Gradually turn on lights.
Tom_DT
I have several lights that I would like to turn on very gradually over 15 or 20 seconds. from 0 to .25 in .01 increments. I have tried a few things that came nowhere near working, so here I am.
Multi-System Reactor
Stop the MSR by an external switch on Hubitat.
wmarcolinW
Use case: When performing home maintenance, such as air conditioning, I want all rules involving air conditioning to be disabled. To do this, to day, I have a virtual switch that I placed within all rules involving air conditioning, meaning that if I turn it off, none of them work. Then another situation: the water pump system and garden irrigation, another switch. In short, I had to create several virtual switches in Hubitat to disable rules in MSR. Unfortunately, however, I was unable to cover all scenarios, so I wondered if it would be possible for MSR to support a virtual MSR switch, which, when configured in the reactor settings, would function as a general on/off switch for MSR. If it is configured and turned off, the entire rules and actions in MSR stops working, except for the status change reading process, specifically for this switch, which, when turned on, would restart the MSR. Would it be possible to do something like this? Any recommendations from the experts?
Multi-System Reactor
Error After Upgrade
T
Topic thumbnail image
Multi-System Reactor
Reset attribute value of entity in event handler
R
Topic thumbnail image
Multi-System Reactor
Need help figuring out how to delay a reset on reaction
T
Topic thumbnail image
Multi-System Reactor
Way to search for rules (rule state) in other rules
T
@toggledbits, not sure if this is a feature request or I'm using the search tool wrong. You have a "Search for rule" in the Rules Set tab in MSR. It works nicely to find a rule and bring up said rule, but can it/could it be used for as a "where used?" global search? For instance, I have a fairly large set of rules, divided up into 10 different rulesets. There's easily a hundred individual rules, and many of the rules have Rule State triggers, which of course refer to other rules. Amongst my troubleshooting today, I came across what may have been a duplicate or troubleshooting attempt, but I can't tell if it's actually used as a Rule State in another rule without opening each rule that I suspect it may be a part of. Thanks.
Multi-System Reactor
Links to MSR from HA
Tom_DT
I am using Home Assistant a lot recently. On a dashboard showing the devices, I would like to show a link to the MSR rule that controls the devices. Is there a way to link directly into MSR?
Multi-System Reactor
Set Reaction > Script Action
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Errors after updating to MQTTController build 25139
tunnusT
I'm running MSR build 25139 on Docker, using MQTT controller 24293, and everything working as expected. But if I try to upgrade to MQTTController build 25139, I'm getting the following errors on MSR UI: An Entity Attribute condition in "Lay-Z-Spa auto heating off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.god Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa auto heating off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute temperature_sensor.green Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa filter pump auto off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute temperature_sensor.red Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa filter pump auto run" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.pump Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa watchdog" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.status Last 11:20:37 My MQTT configuration (local_mqtt_devices.yaml) for the related entity is: layzspa_message: type: ValueSensor capabilities: ["temperature_sensor", "value_sensor", "power_sensor"] primary_attribute: power_sensor.value events: "layzspa/message": "power_sensor.value": json_payload: true if_expr: '! isnull( payload?.PWR )' expr: "float(payload.PWR)" "value_sensor.air": json_payload: true if_expr: '! isnull( payload?.AIR )' expr: "float(payload.AIR)" "value_sensor.pump": json_payload: true if_expr: '! isnull( payload?.FLT )' expr: "float(payload.FLT)" "value_sensor.god": json_payload: true if_expr: '! isnull( payload?.GOD )' expr: "float(payload.GOD)" "value_sensor.lock": json_payload: true if_expr: '! isnull( payload?.LCK )' expr: "float(payload.LCK)" "value_sensor.unit": json_payload: true if_expr: '! isnull( payload?.UNT )' expr: "float(payload.UNT)" "value_sensor.error": json_payload: true if_expr: '! isnull( payload?.ERR )' expr: "float(payload.ERR)" "temperature_sensor.green": json_payload: true if_expr: '! isnull( payload?.GRN )' expr: "float(payload.GRN)" "temperature_sensor.red": json_payload: true if_expr: '! isnull( payload?.RED )' expr: "float(payload.RED)" "temperature_sensor.target": json_payload: true if_expr: '! isnull( payload?.TGT )' expr: "float(payload.TGT)" "temperature_sensor.value": json_payload: true if_expr: '! isnull( payload?.TMP )' expr: "float(payload.TMP)" "temperature_sensor.virtual": json_payload: true if_expr: '! isnull( payload?.VTM )' expr: "round(float(payload.VTM), 1)" "temperature_sensor.ambient": json_payload: true if_expr: '! isnull( payload?.AMB )' expr: "float(payload.AMB)" "layzspa/Status": "value_sensor.status": if_expr: '! isnull( payload )' expr: "payload" "layzspa/button": "value_sensor.button": if_expr: '! isnull( payload )' expr: "payload" and in reactor.yaml I have: "layzspa_states": name: "Lay-Z-Spa States" friendly_name: 'Lay-Z-Spa States' include: layzspa_message I realize my MQTT configuration might be a bit unorthodox, but could there still be something unintentional in the latest MQTTController build? If needed, I can provide detailed logs.
Multi-System Reactor
🎉 My very first MSR controller: OpenSprinkler
therealdbT
Since today is my birthday - and I still pretend to be unconventional - I'm giving away a present to this wonderful community and I'm releasing my first OpenSprinkler controller for MSR. It was real fun to code it - and while it's still WIP, it seems to work OK for me. It's polling-based at the moment, but I'll add support for updates via MQTT very soon (it's already partially coded). Get it at (install is similar to MQTTController and such): https://github.com/dbochicchio/reactor-opensprinkler Feel free to try it. It's beta software, but it's stable. I'll update it weekly until all the tasks from my todo list are empty. Since I've learnt a lot from this controller, I'll explore new controllers soon.
Multi-System Reactor
Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor

Passing expression variables between rules

Scheduled Pinned Locked Moved Multi-System Reactor
9 Posts 2 Posters 518 Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • M Offline
    M Offline
    maddios
    wrote on last edited by maddios
    #1

    Is there a way to get a variable from a rule into an expression of some other rule?

    Just like what Vera Reactor did with the Export button then allowing you to reference that variable in another rule set. I'm guessing there's a function like there was in vera getstate()? Thanks

    Hopefully my question is clear, it's late 🙂

    1 Reply Last reply
    0
    • M Offline
      M Offline
      maddios
      wrote on last edited by
      #2

      I've found I can see variables from other rule sets within the rules themselves, via the "Variable Value" condition type. Just need to figure out now how to get to this in an expression.

      toggledbitsT 1 Reply Last reply
      0
      • M maddios

        I've found I can see variables from other rule sets within the rules themselves, via the "Variable Value" condition type. Just need to figure out now how to get to this in an expression.

        toggledbitsT Offline
        toggledbitsT Offline
        toggledbits
        wrote on last edited by
        #3

        @maddios said in Passing expression variables between rules:

        I've found I can see variables from other rule sets within the rules themselves

        That's a bug. Rule-based expressions are only in scope within the rule that defines them (just as local variables in almost any language are available in the scope that defines them). For the same reason, you cannot refer to variables in other rules from an expression.

        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

        1 Reply Last reply
        0
        • M Offline
          M Offline
          maddios
          wrote on last edited by maddios
          #4

          Ah, so I can't copy over some of my vera reactor logic.

          How do I reference global variables within rules? do they just work like local variables? or is there some sort of global scope object I have to use?

          I'm guessing I can pass data between rules by using a global expression

          Also, how do you recommend structuring one of your old guides where a bathroom humidity sensor samples humidity into a dictionary then calculates averages and such. then another vera reactor was consuming that average and checking if it's above/below current humidity and turning a fan on off?

          Thanks

          1 Reply Last reply
          0
          • M Offline
            M Offline
            maddios
            wrote on last edited by
            #5

            Let me know if this is correct, I'm using a reaction in a rule to set the global average expression to my local ${{average}}. Is that the correct way?

            1 Reply Last reply
            0
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by
              #6

              You refer to global variables the same way you refer to local ones, as you would in most computer languages.

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              0
              • toggledbitsT Offline
                toggledbitsT Offline
                toggledbits
                wrote on last edited by toggledbits
                #7

                You refer to global variables the same way you refer to local ones, as you would in most computer languages. You simply refer to it by name. If the name is not in local scope, the parent scope (which is the global scope in Reactor) will be searched for the name.

                Ref: https://reactor.toggledbits.com/docs/Expressions-%26-Variables/

                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                1 Reply Last reply
                0
                • M Offline
                  M Offline
                  maddios
                  wrote on last edited by
                  #8

                  Thanks, that worked for my needs. So far I like this new system, seems much snappier.

                  1 Reply Last reply
                  0
                  • M Offline
                    M Offline
                    maddios
                    wrote on last edited by
                    #9

                    Not sure if anyone's suggested this, but it would be great if the expressions could be grouped. Like for me I have tons of variables for my thermostats, tracking all sorts of house parameters which all of the thermostats share. Would be great to have an object to contain them all so I don't have all of the expressions mixed up. something like thermostat.first_floor.heat_current_setpoint would be really cool.

                    1 Reply Last reply
                    0
                    • toggledbitsT toggledbits locked this topic on
                    Reply
                    • Reply as topic
                    Log in to reply
                    • Oldest to Newest
                    • Newest to Oldest
                    • Most Votes


                    Recent Topics

                    • Gradually turn on lights.
                      G
                      gwp1
                      0
                      4
                      93

                    • Stop the MSR by an external switch on Hubitat.
                      wmarcolinW
                      wmarcolin
                      0
                      1
                      16

                    • Error After Upgrade
                      G
                      gwp1
                      0
                      4
                      84

                    • Reset attribute value of entity in event handler
                      R
                      RHCPNG
                      0
                      5
                      170

                    • Need help figuring out how to delay a reset on reaction
                      G
                      gwp1
                      0
                      22
                      858

                    • Way to search for rules (rule state) in other rules
                      T
                      tamorgen
                      0
                      3
                      91

                    • Links to MSR from HA
                      Tom_DT
                      Tom_D
                      0
                      1
                      77

                    • Set Reaction > Script Action
                      wmarcolinW
                      wmarcolin
                      0
                      11
                      416

                    • Wiring Samotech SM308-S into light fitting
                      akbooerA
                      akbooer
                      0
                      2
                      136

                    • Errors after updating to MQTTController build 25139
                      toggledbitsT
                      toggledbits
                      0
                      6
                      232

                    • 🎉 My very first MSR controller: OpenSprinkler
                      therealdbT
                      therealdb
                      5
                      13
                      898

                    • Advice reqeusted to migrate MSR from Bare Metal to Container
                      T
                      tamorgen
                      0
                      5
                      246
                    Powered by NodeBB | Contributors
                    Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                    • Login

                    • Don't have an account? Register

                    • Login or register to search.
                    • First post
                      Last post
                    0
                    • Categories
                    • Recent
                    • Tags
                    • Popular
                    • Unsolved