I'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only).
Anyway, here's my reactor-mqtt-contrib package:
Contrib MQTT templates for Reactor. Contribute to dbochicchio/reactor-mqtt-contrib development by creating an account on GitHub.
Simply download yaml files (everything or just the ones you need) and you're good to go.
I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them.
The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression.
Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests 🙂
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.Hi @toggledbits.
After a couple of weeks, I noticed that my Remotec zrc90 isn't working as expected.
Scenes are working in ZWaveJS, but this device has a strange behavior: the scene change, but then it's set again to null. In Reactor, this remains null:
battery_power.level=0.7 battery_power.since=1725817957361 x_debug.dt={"description":"Scene master 8 button remote","model":"BW8510/ZRC-90US","default_name":"Scene master 8 button remote","manufacturerId":21076,"productType":0,"productId":34064} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=70 x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_scene_003=null x_zwave_values.Central_Scene_scene_004=null x_zwave_values.Central_Scene_scene_005=null x_zwave_values.Central_Scene_scene_006=null x_zwave_values.Central_Scene_scene_007=null x_zwave_values.Central_Scene_scene_008=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Manufacturer_Specific_manufacturerId=21076 x_zwave_values.Manufacturer_Specific_productId=34064 x_zwave_values.Manufacturer_Specific_productType=1 x_zwave_values.Version_firmwareVersions=["1.1","1.1"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=2 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=0 zwave_device.capabilities=[91,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Remote Controller" zwave_device.impl_sig="24242:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=false zwave_device.is_secure=false zwave_device.manufacturer_info=[21076,1,34064] zwave_device.max_data_rate=null zwave_device.node_id=154 zwave_device.specific_class="Simple Remote Control" zwave_device.status=2 zwave_device.status_text="awake" zwave_device.version_info=[null,"1.1"] zwave_device.wakeup_interval=0Anything I could look at? Thanks.
Hi, @toggledbits!
I have a question about the execution behavior. See the code below, and I'll explain the situation.
12957c3e-ff06-46c9-929d-b53f936665df-image.png
This is a routine that, at a certain point, determines that the desktop on which the VM hosting the Reactor is located receives an instruction to perform a shutdown (Shell Command).
When this happens, the desktop is turned off, and then Hubitat detects by a "ping" that the VM has been down, waits 15 seconds, turns off the power to this desktop, and then 15 seconds later turns on the desktop with the Reactor VM again.
After restarting the desktop, the VM is loaded, and the Reactor is triggered. Still, the following problem occurs: I expected that when the rule was continued to be executed again, the next step would be executed, that of the 900-second delay after shutdown, but the Shell command is executed again, and then it goes into a loop, the rule does not advance.
To break the loop, I first have to make the VM not load, change the desktop password, and then start the VM. In this case, Reactor generates an error when trying to execute the Shell Command because of the invalid password and then finishes the routine following the 900 delay step.
b58b0d4a-d6c1-4fe3-bab7-4222acea9607-image.png
Is my interpretation that when it returns, the routine should continue to the next step that has not yet been executed incorrectly? Or does Reactor, through the shutdown command, interpret that it hasn't finished this step and keep trying, which is the correct reaction?
Thanks for clarifying.
Hi @toggledbits ,
I'm slowly moving my ZWave network from Vera to ZWaveJS. I successfully cloned my ZWave network using a spare Vera Edge (a new post for the community later when I'll be fully back from vacation) and I'm testing a couple of things before moving everything to ZWaveJS.
In the meanwhile, I have a couple of venetian blinds connected to Fibaro Roller Shutters 2 (FGR222) and I'm using some proprietary ZWave commands to control the tilt position, that right now I'm sending via Vera (with some code from the old place, messing with this):
af7f883c-f49e-419c-a2fe-8669572e3792-image.png
The ZWaveJS values are reported via this:
x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsPosition=0 x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsTilt=0I hope there's a way to expose a separate device to control the tilt position directly, without doing the mess I'm doing now. Let me know if you need some files. Thanks.
As per @toggledbits request, new topic.
Position and cover commands not working and position/cover attributes are incorrect. Dimming is OK.
cover.state=null dimming.level=1 dimming.step=0.1 energy_sensor.units="kWh" energy_sensor.value=0.41 position.value=null power_sensor.units="W" power_sensor.value=0 power_switch.state=true x_debug.dt={"entity_class":"Cover","match":"deviceClass.generic.key=17;deviceClass.specific.key=6","capabilities":["cover","toggle","position"],"primary_attribute":"cover.state"} x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.41 x_zwave_values.Meter_value_66049=0 x_zwave_values.Multilevel_Switch_Down=null x_zwave_values.Multilevel_Switch_Up=null x_zwave_values.Multilevel_Switch_currentValue=99 x_zwave_values.Multilevel_Switch_duration="unknown" x_zwave_values.Multilevel_Switch_restorePrevious=null x_zwave_values.Multilevel_Switch_targetValue=99 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_System_Hardware_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null zwave_device.capabilities=[38,50,113] zwave_device.endpoint=1 zwave_device.failed=null zwave_device.impl_sig="24225:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=148 zwave_device.version_info=nullThanks!
Another one for you, @toggledbits.
I have two water sensors (same device, NAS-WS01Z), but one is reporting leak_detector.state=true even if no alarm is detected (I double checked from ZWaveJS UI):
battery_power.level=0.86 battery_power.since=null leak_detector.state=true x_debug.dt={"entity_class":"Notification Sensor","match":"deviceClass.generic.key=7"} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=86 x_zwave_values.Binary_Sensor_Water=false x_zwave_values.Configuration_Alarm_Activity_Duration=5 x_zwave_values.Configuration_Alarm_Beep=1 x_zwave_values.Configuration_Alarm_Duration=120 x_zwave_values.Configuration_Alarm_Interval=null x_zwave_values.Configuration_Basic_Set_Level=255 x_zwave_values.Configuration_First_Alarm_Activity_Duration=null x_zwave_values.Configuration_Water_Detection=1 x_zwave_values.Manufacturer_Specific_manufacturerId=600 x_zwave_values.Manufacturer_Specific_productId=4229 x_zwave_values.Manufacturer_Specific_productType=3 x_zwave_values.Notification_Water_Alarm_Sensor_status=null x_zwave_values.Notification_alarmLevel=0 x_zwave_values.Notification_alarmType=0 x_zwave_values.Version_firmwareVersions=null x_zwave_values.Version_hardwareVersion=null x_zwave_values.Version_libraryType=null x_zwave_values.Version_protocolVersion=null x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=43200 zwave_device.capabilities=[48,112,113,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Notification Sensor" zwave_device.impl_sig="24225:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.last_wakeup=1724143899220 zwave_device.manufacturer_info=[600,3,4229] zwave_device.max_data_rate=null zwave_device.node_id=114 zwave_device.specific_class="Notification Sensor" zwave_device.status=1 zwave_device.status_text="asleep" zwave_device.version_info=[null,null] zwave_device.wakeup_interval=43200here's the other one, correctly report the leak status:
battery_power.level=1 battery_power.since=null leak_detector.state=false x_debug.dt={"entity_class":"Notification Sensor","match":"deviceClass.generic.key=7"} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=100 x_zwave_values.Binary_Sensor_Water=false x_zwave_values.Configuration_Alarm_Activity_Duration=5 x_zwave_values.Configuration_Alarm_Beep=1 x_zwave_values.Configuration_Alarm_Duration=120 x_zwave_values.Configuration_Alarm_Interval=1 x_zwave_values.Configuration_Basic_Set_Level=255 x_zwave_values.Configuration_First_Alarm_Activity_Duration=60 x_zwave_values.Configuration_Water_Detection=1 x_zwave_values.Manufacturer_Specific_manufacturerId=600 x_zwave_values.Manufacturer_Specific_productId=4229 x_zwave_values.Manufacturer_Specific_productType=3 x_zwave_values.Notification_Water_Alarm_Sensor_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null x_zwave_values.Version_firmwareVersions=["2.54"] x_zwave_values.Version_hardwareVersion=48 x_zwave_values.Version_libraryType=6 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=43200 zwave_device.capabilities=[48,112,113,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Notification Sensor" zwave_device.impl_sig="24225:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.last_wakeup=1724105239533 zwave_device.manufacturer_info=[600,3,4229] zwave_device.max_data_rate=null zwave_device.node_id=113 zwave_device.specific_class="Notification Sensor" zwave_device.status=1 zwave_device.status_text="asleep" zwave_device.version_info=[null,"2.54"] zwave_device.wakeup_interval=43200Also, both seems to have no primary value. Thanks.
Good morning,
I have a service MQTT service that needs a restart occasionally. The add-on (Smartbed MQTT) is for the smart bed base for my bed. It has a "safety light" that I can control from HAAS & MSR as a light entity, and also moves the head of the bed to a preset at bedtime, and then lies it back flat in the morning The problem is, from time to time, the light becomes "unavailable" Restarting from the Add-ons tab in HAAS always fixes it, but I should be able to detect when it happens when "light.tempur_pedic_safety_lights" is not true or false, i.e., unavailable.
What I don't know how to do is how to restart that service. Does anybody have experience in restarting add-ons from MSR?
Running:
Reactor (Multi-hub) latest-24212-3ce15e25 ZWaveJSController [0.1.24232]HAAS:
RPi5-64 (8GB) Core 2024.7.3 Supervisor 2024.08.0 Operating System 13.0 Frontend 20240710.0Hi-
I have an android media player entity publishing from HA. I watch for changes in transport state and media title to trigger some actions.
Though those attributes report as expected, the set rule is being throttled for possible flapping.
There is an attribute for media position that continually updates, I suspect it is causing the evaluations to run constantly.
The workaround I am seeking is to ignore those attributes in HA or MSR. Anyone know how, or have a better idea??
Thx
Btw- this problem has spanned versions of HA and reactor, but I am current on both. Too current on HA for transparency, but the issue has survived several updates.
Referencing an expression inside a reaction is in the form of ${{ expression }}. When referenced inside my shell command to set the watering delay duration for my Rachio sprinkler system, it just does not work.
If I enter "86400" instead of referencing the expression lWateringDelayDuration, it works. Either I am doing something wrong or referencing an expression inside a shell command is not supported.
Reactor version: 24212
Local Expression
lWateringDelayDuration =
Setting Reaction using Shell command
curl -X PUT -H "Content-Type: application/json" -H "Authorization: Bearer xxxxxxxxxx -d '{ "id" : "xxxxxxxxxx", "duration" : ${{ lWateringDelayDuration}} }' https://api.rach.io/1/public/device/rain_delayThanks in advance
As per @toggledbits request, here's a new topic.
My Fibaro Door Window Sensor 2 (FGDW002) is always reporting as open, even if
x_zwave_values.Notification_Access_Control_Door_state=23 x_zwave_values.Notification_Access_Control_Door_state_simple=23which means that the door is closed. It was working before and I could downgrade to test, if necessary. Thanks.
Hi @toggledbits,
I'm not sure if it's a bug or something, but I have a lot of Fibaro Double Switch (FGS223) as follows.
In the example, it's zwavejs>65-2:
energy_sensor.units="kWh" energy_sensor.value=0.21 power_sensor.units="W" power_sensor.value=0 power_switch.state=false x_debug.dt={"entity_class":"Switch","match":"deviceClass.generic.key=16","capabilities":["power_switch","toggle"],"primary_attribute":"power_switch.state"} x_zwave_values.Binary_Switch_currentValue=false x_zwave_values.Binary_Switch_targetValue=false x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.21 x_zwave_values.Meter_value_66049=0 zwave_device.capabilities=[37,50] zwave_device.endpoint=2 zwave_device.failed=null zwave_device.impl_sig="23326:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=65 zwave_device.version_info=nullWhen operating endpoint 2, it's triggered endpoint 1. Endpoint 1 is fine. This is causing a lot of troubles, as you may imagine.
Also, endpoint 0 is not really a switch, and the associated actions are not doing anything at all. Maybe these could be removed. Also, I see battery_maintenance and power_source capabilities, all with null values.
battery_maintenance.charging=null battery_maintenance.rechargeable=false battery_maintenance.replace=false battery_maintenance.state=null heat_detector.state=false power_source.source=null power_switch.state=null x_debug.dt={"entity_class":"Switch","match":"deviceClass.generic.key=16","capabilities":["power_switch","toggle"],"primary_attribute":"power_switch.state","description":"Double Switch 2","model":"FGS223","default_name":"Double Switch 2","manufacturerId":271,"productType":515,"productId":4096} x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Configuration_First_Channel_Energy_Reports_Threshold=100 x_zwave_values.Configuration_First_Channel_Operating_Mode=0 x_zwave_values.Configuration_First_Channel_Power_Reports_Minimum_Time_Between_Reports=10 x_zwave_values.Configuration_First_Channel_Power_Reports_Threshold=20 x_zwave_values.Configuration_First_Channel_Pulse_Time_for_Blink_Mode=5 x_zwave_values.Configuration_First_Channel_Reaction_to_Key_S1_for_Delay_Auto_ON_OFF_Modes=0 x_zwave_values.Configuration_First_Channel_Time_Parameter_for_Delay_Auto_ON_OFF_Modes=50 x_zwave_values.Configuration_General_Purpose_Alarm_Response=3 x_zwave_values.Configuration_Include_Consumption_By_Device_Itself_in_Reports=0 x_zwave_values.Configuration_Input_Button_Switch_Configuration=2 x_zwave_values.Configuration_Key_S1_Associations_Double_Click_Value_Sent=99 x_zwave_values.Configuration_Key_S1_Associations_Send_OFF_With_Single_Click_2=0 x_zwave_values.Configuration_Key_S1_Associations_Send_ON_With_Single_Click_1=0 x_zwave_values.Configuration_Key_S1_Associations_Send_When_Double_Clicking_8=0 x_zwave_values.Configuration_Key_S1_Associations_Send_When_Holding_and_Releasing_4=0 x_zwave_values.Configuration_Key_S1_Associations_Switch_OFF_Value_Sent=0 x_zwave_values.Configuration_Key_S1_Associations_Switch_ON_Value_Sent=255 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Held_Down_and_Released_8=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_1_Time_1=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_2_Times_2=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_3_Times_4=1 x_zwave_values.Configuration_Key_S2_Associations_Double_Click_Value_Sent=99 x_zwave_values.Configuration_Key_S2_Associations_Send_OFF_With_Single_Click_2=0 x_zwave_values.Configuration_Key_S2_Associations_Send_ON_With_Single_Click_1=0 x_zwave_values.Configuration_Key_S2_Associations_Send_When_Double_Clicking_8=0 x_zwave_values.Configuration_Key_S2_Associations_Send_When_Holding_and_Releasing_4=0 x_zwave_values.Configuration_Key_S2_Associations_Switch_OFF_Value_Sent=0 x_zwave_values.Configuration_Key_S2_Associations_Switch_ON_Value_Sent=255 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Held_Down_and_Released_8=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_1_Time_1=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_2_Times_2=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_3_Times_4=1 x_zwave_values.Configuration_Periodic_Active_Power_Reports=3600 x_zwave_values.Configuration_Periodic_Energy_Reports=3600 x_zwave_values.Configuration_Report_During_Blink_Mode=0 x_zwave_values.Configuration_Second_Channel_Energy_Reports_Threshold=100 x_zwave_values.Configuration_Second_Channel_Operating_Mode=0 x_zwave_values.Configuration_Second_Channel_Power_Reports_Minimum_Time_Between_Reports=10 x_zwave_values.Configuration_Second_Channel_Power_Reports_Threshold=20 x_zwave_values.Configuration_Second_Channel_Pulse_Time_for_Blink_Mode=5 x_zwave_values.Configuration_Second_Channel_Reaction_to_Key_S2_for_Delay_Auto_ON_OFF_Modes=0 x_zwave_values.Configuration_Second_Channel_Time_Parameter_for_Delay_Auto_ON_OFF_Modes=50 x_zwave_values.Configuration_Send_Secure_Commands_to_2nd_Association_Group_1=1 x_zwave_values.Configuration_Send_Secure_Commands_to_3rd_Association_Group_2=1 x_zwave_values.Configuration_Send_Secure_Commands_to_4th_Association_Group_4=1 x_zwave_values.Configuration_Send_Secure_Commands_to_5th_Association_Group_8=1 x_zwave_values.Configuration_Smoke_CO_or_CO2_Alarm_Response=3 x_zwave_values.Configuration_State_After_Power_Failure=1 x_zwave_values.Configuration_Temperature_Alarm_Response=1 x_zwave_values.Configuration_Time_of_Alarm_State=600 x_zwave_values.Configuration_Water_Flood_Alarm_Response=2 x_zwave_values.Manufacturer_Specific_manufacturerId=271 x_zwave_values.Manufacturer_Specific_productId=4096 x_zwave_values.Manufacturer_Specific_productType=515 x_zwave_values.Notification_Heat_Alarm_Heat_sensor_status=0 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null x_zwave_values.Protection_exclusiveControlNodeId=null x_zwave_values.Protection_local=0 x_zwave_values.Protection_rf=0 x_zwave_values.Protection_timeout=null x_zwave_values.Version_firmwareVersions=["3.2"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=3 x_zwave_values.Version_protocolVersion="4.5" zwave_device.capabilities=[91,112,113,114,117,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Binary Switch" zwave_device.impl_sig="23326:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=true zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.manufacturer_info=[271,515,4096] zwave_device.max_data_rate=null zwave_device.node_id=65 zwave_device.specific_class="Binary Power Switch" zwave_device.status=4 zwave_device.status_text="alive" zwave_device.version_info=[null,"3.2"]Thanks.
Good morning,
I'm having an issue with controlling my Zooz Zen14 outdoor double outlet. I should be able to control each outlet individually, and this does work when use Home Assistant (haas) from Reactor.
When I use zwavejs, I see 3 entries:
8305eccf-a99e-421f-ad18-1f08da9c8c9c-image.png
The first entry is for the overall device. I can turn both outlets on and off (in theory) by setting the power_switch state to on or off. This does turn them on and off when using zwavejs.
When I go to the individual outlets, performing the power_switch.on or power_switch.off actions turns them all (main, 1 and 2) on or off, and not just the individual outlets. When I perform the same action from haas, turning on outlet 1 will turn on the main switch and 1, but not 2.
I reviewed the logs for that node and I'm not seeing anything obvious.
:~/reactor/logs$ cat reactor.log.1 | grep ZWaveJSController#zwavejs | grep "node 216" [latest-24212]2024-08-07T00:19:00.233Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "endpoint": 0, "property": "targetValue", "newValue": true, "prevValue": false, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:00.235Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 0, "newValue": true, "prevValue": false, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:00.321Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 0, "newValue": true, "prevValue": true, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:00.322Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "targetValue", "endpoint": 0, "newValue": true, "prevValue": true, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:00.323Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:duration:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "duration", "endpoint": 0, "newValue": { "value": 0, "unit": "seconds" }, "prevValue": { "value": 0, "unit": "seconds" }, "propertyName": "duration" } } [latest-24212]2024-08-07T00:19:02.189Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 1, "newValue": true, "prevValue": false, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:02.192Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "targetValue", "endpoint": 1, "newValue": true, "prevValue": false, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:02.193Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:duration:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "duration", "endpoint": 1, "newValue": { "value": 0, "unit": "seconds" }, "prevValue": { "value": 0, "unit": "seconds" }, "propertyName": "duration" } } [latest-24212]2024-08-07T05:32:30.127Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 0 (entity "216-0") [latest-24212]2024-08-07T05:32:30.127Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 1 (entity "216-1") [latest-24212]2024-08-07T05:32:30.128Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 2 (entity "216-2")I'm running:
Reactor (Multi-hub) latest-24212-3ce15e25
ZWaveJSController [0.1.23326] (with zwavejs_data from 7/25/2024)
HA:
Core 2024.7.3
Supervisor 2024.08.0
Operating System 12.3
Frontend 20240710.0
I think this feature request could be accomplished with the use of two or more rules, but it would be great if there was a way to wait for an event or trigger to occur before continuing on in the reactions.
For example, I have a rule that will turn on some exterior lights if you arrive home after the porch lights have been turned off. Right now this rule randomly will turn off between 5-10 minutes after the person has entered the geofence. On some occasions this 5-10 minutes isn't long enough, say if you are unloading the car or something. I would like to kick off the reaction, but pause it part way through and wait for the door to close and lock, then continue it on. Hubitat Rule Machine has a "Wait for event" option, but I really want to keep all my logic within MSR.
Hi,
Running the latest version 24212 on docker.
I want to run some appliances when my solar panels deliver over 1200 watts to the net. In this example the dryer. So when the dryer is turned on, the rule starts (SET). There first is a 3 min delay in case the dryer is turned on manually, that is group "Check if auto start is needed". If the dryer is not running, the status is set to waiting, and the shown Repeat Until should wait as long the power delivered is higher than -1200 for at least 120 seconds and the status is still waiting. Higher as the value is negative. For some reason that repeat until "DR Wait for solar high or manual start" looks skipped. Nothing in the logs. What am I missing?
Reactor Automation.png (g_DryerStatus should have been "waiting" and not "running" the moment the log was captured, so that should not be the issue. Unless it takes some time for a variable to actually change?)
Cheers Rene
I have got some warnings i reactor that a rule is throttled because it update rate is over 120/minute, happens now and when with a week or two in between.
The rule monitors my house power consumption when charging my car, and if if consumption risks to kill a main fuse, it stops the charging.
Thought I was clever when I in Constraints added that my car should be located at home and charging is active, but apparantly it wasn't clever enough...
I had understand it that if Constraints isn't true, then the triggers isn't evaluated.
I have a Shelly 3EM meter that measure three channel/phases and updates every second. So just for this three channels it is 180 updates per minute...
And now when I start to take a closer look I can se in my logs that this rule is evaluated with every value change on any of the three phases...
So ~11MB of logs only goes back in time around 16 hours...🙀
So what is the best solution?
Should move my "Constraints" in an new trigger group, before my existing triggers?
Rule as it is now
e5486a1b-7c3c-4ffc-b259-beed64948f2e-image.png
Hi!
I'm wondering if it's possible now, or if it's something that can be solved in a future version, to be able to remove the entities that no longer exist and are crossed out all at once. Currently, you have to mark them one by one, which takes a lot of time. Is there any way to make this more efficient?
I'm on MSR version 24212-3ce15e25.
Thanks!
/Fanan
Low-priority GUI feedback
-
UPDATE: Seemingly resolved. Trivial. I added a "hold true for 2 seconds" on Trigger condition, the wait apparently needed in order for "turn ON" event (in Constraints) to be recognized on Vera. Funny, too, because that's the 1st action Alexa's routine issues. Lessons learned: (1) MSR's idea of synchrony is not always the same as my own; and, (2) Alexa may stutter when executing successive steps in Routines (WOW! Noticing gaps of up to 7 seconds here, sometimes Step 1 precedes Step 2, sometimes other way around!).
@toggledbits , pursuant to PR#164 (Closed), I'm unfortunately still grappling with a Rule that (SOMETIMES!) refuses to fire, even when all Conditions go TRUE virtually simultaneously. I may be the world's worst Log reader, but I think the following snippet of said Rule's evaluation process supports what I'm saying:
2021-04-13T14:43:07.810Z <Rule:5:Rule.js:749> Rule#rule-knay6sc6 dependency notification entity-changed Entity#vera>device_211 from Entity#vera>device_211 2021-04-13T14:43:07.811Z <Rule:5:Rule.js:755> Rule#rule-knay6sc6 requesting eval; entity-changed Entity#vera>device_211 2021-04-13T14:43:07.812Z <Rule:5:Rule.js:950> Rule#rule-knay6sc6 (Alexa Director (alexa)) evaluate() acquiring mutex 2021-04-13T14:43:07.813Z <Rule:5:Rule.js:954> Rule#rule-knay6sc6._evaluate() mutex acquired, evaluating 2021-04-13T14:43:07.813Z <Rule:5:Rule.js:958> Rule#rule-knay6sc6 update rate is 0/min limit 60/min 2021-04-13T14:43:07.814Z <Rule:5:Rule.js:880> Rule#rule-knay6sc6 evaluateExpressions() with 3 expressions 2021-04-13T14:43:07.815Z <Rule:5:Rule.js:970> Rule#rule-knay6sc6._evaluate() trigger state now false (was false) 2021-04-13T14:43:07.816Z <Rule:5:Rule.js:972> Rule#rule-knay6sc6._evaluate() constraints state false 2021-04-13T14:43:07.817Z <Rule:null> Rule#rule-knay6sc6 rule state now false, changed no 2021-04-13T14:43:07.936Z <Rule:5:Rule.js:749> Rule#rule-knay6sc6 dependency notification entity-changed Entity#vera>device_211 from Entity#vera>device_211 2021-04-13T14:43:07.938Z <Rule:5:Rule.js:755> Rule#rule-knay6sc6 requesting eval; entity-changed Entity#vera>device_211 2021-04-13T14:43:07.939Z <Rule:5:Rule.js:950> Rule#rule-knay6sc6 (Alexa Director (alexa)) evaluate() acquiring mutex 2021-04-13T14:43:07.940Z <Rule:5:Rule.js:954> Rule#rule-knay6sc6._evaluate() mutex acquired, evaluating 2021-04-13T14:43:07.941Z <Rule:5:Rule.js:958> Rule#rule-knay6sc6 update rate is 1/min limit 60/min 2021-04-13T14:43:07.942Z <Rule:5:Rule.js:880> Rule#rule-knay6sc6 evaluateExpressions() with 3 expressions 2021-04-13T14:43:07.943Z <Rule:5:Rule.js:970> Rule#rule-knay6sc6._evaluate() trigger state now false (was false) 2021-04-13T14:43:07.945Z <Rule:5:Rule.js:1578> cond cond6zfyayg evaluation state false->true 2021-04-13T14:43:07.946Z <Rule:5:Rule.js:1578> cond const evaluation state false->true 2021-04-13T14:43:07.947Z <Rule:5:Rule.js:972> Rule#rule-knay6sc6._evaluate() constraints state true 2021-04-13T14:43:07.948Z <Rule:null> Rule#rule-knay6sc6 rule state now false, changed no
i.e. both the Triggers and Constraints condition (one each) jump to TRUE, yet the Rule itself remains FALSE, leaving another Rule (which watches this one's state) flapping in the breeze.
Didn't wanna clutter Mantis with this, but happy to. First wanted to pass this by you here, so you could request files/evidence.
As additional background, what's supposed to happen is Alexa hears me utter a preset phrase, causing an Alexa Routine to run. It runs fine (I know because she speaks and turns on music) and performs the two steps (turning on a VS on Vera and dimming another one to a specific value), which I see go "green" in MSR. And yet, as described herein, the Rule itself just sits idle.
Thanks for any guidance here!
- LS
-
2021-04-13T14:43:07.943Z <Rule:5:Rule.js:970> Rule#rule-knay6sc6._evaluate() trigger state now false (was false).
This is saying the trigger state is false. It says that in both cases. It follows by saying the rule state is false (which is correct if the triggers are false). The constraints are indeed true, but if the triggers are false, the rule state will still be false.
-
@toggledbits said in Low-priority GUI feedback:
This is saying the trigger state is false.
Much appreciated, and sorry for the n00b question. I've spent the morning chasing down gremlins left and right surrounding this "Alexa Director" endeavor, and I give up. I inadvertently created a thicket of Franken-Rules which deserve to go back into the grave.
Think I'll stick with Virtual Switches after all, as they are far more deterministic, predictable, and UI friendly than any attempt I've made thus far to reinvent them with pure logic.
Ha ha, I was having Triggers accidentally trigger multiple Rules and then, once tightened down even further, NONE of the Rules.
I will henceforth regard the VS as a necessary resource on Vera, especially when used as an adjunct to Alexa Routines.
-
Not a n00b question at all. I'd really like to see for myself what's happening. If you still experiment with it more, crank the rule's log level to 6, and send me the results.
-
@toggledbits said in Low-priority GUI feedback:
I'd really like to see for myself what's happening. If you still experiment with it more, crank the rule's log level to 6, and send me the results.
I'm sure to fiddle around further, but intend that to happen with inconsequential test Rules rather than some of my most prized "Leaving Home", "Coming Home" level workflows.
Will advise... thx.
P.S. You may legitimately ask, "Why are you trying to avoid Virtual Switches in the first place?" Answer: Because I hate having to create them, configure them, propagate them through the Vera UI (rename, relocate, hard refresh) and again through the Alexa ecosystem (name, discover, configure in Routines, etc.). I've been searching for a quick-to-expand alternative method, one that presents itself in all four UIs (Vera, MSR, Alexa, VeraMobile) with rapid adaptability to new workflows (e.g. "Time for Doing a Puzzle") which I might in turn choose to knock down after a few days.
-
@toggledbits please excuse this umpteenth FEATURE REQUEST, but would it be possible to include "Expressions" among the items listed by the "Insert Entity Attribute Value" button? While I'm not 100% certain you intend for other Rules' variables to be "visible" in the Expressions section, if they are accessible here, then having the ability to "build" such a reference instead of by rote would be helpful.
Example:
varRuleA := 1 + varRuleB[3]
// Insert tool saves having to memorizevarRuleB
name and structure -
Just go ahead and open PRs for feature requests. For the benefit of all reading, clear description and use case are a must. I'll add them to the wish list.
-
Not many PRs being opened these days. That's why there aren't many builds. FYI, each morning I plan my work around (a) long-term tasks that are in progress (some of which are PRs that can't be fixed in a day), and (b) new PRs. I do not include discussions here in those plans.
-
I'm not sure I understand your question...
also... this is that thing... topic title is "Low priority GUI feedback", and your question is about lexpjs/expressions?
-