Home Automation means you have to have a way of describing the logical steps you want your home to implement automatically.
Whilst I've always been a fan of the Lua language, as used in Vera (and openLuup) for scenes and plugins, it's perhaps not ideal. For this reason, there has been a long development history of plugins with their own "language" to help define the automation logic: PLEG (for those with a long memory), AltUI workflows, Rules Engine, Reactor, MSR, ...
It's always seemed to me that the 'best' way of describing logic would be a language designed for that purpose – a "logic programming language". Perhaps one of the most famous, and venerable, is Prolog, which had its fiftieth birthday last year in 2022.
Thanks to some relatively recent research A Hitchhiker’s Guide to Reinventing a Prolog Machine, Paul Tarau (2017) it's become possible to implement a very efficient Prolog engine in a reasonably concise way. So, just for fun, I'm developing a CGI plugin for describing openLuup actions in Prolog.
I have an early prototype running (written in Lua, of course). It presents a web page which looks like a fairly typical Interactive Development Environment (IDE) and contains some primitives which allow basic access to the Luup engine.
Screenshot 2023-03-10 at 18.27.33.png
In a subsequent post, I'll give a glimpse of its capabilities...
How to launch an API code on the VERASECURE?
The current scripts are obsolete (SMSCODE).
Is there a firmware FORK for the VERASECURE?
On start up the log indicates the following:
2023-12-19 10:17:12.588 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:upnp-org:serviceId:Dimming1","LoadLevelTarget","",209) old value "" 2023-12-19 10:17:12.589 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:upnp-org:serviceId:Dimming1","LoadLevelTarget","",209) old value "" 2023-12-19 10:17:12.589 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:upnp-org:serviceId:Dimming1","LoadLevelStatus","",209) old value "" 2023-12-19 10:17:12.589 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:upnp-org:serviceId:Dimming1","LoadLevelLast","",209) old value "" 2023-12-19 10:17:12.589 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:upnp-org:serviceId:Dimming1","TurnOnBeforeDim","",209) old value "" 2023-12-19 10:17:12.590 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:upnp-org:serviceId:Dimming1","AllowZeroLevel","",209) old value "" 2023-12-19 10:17:12.590 luup_log:209: VirtualDevices[3.0-beta7@209](setVar@104):setVar("urn:bochicchio-com:serviceId:VirtualBinaryLight1","SetBrightnessURL","",209) old value "" 2023-12-19 10:17:12.590 luup_log:209: VirtualDevices[3.0-beta7@209](initializeMqtt@421):initializeMqtt(209,{ PowerStatusOff={ Value="0", Service="urn:upnp-org:serviceId:SwitchPower1", Variable="Status" }, BrightnessValue={ Variable="LoadLevelStatus", Service="urn:upnp-org:serviceId:Dimming1" }, PowerStatusOn={ Value="1", Service="urn:upnp-org:serviceId:SwitchPower1", Variable="Status" } }) - openLuup: true 2023-12-19 10:17:12.591 luup_log:209: VirtualDevices[3.0-beta7@209](subscribeToMqtt@414):subscribeToMqtt(209,nil,{ deviceID=209, opts={ Value="0", Service="urn:upnp-org:serviceId:SwitchPower1", Variable="Status" } }) 2023-12-19 10:17:12.591 openLuup.context_switch:: ERROR: [dev #209] ./L_VirtualLibrary.lua:415: attempt to concatenate field 'topic' (a nil value) 2023-12-19 10:17:12.591 openLuup.scheduler:: job aborted : ./L_VirtualLibrary.lua:415: attempt to concatenate field 'topic' (a nil value)The MQTT variables are all set to "skip":
MQTT_BrightnessValue
MQTT_PowerStatusOff
MQTT_PowerStatusOn
However it looks like the code doesn't check for "skip" and executes the functions initializeMqtt() and subscribeToMqtt() disappearing into the weeds at that point as there is nothing to subscribe to.
It would also be good if the code treated an empty string in the same way as it uses the key word "skip". It's not obvious that "skip" needs to be explicitly used.
I still use Vera controllers in combination with ReactorSensors. I have several Reactor sensors in use to retrieve weather data from Wunderground (i have a personal weather station), my smartmeter etc.
Recently I installed solar panels with a SolarEdge inverter. SolarEdge has an API to retrieve my power production data from their cloud.
Output is in json.
So I created a new Reactor Sensor. Connection is working (query okay).
But I encounter problems at the Value Expressions. Either I get ""query okay" but no data or I get "query okay but 1 expressions failed"
This is the json output
{"overview":{"lastUpdateTime":"2023-05-12 10:45:57","lifeTimeData":{"energy":476310.0,"revenue":216.577},"lastYearData":{"energy":433001.0},"lastMonthData":{"energy":433001.0},"lastDayData":{"energy":8262.0},"currentPower":{"power":5647.0},"measuredBy":"INVERTER"}}So it has different layers/levels.
I tried to put in the Value Expressions field several combinations to get the energy data of today (8262.0), like:
response.lastDayData.energy
response.overview.lastDayData.energy
response.overview.lastUpdateTime.lastDayData.energy
all fail...
Who can help me with this ?
I have the following issue: In my Vera, I have created a dimmer using the Switchboard plugin. I want this light always turn on at 100% brightness when turn the light on. By default, the dimmer remembers its last used setting. I have created the following scene: when the light is turned off, the LoadLevelLast should be 100.
9937e326-2453-43bd-bd32-917803b38e90-image.png
Manually, this works through the test Luup code (Lua), but not through the scene's action by execute the following Luup code.
I also tried in MSR, but no result
Does anyone know the solution to this?
Just seen notification to Netatmo developers that the current password-based login is being disabled as from October.
Oath2 is now a requirement for apps needing access to Netatmo. This will require some changes to my venerable plug-in. I’m not sure how easy this will be with the current libraries in use.
Does anyone out there use the Netatmo plug-in?
Does anyone have any advice on using Oath2?
Hardly a big deal, and likely user error. Bare metal install on Debian Bullseye
Observed behaviour:
TTS announcements are made with the correct volume. So a message to group 'Everywhere' with Volume 40 is announced. Asking an individual echo device to state its volume after the announcement gets the response 'This device is at volume 4'
So far so good.
Using the:
x_vera_svc_bochicchio_com_VeraAlexa1.SetVolumeIn an MSR reaction appears to have no impact when either applied to the group 'Everywhere' or a specific device.
So executing this reaction:
Screenshot 2023-01-31 at 09.17.40.png
Is acknowledged by the device (with a 'beep') and shows the Lua Log below:
2023-01-31 09:21:45.778 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x5572399831f8 2023-01-31 09:21:45.779 openLuup.server:: GET /data_request?GroupZones=Office&DesiredVolume=10&DeviceNum=22&id=action&serviceId=urn%3Abochicchio-com%3AserviceId%3AVeraAlexa1&action=SetVolume&output_format=json&_r=1675156905777 HTTP/1.1 tcp{client}: 0x5572399831f8 2023-01-31 09:21:45.780 luup.call_action:: 22.urn:bochicchio-com:serviceId:VeraAlexa1.SetVolume 2023-01-31 09:21:51.670 luup.variable_set:: 22.urn:bochicchio-com:serviceId:VeraAlexa1.LatestResponse was: sending cmd:speak:<s>Volume Set</s><break time="0s" /> to dev:Office type:A32DOYMUN6DTXA serial:G090U50991550NLS cu... now: sending cmd:vol:10 to dev:Office type:A32DOYMUN6DTXA serial:G090U50991550NLS customerid:A1CVTZEBJIUFJI #hooks:0 2023-01-31 09:21:51.671 openLuup.server:: request completed (35 bytes, 1 chunks, 5891 ms) tcp{client}: 0x5572399831f8 2023-01-31 09:21:51.683 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x5572399831f8 2023-01-31 09:21:51.685 openLuup.server:: request completed (930 bytes, 1 chunks, 42818 ms) tcp{client}: 0x557239726708 2023-01-31 09:21:51.687 openLuup.server:: request completed (930 bytes, 1 chunks, 42548 ms) tcp{client}: 0x5572392c0fd8 2023-01-31 09:21:51.688 openLuup.server:: request completed (930 bytes, 1 chunks, 12501 ms) tcp{client}: 0x5572392c7f88 2023-01-31 09:21:51.692 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x5572392c7f88 2023-01-31 09:21:51.704 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x557239be10b8 2023-01-31 09:21:51.704 openLuup.server:: GET /data_request?id=status&Timeout=15&DataVersion=66666322&MinimumDelay=50&output_format=json&_r=1675156911703 HTTP/1.1 tcp{client}: 0x557239be10b8 2023-01-31 09:21:51.905 openLuup.server:: GET /data_request?id=lu_status2&output_format=json&DataVersion=66666322&Timeout=60&MinimumDelay=1500&_=1675022474387 HTTP/1.1 tcp{client}: 0x5572392c0fd8 2023-01-31 09:21:53.042 openLuup.server:: GET /data_request?id=lu_status2&output_format=json&DataVersion=66666322&Timeout=60&MinimumDelay=1500&_=1675079237873 HTTP/1.1 tcp{client}: 0x557239726708However direct interrogation of the device reveals the volume has not changed.
I assume I'm doing something wrong or not understanding how this is meant to work?
One other observation is that messages announce to the 'Everywhere' group appear to make the volume 'stick' where as messages to an individual device appear to revert to the previous volume setting.
My expectation would be analagous to a radio i.e. the volume stays as it was last set, but happy to be corrected.
TIA!
C
Anyone else seeing issues with Vera TTS? All was working fine. I assumed the cookie had expired, but even having replaced it, and seeing that the .alexa.login file is aging (as I'd expect) No speech.
I seem to be getting an odd timeout but no idea from where.
Debian Bullseye, bare metal
Good call from this morning:
2023-01-18 08:22:51.657 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x563e8a2345e8 2023-01-18 08:22:51.667 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x563e89df13d8 2023-01-18 08:22:51.668 openLuup.server:: GET /data_request?id=status&Timeout=15&DataVersion=31085221&MinimumDelay=50&output_format=json&_r=1674030171666 HTTP/1.1 tcp{client}: 0x563e89df13d8 2023-01-18 08:22:58.223 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x563e8a4ab388 2023-01-18 08:22:58.223 openLuup.server:: GET /data_request?Text=Rachel%20has%20arrived%20at%20Washtec&Language=en-GB&GroupZones=Everywhere&Volume=50&DeviceNum=22&id=action&serviceId=urn%3Abochicchio-com%3AserviceId%3AVeraAlexa1&action= Say&output_format=json&_r=1674030178221 HTTP/1.1 tcp{client}: 0x563e8a4ab388 2023-01-18 08:22:58.224 luup.call_action:: 22.urn:bochicchio-com:serviceId:VeraAlexa1.Say 2023-01-18 08:22:58.224 luup_log:22: VeraAlexa: addToQueue: added to queue for 22 2023-01-18 08:23:09.379 luup.variable_set:: 22.urn:bochicchio-com:serviceId:VeraAlexa1.LatestResponse was: sending cmd:speak:<s><lang xml:lang="en-UK"><amazon:domain name="conversational">The temperature outside is -3 degr... now: sendi ng cmd:speak:<s>Rachel has arrived at Washtec</s><break time="0s" /> to dev:Everywhere type:A3C9PE6TNYLTCH ser... #hooks:0 2023-01-18 08:23:09.381 openLuup.server:: request completed (29 bytes, 1 chunks, 11156 ms) tcp{client}: 0x563e8a4ab388 2023-01-18 08:23:09.391 luup.variable_set:: 25001.urn:micasaverde-com:serviceId:SecuritySensor1.Tripped was: 0 now: 1 #hooks:0 2023-01-18 08:23:09.391 luup.variable_set:: 25001.urn:micasaverde-com:serviceId:SecuritySensor1.LastTrip was: 1674030032 now: 1674030189 #hooks:0 2023-01-18 08:23:09.394 openLuup.server:: request completed (1389 bytes, 1 chunks, 31782 ms) tcp{client}: 0x563e897eefd8 2023-01-18 08:23:09.395 openLuup.server:: request completed (1389 bytes, 1 chunks, 31662 ms) tcp{client}: 0x563e8a7c5248 2023-01-18 08:23:09.396 openLuup.server:: request completed (1389 bytes, 1 chunks, 17728 ms) tcp{client}: 0x563e89df13d8 2023-01-18 08:23:09.396 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x563e8a4ab388 2023-01-18 08:23:09.411 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x563e8a13f3c8 2023-01-18 08:23:09.412 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x563e8a79f3c8 2023-01-18 08:23:09.412 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x563e89df13d8 2023-01-18 08:23:09.413 openLuup.server:: GET /data_request?newTargetValue=1&DeviceNum=20330&id=action&serviceId=urn%3Aupnp-org%3AserviceId%3ASwitchPower1&action=SetTarget&output_format=json&_r=1674030189410 HTTP/1.1 tcp{client}: 0x563e 8a13f3c8 2023-01-18 08:23:09.413 openLuup.server:: GET /data_request?id=status&Timeout=15&DataVersion=31085224&MinimumDelay=50&output_format=json&_r=1674030189411 HTTP/1.1 tcp{client}: 0x563e8a79f3c8 2023-01-18 08:23:09.413 luup.call_action:: 20330.urn:upnp-org:serviceId:SwitchPower1.SetTarget 2023-01-18 08:23:09.413 luup.call_action:: action will be handled by parent: 37 2023-01-18 08:23:09.413 luup.variable_set:: 20330.urn:upnp-org:serviceId:SwitchPower1.Target was: 1 now: 1 #hooks:0 2023-01-18 08:23:09.449 openLuup.server:: request completed (35 bytes, 1 chunks, 36 ms) tcp{client}: 0x563e8a13f3c8 2023-01-18 08:23:09.461 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x563e8a13f3c8 2023-01-18 08:23:09.564 openLuup.server:: request completed (819 bytes, 1 chunks, 151 ms) tcp{client}: 0x563e8a79f3c8 2023-01-18 08:23:09.569 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x563e8a79f3c8 2023-01-18 08:23:09.581 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x563e8a32bf28Bad request from just now:
2023-01-18 18:29:26.695 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x557239889e58 2023-01-18 18:29:26.696 openLuup.server:: GET /data_request?id=status&Timeout=15&DataVersion=66503545&MinimumDelay=50&output_format=json&_r=1674066566691 HTTP/1.1 tcp{client}: 0x557239889e58 2023-01-18 18:29:26.799 openLuup.server:: request completed (833 bytes, 1 chunks, 2249 ms) tcp{client}: 0x557239a62f78 2023-01-18 18:29:26.911 openLuup.server:: GET /data_request?id=lu_status2&output_format=json&DataVersion=66503545&Timeout=60&MinimumDelay=1500&_=1674030721531 HTTP/1.1 tcp{client}: 0x5572385f78d8 2023-01-18 18:29:27.028 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x557238b98c58 2023-01-18 18:29:27.029 openLuup.server:: GET /data_request?Text=Testing...1...2...3&Language=en-GB&GroupZones=Everywhere&Volume=50&DeviceNum=22&id=action&serviceId=urn%3Abochicchio-com%3AserviceId%3AVeraAlexa1&action=Say&output_format=json&_r=1674066567027 HTTP/1.1 tcp{client}: 0x557238b98c58 2023-01-18 18:29:27.029 luup.call_action:: 22.urn:bochicchio-com:serviceId:VeraAlexa1.Say 2023-01-18 18:29:27.029 luup_log:22: VeraAlexa: addToQueue: added to queue for 22 2023-01-18 18:29:43.149 openLuup.server:: error 'closed' sending 4 bytes to tcp{client}: 0x557238b98c58 2023-01-18 18:29:43.150 openLuup.server:: ...only 0 bytes sent 2023-01-18 18:29:43.150 openLuup.server:: error 'closed' sending 29 bytes to tcp{client}: 0x557238b98c58 2023-01-18 18:29:43.150 openLuup.server:: ...only 0 bytes sent 2023-01-18 18:29:43.150 openLuup.server:: error 'closed' sending 2 bytes to tcp{client}: 0x557238b98c58 2023-01-18 18:29:43.150 openLuup.server:: ...only 0 bytes sent 2023-01-18 18:29:43.150 openLuup.server:: error 'closed' sending 5 bytes to tcp{client}: 0x557238b98c58 2023-01-18 18:29:43.150 openLuup.server:: ...only 0 bytes sent 2023-01-18 18:29:43.150 openLuup.server:: request completed (29 bytes, 1 chunks, 16121 ms) tcp{client}: 0x557238b98c58 2023-01-18 18:29:43.153 luup_log:63: BroadLink_Mk2 debug: RM3 Mini - IR 1: device is not a sensor or if a sensor; is not coded for 2023-01-18 18:29:43.153 luup_log:63: BroadLink_Mk2 debug: RM3 Mini - IR 1: veraId: 64, blId: a0:43:b0:8b:e0:e5, altId: a0:43:b0:8b:e0:e5_ir 2023-01-18 18:29:43.153 luup_log:63: BroadLink_Mk2 debug: RM3 Mini - IR 1: urn:schemas-micasaverde-com:device:IrTransmitter:1 2023-01-18 18:29:43.154 openLuup.server:: GET /data_request?id=lu_status2&output_format=json&DataVersion=66503545&Timeout=60&MinimumDelay=1500&_=1674066518681 HTTP/1.1 tcp{client}: 0x557239a62f78 2023-01-18 18:29:43.155 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x557238b98c58 2023-01-18 18:29:43.157 openLuup.server:: request completed (591 bytes, 1 chunks, 16460 ms) tcp{client}: 0x557239889e58 2023-01-18 18:29:43.161 openLuup.io.server:: HTTP:3480 connection closed openLuup.server.receive closed tcp{client}: 0x557239889e58 2023-01-18 18:29:43.175 openLuup.io.server:: HTTP:3480 connection from 192.168.70.249 tcp{client}: 0x5572399f30e8 2023-01-18 18:29:43.176 openLuup.server:: GET /data_request?id=status&Timeout=15&DataVersion=66503545&MinimumDelay=50&output_format=json&_r=1674066583172 HTTP/1.1 tcp{client}: 0x5572399f30e8 2023-01-18 18:29:57.979 luup.variable_set:: 20380.urn:upnp-org:serviceId:TemperatureSensor1.CurrentTemperature was: 22 now: 21 #hooks:0Any thoughts?
Cheers
C
Hello, I'm looking for a way to create a script/executable file I can launch from my Loupedeck controller that will trigger outlets on a Zwave power strip. Can anyone point me to some info on how to do this?
I'm using a VeraPlus controller
Thanks
I use the excellent SiteSensor plugin of @toggledbits for some years to get the data from my PWS on Wunderground.
This has worked flawlessly but recently it suddenly stopped working.
I see this in my Vera:
6899a8b1-ad67-430a-9dc8-f1da42b04b62-image.png
When I copy/paste the URL code to be queried in my browser this still works.
This is the URL:
https://api.weather.com/v2/pws/observations/current?stationId=ILIMBURG130&format=json&units=m&numericPrecision=decimal&apiKey=xxxxxxxxxxxxxxxxxxxxxxxxx
Patrick (or someone else on this forum) can you help me solve this ?
Many thanks in advance!
Virtual HTTP Devices plug-in:
I wanted to try this out. Installed the plugin and created one device, which came up as a light bulb. So far so good. In AltUI I clicked on the On/Off slider on the page. The log shows that the Target is set to one. Likewise for the Variable list in AltUI. However the Status never gets set to one and the light bulb icon doesn't go yellow.
In some plugins you set the Target and then the plugin checks the physical device actually went on by checking an actual status report from the device, which can be used to set the variable Status.
In other cases a plugin will send a message to the physical device but that device will have no status feedback mechanism available. So the Status variable has to be set locally when the Target is set and everybody hopes the physical device all worked.
Not to sure what Virtual HTTP Devices plug-in does in this regard? Does the above go in anyway to explaining what I'm seeing? Is the plugin looking for status feedback?
I have a couple of issue with Openluup ATM. I'm going to work through them in the order that they appeared if that's OK 🙂
OpenLuup on bare metal (Debian Bullseye) running Z-way server and Z-wave.me
Issue:
I deleted a (I think) virtual switch in OpenLuup
Now when I call up all devices I have this in a 'tile'
And below (in room 101)
ReferenceError: nil is not defined at eval (eval at evaluateConditions (http://192.168.70.249:3480/J_ALTUI_verabox.js:960:18), :1:1) at Object.evaluateConditions (J_ALTUI_verabox.js:960:18) at Object._evaluateConditions [as evaluateConditions] (J_ALTUI_verabox.js:1642:37) at Object._evaluateConditions [as evaluateConditions] (J_ALTUI_multibox.js:629:89) at Object. (http://192.168.70.249:3480/J_ALTUI_uimgr.js:2572:23) at Function.each (https://cdnjs.cloudflare.com/ajax/libs/jquery/3.5.1/jquery.min.js:2:2976) at _getDeviceIconPath (http://192.168.70.249:3480/J_ALTUI_uimgr.js:2569:10) at _deviceIconHtml (http://192.168.70.249:3480/J_ALTUI_uimgr.js:2739:18) at _internalDeviceDraw (http://192.168.70.249:3480/J_ALTUI_uimgr.js:2765:19) at _deviceDraw (http://192.168.70.249:3480/J_ALTUI_uimgr.js:2840:4)Any ideas from anyone?
Full reboot has been done....
Cheers
C
I've been trying to figure out Reactor but I'm not very good at programming.
I have two scenes in VERA.
One scene should only run during the DAY and then stop running.
One scene should only run during the NIGHT and then stop running.
My scenes start off at the right times, but they do not turn off. I created a Sunrise/Sunset Reactor trigger and added it as a condition to each of my scenes.
However, the Reactor trigger when tripping or untripping does not prevent my Vera scenes from running. It will start them correctly the first day, but after that, both scene stay running and fight with each other. What am I doing wrong?
Thanks for any help!
If you are interested, here are the actions I wish to perform with each scene.
FARM STAND - DAY (runs at Sunrise)
Turn ON a device called LETTUCE LAMP2a) Every 60 min, turn ON a device called LETTUCE PUMP
2b) Wait 15 min then turn OFF a device called LETTUCE PUMP
FARM STAND - NIGHT (runs at Sunset)
Turn OFF a device called LETTUCE LAMP2a) Every 135 min, turn ON a device called LETTUCE PUMP
2b) Wait 15 min then turn OFF a device called LETTUCE PUMP
This sounds simple, but I cannot figure out how to disable these scenes when the theyre not supposed to run.
I am no longer using any VERA scenes. I am only using a REACTOR trigger and activities.
Will my activities do what I need them to do? See below:
Here's what I am trying to accomplish:
AT SUNRISE
Turn ON a light called LETTUCE LAMP and keep it ON.2a) Turn on a device called LETTUCE PUMP for 15 min each hour.
2b) Repeat the pump cycle all day long.
AT SUNSET
Turn OFF a light called LETTUCE LAMP and keep it OFF.2a) Turn on a device called LETTUCE PUMP for 15 min then wait 2 hours..
2b) Repeat the pump cycle all night long.
Hey @toggledbits updated to Reactor 3.9develop-21009.1600 on my VP running 7.32 and I keep getting this pop up and can't change anything in my reactor sensors because of it. I am running Alt UI 2.52 and there are no updates for it. Screen Shot 2021-03-31 at 8.33.47 PM.png
FYI.
Recently a new ALTUI version got pushed out, release 2553. After the update Reactor is no longer showing any of the Control panels in a sensor. looking at the ALTUI changes they seem minimal so in J_ReactorSensor_UI7.js I upped the _MAX_ALTUI_VERSION to 2553 and all seems to be working again.
Good evening, all.
Is there a simple readme to set up and use a Broadlink device with OpenLuup?
The readme on github points to a thread on the old forum, and thence to a rabbit hole.
Is it just a case of adding IP address of the device? Or does it need the MAC?
Then how do I fire commands? It looks like I need to find the codes and send via Lua?
TIA
C
Netatmo – Oath2 login
-
Just seen notification to Netatmo developers that the current password-based login is being disabled as from October.
Oath2 is now a requirement for apps needing access to Netatmo. This will require some changes to my venerable plug-in. I’m not sure how easy this will be with the current libraries in use.
Does anyone out there use the Netatmo plug-in?
Does anyone have any advice on using Oath2?
-
As I saw the same notification, I was wondering whether you are still maintaining it So at least I'm using this plugin, but unfortunately cannot offer any advice on oauth2.
I've been also thinking if Netatmo data could be fetched directly with MSR, using http request(s)? Would like to get rid of Vera dependencies
-
I also use the Netatmo plugin, not on openLuup but still using Vera. I really hope you can and are willing to update the app.
-
Any update? October is approaching..
-
Still failing miserably, I’m afraid. I’ve tried two approaches: one using the Netatmo website to generate an authorisation token, the other to get it directly into the plug-in, but neither work. I either get an HTTP 400 error, which means there’s a syntax error with the request, or a 302, which is an expected redirect but it’s missing important return parameters in the header.
So I’m completely stuck, unless someone (@toggledbits ?) can help me further with Oath2 protocol.
-
I think I’m not the only one with this problem… the Netatmo Homebridge plug-in seems not to be updated, which is unfortunate because that was my alternate route.
It is such a shame that Netatmo has never opened a direct LAN / local network connection rather than having to go through their cloud…
-
I've started using home assistant for the very same reason. When using MSR mixing entities from different controllers feels natural. I don't like Hass for the UI and I find their device model confusing, but there are plenty of integrations and all are very well maintained. I guess that's true for openhab as well.
-
These comments on a HomeBridge plugin GitHub indicate that Netatmo is really still in a state of flux with regard to designing aamore useable API for secure access. There may a few hints that I can try here, but even if nothing works at the moment, it may improve in future...
...not really much consolation for those still wanting to use this. I've placed some Hue motion sensors in position (which include temperature sensors) for the time being.
-
Hi Ak,
Any progress in this? I did write some Lua for oath2 authentication for my Telsa plugin. Main challenge was keeping track of cookies. Not sure if it can give some help.
See https://github.com/reneboer/vera-TeslaCar/blob/master/src/L_TeslaCar1.lua lines 900-1200.
Cheers Rene -
Thanks for this. Just to be clear, the Netatmo app already uses Oath2, but what’s changing is the requirement to use the token, rather than username/password option. This is much more complex, requiring web page redirections and callbacks to app-specific URLs.
Taking a very quick look at your code, I see that it also uses username/password authorization?
As it happens, their threat to turn off the existing access in October has not been carried out, and it’s currently still working.
TBH I had all but given up on trying to fix this, and have already written (yet another) weather app to use the UK’s Met Office data feed to get external weather parameters (MetOffice_DataPoint, available from the AltAppStore, only works in the UK, though.). I also use Shelly H&T devices for internal sensors, so the only thing I don’t have covered is CO2.
-
I may have looked too quickly? Although I see username and pasword variables, the code looks to play with URLs, requests, and headers, which is more the sort of thing I would expect to be necessary. I am clearly missing some understanding of how this is supposed to work. I suspect that some sudden 'Eureka' moment breakthrough is what I need to grasp the concept, but I don't know from where this will come!
-
What I did is make a trace in my browser and login, then save as har file to look back at. Sometimes it helped me to make a python script first so I do not have to worry about the session handling, and then add that to the Lua logic. Not simple to do for sure.
-
Hi Ak,
I put in a workaround. You can get the access and refresh tokens from dev.netatmo.com. I put the access token in as Username and refresh token as Password. In your Netatmo.lua I changed the authenticate function to just return those values (no request to the Netatmo api site). This gets the plugin going again. I also updated the refresh_tokens to update the Username and Password values with the new token values. I expect that will get one through a Luup reload. Bit quick and dirty, but if your interested I can do a github merge request or get you the changes otherwise.Cheers Rene