Thanks to @toggledbits for adding a custom CSS. I've started doing a darker Reactor style.
Here's the file: https://gist.github.com/dbochicchio/825098ac13b7f8cac22012eae37ff7ce
A couple of things are still too bright and I'll eventually catch-up. Just place it under your /config directory, naming the file as customstyles.css. Hard refresh your browser.
Hi
I have just connected a bunch of EzloPi controllers to MSR to import some ESP based devices etc.
They all seemed to have worked and imported in to MSR apart from I have one missing device. It is a Digital Gas Sensor device.
This is how that device looks in the Ezlo API.
Devices Info:
_id: "10696001" deviceTypeId: "ezlopi" parentDeviceId: "10696000" category: "level_sensor" subcategory: "" gatewayId: "457a5069" batteryPowered: false name: "Gas Sensor Digital" type: "sensor" reachable: true persistent: true serviceNotification: false armed: false roomId: "" security: "no" ready: true status: "idle" parentRoom: true protectConfig: "default"Items Info:
_id: "20696001" deviceId: "10696001" hasGetter: true hasSetter: false name: "smoke_density" show: true valueType: "substance_amount" scale: "parts_per_million" value: 2.7472610473632812 valueFormatted: "2.75" status: "idle"There is also an Analog Gas sensor that one did import in to MSR OK.
68d63dab-b871-4f44-912b-cf6e0b9eb4c6-image.png
Devices Info:
_id: "10696000" deviceTypeId: "ezlopi" parentDeviceId: "10696000" category: "security_sensor" subcategory: "gas" gatewayId: "457a5069" batteryPowered: false name: "Gas Sensor Analog" type: "sensor" reachable: true persistent: true serviceNotification: false armed: false roomId: "" security: "no" ready: true status: "idle" parentRoom: true protectConfig: "default"Items Info:
_id: "20696000" deviceId: "10696000" hasGetter: true hasSetter: false name: "gas_alarm" show: true valueType: "token" enum: 0: "no_gas" 1: "combustible_gas_detected" 2: "toxic_gas_detected" 3: "unknown" valueFormatted: "no_gas" value: "no_gas" status: "idle"And this is how this MQ2 Gas Sensor looks like on their dashboard:
Digital
cb77dfa3-4af5-4d06-9635-89207a716a89-image.png
Analog
4fb4da1b-e946-4b89-876c-bcd9f5699b6c-image.png
They have an EzloPi website here you can create your own sensor projects using ESP boards, which is very interesting stuff!
And I just wrote on the Ezlo forum here, how to connect an EzloPi controller to MSR.
THANKS.
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.Hi @toggledbits,
I have lots of logs with this:
<Engine:ERR> Assignment to alarm ignored -- expression-driven global cannot be set by assignmentAny hints to where look at to avoid this? Thanks.
A couple of things for you @toggledbits, since you mentioned that this release has new features and some tweaks are expected.
Local expressions cannot be deleted. Pushing the X button has no effect for me.
When cloning an entity action, the result is strange (first is cloned one, second is the original action):
a92ea094-9e2c-4aaa-bf47-2d07a6ffdbd0-image.png
When changing the action on the cloned element, the params are added to the original one. See screenshot:
92ac3011-83c8-466b-bd23-47d483ad7a52-image.png
Dark theme has a couple of strange contrasts. One is visible in the previous screenshots (white text on yellow background). Another one is in groups (blue text on blue background):
9b3c4988-53ef-44e6-9672-30e744cacb75-image.png
Overall, I found blue, yellow, red and green (in buttons and forms) to be too bright.
On the bright side:
I love the new script action: thank you! The dark theme is a great start to avoid getting blinded at night I promise I'll try very soon the new features around actions. Thanks!@toggledbits
I just upgraded to version MSR 24293, bare metal running on Fedora. Upon restart, I am getting a error banner:
I followed the new directions about npm
npm i --no-save --no-package-lock --omit dev
Any idea what the issue is?
Seems like switching the UI to the newly added dark mode (thank you for this) does nothing. The UI stays in light mode and only a few buttons turn into dark mode (see screenshot)
Things I have tried:
Hard refresh
Different browser
Different computer
Restarting Reactor
Failed troubleshooting attempts:
No errors in Chrome console
No relevant errors in Reactor log (can still PM the full log file)
Reactor version: latest-24293-ea42a81d
Hardware: Odroid N2+
Linux version: Ubuntu 24.04.1 LTS
3df2806f-9146-485b-9ec1-d056e91cefe5-image.png Dark mode enabled
ff823023-c079-4684-b01f-d6ac6527d31a-image.png Light mode enabled
Good morning,
I have a service MQTT service that needs a restart occasionally. The add-on (Smartbed MQTT) is for the smart bed base for my bed. It has a "safety light" that I can control from HAAS & MSR as a light entity, and also moves the head of the bed to a preset at bedtime, and then lies it back flat in the morning The problem is, from time to time, the light becomes "unavailable" Restarting from the Add-ons tab in HAAS always fixes it, but I should be able to detect when it happens when "light.tempur_pedic_safety_lights" is not true or false, i.e., unavailable.
What I don't know how to do is how to restart that service. Does anybody have experience in restarting add-ons from MSR?
Running:
Reactor (Multi-hub) latest-24212-3ce15e25 ZWaveJSController [0.1.24232]HAAS:
RPi5-64 (8GB) Core 2024.7.3 Supervisor 2024.08.0 Operating System 13.0 Frontend 20240710.0Hi!
Is it possible to generate two additional log files, the first being the replica of what is displayed on screen by the Rule History widgets and the other with Recently Changed Entities?
And could I configure the generation of one file per day, and delete the older ones? For example, store the last 5 days?
And being more ambitious, does Windget have an icon to open these TXT files in the navigated?
Well, we're approaching Christmas, so here's my request to Santa Claus @toggledbits 🙂
Hi @toggledbits
I'm working on a controller to generate llm response from a prompt in reactor. I have http response coming thru an http request action at the moment, capturing the response inside a local variable. So, it's practically sync.
I want to create a controller, so I don't have to rely on a proxy (and have a simpler architecture), and duplicate absurd http actions, but AFAIK in the current implementation, actions are async only. But if I have multiple requests going on, I cannot be sure what it's really inside an attribute. I also thought that something like a correlation id when sending the request could be used to identity multiple responses, but I wanted to double check with you before starting with something too complicated. I also noticed that some actions in home assistant (ie forecast) are sync and I'm wondering if you have any plan or hint to address this situation. Thanks.
Thanks.
@togglebits I am curious as to why the tilt_sensor.state (primary) = NULL. I believe it should show true or false. I have to use binary_sensor.state instead in my rules.
Again, not sure if this is related to Reactor/ZwaveJSController implementation or the actual Z-Wave JS UI docker version. I have copied, below, the attributes of the tilt sensor in hopes it can help.
Thanks in advance.
Reactor version 23302
ZWaveJSController version 23254
Z-Wave JS UI version 9.3.0.724519f
zwave-js version 12.2.3
@toggledbits I have noticed after upgrading both Reactor and ZWaveJSController to version 24257 that two of my devices/entities, TILT-ZWAVE2.5-ECO and Zooz ZSE18, had their entity re-named in an unusual way and also appears to be duplicated.
Reactor version 24257
ZWaveJSController version 24257
Z-Wave JS UI version 9.18.1
zwave-js version 13.2.0
Vestibule Motion Sensor State attributes/partial screenshot of entities it created. All entities have the same attributes.
motion_sensor.state=true x_zwave_values.Notification_Home_Security_Motion_sensor_status=8 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=23 zwave_device.valueId=[113,"Notification","Home Security","Home Security","Motion sensor status","Motion sensor status"] zwave_device.version_info=nullTilt Sensor Door State and Tilt Sensor Door State Simple attributes/partial screenshot of entities it created. All entities have similar attributes with exception of x_zwave_values.Notification_Access_Control_Door_State = 22 or 23.
tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=true x_zwave_values.Notification_Access_Control_Door_state_simple=22 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state","Door state"] zwave_device.version_info=null tilt_sensor.state=false x_zwave_values.Notification_Access_Control_Door_state_simple=23 zwave_device.capabilities=[113] zwave_device.endpoint=0 zwave_device.failed=null zwave_device.manufacturer_info=null zwave_device.node_id=24 zwave_device.valueId=[113,"Notification","Access Control","Access Control","Door state (simple)","Door state (simple)"] zwave_device.version_info=nullI'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only).
Anyway, here's my reactor-mqtt-contrib package:
Contrib MQTT templates for Reactor. Contribute to dbochicchio/reactor-mqtt-contrib development by creating an account on GitHub.
Simply download yaml files (everything or just the ones you need) and you're good to go.
I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them.
The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression.
Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests 🙂
Hi @toggledbits.
After a couple of weeks, I noticed that my Remotec zrc90 isn't working as expected.
Scenes are working in ZWaveJS, but this device has a strange behavior: the scene change, but then it's set again to null. In Reactor, this remains null:
battery_power.level=0.7 battery_power.since=1725817957361 x_debug.dt={"description":"Scene master 8 button remote","model":"BW8510/ZRC-90US","default_name":"Scene master 8 button remote","manufacturerId":21076,"productType":0,"productId":34064} x_zwave_values.Battery_isLow=false x_zwave_values.Battery_level=70 x_zwave_values.Central_Scene_scene_001=null x_zwave_values.Central_Scene_scene_002=null x_zwave_values.Central_Scene_scene_003=null x_zwave_values.Central_Scene_scene_004=null x_zwave_values.Central_Scene_scene_005=null x_zwave_values.Central_Scene_scene_006=null x_zwave_values.Central_Scene_scene_007=null x_zwave_values.Central_Scene_scene_008=null x_zwave_values.Central_Scene_slowRefresh=null x_zwave_values.Manufacturer_Specific_manufacturerId=21076 x_zwave_values.Manufacturer_Specific_productId=34064 x_zwave_values.Manufacturer_Specific_productType=1 x_zwave_values.Version_firmwareVersions=["1.1","1.1"] x_zwave_values.Version_hardwareVersion=3 x_zwave_values.Version_libraryType=2 x_zwave_values.Version_protocolVersion="4.5" x_zwave_values.Wake_Up_controllerNodeId=1 x_zwave_values.Wake_Up_wakeUpInterval=0 zwave_device.capabilities=[91,114,128,132,134] zwave_device.endpoint=0 zwave_device.failed=false zwave_device.generic_class="Remote Controller" zwave_device.impl_sig="24242:1:22315:1" zwave_device.is_beaming=false zwave_device.is_listening=false zwave_device.is_routing=false zwave_device.is_secure=false zwave_device.manufacturer_info=[21076,1,34064] zwave_device.max_data_rate=null zwave_device.node_id=154 zwave_device.specific_class="Simple Remote Control" zwave_device.status=2 zwave_device.status_text="awake" zwave_device.version_info=[null,"1.1"] zwave_device.wakeup_interval=0Anything I could look at? Thanks.
Hi, @toggledbits!
I have a question about the execution behavior. See the code below, and I'll explain the situation.
12957c3e-ff06-46c9-929d-b53f936665df-image.png
This is a routine that, at a certain point, determines that the desktop on which the VM hosting the Reactor is located receives an instruction to perform a shutdown (Shell Command).
When this happens, the desktop is turned off, and then Hubitat detects by a "ping" that the VM has been down, waits 15 seconds, turns off the power to this desktop, and then 15 seconds later turns on the desktop with the Reactor VM again.
After restarting the desktop, the VM is loaded, and the Reactor is triggered. Still, the following problem occurs: I expected that when the rule was continued to be executed again, the next step would be executed, that of the 900-second delay after shutdown, but the Shell command is executed again, and then it goes into a loop, the rule does not advance.
To break the loop, I first have to make the VM not load, change the desktop password, and then start the VM. In this case, Reactor generates an error when trying to execute the Shell Command because of the invalid password and then finishes the routine following the 900 delay step.
b58b0d4a-d6c1-4fe3-bab7-4222acea9607-image.png
Is my interpretation that when it returns, the routine should continue to the next step that has not yet been executed incorrectly? Or does Reactor, through the shutdown command, interpret that it hasn't finished this step and keep trying, which is the correct reaction?
Thanks for clarifying.
Hi @toggledbits ,
I'm slowly moving my ZWave network from Vera to ZWaveJS. I successfully cloned my ZWave network using a spare Vera Edge (a new post for the community later when I'll be fully back from vacation) and I'm testing a couple of things before moving everything to ZWaveJS.
In the meanwhile, I have a couple of venetian blinds connected to Fibaro Roller Shutters 2 (FGR222) and I'm using some proprietary ZWave commands to control the tilt position, that right now I'm sending via Vera (with some code from the old place, messing with this):
af7f883c-f49e-419c-a2fe-8669572e3792-image.png
The ZWaveJS values are reported via this:
x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsPosition=0 x_zwave_values.Manufacturer_Proprietary_fibaro_venetianBlindsTilt=0I hope there's a way to expose a separate device to control the tilt position directly, without doing the mess I'm doing now. Let me know if you need some files. Thanks.
As per @toggledbits request, new topic.
Position and cover commands not working and position/cover attributes are incorrect. Dimming is OK.
cover.state=null dimming.level=1 dimming.step=0.1 energy_sensor.units="kWh" energy_sensor.value=0.41 position.value=null power_sensor.units="W" power_sensor.value=0 power_switch.state=true x_debug.dt={"entity_class":"Cover","match":"deviceClass.generic.key=17;deviceClass.specific.key=6","capabilities":["cover","toggle","position"],"primary_attribute":"cover.state"} x_zwave_values.Meter_reset=null x_zwave_values.Meter_value_65537=0.41 x_zwave_values.Meter_value_66049=0 x_zwave_values.Multilevel_Switch_Down=null x_zwave_values.Multilevel_Switch_Up=null x_zwave_values.Multilevel_Switch_currentValue=99 x_zwave_values.Multilevel_Switch_duration="unknown" x_zwave_values.Multilevel_Switch_restorePrevious=null x_zwave_values.Multilevel_Switch_targetValue=99 x_zwave_values.Notification_Power_Management_Over_current_status=0 x_zwave_values.Notification_System_Hardware_status=0 x_zwave_values.Notification_alarmLevel=null x_zwave_values.Notification_alarmType=null zwave_device.capabilities=[38,50,113] zwave_device.endpoint=1 zwave_device.failed=null zwave_device.impl_sig="24225:1:22315:1" zwave_device.manufacturer_info=null zwave_device.node_id=148 zwave_device.version_info=nullThanks!
Running Lua Code ? And watching device properties?
-
If that's the case, it probably goes haywire when the scene are run from the Vera UI as well, since MSR and the Vera UI use the same mechanism to start the scene. In fact, pretty much everything MSR does with Vera is enabled by the same mechanisms that the Vera UI (and Imperihome, etc.) use. There's nothing MSR can do to mess up those scenes. It just asks that they run.
I would start at the Vera UI scenes tab for troubleshooting. Lua code on Vera can be very particular, as you know. Long delays will cause deadlocks and reloads. If you're opening sockets or making HTTP requests without appropriate timeouts and error handling, you're going to get into trouble. If you open sockets or files and are not taking steps to close them properly in all conditions, even when errors occur, you're going to exhaust limited resource handles and cause a reload or even a reboot. You really need to understand and know what you're doing, and unfortunately, there's just a lot of bad Lua copy-pasta on the forums.
-
@toggledbits said in Running Lua Code ? And watching device properties?:
How are you running the scene?
I opened a PR with screen shot.
-
Well least you can run the Vera scenes I cannot at the moment.
I see these in the MSR log:
VeraController:ERR [VeraController:performOnEntity] action request failed
VeraController:CRIT Error: Request failed: 401 Error -
I understand and I will try to test keeping MSR out of the equation. Having said that the same lua in Vera reactor did not cause any issues. What i will do is take a segmented approach and not try to finish the complete MSR project at once. If I hit trouble i will try to remedy as well as I can. I am not a coder, not great at understanding code syntax. I am good at the logical part or reactor just not lua and coding in general. I have no idea whether my code is up to par or not. It was created by copying and pasting peoples samples from the forums with some modification that I picked up from online tutorials etc. All i know is is seems to work in Vera Reactor. My Vera reactor setup is quite complex and there is a lot going on. Is running a scene outside of reactor a true test absent of the other things reactor is doing concurrent to running a scene via Vera reactor or MSR? I will try with whatever skills I can muster up but when it comes down to it and speaking of Vera Reactor and my conditional logic needs if it isn't broken dont' fix it or at least dont go crazy trying to.
-
@tarkus said in Running Lua Code ? And watching device properties?:
In preliminary testing the big issue I see with lua in Vera scenes is stability. I tried moving some of my lua into scenes and invoking the scenes thru MSR and everything just became real unstable with Luup restarts.
I think you already discovered the problem. Running the lua through scenes is probably not a good idea. Have you attempted what was suggested by @therealdb in this thread defining a library at startup and calling your lua through that? IMO this is the correct way to do it.
-
@cw-kid said in Running Lua Code ? And watching device properties?:
VeraController:ERR [VeraController:performOnEntity] action request failed
VeraController:CRIT Error: Request failed: 401 ErrorHave you looked at the Vera log corresponding to the time to see what it's logging? Also what happens when you run it via the Vera UI?
-
luvd_get_info_data_request starting /data_request?SceneNum=null&DeviceNum=86&id=action&serviceId=urn%3Amicasaverde-com%3AserviceId%3AHomeAutomationGateway1&action=RunScene&output_format=json&_r=1614868227818 pMem 0x3473000/54996992 diff: 39190528 <0x6cd27520> 08 03/04/21 14:30:27.829 JobHandler_LuaUPnP::HandleActionRequest device: 0 service: urn:micasaverde-com:serviceId:HomeAutomationGateway1 action: RunScene <0x6cd27520> 08 03/04/21 14:30:27.829 JobHandler_LuaUPnP::HandleActionRequest argument SceneNum=null <0x6cd27520> 08 03/04/21 14:30:27.829 JobHandler_LuaUPnP::HandleActionRequest argument DeviceNum=86 <0x6cd27520> 08 03/04/21 14:30:27.830 JobHandler_LuaUPnP::HandleActionRequest argument serviceId=urn:micasaverde-com:serviceId:HomeAutomationGateway1 <0x6cd27520> 08 03/04/21 14:30:27.830 JobHandler_LuaUPnP::HandleActionRequest argument action=RunScene <0x6cd27520> 08 03/04/21 14:30:27.831 JobHandler_LuaUPnP::HandleActionRequest argument _r=1614868227818 <0x6cd27520> 02 03/04/21 14:30:27.831 JobHandler_LuaUPnP::RunAction device -1 action urn:micasaverde-com:serviceId:HomeAutomationGateway1/RunScene failed with 401/Invalid Scene <0x6cd27520>
Strange it says its an invalid scene.
"Fan On" is scene number 86 in Vera and that is the scene I selected to run in my "Set Reaction" run script.
If I run the "Fan On" scene actually in Vera on the UI7 web GUI it works the scene runs OK.
Why does it have a device number and scene number is null ?
SceneNum=null&DeviceNum=86
-
@tarkus That helps. Open a PR. The scene ID isn't being passed correctly. That's a quick fix you can do in place in a minute. I'll post what you need on the PR.
-
@toggledbits said in Running Lua Code ? And watching device properties?:
The scene ID isn't being passed correctly
You talking to me ?
There is a PR open already.
-
Both, and yes, I see the PR. I hadn't looked at my email or Mantis yet this morning, still getting off the ground here, so I didn't see it get opened. All good and thank you. Discussion on that thread shortly.
-
FYI, I'm also trying to implement the "run lua" action for the (vera-specific) system device. That does not mean Lua will run in MSR -- it does not, can not, and will not. But Vera does give me the ability to pass it Lua and have it execute it. That fills me with dread, frankly, but if it's what you need, it can be done. It will also need a UI change to support it, since typing Lua into a small entry field won't due. If it works, it should make invoking functions in a Lua module (built as @therealdb has shown you to do) pretty easy.
-
Update, if you haven't already been notified by Mantis: patch is up on PR#80.
-
@toggledbits said in Running Lua Code ? And watching device properties?:
FYI, I'm also trying to implement the "run lua" action for the (vera-specific) system device. That does not mean Lua will run in MSR -- it does not, can not, and will not. But Vera does give me the ability to pass it Lua and have it execute it. That fills me with dread, frankly, but if it's what you need, it can be done. It will also need a UI change to support it, since typing Lua into a small entry field won't due. If it works, it should make invoking functions in a Lua module (built as @therealdb has shown you to do) pretty easy.
I'm sure this will be very handy for some users.
I am good at the moment however, using the method therealdb showed me. Its working currently.
-
@toggledbits said in Running Lua Code ? And watching device properties?:
Update, if you haven't already been notified by Mantis: patch is up on PR#80.
Confirmed as working again thanks.