Gradually turn on lights.
Tom_DT
I have several lights that I would like to turn on very gradually over 15 or 20 seconds. from 0 to .25 in .01 increments. I have tried a few things that came nowhere near working, so here I am.
Multi-System Reactor
Stop the MSR by an external switch on Hubitat.
wmarcolinW
Use case: When performing home maintenance, such as air conditioning, I want all rules involving air conditioning to be disabled. To do this, to day, I have a virtual switch that I placed within all rules involving air conditioning, meaning that if I turn it off, none of them work. Then another situation: the water pump system and garden irrigation, another switch. In short, I had to create several virtual switches in Hubitat to disable rules in MSR. Unfortunately, however, I was unable to cover all scenarios, so I wondered if it would be possible for MSR to support a virtual MSR switch, which, when configured in the reactor settings, would function as a general on/off switch for MSR. If it is configured and turned off, the entire rules and actions in MSR stops working, except for the status change reading process, specifically for this switch, which, when turned on, would restart the MSR. Would it be possible to do something like this? Any recommendations from the experts?
Multi-System Reactor
Error After Upgrade
T
Topic thumbnail image
Multi-System Reactor
Reset attribute value of entity in event handler
R
Topic thumbnail image
Multi-System Reactor
Need help figuring out how to delay a reset on reaction
T
Topic thumbnail image
Multi-System Reactor
Way to search for rules (rule state) in other rules
T
@toggledbits, not sure if this is a feature request or I'm using the search tool wrong. You have a "Search for rule" in the Rules Set tab in MSR. It works nicely to find a rule and bring up said rule, but can it/could it be used for as a "where used?" global search? For instance, I have a fairly large set of rules, divided up into 10 different rulesets. There's easily a hundred individual rules, and many of the rules have Rule State triggers, which of course refer to other rules. Amongst my troubleshooting today, I came across what may have been a duplicate or troubleshooting attempt, but I can't tell if it's actually used as a Rule State in another rule without opening each rule that I suspect it may be a part of. Thanks.
Multi-System Reactor
Links to MSR from HA
Tom_DT
I am using Home Assistant a lot recently. On a dashboard showing the devices, I would like to show a link to the MSR rule that controls the devices. Is there a way to link directly into MSR?
Multi-System Reactor
Set Reaction > Script Action
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Errors after updating to MQTTController build 25139
tunnusT
I'm running MSR build 25139 on Docker, using MQTT controller 24293, and everything working as expected. But if I try to upgrade to MQTTController build 25139, I'm getting the following errors on MSR UI: An Entity Attribute condition in "Lay-Z-Spa auto heating off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.god Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa auto heating off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute temperature_sensor.green Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa filter pump auto off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute temperature_sensor.red Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa filter pump auto run" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.pump Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa watchdog" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.status Last 11:20:37 My MQTT configuration (local_mqtt_devices.yaml) for the related entity is: layzspa_message: type: ValueSensor capabilities: ["temperature_sensor", "value_sensor", "power_sensor"] primary_attribute: power_sensor.value events: "layzspa/message": "power_sensor.value": json_payload: true if_expr: '! isnull( payload?.PWR )' expr: "float(payload.PWR)" "value_sensor.air": json_payload: true if_expr: '! isnull( payload?.AIR )' expr: "float(payload.AIR)" "value_sensor.pump": json_payload: true if_expr: '! isnull( payload?.FLT )' expr: "float(payload.FLT)" "value_sensor.god": json_payload: true if_expr: '! isnull( payload?.GOD )' expr: "float(payload.GOD)" "value_sensor.lock": json_payload: true if_expr: '! isnull( payload?.LCK )' expr: "float(payload.LCK)" "value_sensor.unit": json_payload: true if_expr: '! isnull( payload?.UNT )' expr: "float(payload.UNT)" "value_sensor.error": json_payload: true if_expr: '! isnull( payload?.ERR )' expr: "float(payload.ERR)" "temperature_sensor.green": json_payload: true if_expr: '! isnull( payload?.GRN )' expr: "float(payload.GRN)" "temperature_sensor.red": json_payload: true if_expr: '! isnull( payload?.RED )' expr: "float(payload.RED)" "temperature_sensor.target": json_payload: true if_expr: '! isnull( payload?.TGT )' expr: "float(payload.TGT)" "temperature_sensor.value": json_payload: true if_expr: '! isnull( payload?.TMP )' expr: "float(payload.TMP)" "temperature_sensor.virtual": json_payload: true if_expr: '! isnull( payload?.VTM )' expr: "round(float(payload.VTM), 1)" "temperature_sensor.ambient": json_payload: true if_expr: '! isnull( payload?.AMB )' expr: "float(payload.AMB)" "layzspa/Status": "value_sensor.status": if_expr: '! isnull( payload )' expr: "payload" "layzspa/button": "value_sensor.button": if_expr: '! isnull( payload )' expr: "payload" and in reactor.yaml I have: "layzspa_states": name: "Lay-Z-Spa States" friendly_name: 'Lay-Z-Spa States' include: layzspa_message I realize my MQTT configuration might be a bit unorthodox, but could there still be something unintentional in the latest MQTTController build? If needed, I can provide detailed logs.
Multi-System Reactor
🎉 My very first MSR controller: OpenSprinkler
therealdbT
Since today is my birthday - and I still pretend to be unconventional - I'm giving away a present to this wonderful community and I'm releasing my first OpenSprinkler controller for MSR. It was real fun to code it - and while it's still WIP, it seems to work OK for me. It's polling-based at the moment, but I'll add support for updates via MQTT very soon (it's already partially coded). Get it at (install is similar to MQTTController and such): https://github.com/dbochicchio/reactor-opensprinkler Feel free to try it. It's beta software, but it's stable. I'll update it weekly until all the tasks from my todo list are empty. Since I've learnt a lot from this controller, I'll explore new controllers soon.
Multi-System Reactor
Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor

Need help reducing false positive notifications

Scheduled Pinned Locked Moved Multi-System Reactor
7 Posts 3 Posters 728 Views 3 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • T Offline
    T Offline
    tamorgen
    wrote on last edited by tamorgen
    #1

    Good day all,
    I have an notification set up for my washing machine to let me know when it's complete. I have a templete sensor set up in HAAS to let me know if it's Washing, in Standby, or off, based upon the power consumption (Shelly 1PM on outlets)

      - name: "Washing Machine"
        state: >
          {% if states("sensor.washer_switch_0_power")|float == 0  %}
            Off
          {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %}
            Standby
          {% else %}
            Washing
          {% endif %}
        icon: >
          {% if states("sensor.washer_switch_0_power") == "off"  %}
          mdi:washing-machine-alert
          {% elif states("sensor.washer_switch_0_power")|float <= 2.9  %}
          mdi:washing-machine-off
          {% else %}
          mdi:washing-machine
          {% endif %}
            minutes: 2
    

    The MSR code is relatively simple. I have a built in false positive attribute for if MSR gets rebooted, because I would suddenly get tons of notifications when I upgraded MSR.

    6774565a-06cc-443f-99c1-e71301b33d83-image.png

    What I'm trying to introduce, is a way to verify that I just didn't bump the knob on the washing machine when transferring loads from the washer to the dryer, which turns on the display and brings the power above the Standby threshold.

    The power goes up to 3.7W for about 4 minutes if the selector knob is bumped/turned.

    What would the best way to do this be? I have most of my MSR code set up for a couple of years now, and my coding logic is struggling a bit.

    I think I need a power threshold to be substained for a minimum time period (say 2 or 3 minutes, above 10W), before the other triggers can act. What would the best way to do that be?

    Running: latest-25082-3c348de6
    Fedora 41 Server
    HAAS:
    Core
    2025.3.4
    Supervisor
    2025.03.4
    Operating System
    15.1
    Frontend
    20250306.0

    1 Reply Last reply
    0
    • T Offline
      T Offline
      tamorgen
      wrote on last edited by
      #2

      Any thoughts? I know I can set up a a condition to monitor the power sensor value, and make sure it is above 3.5 for 5 minutes, but the condition I need is for the power value to go to the standby value of under 2.9 after that condition is met. That's what I'm unclear how to do.

      toggledbitsT 1 Reply Last reply
      0
      • therealdbT Offline
        therealdbT Offline
        therealdb
        wrote on last edited by therealdb
        #3

        I haven't moved this particular piece into MSR yet, but my logic is:

        • watch for idle: if watts<5 for at least 15 secs, that's done. If previous status is running, mark as completed. Otherwise, stays idle.
        • watch for watts. if idle and watts > 50 for at least 15 secs, that's running.

        I think the best way to achieve this is by having two different rules. I'll probably design it with a virtual device with a string_sensor, containing the current state. I've never moved this part of my system to MSR, because I want to write a controller doing exactly this, but the logic is not complex.

        --
        On a mission to automate everything.

        My MS Reactor contrib
        My Luup Plug-ins

        1 Reply Last reply
        0
        • T tamorgen

          Any thoughts? I know I can set up a a condition to monitor the power sensor value, and make sure it is above 3.5 for 5 minutes, but the condition I need is for the power value to go to the standby value of under 2.9 after that condition is met. That's what I'm unclear how to do.

          toggledbitsT Offline
          toggledbitsT Offline
          toggledbits
          wrote on last edited by
          #4

          @tamorgen said in Need help reducing false positive notifications:

          Any thoughts? I know I can set up a a condition to monitor the power sensor value, and make sure it is above 3.5 for 5 minutes, but the condition I need is for the power value to go to the standby value of under 2.9 after that condition is met. That's what I'm unclear how to do.

          Look at the condition options (for any condition). You'll see the ability to sequence conditions there -- set a condition so it can only go true after another condition has gone true.

          Your problem seems simpler to me, though. Maybe I just don't get the full scope from what you wrote, but what you asked for can be done without sequencing.

          If you just want to know if the machine is running, make a rule for power >5W (your 3.7W plus some headroom) sustained for at least 5 minutes (see condition options again). If you want to know if the machine is not running, make a rule for (guessing) power < 15W sustained for 5 minutes. I think you'll find these pretty effectively ignore the transitions between cycles and bumps at the controls or door left open (light on) if you get the power values right for your machine's behavior.

          Now you have two rules, one to tell you that it appears to be idle, and the other that it appears to be running. We could use one rule, but by using two rules with a gap between the power values, we create additional hysteresis to prevent those false positives. For you rules that need to react to the machine going idle, use a Rule State condition to check your idle rule; for rules that need to react to the machine running, check the running rule.

          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

          T 1 Reply Last reply
          0
          • toggledbitsT toggledbits

            @tamorgen said in Need help reducing false positive notifications:

            Any thoughts? I know I can set up a a condition to monitor the power sensor value, and make sure it is above 3.5 for 5 minutes, but the condition I need is for the power value to go to the standby value of under 2.9 after that condition is met. That's what I'm unclear how to do.

            Look at the condition options (for any condition). You'll see the ability to sequence conditions there -- set a condition so it can only go true after another condition has gone true.

            Your problem seems simpler to me, though. Maybe I just don't get the full scope from what you wrote, but what you asked for can be done without sequencing.

            If you just want to know if the machine is running, make a rule for power >5W (your 3.7W plus some headroom) sustained for at least 5 minutes (see condition options again). If you want to know if the machine is not running, make a rule for (guessing) power < 15W sustained for 5 minutes. I think you'll find these pretty effectively ignore the transitions between cycles and bumps at the controls or door left open (light on) if you get the power values right for your machine's behavior.

            Now you have two rules, one to tell you that it appears to be idle, and the other that it appears to be running. We could use one rule, but by using two rules with a gap between the power values, we create additional hysteresis to prevent those false positives. For you rules that need to react to the machine going idle, use a Rule State condition to check your idle rule; for rules that need to react to the machine running, check the running rule.

            T Offline
            T Offline
            tamorgen
            wrote on last edited by
            #5

            @toggledbits ,
            Patrick,
            This is what I had come up with. I tried using latch:

            fa20b886-f1a1-48af-bdc2-00a76a33da4d-image.png

            The problem I ran into, is the latch condition went true after 5 minutes, and it stayed true all the way until the first condition changed, then it went false. so the "and" of the 3 conditions never becomes true. It's like I need the latch condition to stay true for 5 seconds longer.

            I hadn't considered two rules, but I'll see if I can figure out what you mean. The sensor switch I have made within HAAS already is sort of a rule as you described, as it looks for the power to be above 2.9W, which is the minimum value I recorded over a wash cycle, as it pauses within the cycle. The 3.7W value comes from when the control panel is turned on by turning or pumping the cycle selector switch, so what happens is that it does set the sensor to Washing when the control panel is turned on, if you follow.

            toggledbitsT 1 Reply Last reply
            0
            • T tamorgen

              @toggledbits ,
              Patrick,
              This is what I had come up with. I tried using latch:

              fa20b886-f1a1-48af-bdc2-00a76a33da4d-image.png

              The problem I ran into, is the latch condition went true after 5 minutes, and it stayed true all the way until the first condition changed, then it went false. so the "and" of the 3 conditions never becomes true. It's like I need the latch condition to stay true for 5 seconds longer.

              I hadn't considered two rules, but I'll see if I can figure out what you mean. The sensor switch I have made within HAAS already is sort of a rule as you described, as it looks for the power to be above 2.9W, which is the minimum value I recorded over a wash cycle, as it pauses within the cycle. The 3.7W value comes from when the control panel is turned on by turning or pumping the cycle selector switch, so what happens is that it does set the sensor to Washing when the control panel is turned on, if you follow.

              toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by
              #6

              @tamorgen Frankly, it looks like you've made an overly simplistic sensor that you're trying to improve on in the rule... you're taking a low-res image of the device and trying to make it back into something higher-res.

              I'd just look at the power directly in Reactor:

              46f847d7-6b73-4bcd-9151-fee570153cc8-image.png

              c3f94ddc-050e-4692-b663-d1d9ad530432-image.png

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              T 1 Reply Last reply
              0
              • toggledbitsT toggledbits

                @tamorgen Frankly, it looks like you've made an overly simplistic sensor that you're trying to improve on in the rule... you're taking a low-res image of the device and trying to make it back into something higher-res.

                I'd just look at the power directly in Reactor:

                46f847d7-6b73-4bcd-9151-fee570153cc8-image.png

                c3f94ddc-050e-4692-b663-d1d9ad530432-image.png

                T Offline
                T Offline
                tamorgen
                wrote on last edited by tamorgen
                #7

                @toggledbits,

                I tried to go about the way you mentioned, but I don't think it was quite suited for my purpose. The purpose of the rule is to send a notification through Home Assistant to my phone, and I didn't want a delay that I believe your method would have introduced. What I came up with was creating a global variable and a helper rule, that sets the global variable to true when the 300 seconds is exceeded of power being above 3.7.

                b0f50fcc-a06f-49a6-9ccb-38f718d7cc42-image.png

                88547953-dbd8-4646-80a9-48b03a6c09ad-image.png

                Then there is a Variable Value check in the Triggers of the Notification rule:
                8b91b3c4-cc46-44db-a4f1-a76408f7c79b-image.png

                The Reaction resets the Global rule back to false, after the cycle is completed.

                It may not be the most elegant method, but it reduces the false positives on my phone when the cycle selector is bumped. For the same reason, I have the reactor uptime checked, because I would get tons of notifications on my phone when I did an update to MSR, or when my server was rebooted. I know I could completely encapsulate the logic within MSR, but the overly simplistic sensor in HAAS serves it's own purpose in HAAS for my dashboard, and HAAS can't read rule states from MSR, so for my purpose, I already have the simple sensor in place, so why reinvent the wheel?

                1 Reply Last reply
                0
                Reply
                • Reply as topic
                Log in to reply
                • Oldest to Newest
                • Newest to Oldest
                • Most Votes


                Recent Topics

                • Gradually turn on lights.
                  G
                  gwp1
                  0
                  4
                  77

                • Stop the MSR by an external switch on Hubitat.
                  wmarcolinW
                  wmarcolin
                  0
                  1
                  12

                • Error After Upgrade
                  G
                  gwp1
                  0
                  4
                  78

                • Reset attribute value of entity in event handler
                  R
                  RHCPNG
                  0
                  5
                  151

                • Need help figuring out how to delay a reset on reaction
                  G
                  gwp1
                  0
                  22
                  811

                • Way to search for rules (rule state) in other rules
                  T
                  tamorgen
                  0
                  3
                  78

                • Links to MSR from HA
                  Tom_DT
                  Tom_D
                  0
                  1
                  72

                • Set Reaction > Script Action
                  wmarcolinW
                  wmarcolin
                  0
                  11
                  401

                • Wiring Samotech SM308-S into light fitting
                  akbooerA
                  akbooer
                  0
                  2
                  128

                • Errors after updating to MQTTController build 25139
                  toggledbitsT
                  toggledbits
                  0
                  6
                  230

                • 🎉 My very first MSR controller: OpenSprinkler
                  therealdbT
                  therealdb
                  5
                  13
                  892

                • Advice reqeusted to migrate MSR from Bare Metal to Container
                  T
                  tamorgen
                  0
                  5
                  239