No worries, I've ordered a UZB just to see
Hansel
Build 24343 has fully HTTP actions, so cool things could be created (see docs). I've recently changed a couple of cams because better definition and I've found tha Reolink has a couple of cams that have spotlights. While the spotlights are driven by motion (so the cam could record in color), I wanted to drive them directly, so in case of any "security" event, like alarm on, door open, etc, I could use the lights to have a better video and make - you know - light.
So, if you want to use HTTP actions in VirtualController, just go to config, entities under your VirtualEntityController section in reactor.yaml, and add this:
- id: cams_retro_spotlights name: "Retro Cam - Spotlights" template: Binary Switch # update the status at interval http_request: interval: 900 # 15m url: "http://192.168.1.31/cgi-bin/api.cgi?user=foo&password=foo" method: "POST" force_json: true headers: "Content-Type": "application/json" "Accept": "application/json" body: '[{"cmd": "GetWhiteLed", "action": 0 , "param": { "channel": 0 }}]' capabilities: power_switch: attributes: state: expr: "isnull( response ) ? null : response[0]?.value?.WhiteLed?.state == 1" default: false actions: "on": http_request: url: "http://192.168.1.31/cgi-bin/api.cgi?user=foo&password=foo" method: "POST" force_json: true headers: "Content-Type": "application/json" "Accept": "application/json" body: '[{"cmd": "SetWhiteLed", "param": { "WhiteLed": {"bright" : 100, "channel": 0, "mode": 1, "state": 1}}}]' target: state expr: "isnull( response ) ? null: response[0]?.value?.rspCode == '200'" "off": http_request: url: "http://192.168.1.31/cgi-bin/api.cgi?user=foo&password=foo" method: "POST" force_json: true headers: "Content-Type": "application/json" "Accept": "application/json" body: '[{"cmd": "SetWhiteLed", "param": { "WhiteLed": {"bright" : 100, "channel": 0, "mode": 1, "state": 0}}}]' target: state expr: "isnull( response ) ? null : response[0]?.value?.rspCode == '200' ? false : null"Reolink has API where you have to post a JSON and the response will give you a JSON (in theory). It's not really JSON, so force_json: true will do the trick for you. I'm lefting this as an example of cool things you could do with the new capabilites added/documented in 24343. HTH.
Thanks to @toggledbits for adding a custom CSS. I've started doing a darker Reactor style.
Here's the file: https://gist.github.com/dbochicchio/825098ac13b7f8cac22012eae37ff7ce
A couple of things are still too bright and I'll eventually catch-up. Just place it under your /config directory, naming the file as customstyles.css. Hard refresh your browser.
Hi
Having to rebuild my Linux Debian box as the SSD failed. And I have forgotten exactly what I did the first time to get it all setup.
I have Debian 12 up and running on the new SSD, I only have console no Desktop GUI.
I am trying to do the bare metal install for MSR. However I am not sure if I am meant to install nodejs whlist logged in as the root user or as the none root user with my name ?
I used putty and connected via SSH and logged in as root and I installed nodejs but I think this was wrong as when logged in as my user name and I do a node -v command it says node is not installed or doesn't show any version number anyway.
But when logged in as root and I do a node -v command it does show me its installed and displays the version number. maybe its a path issue for my username and he can't see node is installed?
So now I am thinking I should of installed node whilst logged in as my user name and not as the root user.
This is how I installed nodejs as whilst logged in as root
ac7bf6c3-23ad-46fc-8ada-44af6704e63e-image.png
Thanks in advance.
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.As the title says, here's my OpenAI Controller for Reactor:
OpenAI Controller per Reactor. Contribute to dbochicchio/reactor-openai development by creating an account on GitHub.
It supports both OpenAI and Azure OpenAI endpoints. You'll need keys/endpoints, according to each service.
The controller supports multiple models, and each one could be mapped as an entity.
It's quite easy to use, and responses can be stored in variables, for easy access. Or sent to another action (Text To Speech, another endpoint, etc).
9013ae50-fd68-42a2-87c3-97479132e465-image.png
80a88eec-7c89-464a-8196-690b4b72d044-image.png
Have fun with LLM into your scenes!
I've switched to a virtual entity with both power_switch and string_sensor capabilities to represent the current holiday.
The power switch is used to indicate if it's a public holiday (so, no school/work), while the string sensor is a string with the actual holiday (Easter, Christmas, Halloween, etc - we don't have thanksgiving), mostly to drive lights.
I build it with some static dates (mostly birthdays/anniversaries) and then the dynamics ones are taken from webcal.guru. My lights/scenes are linked to events this way and it's easier to manage it in the long run: just a bunch of group action in the reaction driving the lights. This part is outside Reactor for me (because, legacy), but it's not difficult to completly drive it off a virtual sensor or a custom controller.
I don't know how people are doing this, but I'm lefting a note for the ones looking for a working solution.
In Home Assistant I have an integration that if I add entities to it, I will get the following error in MSR as certain entity values I'm using in expressions are null for a moment. This is more or less cosmetic issue and happens very rarely as I rarely modify that integration on the hass side.
Screenshot 2024-11-28 at 22.20.41.png
And the expression is
Screenshot 2024-11-28 at 22.38.19.png
Could I "wrap" hass-entity shown above somewhat differently to prevent this error from happening? Using build 24302.
Hello
I am trying to set up Multi System Reactor to automate routines across multiple smart home devices & platforms (e.g., Home Assistant, SmartThings, and Hubitat). While I have successfully linked the systems; I am facing issues with:
-Delays in triggering actions on secondary devices.
-Inconsistent execution of complex logic conditions.
-Synchronization of states between devices when one system updates.
Is there a recommended way to optimize performance & confirm seamless state sharing across systems?
I have checked https://smarthome.community/category/22/multi-system-reactor-msbi guide for reference but still need advice.
Any tips on debugging or log analysis to pinpoint where the issue arises would also be appreciated.
Thank you !
Hello AK
Have been writing about the openLuup email server as I was tinkering with it the other day. One minor problem: it looks like the domain part of the email address eg ...@openLuup.local is case sensitive in openLuup.
Looking round the net, it suggests that the local part is case sensitive but the domain part is not meant to be. To keep things so they are more likely to work, it's suggested the email address should be totally case insensitive regardless. Refer to rfc2821 page 13 or search on the word "sensitive". Suffice to say I was using mail@openluup.local rather than mail@openLuup.local, so it didn't work for me.
Next challenge was that the file saved in /etc/cmh-ludl/mail has "Content-Transfer-Encoding: base64" so the body of the email was encoded:
Received: from ((openLuup.smtp) [ip_address_1] by (openLuup.smtp v18.4.12) [ip_address_2]; Tue, 26 Nov 2024 14:21:22 +1000 From: "dali@switchboard" <dali@switchboard> To: "mail@openLuup.local" <mail@openLuup.local> Subject: Warning form R2E. MIME-Version: 1.0 Content-Type: text/plain Content-Transfer-Encoding: base64 QXV0byBXYXJuaW5nOiBDb2xkIHN0YXJ0IGV2ZW50The above base 64 text translates to "Auto Warning: Cold start event".
Is it your preference to leave the saved files in the raw mode or would you consider translating the base64 text in the openLuup code base?
On a side note, does the reception of an email by openLuup generate some sort of trigger that can be watched. In the case above; the email represents the restoration of power after a power outage. I would like to know about that by the email triggering a "Telegram" notification on my mobile.
I see that the images@openLuup.local images@openLuup.local can be associated with I_openLuupCamera1.xml, which spawns a movement detector child. Anything similar for the other email addresses?
I've managed to use MSR UI on iOS devices to some degree*, so that although UI elements (e.g. rule sets) are not visible in portrait mode, you've seen them in landscape. Now with recents builds (24302) this does not work anymore, elements (rule sets, entities) are not anymore visible in landscape mode.
Does anyone have similar experiences? Using iOS 18 and Safari/Chrome browser.
( *Drag & drop of rule conditions have never worked on a mobile)
@toggledbits Since I have upgraded ZWaveJSController to 24293 from 24257 I am seeing entries related to registering action set_volume, but action is not defined by the capability 143 every time I restart Reactor.
The Siren seems to be doing what it is supposed to do. The volume levels are fine. Should I worry about it?
Reactor version 24302
ZWaveJSController version 24293
Z-Wave JS UI version 9.27.4
zwave-js version 14.3.4
I have an oven that I need to manage the temperature of, keeping it in the neighborhood of 600° C (1100° F). I have not been able to find a Zigbee-enabled solution to measure temps that high. Does anyone know if such a thing exists? If not, any ideas for how to roll a custom solution that I could integrate into a Sonoff ihost controller? I have no trouble finding high temperature probes, but none of them interface with my automation stack.
Hi All
Hopefully this place looks like a helpful forum as I’m quite new to all this!
I’ve had a few devices all working separately /through their proprietary apps but we’re just finishing off a large house extension and this has added to the list.
I’d ideally like to be able to view/switch a number of different devices on one screen/head end but have no idea where to start.
The devices we have/will have shortly are as follows;
Zigbee Smart Sockets
Zigbee smart switches (for lights)
Heatmiser Neo Underfloor Heating (this runs from a Samsung ASHP but that part is automatic)
Samsung VRF air conditioning (currently using Smart Things App)
Hive (2xLTHW heating circuits in the existing house and Hot Water)
Ring (doorbell!)
Hik Vision PoE CCTV
We have lots of appliances (Neff N70) which we can control remotely but not too fussed about controlling those at the
Moment)
Any help/recommendations would be appreciated!
Thanks
Adrian
After a major hassle got z-way running on my ubuntu 16 VM with a USB pasthough UZB1 stick including license and connected to Vera...
I see:
I also see:
0d6e8c78-c8cd-4307-9474-23e0d6a55094-image.png
But how do I update that?
e09ffa19-a31d-4a03-8983-01228bc5478f-image.png
I have a legacy home automation set-up running on Windows XP. the computer and software have now died.
I have written a very nice Excel VBA program to replace the software and it can run on any modern Windows system.
My only remaining problem is to output the correct signal to a USB port to trigger the wireless switches.
Has anybody done a similar exercise. Please help.
The locksmith is trying to persuade me to purchase the BE-TECH K35 touchscreen lock with both Wi-Fi and Bluetooth, claiming it's better than the Yale Assure Lock 2. What are your thoughts on this? Which one would you recommend?
Here is the link to the Chinese brand BE-TECH: BE-TECH Smart Deadbolt K3S.
The other smart lock I am considering is the Schlage Encode Plus.
Thank you!
Hi All,
Kind of new to Home Automation. Started off Using Amazon Echo units and added a Samsung SmartThings hub. I have mostly been using plug in modules for turning lights on and off. I live in a very rural area where the internet goes out a lot. I eventually want to change to to a non internet Hub so things will work without needing an internet connection. But I will post with those questions at a later date.
So, the task at hand is this: I have flood lights at each corner of my house. They are currently controlled by switches at the front and back doors. I would like to add Security Cameras to each corner also. I can easily find small Wifi switches to put into the electrical box where the flood lights are located, then I can terminate the leads together behind the Decora switch to have constant power. Then I can use the constant power up at the lights electrical box to power the security cameras. I would also like to have a wireless switch to take the place of the Decora switch to be able to turn the lights off and on.
I cannot seem to find a product like this. It seems I can find the small wired in switch boxes that will also come with external smart wall switches, but the wall switches are an external box that does not fit in or cover the existing Wall switch electrical box. I can also find Wireless Decora switches that come with a remote wired in small switch box , but they all seem to be RF and do not integrate with a Smart Hub.
I am hoping someone here knows of a product that matches what I am looking for. Any help would be appreciated.
Also any recommendations for Wireless Security cameras are welcome.
Thanks for any help.
Posts
-
(Problem) Migration Z-Wave NW from Vera to UZB1 dongle -
(Problem) Migration Z-Wave NW from Vera to UZB1 dongleOk, so. Reloading the luup engine doesn't remove the dongle.restore or turn in into dongle.restore.go, but rebooting the vera seems to. I checked the logs and I see this:
ZWJob_BackupDongle::FindFileToRestore found 12 files using /etc/cmh/dongle.6.1.dump.0 timestamp 1630736238 / 2021-09-04 16:17:18 version 6.1 md5 30586bc3340164f7dccfb39ca218dda1 <0x77f00320>
01 09/06/21 11:53:40.943 ZWJob_BackupDongle::FixupBufferVersion don't know how to validate since there's no zensys in the firmware <0x77f00320>
01 09/06/21 11:53:40.943 ZWJob_BackupDongle::FixupBufferVersion don't know how to convert from 6.1 to 3.95 <0x77f00320>
01 09/06/21 11:53:40.944 ZWJob_BackupDongle::ZWJob_BackupDongle restore file invalid <0x77f00320>
10 09/06/21 11:53:40.944 FileUtils::DelFile /etc/cmh/dongle.restore.go <0x77f00320>So I assume from that it doesn't recognise the file as valid so it just deletes it. I assume the 6.1 to 3.95 complaint is the version (the Vera version on the Z-Wave Settings page was 6.1, and the Aeotec stick version on that page is Version: 3.95 L:1).
No idea if any of that is useful for troubleshooting?
-
(Problem) Migration Z-Wave NW from Vera to UZB1 dongleI’m having this same issue unfortunately (but with a gen5 aeotec stick). I’ll give it another try tomorrow when I get a chance, but it was basically the same issue of the restore file not changing to restore.go after a luup reload.
-
Method to get the security key from Vera?Ah thanks so much
-
Method to get the security key from Vera?Hi there,
I know this was floating around on the other forum but just hoping someone can post the steps as I’m finally biting the bullet and moving to a USB stick and Zwave JS in home assistant.
Thanks!