toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Reactor Inspect - a small read-only helper panel for MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Reverse proxy & API ACL
tunnusT
I'm trying to allow anonymous access from a local network to /api/v1/log, but the problem now with the reverse proxy configuration is that this access is open via proxy to the internet. At least I wasn't able to configure ACL so that only an access from a local network would be permitted. reactor.yaml: baseurl: "http://192.168.1.12:8111" proxy_baseurl: "https://external.com:30000" trusted_proxy: "192.168.1.12" Local traffic would originate from 192.168.1.0/24 network. Synology is acting as a reverse proxy and hosting MSR as a docker container (which has its own network and IP 172.18.0.5). MSR build is latest-26298-fbb75fb8 users.yaml: - url: "/api/v1/log" method: "GET" source_ip: 172.18.0.0/24 allow: true Using the above ACL works, but it enables access via proxy also. If I use source_ip: 192.168.1.0/24, then it doesn't work either locally or remotely. So I'm kinda lost what should I use as source_ip in this case?
Multi-System Reactor
MFA
T
Topic thumbnail image
Multi-System Reactor
Grouped devices
G
I've seen many of you using Dynamic Group Controller. I'm using it myself for monitoring device battery levels. I've read and re-read the Dynamic Group Controller docs and still cannot come to an answer for my question so let me paint my scenario: I've migrated from EchoSpeaks in Hubitat ('cause borked and seemingly unmaintained) to Alexa Devices in Home Assistant ('cause not borked in 2026.11.0) to be able to send TTS to my Echo devices. In EchoSpeaks I could create groups. Sweet. In Alexa Devices I don't seem to be able to do so. As such, my thought was "wait - isn't there a way in MSR?" Is this an effective scenario that Dynamic Group Controller can be used for?
Multi-System Reactor
Login protections
tunnusT
Topic thumbnail image
Multi-System Reactor
Reactor Build 26284 stuck at Loading Reactor UI
T
Topic thumbnail image
Multi-System Reactor
MSR with reverse proxy
tunnusT
I'm trying to use MSR via reserve proxy in Synology DSM, but MSR page does not load https://<public ip>:30000/reactor/en-US/ At the same time logging page loads normally https://<public ip>:30000/api/v1/log I thought maybe authentication was messing it up, but there was no deny entries in the log, and also disabling authentication did not make any difference. For this use case VPN is not an option (that works, but as said not an option for this particular use case). Any ideas what could cause this? MSR build latest-26242-28d69aa8, Chrome browser
Multi-System Reactor
Missing attribute after upgrade
3
Topic thumbnail image
Multi-System Reactor
[MSR] Native fan capabilty
therealdbT
Nothing more to add. I see we have hvac_blower, but, anyway, maybe a native fan on the same assumptions of the fan from HASS could be reasonable. I have a couple of them. ie, this is from ESPHome via HASS. x_hass.domain="fan" x_hass.entity_id="fan.kitchen_seashell_hood_ventilation_fan" x_hass.floor_id=null x_hass.services=["fan","esphome"] x_hass.source="esphome" x_hass.state="off" x_hass_attr.friendly_name="Seashell Hood Ventilation Fan" x_hass_attr.percentage=50 x_hass_attr.percentage_step=25 x_hass_attr.preset_mode="" x_hass_attr.preset_modes=[] x_hass_attr.supported_features=49 Thanks.
Multi-System Reactor
[MSR] Rule do not fire
therealdbT
Topic thumbnail image
Multi-System Reactor
Rule condition shows TRUE in UI but Rule never transitions to SET — survives full restart
N
Build: latest-26221-b25bb3e3, Docker on Synology. Hi, I have a Rule whose Trigger/Constraints reference other Rules via Rule State ... is TRUE. At some point it stops firing. Expanding the rule's condition tree in the UI shows every Trigger and Constraint condition green/TRUE — confirmed live by walking into the room and watching Motion go true in real time. Rule History shows no new SET, just old reset entries. Tried, on the same rule, same evening: recreating the trigger conditions with fresh IDs, recreating the constraint conditions with fresh IDs (flat and wrapped in a new Group — wrapping in a Group produced one SET, but it didn't reproduce on repeat attempts with the same structure), and finally a full container restart with a verified-correct saved rule. Still no SET, even with a fresh live motion event right after the restart. Separately, I found that this rule (and its 10 per-room clones) share identical internal condition/group IDs with each other — leftover from a batch clone done months ago, never regenerated. Not sure if that's related, since fixing the IDs didn't reliably fix the symptom either. Has anyone seen a Rule State condition show TRUE in the UI without the Rule ever producing a SET, surviving a clean restart? Thanks in advance
Multi-System Reactor
DynamicGroupController and attributes
therealdbT
Hey @toggledbits I'm back to trying to optimize a couple of things based on dynamic group. First of all, I think I found a typo in the doc: primary_attribute: "binary_sensor.state" primary_attribute_value: | d = false; each id in members: d = getEntity(id)?.attributes?.power_switch?.state or d, d I think the correct code snippet is d = false, All that said, my use case for dynamic groups is to group 3 different climate devices, so I could easily command them at the same time. Commands are good, but sometimes I want to check if any of the devices are on, and that's easily done with a similar snippet as the one you have in the docs. But this is limited to the primary attribute, while I want to have any of the attributes in the group to be driven by a similar logic (while all are null in the group). ie, access hvac_control.mode and see if any of the unit is set to cool, or heat. Is that possible, without re-defining an expression in each of my rules? Thanks!
Multi-System Reactor
Unofficial thread for compatibility
tunnusT
As there are statements about compatibility for home assistant versions in MSR new version announcements (e.g. "HassController: Bless Hass to 2025.7.3"), I thought it would be good idea to track other controllers as well. As an example, I can confirm that build "latest-25208-c53e8513" works with Hubitat Elevation C-8 platform version 2.4.2.134 using Maker API. Updates: (the latest versions first in the list) OK: build "latest-25264-2fbe9217" with Hubitat C-8 platform v. 2.4.3.123
Multi-System Reactor
Ooops - Deleted Reactor Ex Machina II
R
I accidentally deleted Reactor Ex Machina II (REM II) from my Reactor rules. I tried to recover it by deleting the .json and .dval in the Rules subdirectory and then recreating it from Togglebits original posting, but that did not work. Does anyone know how to recover REM ll ?
Multi-System Reactor
Bail out of failed reaction?
T
Topic thumbnail image
Multi-System Reactor
Arming Envisalink panel from MSR
T
Topic thumbnail image
Multi-System Reactor
[Solved] DynamicGroupController updating members issue
CrilleC
Edit: Solved in latest-26221. Bare-metal latest-26193 I have this group: "OKforLarm": name: OK för Larm select: - include_controller: vera - include_capability: door_sensor filter_expression: entity.attributes.door_sensor.state It contains the entities I expect but behaves a bit odd. When I open vera>device_10097 the entity attribute door_sensor.state changes to true but it won't show up as member in the group, when I also open vera>device_10095 they both shows as members and when I close vera>device_10095 it disappear from the group but when I close vera>device_10097 it lingers in the group until I restart Reactor.
Multi-System Reactor
Upgrade Issues
T
Topic thumbnail image
Multi-System Reactor

Ezlo device capabilities

Scheduled Pinned Locked Moved Multi-System Reactor
31 Posts 3 Posters 9.8k Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • ElcidE Offline
    ElcidE Offline
    Elcid
    wrote on last edited by
    #10

    Capturing the learnt rf/ir codes would be enough, it would remove the need to fire up the ezlo/vera App to capture codes. Maybe actions to learn_ir/rf_code and an ezlo broadcast listener in the tool section?

    toggledbitsT 1 Reply Last reply
    0
    • ElcidE Elcid

      Capturing the learnt rf/ir codes would be enough, it would remove the need to fire up the ezlo/vera App to capture codes. Maybe actions to learn_ir/rf_code and an ezlo broadcast listener in the tool section?

      toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by
      #11

      @elcid said in Ezlo device capabilities:

      Capturing the learnt rf/ir codes would be enough,

      Yup, that's the part I can't do correctly without connecting data.

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      1 Reply Last reply
      0
      • ElcidE Offline
        ElcidE Offline
        Elcid
        wrote on last edited by
        #12

        Ok we will see what Oleh has to say.
        here is complete broadcast respnonse
        1 send "learn_ir_code" _id with hub.item.value.set
        2 after broadlink learns ir code.
        3 when learn_ir_code resets to 0

        3-
          {
            "date": 1626635249558,
            "data": {
              "id": "ui_broadcast",
              "msg_id": "60f47bf1122335125b847819",
              "msg_subclass": "hub.item.updated",
              "result": {
                "_id": "6059aab5122335123a08b974",
                "deviceCategory": "ir_tx",
                "deviceId": "6059aab5122335123a08b973",
                "deviceName": "RM pro lounge",
                "deviceSubcategory": "irt",
                "name": "learn_ir_code",
                "notifications": [],
                "roomName": "lounge",
                "serviceNotification": true,
                "syncNotification": false,
                "userNotification": false,
                "value": 0,
                "valueFormatted": "0",
                "valueType": "int"
              }
            }
          }
        
        2-
          {
            "date": 1626635249517,
            "data": {
              "id": "ui_broadcast",
              "msg_id": "60f47bf1122335125b847818",
              "msg_subclass": "hub.extensions.plugin.ui_broadcast",
              "result": {
                "code": "JgBQAAABLJUVERQSFBEUEhQSFBEUNxQSFDcUNxM3FDcUNxQ3FBITNxQ3FBIUNxMSFBIUEhQRFBIUEhQ3ExIUNxQ3FDcUNxM3FAAFLQABLUkUAA0FAAAAAAAAAAA=",
                "plugin": "broadlink",
                "type": "IR"
              }
            }
          }
        
        1-
          {
            "date": 1626635244363,
            "data": {
              "id": "ui_broadcast",
              "msg_id": "60f47bec122335125b847817",
              "msg_subclass": "hub.item.updated",
              "result": {
                "_id": "6059aab5122335123a08b974",
                "deviceCategory": "ir_tx",
                "deviceId": "6059aab5122335123a08b973",
                "deviceName": "RM pro lounge",
                "deviceSubcategory": "irt",
                "name": "learn_ir_code",
                "notifications": [],
                "roomName": "lounge",
                "serviceNotification": true,
                "syncNotification": false,
                "userNotification": false,
                "value": 1,
                "valueFormatted": "1",
                "valueType": "int"
              }
            }
          }
        
        
        1 Reply Last reply
        0
        • toggledbitsT Offline
          toggledbitsT Offline
          toggledbits
          wrote on last edited by
          #13

          This is not the broadcast response we need, though. This is the one that resets the item back to 0 when the learn stops. A successful learn causes two broadcasts: this one to announce that the device has stopped learning, and a separate one to announce what was learned. It's that second broadcast that is missing the IDs we would need to tie it back to either the item or the device.

          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

          1 Reply Last reply
          0
          • ElcidE Offline
            ElcidE Offline
            Elcid
            wrote on last edited by
            #14

            Yes i understand that, I was just adding the full sequence for clarity.

            1 Reply Last reply
            1
            • ElcidE Offline
              ElcidE Offline
              Elcid
              wrote on last edited by
              #15

              Just to report, the hub.item.value.set in msr 1.0 is working fine. I can send ir/rf codes, and initiate a rf/ir learn mode, i just have to listen for broadcasts to pick up the codes and copy and paste into msr.
              P.s. congrats on the release of 1.0 and thank you.

              1 Reply Last reply
              0
              • toggledbitsT Offline
                toggledbitsT Offline
                toggledbits
                wrote on last edited by toggledbits
                #16

                You should also be able to use remote.send_codes. The format of the code data can either be a base64 string (in the format base64:datadatadata), or a list of byte values as decimal or hex values separated by spaces or commas (e.g. 0x00 0x12 0x2a 0xfe 0x14 for hex, 0 18 42 254 20 for decimal, and mixing is OK).

                Should it support Pronto?

                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                ElcidE 1 Reply Last reply
                0
                • toggledbitsT toggledbits

                  You should also be able to use remote.send_codes. The format of the code data can either be a base64 string (in the format base64:datadatadata), or a list of byte values as decimal or hex values separated by spaces or commas (e.g. 0x00 0x12 0x2a 0xfe 0x14 for hex, 0 18 42 254 20 for decimal, and mixing is OK).

                  Should it support Pronto?

                  ElcidE Offline
                  ElcidE Offline
                  Elcid
                  wrote on last edited by Elcid
                  #17

                  @toggledbits remote.send_code has no input field.
                  Screenshot_20210720-001609.png

                  As shown in above image

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by toggledbits
                    #18

                    Whoops! I'll have that fixed in the next build. Remind me what package you are using (docker or bare metal, RPi, Linux, Windows?)

                    Edit: And the builds are up (latest).

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    1 Reply Last reply
                    0
                    • ElcidE Offline
                      ElcidE Offline
                      Elcid
                      wrote on last edited by Elcid
                      #19

                      no luck with remote.send_codes with format base64:JgBYAAABJ5UQFBITERQRFBEUEBURExIUEDkRORE4ETkRORETEjkQORE4EjkQFBEUERQRFBEUEBURExITETkSOBE4ETkRORE4EQAFPwABJ0sRAAxHAAEnSxEADQU=
                      build reactor-latest-21200-17fb925.tar.gz

                      1 Reply Last reply
                      0
                      • toggledbitsT Offline
                        toggledbitsT Offline
                        toggledbits
                        wrote on last edited by
                        #20

                        OK. Got your log file; thanks for that. Found the issue, will be fixed in today's "latest" build (21201).

                        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                        1 Reply Last reply
                        0
                        • ElcidE Offline
                          ElcidE Offline
                          Elcid
                          wrote on last edited by
                          #21

                          great, just one last question, I take it remote.send_codes will just send ir codes?

                          1 Reply Last reply
                          0
                          • toggledbitsT Offline
                            toggledbitsT Offline
                            toggledbits
                            wrote on last edited by
                            #22

                            Yes, do you need RF as well?

                            Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                            1 Reply Last reply
                            0
                            • ElcidE Offline
                              ElcidE Offline
                              Elcid
                              wrote on last edited by
                              #23

                              No, just confirming. I can use x_ezlo_device.set_item_value

                              1 Reply Last reply
                              0
                              • toggledbitsT Offline
                                toggledbitsT Offline
                                toggledbits
                                wrote on last edited by
                                #24

                                I'm actually going to remove the remote capability and split it into ir_remote and rf_remote... I kind of realized I made an error making the capability name too generic. So that will be in today's build, which will break your actions, but I don't think we'll need to change it again.

                                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                1 Reply Last reply
                                0
                                • ElcidE Offline
                                  ElcidE Offline
                                  Elcid
                                  wrote on last edited by Elcid
                                  #25

                                  I took your early advice and have only been testing on MSR. Now 1.0 has been released, I will of course now start moving from Reactor to MSR. Having Ezlo Broadlink has brought my Broadlink under local (not sure if ezlo is using local or cloud integration for Broadlink, msr>>ezlo>>broadlink>>device, It seem instantaneous)) control, and I can now drop my Alexa remote2 workaround.

                                  1 Reply Last reply
                                  0
                                  • toggledbitsT Offline
                                    toggledbitsT Offline
                                    toggledbits
                                    wrote on last edited by
                                    #26

                                    Cool. I just posted 21201. Since I can't test myself, you're the first to try. Let me know how it works out.

                                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                    1 Reply Last reply
                                    0
                                    • ElcidE Offline
                                      ElcidE Offline
                                      Elcid
                                      wrote on last edited by Elcid
                                      #27

                                      21201 failed to load ezlo controller, I have uploaded a log file to mantis bug tracker

                                      1 Reply Last reply
                                      0
                                      • toggledbitsT Offline
                                        toggledbitsT Offline
                                        toggledbits
                                        wrote on last edited by
                                        #28

                                        Can you look in your console logs (there is some logging that occurs prior to the internal logger being started, and it logs to the console), and see what it reports for the module path?

                                        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                        1 Reply Last reply
                                        0
                                        • ElcidE Offline
                                          ElcidE Offline
                                          Elcid
                                          wrote on last edited by
                                          #29
                                          module.paths [
                                            '/data/data/com.termux/files/home/reactor/node_modules',
                                            '/data/data/com.termux/files/home/node_modules',
                                            '/data/data/com.termux/files/node_modules',
                                            '/data/data/com.termux/node_modules',
                                            '/data/data/node_modules',
                                            '/data/node_modules',
                                            '/node_modules'
                                          ]
                                          NODE_PATH undefined
                                          
                                          1 Reply Last reply
                                          0
                                          Reply
                                          • Reply as topic
                                          Log in to reply
                                          • Oldest to Newest
                                          • Newest to Oldest
                                          • Most Votes


                                          Recent Topics

                                          • [Resolved] Hubitat upgrade 2.5.3.123 may have broken login
                                            3
                                            3rdStng
                                            0
                                            7
                                            64

                                          • Reactor (Multi-System/Multi-Hub) Announcements
                                            toggledbitsT
                                            toggledbits
                                            5
                                            153
                                            161.0k

                                          • Reactor Inspect - a small read-only helper panel for MSR
                                            G
                                            gwp1
                                            2
                                            8
                                            537

                                          • Reverse proxy & API ACL
                                            tunnusT
                                            tunnus
                                            0
                                            9
                                            433

                                          • MFA
                                            T
                                            tamorgen
                                            0
                                            28
                                            1.2k

                                          • Grouped devices
                                            G
                                            gwp1
                                            0
                                            3
                                            164

                                          • Login protections
                                            toggledbitsT
                                            toggledbits
                                            0
                                            2
                                            212

                                          • Reactor Build 26284 stuck at Loading Reactor UI
                                            T
                                            tamorgen
                                            0
                                            16
                                            1.7k

                                          • MSR with reverse proxy
                                            tunnusT
                                            tunnus
                                            0
                                            12
                                            868

                                          • Missing attribute after upgrade
                                            3
                                            3rdStng
                                            0
                                            3
                                            661

                                          • Use of Google Gemini as an MSR and Hubitat configuration aid
                                            therealdbT
                                            therealdb
                                            0
                                            2
                                            307

                                          • [MSR] Native fan capabilty
                                            therealdbT
                                            therealdb
                                            1
                                            3
                                            296
                                          Powered by NodeBB | Contributors
                                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                          • Login

                                          • Don't have an account? Register

                                          • Login or register to search.
                                          • First post
                                            Last post
                                          0
                                          • Categories
                                          • Recent
                                          • Tags
                                          • Popular
                                          • Unsolved