S

sammy2

@sammy2
Disaster recovery and virtualisation
CatmanV2C

Following on from my last thread, some progress has been made over the weekend.

With 18G of spanky RAM in my Synology DS224+. I've jumped into the murky world of virtualisation and already eliminated the need for two Raspberry Pi's from my system.

Home Assistant: In theory they provide an OVA file which is supported by the Synology. I couldn't get it to work, however, so grabbed a copy of the .img file they supply, renamed it .iso and imported it as a VM. Restored from my full back up and that all seems fantastic.

Minidnla Music server: Trivial. Grabbed a Debian .iso for Bookworm and copied that onto the NAS. Created a new machine which mirrored the specs of the Raspberry Pi, booted from the ISO then did an expert install. Once that was all stable with a basic core of stuff and networking, I've made a copy of that as a good base system. Then fired up minidnla on it, mounted my media and that's also woking. Not bad for a short weekend's work.

Still not sure about the main NUC though. I'm thinking of buying a new USB stick so I can mess around getting it working on the Synology before I do anything drastic.

Once that hurdle is sorted I'm torn between:

Using a brand new install of Bookworm, re-installing Z-way server, OpenLuup, AltUI, MSR and HA bridge, then restoring across or Making an ISO of the current system, importing that and upgrading in place (which will be pretty risk free since I can snapshot everything before I make any changes.)

Decisions, decisions.

C

General Discussion
Remote access of Zwave stick from Z-wave server
CatmanV2C

Afternoon, all.

In my continued attempts to virtualise my system, I'm in the last (I hope throes)

I don't fancy relying on Synology not to break more USB activities, so decided to set up ser2net on a Raspberry pi and plug in a spare Z-wave.me stick

So on the Raspberry pi: ser2net. yaml

catman@Zwave:/etc $ cat ser2net.yaml %YAML 1.1 --- # This is a ser2net configuration file, tailored to be rather # simple. # # Find detailed documentation in ser2net.yaml(5) # A fully featured configuration file is in # /usr/share/doc/ser2net/examples/ser2net.yaml.gz # # If you find your configuration more useful than this very simple # one, please submit it as a bugreport define: &banner \r\nser2net port \p device \d [\B] (Debian GNU/Linux)\r\n\r\n connection: &zwave0 # Bind to TCP port accepter: tcp,4000 enable: on options: kickolduser: true # Ensure mDNS is disabled mdns: false connector: serialdev, /dev/ttyACM0,115200N81,nobreak,local

And if I telnet to it from anywhere:

catman@ChrisMBP15-2018 ~ % telnet 192.168.70.128 4000 Trying 192.168.70.128... Connected to 192.168.70.128. Escape character is '^]'.

Which makes me think that ser2net is doing its thing.

Now in my virtualised Z-wave server I have this:

Screenshot 2025-04-10 at 17.36.52.png

(I've tried with a colon and a space between the ip and the port)

The result:

An unexpected error occurred during loading data. Try to reload the page. Please check 1.) if the controller is plugged in correctly, 2.) that in the app 'Z-Wave Network Access' the right port is entered (UZB: '/dev/ttyACM0', RaZberry shield: '/dev/ttyAMA0', UZB-Windows: '\\.\COM3', Z-Stick: '/dev/ttyUSB0', embedded boxes: '/dev/ttyS0' or '/dev/ttyS1') 3.) the app is aktiv. If not you could activate it under Menu > Apps > Active or add a new one under Menu > Apps > Local. The Setting 'Expert View' needs to be active under Menu > My Settings.

Any pointers as to what I'm doing wrong?

TIA!

C

Software
Organizing/ structuring rule sets and rules
R

Hi guys,

Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular.

Maybe there are better ways to organize my rule sets.

I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.

Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT

I have installed MSR on a RP5 bare metal and then copied the config and store files. Everything seems to be on the RP5 but I am missing all global expression and I don't see the controller time.

Screenshot 2025-04-06 201446.png

My browser is Microsoft Edge Version 135.0.3179.54 (Official build) (64-bit)

I have probably done something stupid or missed a step but I am stuck.

Thanks for any help.

Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M

Hi,
It seems that the widget deletion does not work. I tried to drag the widget to the left (as explained in here https://smarthome.community/topic/1071/deleting-widgets?_=1744037333660)
but it does not delete it. Anyone else experiencing the same problem?

Also the landing page after login is empty and seems be have some JS issues on the dev console:

Screenshot from 2025-04-07 18-06-19.png

fd7f0424-debb-49d3-86d8-9a3b09ad3868-image.png

Using dockerized version of Reactor (Multi-hub) latest-25082-3c348de6 on Chromium 135.0.7049.52 (Official Build) snap (64-bit)

br,
mgvra

Multi-System Reactor
Need help reducing false positive notifications
T

Good day all,
I have an notification set up for my washing machine to let me know when it's complete. I have a templete sensor set up in HAAS to let me know if it's Washing, in Standby, or off, based upon the power consumption (Shelly 1PM on outlets)

- name: "Washing Machine" state: > {% if states("sensor.washer_switch_0_power")|float == 0 %} Off {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %} Standby {% else %} Washing {% endif %} icon: > {% if states("sensor.washer_switch_0_power") == "off" %} mdi:washing-machine-alert {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %} mdi:washing-machine-off {% else %} mdi:washing-machine {% endif %} minutes: 2

The MSR code is relatively simple. I have a built in false positive attribute for if MSR gets rebooted, because I would suddenly get tons of notifications when I upgraded MSR.

6774565a-06cc-443f-99c1-e71301b33d83-image.png

What I'm trying to introduce, is a way to verify that I just didn't bump the knob on the washing machine when transferring loads from the washer to the dryer, which turns on the display and brings the power above the Standby threshold.

The power goes up to 3.7W for about 4 minutes if the selector knob is bumped/turned.

What would the best way to do this be? I have most of my MSR code set up for a couple of years now, and my coding logic is struggling a bit.

I think I need a power threshold to be substained for a minimum time period (say 2 or 3 minutes, above 10W), before the other triggers can act. What would the best way to do that be?

Running: latest-25082-3c348de6
Fedora 41 Server
HAAS:
Core
2025.3.4
Supervisor
2025.03.4
Operating System
15.1
Frontend
20250306.0

Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT

Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.

Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Deleting widgets
tunnusT

Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266

Multi-System Reactor
MQTT configuration question
tunnusT

I have the following yaml configuration in local_mqtt_devices file

x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }'

While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?

Multi-System Reactor
System Configuration Check - time is offset
F

Hi!

I get this message when I'm on the status tab:

System Configuration Check
The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds.

I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6.
HA versions are:
Core 2025.3.4
Supervisor 2025.03.4
Operating System 15.1

I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version.
Do anyone know what I can try?
Thanks in advance!
Let's Be Careful Out There (Hill Street reference...) 🙂
/Fanan

Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT

I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB.

While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed.

So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response.

While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits

Thanks!

Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N

Hi ,
I'm on
-Reactor (Multi-hub) latest-25067-62e21a2d
-Docker on Synology NAS
-ZWaveJSUI 9.31.0.6c80945

Problem with ZwaveJSUI:
When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white.
I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui.

I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb".
After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color.

This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite.

x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33}

The "cold white" and "warm white" settings interfer with the rgb color settings.

Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white
are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white.

So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have

x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor

In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set.

x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33

Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this?

x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33}

Thanks in advance.

Multi-System Reactor
Problem with simultaneous notifications.
T

Good day all,
I have a reaction set up, that I use for both troubleshooting and changing home modes when one of my family members either arrive or are leaving. I use the companion app for HAAS on our iPhones, and HAAS reports if the person associated with the iPhone enters or leaves the geofenced area around my home. I'm sure most MSR and HAAS users are familiar with this.

I use this rule set mainly as a condition for other rules, however, as part of troubleshooting, a notification is sent through HAAS to the companion app when the rule becomes true. The problem is that I'm getting notifications now for both arriving and departing simultaneously.

96b3f7db-ba09-499e-a78c-86903b603857-image.png

36903cdd-a87f-473b-82ef-af9ef96d3c44-image.png It used to work fine as intended. I'm not sure exactly when it changed, but now I'm getting two notifications when either of these conditions change.

Any idea what could be happening?

Edit:
Running: latest-25082-3c348de6, bare-metal Linux
ZWaveJSControllerr [0.1.25082]

Multi-System Reactor
Problem after upgrading to 25067
R

MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem?
I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.

Multi-System Reactor
Global expressions not always evaluated
tunnusT

Similarly as for local expressions, global expressions evaluate and update fine when getEntity(...) structure is used. However, at least when certain functions are in use, expressions do not update.

Consider the following test case:

Screenshot 2025-03-13 at 16.29.42.png

Even though auto-evaluation is active, value does not change (it changes only if that expression is manually run). MSR restarts do not help.

Screenshot 2025-03-13 at 16.31.43.png

Note: Tested using build 25067 on Docker. I have also a PR open (but couldn't now get details or PR number as my Mantis account was somehow expired?).

Multi-System Reactor
[Solved] Local expression evaluation
V

Trying to understand what cause a local expresssion to be evaluated. I have read the manual but I am still not clear about it. Using the test rule below, I can see in the log that the rule is being automatically evaluated every time the temperature entity is changing. That is great...

What I am trying to understand is why the expression is not evaluated based on time as well since the "case" statement has time dependencies.

Any help would be appreciated

I have the following test rule:

eba6a3ea-ff61-4610-88c9-9b9864f11ff8-Screenshot 2025-01-21 095244.png

2d9c1ff5-7b73-4005-b324-9029c2709db9-Screenshot 2025-01-21 095302.png

Here is the expressioncode:

vFrom1 = "09:25:00", vFrom2 = "09:30:00", vFrom3 = "09:41:00", vTo = "10:55:00", # Get current time (format HH:MM:SS) vToDay = strftime("%H:%M:%S"), #Get current house temperature CurrentHouseTemp = getEntity( "hass>Thermostat2 " ).attributes.temperature_sensor.value, case when CurrentHouseTemp <= 19 and vToDay >= vFrom1 && vToDay <= vTo: "true1" # From1 when CurrentHouseTemp <= 20 and vToDay >= vFrom2 && vToDay <= vTo: "true2" # From2 when CurrentHouseTemp < 26  and vToDay >= vFrom3 && vToDay <= vTo: "true3" # From3 else "false" end
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S

I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved.

The Runtime Error is different in the two browsers
Safari v18.3

@http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.

Google Chrome 133.0.6943.142

TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.

Steps to reproduce:
Click the pencil to edit a global reaction with a group.
Click the Exit button.
Runtime error appears.
or
Click Create Reaction
Click Add Action
Select Group
Add Condition such as Entity Attribute.
Add an Action.
Click Save
Click Exit
Runtime error appears.

I don’t know how long the error has been there as I haven’t edited the global reaction in a long time.

Reactor (Multi-hub) latest-25060-f32eaa46
Docker
Mac OS: 15.3.1
Thanks

Multi-System Reactor
Cannot delete Global Expressions
SnowmanS

I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons.

I have not created a global expression for some times and just noticed this while doing some clean-up.

I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success.

Here's what the log shows.

[latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" }

Reactor latest-25067-62e21a2d
Docker on Synology NAS

Multi-System Reactor
Advice on Storing and Backing Up Bind Mounts - Docker
PablaP

Hello all, after seeing Catman's posts about their disaster recovery and move to Docker I took that as a sign to migrate everything (aside from HA) to Docker. After a small learning curve I had Docker+Portainer up and running in a few days.

Instead of using named Volumes I opted to use Bind Mounts so I can easily edit conf files and any other file needed. I do understand the nuances that come with bind mounts, such as migration to a different host may require changing file structures, the possibility of someone editing the bind mount files and permissions but to me those aren't too big of a deal.

My question is what is the best way to keep a back up of these bind mounts? I currently have them stored in the /etc directory in another directory named on a per container basis. I was thinking to move it all to a /home/user/docker/ directory so that I can use a simple cp command to my mounted SMB share to backup all the container data files. Anyone else do it differently?

Side note: I finally got to flex the benefits of Docker with updating Reactor.. it was dead simple. I had no idea what I was missing out on lol!

Software
Local notification methods?
CatmanV2C

Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method.

This was prompted by yesterday's fun and games with my ISP.

I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone)

I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions?

TIA

C

Multi-System Reactor
About
Posts
37
Topics
6
Groups
0
Followers
0
Following
0

Posts

Recent Best Controversial

  • Migrating from Vera Plus to Home Assistant (or other?)
    S sammy2

    Don't know where to post this really so I'll post it here.

    I am running HAos in a Virtual Machine using Oracle Virtual Box Manager.

    Occasionally, Virtual Box or HA hangs up whereupon I have to manually restart from the Windows on the NUC. I'd like to set it up to have a watchdog to Close out the HA, and then restart it when this happens automatically.

    I'd also like to keep all my Z-Wave devices connected. One of my locks will become non-responsive and show up as a dead node even though I've put two powered devices between it and the Controller. A lot of times a route rebuild does not fix it and neither will a device interview. Is there a script to have this happen on


  • Migrating from Vera Plus to Home Assistant (or other?)
    S sammy2

    Get the 800 Long Range from Zooz. It's backwards compatible.

    What hardware are you going to use to run HAOS?


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    @therealdb said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    @sammy2 yep, see for an explanation:

    DrZWave  /  Jul 13, 2021

    Z-Wave Mesh Priority Routes Explained

    Z-Wave Mesh Priority Routes Explained

    Brief explanation of how to use Application Priority Routes in the Z-Wave Mesh to optimize delivery

    It's under network graph (left menu). You need to set return routes. I have a couple of nodes that went from 10 sec to instantly, because of an horrible set of dynamic routes calculated automatically.

    That sounds like a work day and a potential to bork my system! I think physically re-routing is probably more practical.

    My locks are all now set up and working. I had to move my NUC / Controller to a high location more central in my house and put in a wired repeater to help route around a massive masonry fireplace that goes from the floor to above the roof and is about 2 or more feet thick and the full width of the wall separating the Family Room from the Laundry Room to get the lock between the laundry room and garage to show up on the network.

    Very pleased thus far with Keymaster and now I need to set up notifications so I know when certain people are coming through the locks and into my house.


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    @therealdb said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    @sammy2 said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    I need to put in more powered devices to get better hops.

    Or, try priority routes. In my cases, it helped a lot with a powered devices refusing to working correctly, but that I know is near others that are able to be used as repeaters.

    Where do you do this? Is it in Z-Wave JS UI? I haven't gone through the steps to set that up yet as it looks to take a little time from what I've read.


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    Just reporting back that with help of firstof9 on GitHub and the HA forums I got this sorted except for one lock which is probably out of range of my Z-Wave Controller. I need to put in more powered devices to get better hops.


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    @Pabla said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    image.png

    heres an example of what the service call should look like. I prefer to call services on the entity and not device. Have you also recently renamed the lock? Go to the lock in question and click it and take a look at the entity id, not the name.

    @sammy2 said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    That worked..

    image.png

    I think I need to actually install the lock on the door and see if the codes stick after setting the handing up.

    So I installed the lock and the codes sent from HA/Keymaster do work but I'm having issues with the Dashboard in that the Lock Badge at the top is not there like it is in the Front Door Dashboard:

    e6116fe0-8053-4361-93d8-ebf1a810f3e6-image.png

    59731b54-7a9f-4da2-832d-07347c555fd2-image.png

    I tried to install it manually but it isn't working. I'd like to have feedback in the Dashboard of the lock status. It does show in the Home Dashboard but doesn't work and neither does the one for the Front Door:

    46cf8b4a-56d6-499f-9eae-63ec99c5220a-image.png

    489a4dcd-2e91-40ea-88cd-401674460d7d-image.png


  • Security with Smart Door Locks
    S sammy2

    Working on it right now with keypad smart locks. Specifically Kwikset Connect 620 Z-Wave Locks and Home Assistant. I got the first one set up and am working on the second. I don't know if there are any hub based (Z-Wave or otherwise) that use biometric technology as of yet.

    That said, I had Schlage Z-Wave Locks (https://www.amazon.com/dp/B07KQY3MWL/ref=twister_B0B5MRN6V5?_encoding=UTF8&th=1)at my previous home integrated into Vera Plus. I had them set up to turn on the lights in the family room and entry way when activated and they would also notify me via email when someone used their key code to enter the house.

    I took them with me when I sold that home but in the new home aged bronze isn't going to work so I decided to go with polished brass to match the era and style of the house. I have three of these Z-Wave Locks going up for sale right now if interested. Let me know and I'll cut you a deal.


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    That worked..

    image.png

    I think I need to actually install the lock on the door and see if the codes stick after setting the handing up.


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    @Pabla said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    Home Assistant

    Performing actions

    Performing actions

    Instructions on how to perform actions in Home Assistant.

    Service call were renamed to actions but its the same thing

    couldn't get anything returned here (Not sure what I'm doing wrong):

    a5204316-e64a-4711-9a57-41f0da34aecd-image.png

    16a298da-fc24-4105-ba4a-f0b017f24dfc-image.png

    Although the lock shows up in the separate "Lock" Dashboard:

    Screenshot 2024-08-28 084902.png

    I'm seeing this in the main dashboard:

    f18f33a2-5896-4c69-bcd2-630205f1c79b-image.png

    And have these Repair Notifications:

    ff781884-0c24-40be-8b3c-c5523e6fa269-image.png


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    @Pabla said in Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working:

    Are you able to set the code via the zwave_js.set_lock_usercode service call?

    Break it down for me as in HomeAssistant / Linux CLI for Dummies!


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    Looks good to me!

    image.png


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    @Pabla

    I'm pretty sure I included it securely but where can I check?


  • Home Assistant Door Locks via Keymaster - Adding Second Lock Not Working
    S sammy2

    I have set up HA in a VM Box Virtual Machine and am progressing along.

    I got new Kwikset Connect 620 door locks and got one connected to HA via Z-Wave JS and automated via Keymaster which is quite convoluted but I got it done.

    I went to install the second lock and got it connected to HA via Z-Wave JS but am not being successful getting it to work properly in Keymaster.

    Screenshot 2024-08-28 084902.png

    Screenshot above is the second lock for the laundry room. It shows it is set up but the codes don't seem to be working.

    I have not installed the lock yet and have not set the handing either. Maybe this is the issue but IDK.

    Anyone have experience setting up locks in HA using Keymaster that can help would be great!


  • HTTPS
    S sammy2

    Sorry. Wrong thread. I mean to ask how to set up a secure server rather than phoning home over http. I already have a domain I use for my Emby Server via NameCheap (hopto.org) and Cloudflare. I think I just need to use another domain name but how to tell HomeAssistant to use the ssl / https domain?


  • Migrating from Vera Plus to Home Assistant (or other?)
    S sammy2

    NM. Found the add in on the git via a link from here.


  • HTTPS
    S sammy2

    How to add MSR to Home Assistant?


  • Migrating from Vera Plus to Home Assistant (or other?)
    S sammy2
    39 USD

    FREE HS4 Software with SmartStick G8 Controller Purchase!

    FREE HS4 Software with SmartStick G8 Controller Purchase!

    HS4 is an advanced smart home automation software that's designed to work a wide range of smart home products and technologies. Use to remotely and automatically control smart switches, thermostats, door locks, security systems, audio-video equipment, irrigation systems, garage doors, sensors,...

    Might do this for the Series 800 dongle. Thoughts?


  • BlueIris
    S sammy2

    Probably a long shot but has anyone cracked the shell on integrating BlueIris into Home Assistant?

    (Not sure if this is in the right sub forum)


  • MyQ
    S sammy2

    Probably a long shot but has anyone cracked the shell on integrating MyQ into Home Assistant?

    (Not sure if this is in the right sub forum)


  • Pentair IntelliCenter (aka Pentair Home)
    S sammy2

    Probably a long shot but has anyone cracked the shell on integrating IntelliCenter into Home Assistant?

    (Not sure if this is in the right sub forum)

  • Login

  • Don't have an account? Register

  • Login or register to search.
  • First post
    Last post
0
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved