSun

        Do you have an example URL to set a Global Variable ?

        variable/:name/set - (PUT) set the global variable specified to a value (JSON data); the request body must be application/json type.

        How do you specify your value for the variable ?

        1 Reply Last reply
        0
        • cw-kidC Offline
          cw-kidC Offline
          cw-kid
          wrote on last edited by
          #11

          I just updated to this build I think:

          de4d662e-eeb8-40d4-a7f6-d0619b37bef6-image.png

          1 Reply Last reply
          0
          • cw-kidC Offline
            cw-kidC Offline
            cw-kid
            wrote on last edited by
            #12

            To me this reads like we won't be able to send a simple one line HTTP request to MSR to change a Global Variable to trigger a Rule Set:

            variable/:name/set - (PUT) set the global variable specified to a value (JSON data); the request body must be application/json type.
            

            Which if so, this probably isn't going to work for me.

            Its difficult enough already to have the Home Remote dashboard app send out a HTTP Request when a dashboard button is pressed.

            If I have to also contend with a request body and having to specify application/json type etc, I don't think I'll be able to do it,

            1 Reply Last reply
            0
            • cw-kidC Offline
              cw-kidC Offline
              cw-kid
              wrote on last edited by cw-kid
              #13

              I can't even seem to get Postman working as a test.

              Trying to set the Global Variable named "run" to a value of "3"

              41627505-29e2-43bd-a557-35e2abfa0273-image.png

              <pre>SyntaxError: Unexpected token 3 in JSON at position 0<br> &nbsp; &nbsp;at JSON.parse (&lt;anonymous&gt;)<br> &nbsp; &nbsp;at createStrictSyntaxError (/home/pi/Documents/reactor/node_modules/body-parser/lib/types/json.js:158:10)<br> &nbsp; &nbsp;at parse (/home/pi/Documents/reactor/node_modules/body-parser/lib/types/json.js:83:15)<br> &nbsp; &nbsp;at /home/pi/Documents/reactor/node_modules/body-parser/lib/read.js:121:18<br> &nbsp; &nbsp;at invokeCallback (/home/pi/Documents/reactor/node_modules/raw-body/index.js:224:16)<br> &nbsp; &nbsp;at done (/home/pi/Documents/reactor/node_modules/raw-body/index.js:213:7)<br> &nbsp; &nbsp;at IncomingMessage.onEnd (/home/pi/Documents/reactor/node_modules/raw-body/index.js:273:7)<br> &nbsp; &nbsp;at IncomingMessage.emit (events.js:314:20)<br> &nbsp; &nbsp;at IncomingMessage.EventEmitter.emit (domain.js:483:12)<br> &nbsp; &nbsp;at endReadableNT (_stream_readable.js:1241:12)</pre>
              
              toggledbitsT 1 Reply Last reply
              0
              • LibraSunL Offline
                LibraSunL Offline
                LibraSun
                wrote on last edited by
                #14

                @toggledbits to the rescue??

                FWIW, I'm on rev. 21117 and currently do not have any inbound HTTP calls in my workflow. Wish I could help you more!

                1 Reply Last reply
                0
                • LibraSunL Offline
                  LibraSunL Offline
                  LibraSun
                  wrote on last edited by
                  #15

                  Quick question for @toggledbits ...

                  Will having a Constraint Group in Reset Reaction -- all by itself, doing nothing, and with no other Actions defined in the R.R. -- cause the Rule to stop the Set Reaction mid-stream if the Rule goes unset? And if so, will that behavior manifest only when the R.R. Group is TRUE?

                  Or will MSR be agnostic towards orphaned/FALSE Constraint Groups in the R.R., allowing the S.R. to run to completion. I'm thinking that's how most users would expect things to go, but felt it prudent to inquire. Thanks!

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by
                    #16

                    Facts:

                    1. Reactor only looks at the number of actions on the reaction to determine if it is "runnable" as a counter-reaction.
                    2. Constraints are evaluated, which is to say, their states are determined, at the same time the triggers are evaluated, including constraints in action groups (so before either the SET or RESET reaction is run, the constraint states have already been determined).
                    3. Constraints are considered for logic purposes only at the time they are applicable: the rule constraint state is only considered if the rule is transitioning from reset to set and is preparing to run the SET reaction; reaction constraint states (regardless of location) are only considered at the moment the group is encountered during the reaction run.
                    4. When a reaction is stopped, all child reactions (i.e. groups, with or without constraints) are stopped as well. So if a set rule resets with a runnable RESET reaction, and there are still groups running from the SET reaction, the remaining SET reaction groups will be stopped together with the SET reaction itself.

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    1 Reply Last reply
                    1
                    • cw-kidC cw-kid

                      I can't even seem to get Postman working as a test.

                      Trying to set the Global Variable named "run" to a value of "3"

                      41627505-29e2-43bd-a557-35e2abfa0273-image.png

                      <pre>SyntaxError: Unexpected token 3 in JSON at position 0<br> &nbsp; &nbsp;at JSON.parse (&lt;anonymous&gt;)<br> &nbsp; &nbsp;at createStrictSyntaxError (/home/pi/Documents/reactor/node_modules/body-parser/lib/types/json.js:158:10)<br> &nbsp; &nbsp;at parse (/home/pi/Documents/reactor/node_modules/body-parser/lib/types/json.js:83:15)<br> &nbsp; &nbsp;at /home/pi/Documents/reactor/node_modules/body-parser/lib/read.js:121:18<br> &nbsp; &nbsp;at invokeCallback (/home/pi/Documents/reactor/node_modules/raw-body/index.js:224:16)<br> &nbsp; &nbsp;at done (/home/pi/Documents/reactor/node_modules/raw-body/index.js:213:7)<br> &nbsp; &nbsp;at IncomingMessage.onEnd (/home/pi/Documents/reactor/node_modules/raw-body/index.js:273:7)<br> &nbsp; &nbsp;at IncomingMessage.emit (events.js:314:20)<br> &nbsp; &nbsp;at IncomingMessage.EventEmitter.emit (domain.js:483:12)<br> &nbsp; &nbsp;at endReadableNT (_stream_readable.js:1241:12)</pre>
                      
                      toggledbitsT Offline
                      toggledbitsT Offline
                      toggledbits
                      wrote on last edited by
                      #17

                      @cw-kid said in Build 21117:

                      Trying to set the Global Variable named "run" to a value of "3"

                      Documentation fail. The PUT body needs to look like this:

                      {
                        "name": "<variablename>"
                        "value": <new value, any valid JSON type>
                      }
                      

                      The variable name given must match that in the URL.

                      I just added a GET for this as well just for simplicity/basic use only, to be in next build:

                      http://msr-ip:8111/api/v1/variable/testme/set?value=123

                      In this case, the value set will always be a string type, because that's what query parameter values are.

                      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                      cw-kidC 2 Replies Last reply
                      2
                      • toggledbitsT toggledbits

                        @cw-kid said in Build 21117:

                        Trying to set the Global Variable named "run" to a value of "3"

                        Documentation fail. The PUT body needs to look like this:

                        {
                          "name": "<variablename>"
                          "value": <new value, any valid JSON type>
                        }
                        

                        The variable name given must match that in the URL.

                        I just added a GET for this as well just for simplicity/basic use only, to be in next build:

                        http://msr-ip:8111/api/v1/variable/testme/set?value=123

                        In this case, the value set will always be a string type, because that's what query parameter values are.

                        cw-kidC Offline
                        cw-kidC Offline
                        cw-kid
                        wrote on last edited by
                        #18

                        @toggledbits said in Build 21117:

                        I just added a GET for this as well just for simplicity/basic use only, to be in next build:

                        Perfect thank you

                        1 Reply Last reply
                        0
                        • LibraSunL Offline
                          LibraSunL Offline
                          LibraSun
                          wrote on last edited by
                          #19

                          How will subsequent updates to the Docker image be managed after rev. 21117? I'm uncertain whether the Synology NAS > Docker > Registry approach to things means we no longer have to download new Image files and re-launch the Container. Would love to have an Auto-Update option somewhere in the mix.

                          1 Reply Last reply
                          0
                          Reply
                          • Reply as topic
                          Log in to reply
                          • Oldest to Newest
                          • Newest to Oldest
                          • Most Votes


                          Recent Topics

                          • Advice reqeusted to migrate MSR from Bare Metal to Container
                            T
                            tamorgen
                            0
                            5
                            44

                          • Reactor (Multi-System/Multi-Hub) Announcements
                            toggledbitsT
                            toggledbits
                            5
                            122
                            35.4k

                          • Z-Wave Future....
                            CatmanV2C
                            CatmanV2
                            0
                            5
                            132

                          • Can´t restart or upgrade/deploy MSR
                            toggledbitsT
                            toggledbits
                            0
                            4
                            87

                          • [Solved] Limit HA Entity in MSR
                            wmarcolinW
                            wmarcolin
                            0
                            7
                            191

                          • Disaster recovery and virtualisation
                            CatmanV2C
                            CatmanV2
                            0
                            5
                            662

                          • Remote access of Zwave stick from Z-wave server
                            CatmanV2C
                            CatmanV2
                            0
                            3
                            384

                          • Organizing/ structuring rule sets and rules
                            G
                            gwp1
                            0
                            5
                            374

                          • Moving MSR from a QNAP container to RP 5 - some issues
                            G
                            gwp1
                            0
                            5
                            346

                          • Widget deletion does not work and landing page (status) is empy
                            G
                            gwp1
                            0
                            4
                            340

                          • Need help reducing false positive notifications
                            T
                            tamorgen
                            0
                            7
                            520
                          Powered by NodeBB | Contributors
                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                          • Login

                          • Don't have an account? Register

                          • Login or register to search.
                          • First post
                            Last post
                          0
                          • Categories
                          • Recent
                          • Tags
                          • Popular
                          • Unsolved