Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor

calculate with MSR variables in LuaXP

Scheduled Pinned Locked Moved Multi-System Reactor
9 Posts 3 Posters 562 Views 3 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • E Offline
    E Offline
    Edwin1972
    wrote on last edited by
    #1

    In MSR I have found that you can use lua code. Can I also calculate in lua with MSR variable? I have the following varaible in MSR:

    63efe6bb-0920-4497-aa6e-6894e2102891-image.png

    TotalTimeUp
    TimeUp_Start
    TimeDown_Start
    TimeStop
    South_Manual_MoveTime

    I want to calculate below

    if TotalTimeUp == TimeStop THEN
    South_Manual_MoveTime == (TimeUp_Start-TimeStop)
    End
    If TotalTimeDown == TimeStop
    South_Manual_MoveTime == (TimeStop-TimeDown_Start))
    END

    Maybe someone can help me

    1 Reply Last reply
    0
    • toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by toggledbits
      #2

      You cannot use Lua code in MSR; you can ask a Vera controller connected to MSR to run some Lua code on the Vera, which is what the action you posted in your screen shot would do (although the Lua you provide there isn't actually a valid script).

      You also cannot use MSR variables in Lua running on the Vera. The Vera cannot "see" the MSR variables. You could, in theory, build up Lua as a string and place MSR expression results into the built-up string, which would then be sent to the Vera to be executed, but this is a kludge and is not the same as using a variable from MSR in the Lua code (i.e. you could not set the variable in the Lua code and have the value magically port back to the MSR variable's value).

      You can do the expressions above in the MSR expression language, although (I see an X-Y problem here) I suspect there are behaviors and side-effects of this you are hoping for or expecting that would not be true (some would apply both to Lua and MSR expressions).

      Why don't you tell us what you are actually trying to do, rather than asking us about one piece of how you think your problem can be solved? Your approach may be valid in some contexts, but maybe not the best/easiest way on Vera or MSR.

      Note: there is no LuaXP in MSR. LuaXP is Reactor for Vera's expression language, written in Lua. MSR uses an entirely different expression language written on entirely different code. So don't use any LuaXP knowledge or documentation to try to solve expression puzzles in MSR. The information you need for MSR is here.

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      E 1 Reply Last reply
      0
      • E Offline
        E Offline
        Edwin1972
        wrote on last edited by
        #3

        Thanks for the quick response. Clear answer. I will try to describe my project later. The forum may be able to help me further.

        1 Reply Last reply
        0
        • LibraSunL Offline
          LibraSunL Offline
          LibraSun
          wrote on last edited by
          #4
          This post is deleted!
          1 Reply Last reply
          0
          • toggledbitsT toggledbits

            You cannot use Lua code in MSR; you can ask a Vera controller connected to MSR to run some Lua code on the Vera, which is what the action you posted in your screen shot would do (although the Lua you provide there isn't actually a valid script).

            You also cannot use MSR variables in Lua running on the Vera. The Vera cannot "see" the MSR variables. You could, in theory, build up Lua as a string and place MSR expression results into the built-up string, which would then be sent to the Vera to be executed, but this is a kludge and is not the same as using a variable from MSR in the Lua code (i.e. you could not set the variable in the Lua code and have the value magically port back to the MSR variable's value).

            You can do the expressions above in the MSR expression language, although (I see an X-Y problem here) I suspect there are behaviors and side-effects of this you are hoping for or expecting that would not be true (some would apply both to Lua and MSR expressions).

            Why don't you tell us what you are actually trying to do, rather than asking us about one piece of how you think your problem can be solved? Your approach may be valid in some contexts, but maybe not the best/easiest way on Vera or MSR.

            Note: there is no LuaXP in MSR. LuaXP is Reactor for Vera's expression language, written in Lua. MSR uses an entirely different expression language written on entirely different code. So don't use any LuaXP knowledge or documentation to try to solve expression puzzles in MSR. The information you need for MSR is here.

            E Offline
            E Offline
            Edwin1972
            wrote on last edited by Edwin1972
            #5

            @toggledbits My explanation of my project

            I use somfy motors (rfx) to open and close my roman blinds electrically. I can control this via RFXtrx433E USB Transceiver connect to my Vera. RFX gives no feedback so I can only open and close them and not moving them to a position based on the percentage of the slider. The RFX plugin (Tinmann) works with a slider related on MaxMoveTime (time to go from completely open to completely close)., but it doesn’t work with somfy. So I started my own project.

            I have installed the switchboard plugin on my Vera. I have created a virtual switch (virtual window coverings) and use it in MSR to close my blinds with the slider based on MaxMoveTime (time to go from completely open to completely close). It works with Vera and also with voice control by google home.

            MRS setting:
            Expression : LoadLevel_Last_Oost, MaxMoveTime_Oost

            c54f6eef-6c95-4e79-b5af-ade45904c297-image.png

            What I haven't solved yet is the following:
            I can operate Romand blinds by MSR with time schedule but would like to operate Roman blinds manually with the fibaro roller shutter 2, double click down / up and triple click stop function. For example, with a double click function I can start the following action:

            a6473fa6-4705-4fe0-b364-8bfd00f567bf-image.png

            I am using the virtual window covering (Switchboard) and switching up (double click Up), down (double click down) and stop (Triple click down). Switchboard can simulate motor movement of the covering by ramping LoadLevelStatus at a rate of XX% per second to the target value. This is the problem.
            MaxMoveTime (time to go from completely open to completely close) = 40 sec. Switchboard simulate motor movement = 34 sec (RampRatePerSecond =2).

            To set simulate motor movement =40 seconds, RamRatePerSeconde should be = 2.35. This does not work because they must be integer number. Is there a possibility to set the MaxMoveTime to simulate motor movement instead of movement % per sec?

            1 Reply Last reply
            1
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by toggledbits
              #6

              There's nothing enforcing RampRatePerSecond being an integer. Have you tried setting it to 2.35? It should work. The only thing that stands out as "iffy" about the whole idea is that the resolution of the timer on Vera is one second, so if the target isn't an even multiple of the ramp rate times the number of seconds needed to get to target, it will overshoot. For example, if the target is going to 22 from 0, that's 10 seconds ramping at 2.35/sec and will give you 23.5 position, not 22. And it will store the fraction in LoadLevelStatus which is probably going to make something crazy somewhere, so I've updated the stable branch release on Github to make sure it only writes the rounded whole number to LoadLevelStatus (but otherwise preserves the resolution of RampRatePerSecond).

              BTW, if it takes 40 second to go 0 to 100, that's 2.5 ramp rate, not 2.35.

              Github stable: https://github.com/toggledbits/Switchboard-Vera/tree/stable

              To install on Vera:

              1. Click the green "Code" button and choose "Download ZIP"
              2. Unzip the downloaded file.
              3. Open Apps > Develop apps > Luup files in Vera web UI
              4. Drag files (only, not folder) to "Upload button"
              5. When upload and reload finish, hard-refresh your browser.

              Expected version number in Switchboard control panel: 21098

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              0
              • E Offline
                E Offline
                Edwin1972
                wrote on last edited by Edwin1972
                #7

                Thanks! I have installed version 21098 on my vera and I entered 2.5 but it returns the same as 2. With stopwatch about 50 sec.

                1 Reply Last reply
                0
                • toggledbitsT Offline
                  toggledbitsT Offline
                  toggledbits
                  wrote on last edited by
                  #8

                  OK. Pull the latest stable again and install it. I did another update. This is a much better ramp for fractional timing. Still won't be absolutely perfect, but should not be wildly off. I've also added a "Ramping" state variable you can use to see if it's "in motion".

                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                  E 1 Reply Last reply
                  1
                  • toggledbitsT toggledbits

                    OK. Pull the latest stable again and install it. I did another update. This is a much better ramp for fractional timing. Still won't be absolutely perfect, but should not be wildly off. I've also added a "Ramping" state variable you can use to see if it's "in motion".

                    E Offline
                    E Offline
                    Edwin1972
                    wrote on last edited by Edwin1972
                    #9

                    @toggledbits
                    Yes, it works! Excellent.
                    Thank you for your time! Now I can continue my project. The new variable is also useful.

                    1 Reply Last reply
                    1
                    • toggledbitsT toggledbits locked this topic on
                    Reply
                    • Reply as topic
                    Log in to reply
                    • Oldest to Newest
                    • Newest to Oldest
                    • Most Votes


                    Recent Topics

                    • Advice reqeusted to migrate MSR from Bare Metal to Container
                      T
                      tamorgen
                      0
                      5
                      33

                    • Reactor (Multi-System/Multi-Hub) Announcements
                      toggledbitsT
                      toggledbits
                      5
                      122
                      35.4k

                    • Z-Wave Future....
                      CatmanV2C
                      CatmanV2
                      0
                      5
                      125

                    • Can´t restart or upgrade/deploy MSR
                      toggledbitsT
                      toggledbits
                      0
                      4
                      83

                    • [Solved] Limit HA Entity in MSR
                      wmarcolinW
                      wmarcolin
                      0
                      7
                      188

                    • Disaster recovery and virtualisation
                      CatmanV2C
                      CatmanV2
                      0
                      5
                      655

                    • Remote access of Zwave stick from Z-wave server
                      CatmanV2C
                      CatmanV2
                      0
                      3
                      380

                    • Organizing/ structuring rule sets and rules
                      G
                      gwp1
                      0
                      5
                      373

                    • Moving MSR from a QNAP container to RP 5 - some issues
                      G
                      gwp1
                      0
                      5
                      343

                    • Widget deletion does not work and landing page (status) is empy
                      G
                      gwp1
                      0
                      4
                      335

                    • Need help reducing false positive notifications
                      T
                      tamorgen
                      0
                      7
                      518
                    Powered by NodeBB | Contributors
                    Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                    • Login

                    • Don't have an account? Register

                    • Login or register to search.
                    • First post
                      Last post
                    0
                    • Categories
                    • Recent
                    • Tags
                    • Popular
                    • Unsolved