Thanks! It works
-
Hello Everyone -
I have a peculiar situation that I'm hoping to get some help with.
Running Vera which is still handling my Zwave, MySensors, Zigbee, and still a balance of my Reactors.
However, I've also been running MSR for several months in preparation for an eventual move off of Vera.
Vera had one of its meltdowns this morning related to my Opensprinkler plug in.
After getting that straightened out, I added the OpenSprinkler plugin to HAAS and that's when I started having issues.
My existing MSR reactors (even simple ones) don't seem to fire their reactions. I can see the conditions go "true". If I manually fire the Reaction, it works fine.
I do see this a lot in the logs:
[1.0.2-21350]2022-05-16T19:02:44.518Z <Rule:INFO> Rule#rule-460 evaluation in progress; waiting for completion(Various rules - 460 is just an example)
Is there anything I can do to further troubleshoot?
-
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed. -
My MSR has been working flawlessly until a couple of days ago when it stopped sending Telegram Messages (or should I say they stopped getting through!). I have updated to MSR version 22004. The reactor.log is updating and is showing no errors:
[latest-22004]2022-05-15T17:52:31.417Z Engine:NOTICE Starting reaction Message Test (re-l37h2fkj)
[latest-22004]2022-05-15T17:52:31.417Z Engine:INFO Message Test all actions completed.
[latest-22004]2022-05-15T17:52:31.704Z Engine:INFO Enqueueing "Message Test" (re-l37h2fkj)
[latest-22004]2022-05-15T17:52:31.735Z Engine:NOTICE Starting reaction Message Test (re-l37h2fkj)
[latest-22004]2022-05-15T17:52:31.736Z Engine:INFO Message Test all actions completed.
[latest-22004]2022-05-15T17:52:32.007Z Engine:INFO Enqueueing "Message Test" (re-l37h2fkj)
[latest-22004]2022-05-15T17:52:32.035Z Engine:NOTICE Starting reaction Message Test (re-l37h2fkj)
[latest-22004]2022-05-15T17:52:32.036Z Engine:INFO Message Test all actions completed.
[latest-22004]2022-05-15T17:52:41.324Z Engine:INFO Enqueueing "Variable Telegram Test" (re-kvnm57c3)If I use the following in my web browser the telegram message gets through:
https://api.telegram.org/botxxxxx......./sendMessage?chat_id=xxxxx......&text=Test Message HTTPS
I am running MSR on my QNAP network attached storage. Any assistance would be appreciated.
Just another question...... I would like to post in the HOME HARDWARE VERA section of Smarthome, but I do not have the option to set up a new post. Do I need to request access for this?
-
I've just started to look at HASS UI, and have seen enough to see that it has an infinite number of ways to show enitites and devices in all forms and shapes.. But for starters i'd like to have something familiar, so how do i go about getting a sidebar for rooms like in openluup?
I know i can put them in the actual left sidebar, but i'd prefer to keep that for configuration pages..
on each room page i'd like to sort the lights, the heaters, the sensors together, and i saw somewhere that HASS will do that for you if you play your cards (pun) right.. can't find it again now..
Any pointers to a beginner?
-
Details of runtime environment:
Reactor (Multi-hub) stable-22055-9b40e12 Running as a service on Windows Server 2022 Std 21H2 Connecting to HASS (HASSOS) Is a migration WIP from OpenLuup/ReactorA complete description of your objective:
Using LetsEncrypt, application "certifyTheWeb", retrieve and apply SSL certificate to Multi System ReactorA description of your approach/solution/implementation so far:
Reviewed Config files, can't seen mention of certificate files in thereActual Question:
How do I apply a certificate to whatever web server Reactor uses? I'm familiar with managing certificates on IIS and Apache but Reactor doesn't use either of these and I have not been able to locat ethe config file that Reactor uses for this. Which config file needs editing to apply a certificate? Does it use the computer certificate store or it's own store (e.g. pem files)The reason I want to achieve this, other than the general goodness of having everything I can in TLS is that I have Reactor as an IFRAME in my HASS console and as HASS is HTTPS and Reactor is HTTP then the iframe refuses to open.
Search for "certificate" or "ssl" did not reveal anything relevant in this forum.
-
@toggledbits
Hi Patrick,
Running HASS 2022.5.3
MSR zwavejs-22126-834c3e9Seeing weird behavior in MSR with regards to my Zen32's. Not sure how to capture info that might be relevent but will describe what I am seeing.
In the example below I pressed scene 001 4 times. It flashed and changed the primary value to "4". The remaining buttons were previously showing the PV as "double" I pushed each button one time and they flashed and displayed the PV as 4.
zen32.JPGIn the zwavejs2mqtt debug screen that sequence looks like this.
2022-05-10 09:38:44.078 INFO ZWAVE: Node 45: value notification: 91-0-scene-001 5 2022-05-10T16:38:44.081Z CNTRLR « [Node 045] received CentralScene notification { "nodeId": 45, "ccId": "Central Scene", "ccCommand": "0x03", "payload": "0x898501" } 2022-05-10 09:38:45.982 INFO ZWAVE: Node 45: value notification: 91-0-scene-002 0 2022-05-10T16:38:45.984Z CNTRLR « [Node 045] received CentralScene notification { "nodeId": 45, "ccId": "Central Scene", "ccCommand": "0x03", "payload": "0x8a8002" } 2022-05-10 09:38:47.807 INFO ZWAVE: Node 45: value notification: 91-0-scene-003 0 2022-05-10T16:38:47.810Z CNTRLR « [Node 045] received CentralScene notification { "nodeId": 45, "ccId": "Central Scene", "ccCommand": "0x03", "payload": "0x8b8003" } 2022-05-10 09:38:48.858 INFO ZWAVE: Node 45: value notification: 91-0-scene-004 0 2022-05-10T16:38:48.861Z CNTRLR « [Node 045] received CentralScene notification { "nodeId": 45, "ccId": "Central Scene", "ccCommand": "0x03", "payload": "0x8c8004" }Let me know what other info you would like me to supply.
I have played around with a bunch of other key stroke combo's and it looks like buttons 2-5 display what ever button 1 is set to.
Have tested this on 4 different ZEN32's and it is same on all. -
Running zwavejs-22118-baab576 in MSR, HASSOS 2022.5.1
Due to an unreported issue in HASS, when I upgraded the 2022.5 yesterday, it dropped ZwaveJS2MQTT from my HASSOS build. Finally got it reinstalled and it appears to be working the way it was previously.
MSR is now showing zwavejs down and in entities, nothing is updating.Seeing this in the logs:
ZWaveJSController#zwavejs ws_open caught [Error]Error: connect ECONNREFUSED 192.168.0.16:3000Are there additional steps needed that are not mentioned in the manual?
At a loss to figure out what is causing issue. -
....but not what you think, probably.
I doubt there's an answer here to this, and it's about Iphone locator (sorry!)
Hopefully the question is, at least, slightly interesting.
Polling on the phone is currently set to 5 minutes and IPhone locator appears to update every 5 minutes as I also get an update in the OpenLuup log every 5 minutes.
The 'problem' is that the Iphone locator (and therefore any conditions based upon a change in value) are happening 4 minutes and some seconds after the phone polls and updates its position. So effectively the phone is moving for nearly 10 minutes before any notification takes place. Which is a bit slow for my desired application.
As an example:
2022-05-05 17:27:08.244 luup.variable_set:: 55.urn:upnp-org:serviceId:IPhoneLocator1.MsgText2 was: 28.35 Km @ 0.00 Km/h on 2022-05-05 17:17 now: 28.35 Km @ 0.00 Km/h on 2022-05-05 17:22 #hooks:0 2022-05-05 17:32:12.340 luup.variable_set:: 55.urn:upnp-org:serviceId:IPhoneLocator1.MsgText2 was: 28.35 Km @ 0.00 Km/h on 2022-05-05 17:22 now: 27.77 Km @ 6.92 Km/h on 2022-05-05 17:27 #hooks:0Where you can see that the phone must have updated its location between 17:27:08.244 and 17:28:00.000
Anyone got an bright ideas how I can reduce the discrepency?
Cheers!
C
-
Hi!
After several tests, restarting the computer where the MSR is, and the MSR itself by Tools > Restart, I have a persistent error in the logs.
32d45bc3-51f8-4718-a113-3381e9d7edf2-image.png
Looking at the global expression (screen below), I see that it is highlighted as an error, however, if I look at two other expressions above that have the same structure, they do not present an error, so I do not think the problem is with the expression's code.
ca8a7867-4ac7-4f9a-9913-15a80da18f05-image.png
This expression uses a group, which validates 4 devices of type door sensor, whether the status is true or false, door open or closed.
"dgc_entrance_open": name: DGC Entrance Open select: - include_entity: - "hubitat>37" - "hubitat>38" - "hubitat>99" - "hubitat>130" filter_expression: > entity.attributes?.door_sensor?.state == trueI also compared it with other groups, the structure is identical.
Looking at the 4 devices in this group, I see that all are active in the MSR, have similar variables, are used in other groups and rules that do not present a problem.
52b099f4-b9c4-46cb-ad3d-c873b09b7e13-image.png
Looking at the log, I understand that it refers to some object that would be null, at which point I am lost on what to actually look at.
[latest-22118]2022-05-02T22:33:11.711Z <Engine:INFO> Reaction Engine starting [latest-22118]2022-05-02T22:33:11.719Z <Engine:INFO> Checking rule sets... [latest-22118]2022-05-02T22:33:11.746Z <Engine:INFO> Checking rules... [latest-22118]2022-05-02T22:33:11.748Z <Engine:INFO> Data check complete; no corrections. [latest-22118]2022-05-02T22:33:11.892Z <Engine:ERR> [Engine]Engine#1: error evaluating expression EntranceOPEN: [ReferenceError]ReferenceError: Invalid scope in reference to member attributes of (object)null [latest-22118]2022-05-02T22:33:11.893Z <Engine:ERR> [Engine]Engine#1: expression: sort(each id in ( getEntity('groups>dgc_entrance_open').attributes.sys_group.members ): getEntity(id).name) [latest-22118]2022-05-02T22:33:11.894Z <Engine:CRIT> ReferenceError: Invalid scope in reference to member attributes of (object)null ReferenceError: Invalid scope in reference to member attributes of (object)null at _run (C:\MSR\reactor\common\lexp.js:1449:31) at _run (C:\MSR\reactor\common\lexp.js:1443:33) at _run (C:\MSR\reactor\common\lexp.js:1443:33) at _run (C:\MSR\reactor\common\lexp.js:1536:38) at _run (C:\MSR\reactor\common\lexp.js:1480:33) at C:\MSR\reactor\common\lexp.js:1283:29 at Array.forEach (<anonymous>) at _run (C:\MSR\reactor\common\lexp.js:1282:28) at run (C:\MSR\reactor\common\lexp.js:1663:22) at Object.evaluate (C:\MSR\reactor\common\lexp.js:1699:20) [latest-22118]2022-05-02T22:33:12.232Z <Engine:NOTICE> Reaction Engine running! [latest-22118]2022-05-02T22:33:12.233Z <Rule:INFO> Rule#rule-kxjp2el2 (Mode DAY) started [latest-22118]2022-05-02T22:33:12.234Z <Rule:INFO> Rule#rule-kxjp7kc8 (Mode EVENING) started [latest-22118]2022-05-02T22:33:12.234Z <Rule:INFO> Rule#rule-kxjparz7 (Mode NIGHT) started [latest-22118]2022-05-02T22:33:12.234Z <Rule:INFO> Rule#rule-kxjpd0d6 (Mode AWAY ∆) started [latest-22118]2022-05-02T22:33:12.235Z <Rule:INFO> Rule#rule-kxjqrcr9 (Mode PARTY) started [latest-22118]2022-05-02T22:33:12.235Z <Rule:INFO> Rule#rule-kxjqyhnu (Mode VACATION ∆) startedFinally, if I return the expression and press the Try This Expression button, it is executed and the error disappears.
102e5013-b9aa-4c26-98f5-1ae545f8897f-image.png
This situation started to occur on the latest version of Reactor 22118, on a Windows 10 Bare Metal installation. Does anyone have a similar scenario?
Sorry for the long post, I tried to document as best as possible to try to identify the problem.
Thanks.
-
Please can anyone give me advice on a cheap way to run MSR (both initial cost and ongoing electricity cost). I currently run it on my QNAP network drive (which works very well incidentally). However, this draws a constant 35Watts (£90/yr @ 30p/kWh) and given the recent rise in fuel costs I am evaluating the best way forwards. Note, I only really need to turn my QNAP on for an hour a week to back-up my computer data. I understand that MSR can run on a Raspberry PI, but I am not competent with Linux! Thanks.
-
I just noticed that the new hotness picked up the entities from when I added an integration temporarily to my Home Assistant and popped a lovely info notice into the Alerts pane.
I know the info is new - but when did MSR suddenly become more real-time with devices being added to hubs? This is great!
-
Noticed in the last few nights that my Global Reaction to turn on a mere six lights in the evenings the same two devices no longer turn on. One is a dimming smart bulb, the other is a wall outlet.
This has been running flawlessly for months - just in the last few nights I've noticed these two devices being left behind and yes, it's always these two devices only.
"What changed?"
No Hubitat firmware updates No new devices added to Hubitat list itemTwo MSR updates (the last two, I keep up with the latest) list itemHome Assistant releases (should have zero bearing, HA is nothing more than pretty dashboards) list itemAdded MQTT to MSRI did do a z-wave "repair" last night and am waiting to see if this helps.
Is there any maximum or cap on number of devices that should be included in a Global Reaction?
*Marked as solved as the question asked was answered. The issue persists but the question was answered.
-
I've borked my install of reactor-latest-22118-0f0772c.tar.gz for some reason and am retracing steps. Running npm i --no-save --omit dev prompted to update npm and I did (current version now 8.6.0). Currently, attempts to load via browser/s (Brave and Safari) result in "This site can’t be reached192.168.1.xxx refused to connect." I am still able to SSH into the RPi.
I haven't panicked yet but did just pull my config and storage directories - I believe I read where that's enough for a back-up if a clean install ends up being needed.
So the question of the day: which version of nmp should we be running on for the latest Reactor?
-
I’ve looked and can’t find the answer which concerns me that the answer is obvious and thats why I can't find the answer to this.
I’m new to MSR and this is my first post, so please bare with me 🙂
What I’m trying to do is have a global expression that contains the current time so I can use it in Global reactions as well as Rulesets as part of my syslog messages.
Example of what I’m experiencing:
In Expressions, create a global expression: gMyTOD = strftime("%T %D”)
In Rulesets, in a rule, create a local expression: MyTOD = strftime("%T %D”)In that same rule create a Notify type of Syslog.
Set syslog message to: gMyTOD time is ${{gMyTOD}} and MyTOD time is ${{MyTOD}}
Trigger the rule.The result is that the local expression (MyTOD) contains the correct time but the global expression (gMyTOD) does not update and reflects the wrong time in the final syslog message.
Is there a different approach I should be using?
Thank you in advance for any insight.
-bh
-
Hi!
What's the easiest and most effective way to make this work? Do I ping a few websites every ten minutes or so, or is there a better approch? If I'm going to ping, what URL is recommended?
Once a month or so, my internet access is lost, and I have to cut the power to the router, to restart it. When I'm away this become a problem, so I thought that if I got a zigbee switch (in Home Assistant), problem is solved. But how do I (MSR) know if it's offline?For information, I have a set up with Asus routers, Home Assistent with zigbee-, z-wave and wifi devices (a total of appr. 150) and every of my 60-70 automation is done by MSR.
I run MSR ver. 22080-ae7212f (docker on my Home Assistant blue). HA ver 2022.4.6.
Thanks in advance.
Take care, you all!
/Fanan -
FYI.
Recently a new ALTUI version got pushed out, release 2553. After the update Reactor is no longer showing any of the Control panels in a sensor. looking at the ALTUI changes they seem minimal so in J_ReactorSensor_UI7.js I upped the _MAX_ALTUI_VERSION to 2553 and all seems to be working again.
-
-
So, I have a rule set that it's triggered when a local variable changes. Since it's tied to my solar production, it could change very frequently, so I've just added a reset delay to calm it down, but it's not working as intended.
What I really need is a way to, let's say, define a percentage and define a variable to understand if the new value has changed +/- 10% before going true.
I've tried a couple of ways, but I'm posting here anyway, in case anyone has found a better way to tackle this. Thanks!
-
Perhaps a dumb question. Can I check from Home Assistant that MSR is up and running? I would like to see that in a status page in HA. I can of course ping the other Pi but it doesn't say anything about the MSR status.
-
@toggledbits Is there a way to get Current Alerts as an entity so I could monitor those and send notifications if needed.
My usecase is sometimes openLuup crashes and MSR picks that up pretty quick, sending a pushover notification to me would get my attention to restart it.
Of course there are many ways to monitor connectivity but since MSR already is doing that it would be neat to take advantage of it.
Best posts made by Edwin1972
-
RE: VeraBridge not auto connected after reboot Pi4
Thanks, it works!!
sudo raspi-config
3 Boot Options
B2 Wait for Network at Boot
select 'YES' -
RE: system capability zwave_scene_controller
Thanks for the quick response. It works!
-
RE: Plugin Switchboard : Virtual Switch in VeraPlus not shown in Openluup
I changed the connection to ethernet but the problem is not resolved. It takes sometimes over 60 minutes or even more to reconnect with openluup or alui via IP; 3480. I have ordered a new micro DS card and I restore my RP4 backup. I hope the problem may be solved.
The strange thing is that node red server can be reached when openluup is not available.
-
RE: Plugin Switchboard : Virtual Switch in VeraPlus not shown in Openluup
It looks like the problem has been resolved. It turned out to be the Honeywell plugin that caused problems. Honeywell's server was unreachable. Honeywell plugin on google home did not work either. Now everything works perfectly . Thanks everyone for the help
-
RE: TimeStamp variable in MSR
Thanks for the quick response! I'm going to try to use it in my logic
-
RE: calculate with MSR variables in LuaXP
@toggledbits My explanation of my project
I use somfy motors (rfx) to open and close my roman blinds electrically. I can control this via RFXtrx433E USB Transceiver connect to my Vera. RFX gives no feedback so I can only open and close them and not moving them to a position based on the percentage of the slider. The RFX plugin (Tinmann) works with a slider related on MaxMoveTime (time to go from completely open to completely close)., but it doesn’t work with somfy. So I started my own project.
I have installed the switchboard plugin on my Vera. I have created a virtual switch (virtual window coverings) and use it in MSR to close my blinds with the slider based on MaxMoveTime (time to go from completely open to completely close). It works with Vera and also with voice control by google home.
MRS setting:
Expression : LoadLevel_Last_Oost, MaxMoveTime_OostWhat I haven't solved yet is the following:
I can operate Romand blinds by MSR with time schedule but would like to operate Roman blinds manually with the fibaro roller shutter 2, double click down / up and triple click stop function. For example, with a double click function I can start the following action:I am using the virtual window covering (Switchboard) and switching up (double click Up), down (double click down) and stop (Triple click down). Switchboard can simulate motor movement of the covering by ramping LoadLevelStatus at a rate of XX% per second to the target value. This is the problem.
MaxMoveTime (time to go from completely open to completely close) = 40 sec. Switchboard simulate motor movement = 34 sec (RampRatePerSecond =2).To set simulate motor movement =40 seconds, RamRatePerSeconde should be = 2.35. This does not work because they must be integer number. Is there a possibility to set the MaxMoveTime to simulate motor movement instead of movement % per sec?
-
RE: calculate with MSR variables in LuaXP
@toggledbits
Yes, it works! Excellent.
Thank you for your time! Now I can continue my project. The new variable is also useful.
Latest posts made by Edwin1972
-
RE: Using Hikvision HTTP API request with MSR
I haven't found the time yet to fix MSR. I think there is something wrong with NPM. Node Red can't update some plugins either.
Is it also possible to use the function in a reactor (openluup)?
-
RE: Using Hikvision HTTP API request with MSR
@toggledbits I have updated MSR to latest-21258-6fb388e but still get the same error
-
RE: Using Hikvision HTTP API request with MSR
Thanks for the quick response. I'm playing with it but I get an error when input expression.
@toggledbits Is this due to the prerelease MSR? I am using version (pre-release) 0.1-21096. I haven't upgraded to new version yet -
Using Hikvision HTTP API request with MSR
I have a Hikvision camera for a month and have been playing with it. Now I read a post of cw-kid (post : System integration roadmap) that you can control the camera by HTTP API request. That's cool if that also will work for me. Can someone explain what to enter in MSR for HTTPS request command to do so. (Marked red arrows)
I want to turn the smart supplement light on and off at a specific time. Now I do that with scheduled switch, but it is better to control that with sunrise and sunset function with MSR. I'm curious how it works.
-
RE: MSR http PUT error
@whyfseeguy I also have a Hikvision camera since a month and I'm playing with it. Now I read your post that you can set a variable remotely through ISAPI. That would be cool. Could you explain how you can do that with MSR. I want to turn the smart supplement light on and off at a certain hour. Now I do that with scheduled switch but it's better with sun rise and sun set with logic MSR
-
RE: Use Scenes (2x/ 3x click) from Fibaro Roller Shutter 2 in openluup with zway bridge
@rafale77
I overwritten the L_ZWay2.lua file. De Z-way bridge does its job. The devices gives reaction (ON/OFF) but bridge gives no update of Remote_2-0-0-14-S, Remote_2-0-0-24-S or Remote_2-0-0-25-S -
RE: Use Scenes (2x/ 3x click) from Fibaro Roller Shutter 2 in openluup with zway bridge
@rafale77
I overwritten the L_ZWay2.lua file (keep the old one) on my PI4. The z-way bridge does not give an error, but the switches no longer respond in openluup. After the old file has been restored, they will work again. -
RE: calculate with MSR variables in LuaXP
@toggledbits
Yes, it works! Excellent.
Thank you for your time! Now I can continue my project. The new variable is also useful. -
RE: calculate with MSR variables in LuaXP
Thanks! I have installed version 21098 on my vera and I entered 2.5 but it returns the same as 2. With stopwatch about 50 sec.
-
RE: calculate with MSR variables in LuaXP
@toggledbits My explanation of my project
I use somfy motors (rfx) to open and close my roman blinds electrically. I can control this via RFXtrx433E USB Transceiver connect to my Vera. RFX gives no feedback so I can only open and close them and not moving them to a position based on the percentage of the slider. The RFX plugin (Tinmann) works with a slider related on MaxMoveTime (time to go from completely open to completely close)., but it doesn’t work with somfy. So I started my own project.
I have installed the switchboard plugin on my Vera. I have created a virtual switch (virtual window coverings) and use it in MSR to close my blinds with the slider based on MaxMoveTime (time to go from completely open to completely close). It works with Vera and also with voice control by google home.
MRS setting:
Expression : LoadLevel_Last_Oost, MaxMoveTime_OostWhat I haven't solved yet is the following:
I can operate Romand blinds by MSR with time schedule but would like to operate Roman blinds manually with the fibaro roller shutter 2, double click down / up and triple click stop function. For example, with a double click function I can start the following action:I am using the virtual window covering (Switchboard) and switching up (double click Up), down (double click down) and stop (Triple click down). Switchboard can simulate motor movement of the covering by ramping LoadLevelStatus at a rate of XX% per second to the target value. This is the problem.
MaxMoveTime (time to go from completely open to completely close) = 40 sec. Switchboard simulate motor movement = 34 sec (RampRatePerSecond =2).To set simulate motor movement =40 seconds, RamRatePerSeconde should be = 2.35. This does not work because they must be integer number. Is there a possibility to set the MaxMoveTime to simulate motor movement instead of movement % per sec?