Good morning,
I have a service MQTT service that needs a restart occasionally. The add-on (Smartbed MQTT) is for the smart bed base for my bed. It has a "safety light" that I can control from HAAS & MSR as a light entity, and also moves the head of the bed to a preset at bedtime, and then lies it back flat in the morning The problem is, from time to time, the light becomes "unavailable" Restarting from the Add-ons tab in HAAS always fixes it, but I should be able to detect when it happens when "light.tempur_pedic_safety_lights" is not true or false, i.e., unavailable.
What I don't know how to do is how to restart that service. Does anybody have experience in restarting add-ons from MSR?
Running:
Reactor (Multi-hub) latest-24212-3ce15e25 ZWaveJSController [0.1.24232]HAAS:
RPi5-64 (8GB) Core 2024.7.3 Supervisor 2024.08.0 Operating System 13.0 Frontend 20240710.0Hi!
Is it possible to generate two additional log files, the first being the replica of what is displayed on screen by the Rule History widgets and the other with Recently Changed Entities?
And could I configure the generation of one file per day, and delete the older ones? For example, store the last 5 days?
And being more ambitious, does Windget have an icon to open these TXT files in the navigated?
Well, we're approaching Christmas, so here's my request to Santa Claus @toggledbits 🙂
Hi @toggledbits
I'm working on a controller to generate llm response from a prompt in reactor. I have http response coming thru an http request action at the moment, capturing the response inside a local variable. So, it's practically sync.
I want to create a controller, so I don't have to rely on a proxy (and have a simpler architecture), and duplicate absurd http actions, but AFAIK in the current implementation, actions are async only. But if I have multiple requests going on, I cannot be sure what it's really inside an attribute. I also thought that something like a correlation id when sending the request could be used to identity multiple responses, but I wanted to double check with you before starting with something too complicated. I also noticed that some actions in home assistant (ie forecast) are sync and I'm wondering if you have any plan or hint to address this situation. Thanks.
Thanks.
@togglebits I am curious as to why the tilt_sensor.state (primary) = NULL. I believe it should show true or false. I have to use binary_sensor.state instead in my rules.
Again, not sure if this is related to Reactor/ZwaveJSController implementation or the actual Z-Wave JS UI docker version. I have copied, below, the attributes of the tilt sensor in hopes it can help.
Thanks in advance.
Reactor version 23302
ZWaveJSController version 23254
Z-Wave JS UI version 9.3.0.724519f
zwave-js version 12.2.3
@toggledbits I have noticed after upgrading both Reactor and ZWaveJSController to version 24257 that two of my devices/entities, TILT-ZWAVE2.5-ECO and Zooz ZSE18, had their entity re-named in an unusual way and also appears to be duplicated.
Reactor version 24257
ZWaveJSController version 24257
Z-Wave JS UI version 9.18.1
zwave-js version 13.2.0
Vestibule Motion Sensor State attributes/partial screenshot of entities it created. All entities have the same attributes.
motion_sensor.state=true x_zwave_values.Notification_Home_Security_Motion_sensor_status=8 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=23 zwave_device.valueId=[113,"Notification","Home Security","Home Security","Motion sensor status","Motion sensor status"] zwave_device.version_info=nullTilt Sensor Door State and Tilt Sensor Door State Simple attributes/partial screenshot of entities it created. All entities have similar attributes with exception of x_zwave_values.Notification_Access_Control_Door_State = 22 or 23.
tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state_simple=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state_simple=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=nullI'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only).
Anyway, here's my reactor-mqtt-contrib package:
Contrib MQTT templates for Reactor. Contribute to dbochicchio/reactor-mqtt-contrib development by creating an account on GitHub.
Simply download yaml files (everything or just the ones you need) and you're good to go.
I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them.
The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression.
Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests 🙂
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.Hi @toggledbits.
After a couple of weeks, I noticed that my Remotec zrc90 isn't working as expected.
Scenes are working in ZWaveJS, but this device has a strange behavior: the scene change, but then it's set again to null. In Reactor, this remains null:
battery_power.level=0.7 battery_power.since=1725817957361 x_debug.dt={"description":"Scene master 8 button remote","model":"BW8510/ZRC-90US","default_name":"Scene master 8 button remote","manufacturerId":21076,"productType":0,"productId":34064} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=70 x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_scene_003=null x_zwave_values.Central_Scene_scene_004=null x_zwave_values.Central_Scene_scene_005=null x_zwave_values.Central_Scene_scene_006=null x_zwave_values.Central_Scene_scene_007=null x_zwave_values.Central_Scene_scene_008=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Manufacturer_Specific_manufacturerId=21076 x_zwave_values.Manufacturer_Specific_productId=34064 x_zwave_values.Manufacturer_Specific_productType=1 x_zwave_values.Version_firmwareVersions=["1.1","1.1"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=2 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=0 zwave_device.capabilities=[91,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Remote Controller" zwave_device.impl_sig="24242:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=false zwave_device.is_secure=false zwave_device.manufacturer_info=[21076,1,34064] zwave_device.max_data_rate=null zwave_device.node_id=154 zwave_device.specific_class="Simple Remote Control" zwave_device.status=2 zwave_device.status_text="awake" zwave_device.version_info=[null,"1.1"] zwave_device.wakeup_interval=0Anything I could look at? Thanks.
Hi, @toggledbits!
I have a question about the execution behavior. See the code below, and I'll explain the situation.
12957c3e-ff06-46c9-929d-b53f936665df-image.png
This is a routine that, at a certain point, determines that the desktop on which the VM hosting the Reactor is located receives an instruction to perform a shutdown (Shell Command).
When this happens, the desktop is turned off, and then Hubitat detects by a "ping" that the VM has been down, waits 15 seconds, turns off the power to this desktop, and then 15 seconds later turns on the desktop with the Reactor VM again.
After restarting the desktop, the VM is loaded, and the Reactor is triggered. Still, the following problem occurs: I expected that when the rule was continued to be executed again, the next step would be executed, that of the 900-second delay after shutdown, but the Shell command is executed again, and then it goes into a loop, the rule does not advance.
To break the loop, I first have to make the VM not load, change the desktop password, and then start the VM. In this case, Reactor generates an error when trying to execute the Shell Command because of the invalid password and then finishes the routine following the 900 delay step.
b58b0d4a-d6c1-4fe3-bab7-4222acea9607-image.png
Is my interpretation that when it returns, the routine should continue to the next step that has not yet been executed incorrectly? Or does Reactor, through the shutdown command, interpret that it hasn't finished this step and keep trying, which is the correct reaction?
Thanks for clarifying.
Hi @toggledbits ,
I'm slowly moving my ZWave network from Vera to ZWaveJS. I successfully cloned my ZWave network using a spare Vera Edge (a new post for the community later when I'll be fully back from vacation) and I'm testing a couple of things before moving everything to ZWaveJS.
In the meanwhile, I have a couple of venetian blinds connected to Fibaro Roller Shutters 2 (FGR222) and I'm using some proprietary ZWave commands to control the tilt position, that right now I'm sending via Vera (with some code from the old place, messing with this):
af7f883c-f49e-419c-a2fe-8669572e3792-image.png
The ZWaveJS values are reported via this:
x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsPosition=0 x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsTilt=0I hope there's a way to expose a separate device to control the tilt position directly, without doing the mess I'm doing now. Let me know if you need some files. Thanks.
As per @toggledbits request, new topic.
Position and cover commands not working and position/cover attributes are incorrect. Dimming is OK.
cover.state=null dimming.level=1 dimming.step=0.1 energy_sensor.units="kWh" energy_sensor.value=0.41 position.value=null power_sensor.units="W" power_sensor.value=0 power_switch.state=true x_debug.dt={"entity_class":"Cover","match":"deviceClass.generic.key=17;deviceClass.specific.key=6","capabilities":["cover","toggle","position"],"primary_attribute":"cover.state"} x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.41 x_zwave_values.Meter_value_66049=0 x_zwave_values.Multilevel_Switch_Down=null x_zwave_values.Multilevel_Switch_Up=null x_zwave_values.Multilevel_Switch_currentValue=99 x_zwave_values.Multilevel_Switch_duration="unknown" x_zwave_values.Multilevel_Switch_restorePrevious=null x_zwave_values.Multilevel_Switch_targetValue=99 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_System_Hardware_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null zwave_device.capabilities=[38,50,113] zwave_device.endpoint=1 zwave_device.failed=null zwave_device.impl_sig="24225:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=148 zwave_device.version_info=nullThanks!
Another one for you, @toggledbits.
I have two water sensors (same device, NAS-WS01Z), but one is reporting leak_detector.state=true even if no alarm is detected (I double checked from ZWaveJS UI):
battery_power.level=0.86 battery_power.since=null leak_detector.state=true x_debug.dt={"entity_class":"Notification Sensor","match":"deviceClass.generic.key=7"} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=86 x_zwave_values.Binary_Sensor_Water=false x_zwave_values.Configuration_Alarm_Activity_Duration=5 x_zwave_values.Configuration_Alarm_Beep=1 x_zwave_values.Configuration_Alarm_Duration=120 x_zwave_values.Configuration_Alarm_Interval=null x_zwave_values.Configuration_Basic_Set_Level=255 x_zwave_values.Configuration_First_Alarm_Activity_Duration=null x_zwave_values.Configuration_Water_Detection=1 x_zwave_values.Manufacturer_Specific_manufacturerId=600 x_zwave_values.Manufacturer_Specific_productId=4229 x_zwave_values.Manufacturer_Specific_productType=3 x_zwave_values.Notification_Water_Alarm_Sensor_status=null x_zwave_values.Notification_alarmLevel=0 x_zwave_values.Notification_alarmType=0 x_zwave_values.Version_firmwareVersions=null x_zwave_values.Version_hardwareVersion=null x_zwave_values.Version_libraryType=null x_zwave_values.Version_protocolVersion=null x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=43200 zwave_device.capabilities=[48,112,113,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Notification Sensor" zwave_device.impl_sig="24225:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.last_wakeup=1724143899220 zwave_device.manufacturer_info=[600,3,4229] zwave_device.max_data_rate=null zwave_device.node_id=114 zwave_device.specific_class="Notification Sensor" zwave_device.status=1 zwave_device.status_text="asleep" zwave_device.version_info=[null,null] zwave_device.wakeup_interval=43200here's the other one, correctly report the leak status:
battery_power.level=1 battery_power.since=null leak_detector.state=false x_debug.dt={"entity_class":"Notification Sensor","match":"deviceClass.generic.key=7"} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=100 x_zwave_values.Binary_Sensor_Water=false x_zwave_values.Configuration_Alarm_Activity_Duration=5 x_zwave_values.Configuration_Alarm_Beep=1 x_zwave_values.Configuration_Alarm_Duration=120 x_zwave_values.Configuration_Alarm_Interval=1 x_zwave_values.Configuration_Basic_Set_Level=255 x_zwave_values.Configuration_First_Alarm_Activity_Duration=60 x_zwave_values.Configuration_Water_Detection=1 x_zwave_values.Manufacturer_Specific_manufacturerId=600 x_zwave_values.Manufacturer_Specific_productId=4229 x_zwave_values.Manufacturer_Specific_productType=3 x_zwave_values.Notification_Water_Alarm_Sensor_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null x_zwave_values.Version_firmwareVersions=["2.54"] x_zwave_values.Version_hardwareVersion=48 x_zwave_values.Version_libraryType=6 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=43200 zwave_device.capabilities=[48,112,113,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Notification Sensor" zwave_device.impl_sig="24225:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.last_wakeup=1724105239533 zwave_device.manufacturer_info=[600,3,4229] zwave_device.max_data_rate=null zwave_device.node_id=113 zwave_device.specific_class="Notification Sensor" zwave_device.status=1 zwave_device.status_text="asleep" zwave_device.version_info=[null,"2.54"] zwave_device.wakeup_interval=43200Also, both seems to have no primary value. Thanks.
Hi-
I have an android media player entity publishing from HA. I watch for changes in transport state and media title to trigger some actions.
Though those attributes report as expected, the set rule is being throttled for possible flapping.
There is an attribute for media position that continually updates, I suspect it is causing the evaluations to run constantly.
The workaround I am seeking is to ignore those attributes in HA or MSR. Anyone know how, or have a better idea??
Thx
Btw- this problem has spanned versions of HA and reactor, but I am current on both. Too current on HA for transparency, but the issue has survived several updates.
Referencing an expression inside a reaction is in the form of ${{ expression }}. When referenced inside my shell command to set the watering delay duration for my Rachio sprinkler system, it just does not work.
If I enter "86400" instead of referencing the expression lWateringDelayDuration, it works. Either I am doing something wrong or referencing an expression inside a shell command is not supported.
Reactor version: 24212
Local Expression
lWateringDelayDuration =
Setting Reaction using Shell command
curl -X PUT -H "Content-Type: application/json" -H "Authorization: Bearer xxxxxxxxxx -d '{ "id" : "xxxxxxxxxx", "duration" : ${{ lWateringDelayDuration}} }' https://api.rach.io/1/public/device/rain_delayThanks in advance
As per @toggledbits request, here's a new topic.
My Fibaro Door Window Sensor 2 (FGDW002) is always reporting as open, even if
x_zwave_values.Notification_Access_Control_Door_state=23 x_zwave_values.Notification_Access_Control_Door_state_simple=23which means that the door is closed. It was working before and I could downgrade to test, if necessary. Thanks.
Hi @toggledbits,
I'm not sure if it's a bug or something, but I have a lot of Fibaro Double Switch (FGS223) as follows.
In the example, it's zwavejs>65-2:
energy_sensor.units="kWh" energy_sensor.value=0.21 power_sensor.units="W" power_sensor.value=0 power_switch.state=false x_debug.dt={"entity_class":"Switch","match":"deviceClass.generic.key=16","capabilities":["power_switch","toggle"],"primary_attribute":"power_switch.state"} x_zwave_values.Binary_Switch_currentValue=false x_zwave_values.Binary_Switch_targetValue=false x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.21 x_zwave_values.Meter_value_66049=0 zwave_device.capabilities=[37,50] zwave_device.endpoint=2 zwave_device.failed=null zwave_device.impl_sig="23326:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=65 zwave_device.version_info=nullWhen operating endpoint 2, it's triggered endpoint 1. Endpoint 1 is fine. This is causing a lot of troubles, as you may imagine.
Also, endpoint 0 is not really a switch, and the associated actions are not doing anything at all. Maybe these could be removed. Also, I see battery_maintenance and power_source capabilities, all with null values.
battery_maintenance.charging=null battery_maintenance.rechargeable=false battery_maintenance.replace=false battery_maintenance.state=null heat_detector.state=false power_source.source=null power_switch.state=null x_debug.dt={"entity_class":"Switch","match":"deviceClass.generic.key=16","capabilities":["power_switch","toggle"],"primary_attribute":"power_switch.state","description":"Double Switch 2","model":"FGS223","default_name":"Double Switch 2","manufacturerId":271,"productType":515,"productId":4096} x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Configuration_First_Channel_Energy_Reports_Threshold=100 x_zwave_values.Configuration_First_Channel_Operating_Mode=0 x_zwave_values.Configuration_First_Channel_Power_Reports_Minimum_Time_Between_Reports=10 x_zwave_values.Configuration_First_Channel_Power_Reports_Threshold=20 x_zwave_values.Configuration_First_Channel_Pulse_Time_for_Blink_Mode=5 x_zwave_values.Configuration_First_Channel_Reaction_to_Key_S1_for_Delay_Auto_ON_OFF_Modes=0 x_zwave_values.Configuration_First_Channel_Time_Parameter_for_Delay_Auto_ON_OFF_Modes=50 x_zwave_values.Configuration_General_Purpose_Alarm_Response=3 x_zwave_values.Configuration_Include_Consumption_By_Device_Itself_in_Reports=0 x_zwave_values.Configuration_Input_Button_Switch_Configuration=2 x_zwave_values.Configuration_Key_S1_Associations_Double_Click_Value_Sent=99 x_zwave_values.Configuration_Key_S1_Associations_Send_OFF_With_Single_Click_2=0 x_zwave_values.Configuration_Key_S1_Associations_Send_ON_With_Single_Click_1=0 x_zwave_values.Configuration_Key_S1_Associations_Send_When_Double_Clicking_8=0 x_zwave_values.Configuration_Key_S1_Associations_Send_When_Holding_and_Releasing_4=0 x_zwave_values.Configuration_Key_S1_Associations_Switch_OFF_Value_Sent=0 x_zwave_values.Configuration_Key_S1_Associations_Switch_ON_Value_Sent=255 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Held_Down_and_Released_8=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_1_Time_1=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_2_Times_2=1 x_zwave_values.Configuration_Key_S1_Send_Scenes_When_Pressed_3_Times_4=1 x_zwave_values.Configuration_Key_S2_Associations_Double_Click_Value_Sent=99 x_zwave_values.Configuration_Key_S2_Associations_Send_OFF_With_Single_Click_2=0 x_zwave_values.Configuration_Key_S2_Associations_Send_ON_With_Single_Click_1=0 x_zwave_values.Configuration_Key_S2_Associations_Send_When_Double_Clicking_8=0 x_zwave_values.Configuration_Key_S2_Associations_Send_When_Holding_and_Releasing_4=0 x_zwave_values.Configuration_Key_S2_Associations_Switch_OFF_Value_Sent=0 x_zwave_values.Configuration_Key_S2_Associations_Switch_ON_Value_Sent=255 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Held_Down_and_Released_8=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_1_Time_1=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_2_Times_2=1 x_zwave_values.Configuration_Key_S2_Send_Scenes_When_Pressed_3_Times_4=1 x_zwave_values.Configuration_Periodic_Active_Power_Reports=3600 x_zwave_values.Configuration_Periodic_Energy_Reports=3600 x_zwave_values.Configuration_Report_During_Blink_Mode=0 x_zwave_values.Configuration_Second_Channel_Energy_Reports_Threshold=100 x_zwave_values.Configuration_Second_Channel_Operating_Mode=0 x_zwave_values.Configuration_Second_Channel_Power_Reports_Minimum_Time_Between_Reports=10 x_zwave_values.Configuration_Second_Channel_Power_Reports_Threshold=20 x_zwave_values.Configuration_Second_Channel_Pulse_Time_for_Blink_Mode=5 x_zwave_values.Configuration_Second_Channel_Reaction_to_Key_S2_for_Delay_Auto_ON_OFF_Modes=0 x_zwave_values.Configuration_Second_Channel_Time_Parameter_for_Delay_Auto_ON_OFF_Modes=50 x_zwave_values.Configuration_Send_Secure_Commands_to_2nd_Association_Group_1=1 x_zwave_values.Configuration_Send_Secure_Commands_to_3rd_Association_Group_2=1 x_zwave_values.Configuration_Send_Secure_Commands_to_4th_Association_Group_4=1 x_zwave_values.Configuration_Send_Secure_Commands_to_5th_Association_Group_8=1 x_zwave_values.Configuration_Smoke_CO_or_CO2_Alarm_Response=3 x_zwave_values.Configuration_State_After_Power_Failure=1 x_zwave_values.Configuration_Temperature_Alarm_Response=1 x_zwave_values.Configuration_Time_of_Alarm_State=600 x_zwave_values.Configuration_Water_Flood_Alarm_Response=2 x_zwave_values.Manufacturer_Specific_manufacturerId=271 x_zwave_values.Manufacturer_Specific_productId=4096 x_zwave_values.Manufacturer_Specific_productType=515 x_zwave_values.Notification_Heat_Alarm_Heat_sensor_status=0 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null x_zwave_values.Protection_exclusiveControlNodeId=null x_zwave_values.Protection_local=0 x_zwave_values.Protection_rf=0 x_zwave_values.Protection_timeout=null x_zwave_values.Version_firmwareVersions=["3.2"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=3 x_zwave_values.Version_protocolVersion="4.5" zwave_device.capabilities=[91,112,113,114,117,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Binary Switch" zwave_device.impl_sig="23326:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=true zwave_device.is_routing=true zwave_device.is_secure=false zwave_device.manufacturer_info=[271,515,4096] zwave_device.max_data_rate=null zwave_device.node_id=65 zwave_device.specific_class="Binary Power Switch" zwave_device.status=4 zwave_device.status_text="alive" zwave_device.version_info=[null,"3.2"]Thanks.
Good morning,
I'm having an issue with controlling my Zooz Zen14 outdoor double outlet. I should be able to control each outlet individually, and this does work when use Home Assistant (haas) from Reactor.
When I use zwavejs, I see 3 entries:
8305eccf-a99e-421f-ad18-1f08da9c8c9c-image.png
The first entry is for the overall device. I can turn both outlets on and off (in theory) by setting the power_switch state to on or off. This does turn them on and off when using zwavejs.
When I go to the individual outlets, performing the power_switch.on or power_switch.off actions turns them all (main, 1 and 2) on or off, and not just the individual outlets. When I perform the same action from haas, turning on outlet 1 will turn on the main switch and 1, but not 2.
I reviewed the logs for that node and I'm not seeing anything obvious.
:~/reactor/logs$ cat reactor.log.1 | grep ZWaveJSController#zwavejs | grep "node 216" [latest-24212]2024-08-07T00:19:00.233Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "endpoint": 0, "property": "targetValue", "newValue": true, "prevValue": false, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:00.235Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 0, "newValue": true, "prevValue": false, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:00.321Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 0, "newValue": true, "prevValue": true, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:00.322Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "targetValue", "endpoint": 0, "newValue": true, "prevValue": true, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:00.323Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "0:37:duration:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "duration", "endpoint": 0, "newValue": { "value": 0, "unit": "seconds" }, "prevValue": { "value": 0, "unit": "seconds" }, "propertyName": "duration" } } [latest-24212]2024-08-07T00:19:02.189Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:currentValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "currentValue", "endpoint": 1, "newValue": true, "prevValue": false, "propertyName": "currentValue" } } [latest-24212]2024-08-07T00:19:02.192Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:targetValue:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "targetValue", "endpoint": 1, "newValue": true, "prevValue": false, "propertyName": "targetValue" } } [latest-24212]2024-08-07T00:19:02.193Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs update node 216 value "1:37:duration:" data [Object]{ "source": "node", "event": "value updated", "nodeId": 216, "args": { "commandClassName": "Binary Switch", "commandClass": 37, "property": "duration", "endpoint": 1, "newValue": { "value": 0, "unit": "seconds" }, "prevValue": { "value": 0, "unit": "seconds" }, "propertyName": "duration" } } [latest-24212]2024-08-07T05:32:30.127Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 0 (entity "216-0") [latest-24212]2024-08-07T05:32:30.127Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 1 (entity "216-1") [latest-24212]2024-08-07T05:32:30.128Z <ZWaveJSController:INFO> ZWaveJSController#zwavejs configuring node 216 endpoint 2 (entity "216-2")I'm running:
Reactor (Multi-hub) latest-24212-3ce15e25
ZWaveJSController [0.1.23326] (with zwavejs_data from 7/25/2024)
HA:
Core 2024.7.3
Supervisor 2024.08.0
Operating System 12.3
Frontend 20240710.0
TTS in MSR?
-
@toggledbits, I wounder if it's possible to use the "PlayURI" command, as in the Reactor in Vera. The aim is to play a certain Sonos playlist. My Sonos is visible both as a Vera integration and a HA integration. The Vera integration shows up as an option, but doesn't work. The HA integration don't seem to have that option in MSR. I tried to add it using the same method as you descriped above, but that didn't work. Do you know how to fix this?
Best regards,
/Fanan -
For Hass, the
x_hass_media_player.play_media
action is the one to use, but the parameters are platform (Sonos) dependent and you need to figure them out. The Hass documentation for the Sonos component has some information, but it's anything but user-friendly. Google is your friend.For Hubitat, I've never had any luck getting Sonos to play queues, even from the Hubitat's own UI.
I will say, this is a reflection of how much the Sonos plugin on Vera simplifies the use of the zone player, because the Hass and Hubitat interfaces are pretty raw/low-level, and Sonos is complex.
-
@toggledbits And in Hubitat?
-
I think I answered that.
-
This news just in from Microsoft:
"Thanks for using Azure Text-to-Speech. We would like to share the great news that we have recently released 12 new regions. We also released neural Text-to-Speech in 10 more languages, a new neural voice (Jenny Multilingual) that speaks 14 languages, 11 more neural voices in American English and 5 more neural voices in Chinese. When using neural voice, synthesized speech is nearly indistinguishable from human recordings."
-
@librasun . I'm trying to add Microsofts TTS service, but it doesn't work. I got a API key and everything. Still doesn't work. My aim is to use a swedish neural voice instead of Googles voices. Is it working for you?
EDIT: I got it working! The neural voices don't support my region, so I had to change the region (created a new service), when I was logged in at Azure.
-
I am trying to enable MSR TTS on Google home devices. I found the local_hass_devices.yaml file already existed with the above example.
So in the true spirit of cutting and pasting while not knowing what I am doing I ended up with the following file:# This file has local definitions for HomeAssistant devices. --- entities: # Entry shows how an entity can have a service added and its name forced "hass>sensor_connected_clients": name: "WebSocket Clients" services: - homeassistant # Sample Sonos device, add the Hass "tts" service for text-to-speech capability "hass>media_player_sonos_living_room": service: - tts # Sample Sonos device, add the Hass "tts" service for text-to-speech capability "hass>media_player.family_room_speaker": service: - tts
-
What you've done here (correct approach, one little error, see below) is declare that those two
media_player
devices have thetts
service as an additional declared service. That will cause MSR to bring in the attributes and actions of that service as supported for the device.Hass doesn't publish what Hass services a Hass entity supports through its API. The only service that can be known for certain is the one that is part of the Hass entity ID (e.g. the Hass entity ID
media_player.family_room_speaker
tells you that it will support themedia_player
service). Any other supported services (liketts
) aren't enumerated by the API, sadly (in a few cases, they can be inferred as related in a bit mask, but this is an extension and highly implementation/component dependent, not consistent at all, but I try to pick this up when known). This manual way of connecting additional services/capabilities to the entities is the best I could do at the moment.Other things you can do in this file are override the name of the device (by supplying
name: "myoverridename"
at the same indent level asservice:
), and change the primary attribute (primary_attribute: "servicename.attributename"
). When setting/overriding the primary attribute, the service must be supported by the device (so known by the device ID or added viaservices:
in this file).One small correction, though: the canonical ID for the third entry
hass>media_player.family_room_speaker
-- the dot (.
) should probably be an underscore (_
). Confirm on the Entities list. -
Picking up on my old thread. I just got Alexa working with tts in Home Assistant. Is it possible to get it to work with MSR as well? I added the speakers to my local_hass_devices.yaml, and then I got the same tts options as with google speakers. But that don't work for sending tts messages. In HA I have to add "Type: tts" for it to work. I also don't see the native Alexa voice as an option, only the same as the google speakers. It's not a personal big deal, but would be a fun and maybe useful feature in the future.
-
Let me play around with this a bit. You can add the
notify
service to the entity (have you done this?), but I'm not sure about the rest of the parameters. Some are tricky. But I want to get something like this going in my house, so good excuse to figure it out... -
@toggledbits said in TTS in MSR?:
You can add the notify service to the entity (have you done this?)
@toggledbits No, I haven't used the notify service. I might give it a try later this week. If you (or anyone else) figure it out, please share!
-
@fanan Per this topic https://smarthome.community/topic/744/sending-a-service-request-to-home-assistant?_=1638829172919 I couldn't get Alexa tts to work in MSR, but I do have it working in openLuup with the following code that sits inside a simple plugin:
myEchoDevice = "alexa_media_".. myEchoDevice myEchoMessage = table.concat(myEchoMessage) local request_body = json.encode {message = myEchoMessage, data = {["type"] = "announce",method = "all"}} local response_body = {} local theURL = 'http://'..HomeAssistantIP..':'..HomeAssistantPort..'/api/services/notify/'..myEchoDevice r, c, h = http.request { url = theURL, method = "POST", headers = { ["Content-Type"] = "application/json", ["Authorization"] = "Bearer ".. HomeAssistantToken, ["Content-Length"] = request_body:len() }, source = ltn12.source.string(request_body), sink = ltn12.sink.table(response_body) }
The variable "myEchoDevice" is the exact name of the specific echo device (or device group) as presented in the Amazon Alexa app. I typically broadcast to all my devices via a group, intercom style, so I catch the message wherever I am in my home. The variable "HomeAssistantToken" needs to be created in HA. "myEchoMessage "is a lua table in the above code, but you could just as easily capture the message as a string, and then trim the string prior to sending it to the HTTP post request.
-
@fanan OK. So it turns out that this has (much) more to do with the way the Alexa Media Player service works than anything. You can simply use the
call_service
action on the controller's system object to call thenotify.alexa_media
service (or its variants, more on that below). If you do it through the system entity, you don't need to make exceptions in your local configuration to add the service -- you can run a service against any entity from the system entity, and if it's not supported, the (Hass) entity will either ignore it or log an error, but nobody dies, missiles do not launch, gravity still works, the sun continues to rise and set, etc.Above are two different versions of the service call that do about the same thing. I'll work backwards because that's the way I figured it out...
The green-circled "short" version of the service name requires that you specify the
target
in the service data. The service data is a structure as shown (always). Also see the docs for the component for more info about this service and its data. Thetarget
field must be specified when using this short form of the service name, and its value is an array of HomeAssistant entity IDs (not Reactor entity IDs) for the players (Dots and Echos) that will speak the phrase. Thedata
substructure must be given as shown.The red-circled variant uses a longer service name that includes the Amazon device's name. Apparently the component creates a set of aliased services, each with the device name appended to the base service name. I find this annoying, because I have over a dozen Dots/Echos, so and it creates a bunch of data pollution. But, it's there, and it's usable. When you use a "long" service name, you don't need to specify
target
in the data, but it's otherwise the same, as shown. -
@toggledbits Speaking of that, is there a way to easily compose re-usable actions, so I could just pass the arguments (message and device) and call the same function? I'll use for the very same purpose, since I have a couple of endpoints doing notifications/TTS. Thanks!
-
@toggledbits That's great news! My only problem is that my Hass entity don't have any actions... :
I don't know how you activated the x_hass_system.call_service?Do I have to change anything in my reactor.yaml?
- id: hass enabled: true implementation: HassController name: Home Assistant config: source: 'wss://f_______' access_token: "eyJ0eXAi_______________________________________________________________________________________________________________________________2-nLoI369-iYcJf9z_3sviSiWA" # # ignore_cert - If true, suppresses certificate validation when using wss:// (Websocket # with SSL/TLS) and thus allows a self-signed certificate to be used on # the Hass system. #ignore_cert: false # # dump_all_states - This is for troubleshooting. Do not enable unless asked. #dump_all_states: false log_events: false
-
@toggledbits Ahh..! I see it now. Thanks! I'm struggeling with the indentation, but I guess it will come around after a few tries...
The best of all is as you so well put it: "...and if it's not supported, the (Hass) entity will either ignore it or log an error, but nobody dies, missiles do not launch, gravity still works, the sun continues to rise and set, etc."
Even Shakespeare him self would be impressed! -
-