I've managed to use MSR UI on iOS devices to some degree*, so that although UI elements (e.g. rule sets) are not visible in portrait mode, you've seen them in landscape. Now with recents builds (24302) this does not work anymore, elements (rule sets, entities) are not anymore visible in landscape mode.
Does anyone have similar experiences? Using iOS 18 and Safari/Chrome browser.
( *Drag & drop of rule conditions have never worked on a mobile)
Hi @toggledbits,
I have lots of logs with this:
<Engine:ERR> Assignment to alarm ignored -- expression-driven global cannot be set by assignmentAny hints to where look at to avoid this? Thanks.
Hi @toggledbits
I'd like to update my controllers with these new features, but I'm struggling to find any guidance in the docs - and in general to understand the context.
Could you please elaborate more? Thanks.
I have the following ACL defined:
groups: admin: users: - admin applications: true api_acls: # This ACL allows users in the "admin" group to access the API - url: "/api" group: admin allow: true log: true # This ACL allows anyone/thing to access the /api/v1/alive API endpoint - url: "/api/v1/alive" allow: trueAnd I have authenticated to MSR as "admin" user. However, I'm getting "access denied" when trying to access http://*******:8111/api/v1/log
So what I'm missing, is my ACL incorrectly defined?
Using build 24302 on Docker.
Thanks to @toggledbits for adding a custom CSS. I've started doing a darker Reactor style.
Here's the file: https://gist.github.com/dbochicchio/825098ac13b7f8cac22012eae37ff7ce
A couple of things are still too bright and I'll eventually catch-up. Just place it under your /config directory, naming the file as customstyles.css. Hard refresh your browser.
Hi!
In Home Assistant I sometimes uses the TTS, either to my Sonos or Google speakers. With reactor in Vera I also use TTS.
But in MSR I can't select the TTS-service. It's simply not there. Am I missing something, or is this the case, so far?
Thanks!
/Fanan
Hi
I have just connected a bunch of EzloPi controllers to MSR to import some ESP based devices etc.
They all seemed to have worked and imported in to MSR apart from I have one missing device. It is a Digital Gas Sensor device.
This is how that device looks in the Ezlo API.
Devices Info:
_id: "10696001" deviceTypeId: "ezlopi" parentDeviceId: "10696000" category: "level_sensor" subcategory: "" gatewayId: "457a5069" batteryPowered: false name: "Gas Sensor Digital" type: "sensor" reachable: true persistent: true serviceNotification: false armed: false roomId: "" security: "no" ready: true status: "idle" parentRoom: true protectConfig: "default"Items Info:
_id: "20696001" deviceId: "10696001" hasGetter: true hasSetter: false name: "smoke_density" show: true valueType: "substance_amount" scale: "parts_per_million" value: 2.7472610473632812 valueFormatted: "2.75" status: "idle"There is also an Analog Gas sensor that one did import in to MSR OK.
68d63dab-b871-4f44-912b-cf6e0b9eb4c6-image.png
Devices Info:
_id: "10696000" deviceTypeId: "ezlopi" parentDeviceId: "10696000" category: "security_sensor" subcategory: "gas" gatewayId: "457a5069" batteryPowered: false name: "Gas Sensor Analog" type: "sensor" reachable: true persistent: true serviceNotification: false armed: false roomId: "" security: "no" ready: true status: "idle" parentRoom: true protectConfig: "default"Items Info:
_id: "20696000" deviceId: "10696000" hasGetter: true hasSetter: false name: "gas_alarm" show: true valueType: "token" enum: 0: "no_gas" 1: "combustible_gas_detected" 2: "toxic_gas_detected" 3: "unknown" valueFormatted: "no_gas" value: "no_gas" status: "idle"And this is how this MQ2 Gas Sensor looks like on their dashboard:
Digital
cb77dfa3-4af5-4d06-9635-89207a716a89-image.png
Analog
4fb4da1b-e946-4b89-876c-bcd9f5699b6c-image.png
They have an EzloPi website here you can create your own sensor projects using ESP boards, which is very interesting stuff!
And I just wrote on the Ezlo forum here, how to connect an EzloPi controller to MSR.
THANKS.
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.A couple of things for you @toggledbits, since you mentioned that this release has new features and some tweaks are expected.
Local expressions cannot be deleted. Pushing the X button has no effect for me.
When cloning an entity action, the result is strange (first is cloned one, second is the original action):
a92ea094-9e2c-4aaa-bf47-2d07a6ffdbd0-image.png
When changing the action on the cloned element, the params are added to the original one. See screenshot:
92ac3011-83c8-466b-bd23-47d483ad7a52-image.png
Dark theme has a couple of strange contrasts. One is visible in the previous screenshots (white text on yellow background). Another one is in groups (blue text on blue background):
9b3c4988-53ef-44e6-9672-30e744cacb75-image.png
Overall, I found blue, yellow, red and green (in buttons and forms) to be too bright.
On the bright side:
I love the new script action: thank you! The dark theme is a great start to avoid getting blinded at night I promise I'll try very soon the new features around actions. Thanks!@toggledbits
I just upgraded to version MSR 24293, bare metal running on Fedora. Upon restart, I am getting a error banner:
I followed the new directions about npm
npm i --no-save --no-package-lock --omit dev
Any idea what the issue is?
Seems like switching the UI to the newly added dark mode (thank you for this) does nothing. The UI stays in light mode and only a few buttons turn into dark mode (see screenshot)
Things I have tried:
Hard refresh
Different browser
Different computer
Restarting Reactor
Failed troubleshooting attempts:
No errors in Chrome console
No relevant errors in Reactor log (can still PM the full log file)
Reactor version: latest-24293-ea42a81d
Hardware: Odroid N2+
Linux version: Ubuntu 24.04.1 LTS
3df2806f-9146-485b-9ec1-d056e91cefe5-image.png Dark mode enabled
ff823023-c079-4684-b01f-d6ac6527d31a-image.png Light mode enabled
Good morning,
I have a service MQTT service that needs a restart occasionally. The add-on (Smartbed MQTT) is for the smart bed base for my bed. It has a "safety light" that I can control from HAAS & MSR as a light entity, and also moves the head of the bed to a preset at bedtime, and then lies it back flat in the morning The problem is, from time to time, the light becomes "unavailable" Restarting from the Add-ons tab in HAAS always fixes it, but I should be able to detect when it happens when "light.tempur_pedic_safety_lights" is not true or false, i.e., unavailable.
What I don't know how to do is how to restart that service. Does anybody have experience in restarting add-ons from MSR?
Running:
Reactor (Multi-hub) latest-24212-3ce15e25 ZWaveJSController [0.1.24232]HAAS:
RPi5-64 (8GB) Core 2024.7.3 Supervisor 2024.08.0 Operating System 13.0 Frontend 20240710.0Hi!
Is it possible to generate two additional log files, the first being the replica of what is displayed on screen by the Rule History widgets and the other with Recently Changed Entities?
And could I configure the generation of one file per day, and delete the older ones? For example, store the last 5 days?
And being more ambitious, does Windget have an icon to open these TXT files in the navigated?
Well, we're approaching Christmas, so here's my request to Santa Claus @toggledbits 🙂
Hi @toggledbits
I'm working on a controller to generate llm response from a prompt in reactor. I have http response coming thru an http request action at the moment, capturing the response inside a local variable. So, it's practically sync.
I want to create a controller, so I don't have to rely on a proxy (and have a simpler architecture), and duplicate absurd http actions, but AFAIK in the current implementation, actions are async only. But if I have multiple requests going on, I cannot be sure what it's really inside an attribute. I also thought that something like a correlation id when sending the request could be used to identity multiple responses, but I wanted to double check with you before starting with something too complicated. I also noticed that some actions in home assistant (ie forecast) are sync and I'm wondering if you have any plan or hint to address this situation. Thanks.
Thanks.
@togglebits I am curious as to why the tilt_sensor.state (primary) = NULL. I believe it should show true or false. I have to use binary_sensor.state instead in my rules.
Again, not sure if this is related to Reactor/ZwaveJSController implementation or the actual Z-Wave JS UI docker version. I have copied, below, the attributes of the tilt sensor in hopes it can help.
Thanks in advance.
Reactor version 23302
ZWaveJSController version 23254
Z-Wave JS UI version 9.3.0.724519f
zwave-js version 12.2.3
@toggledbits I have noticed after upgrading both Reactor and ZWaveJSController to version 24257 that two of my devices/entities, TILT-ZWAVE2.5-ECO and Zooz ZSE18, had their entity re-named in an unusual way and also appears to be duplicated.
Reactor version 24257
ZWaveJSController version 24257
Z-Wave JS UI version 9.18.1
zwave-js version 13.2.0
Vestibule Motion Sensor State attributes/partial screenshot of entities it created. All entities have the same attributes.
motion_sensor.state=true x_zwave_values.Notification_Home_Security_Motion_sensor_status=8 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=23 zwave_device.valueId=[113,"Notification","Home Security","Home Security","Motion sensor status","Motion sensor status"] zwave_device.version_info=nullTilt Sensor Door State and Tilt Sensor Door State Simple attributes/partial screenshot of entities it created. All entities have similar attributes with exception of x_zwave_values.Notification_Access_Control_Door_State = 22 or 23.
tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state_simple=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state_simple=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=nullI'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only).
Anyway, here's my reactor-mqtt-contrib package:
Contrib MQTT templates for Reactor. Contribute to dbochicchio/reactor-mqtt-contrib development by creating an account on GitHub.
Simply download yaml files (everything or just the ones you need) and you're good to go.
I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them.
The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression.
Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests 🙂
Having issues with a shell command
-
That's great thank you.
Next problem how to extract the data from the in rule expression and split out the PS4's power status out in to another expression ?
I guess either "statusLine" or "statusCode" could be used.
(string) "{\n \"type\": \"device\",\n \"statusLine\": \"200 Ok\",\n \"statusCode\": \"200\",\n \"status\": \"Ok\",\n \"host-id\": \"C863F1400EF1\",\n \"host-type\": \"PS4\",\n \"host-name\": \"PS4-806\",\n \"host-request-port\": \"997\",\n \"device-discovery-protocol-version\": \"00020020\",\n \"system-version\": \"08520011\",\n \"running-app-name\": \"Concrete Genie\",\n \"running-app-titleid\": \"CUSA11875\",\n \"address\": \"192.168.0.201\"\n}\n"
And you can see there is also a "running-app-name" Concrete Genie is the game being played currently.
-
Use another expression to put that string through the
parseJSON()
function and it will turn it into an object you can then pick the data out of. -
@toggledbits said in Having issues with a shell command:
parseJSON()
Like this ?
Contents of the expression "ps4wakerparse"
Last value:(object) {"type":"device","statusLine":"200 Ok","statusCode":"200","status":"Ok","host-id":"C863F1400EF1","host-type":"PS4","host-name":"PS4-806","host-request-port":"997","device-discovery-protocol-version":"00020020","system-version":"08520011","running-app-name":"Concrete Genie","running-app-titleid":"CUSA11875","address":"192.168.0.201"}
-
I don't know what the first expression is/was, but the second one is correct and has parsed the value correctly. You can now refer to data in the object via
ps4wakerparse.statusCode
for example. For names that contain special characters, likehost-id
, you need to use the alternate (quoted identifier) syntaxps4wakerparse["host-id"]
-
Seems to be working and pulling out the required data:
The first expression named "ps4wakercheck" is the inital output of the shell command "ps4-waker check".
-
OK. I see that it's not consistently clearing the error from some prior usage on
ps4wakercheck
, that's what's confusing/odd, so I've fixed that for today's build as well (PR 0000235). -
By the way, it's much more efficient to use expressions in
ps4powerstatus
andps4runningapp
than it is to use Set Variable actions to set them. That's kind of doing it the hard way. -
For the value in the expression "ps4powerstatus" its either going to be:
200 = ON
620 = OFFHow can I have another expression that will translate those code numbers in to human text that I can then send to Vera / Home Remote ?
Thanks
-
@toggledbits said in Having issues with a shell command:
By the way, it's much more efficient to use expressions in ps4powerstatus and ps4runningapp
Understood I have changed it and removed the set variable actions:
EDIT:
Don't think it likes that, I get these error when I press the "Reset" button on the rule.
-
That's right.
Show all the values when you post an error, please.
-
No errors there.
-
Have you removed the Set Variable actions?
-
@toggledbits said in Having issues with a shell command:
Have you removed the Set Variable actions?
Yes
The bell icon goes red when the rule is Reset.
-
Removing the actions is/was correct. I'll give this a try later today and see
-
Using a Vera Multistring plugin device.
I added these in the rules Reaction to send the values to the generic sensor device in Vera etc.
Just need to translate codes 200 and 620 to "On" and "Off" instead.
I could maybe delete these two expressions from the rule also.
EDIT:
I've just seen a new field called "status" maybe I can use that instead.
On = "OK"
Off = "Standby"
-
I had a moment to do a quick test. Duh; I'm forgetting my own code's behavior. This is actually pretty simple. When you reset the rule, all state and expression/variable values are removed, so effectively, everything is null. When the rule is then re-evaluated, expressions are evaluated first, and since
ps4wakercheck
is null at that point because the action has not yet run, thenps4wakerparse
is also null, so the last two expressions can't dereference through null and throw an evaluation error. This is actually all expected, correct behavior.You can probably just clear these two spurious errors (caused by the reset/no data condition at rule "boot"), as they will not happen again, typically. The only other way you would see this is if the command actually fails hard in some way and produces no parseable JSON output. Then you'll get alerts again, but that's probably good because you might want to know that.
Another way to handle it is to simply modify the last two expressions like this:
- ps4powerstatus =
ps4wakerparse?.statusCode
- ps4runningapp =
ps4wakerparse?["running-app-name"]
The
?.
and?[
operators, described in the docs, are special coalescing versions of the standard.
and[
operators that guard null on their left-hand operands. If the left-side operand value is null, the coalescing operator will simply return null and no error will be issued. I think this also makes sense in this application. These coalescing operators are provided for exactly this kind of case, so this is a perfect example of their use, and you should familiarize yourself with them (and apply them often). - ps4powerstatus =
-
You can map a value from one to another using a simple map object, like this:
mappedStatus =
( { '200': 'On', '620': 'Off' } )?[ ps4wakerparse.statusCode ] ?? "unknown"
Here, we create an object on the fly (the
( { ... } )
part), dereference through it using the?[
coalesce operator, which will return null if the value ofstatusCode
doesn't match anything in the object, and then use a final??
coalesce operator to change an unmapped/null to the wordunknown
-
@toggledbits said in Having issues with a shell command:
The ?. and ?[ operators
That fixes it the red alerts don't appear any more when Resetting the rule.
Thanks
-
Finished device in Vera:
Home Remote dashboard tile:
Had to just add an additional ? to this code to stop the red alert appearing again.
( { '200': 'On', '620': 'Off' } )?[ ps4wakerparse?.statusCode ] ?? "unknown"
And now the alert doesn't come back again when resetting the rule.
So I think everything is all working fine now, at least while the PS4 is turned ON.