Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. How to? Rule for Vera "Can't Detect Device" errors and reset
[Reactor] Variables not updating correctly in latest-25201-2aa18550
therealdbT
Topic thumbnail image
Multi-System Reactor
Handling Dead Entities and Renamed Entities
PablaP
Hello all.. been a minute! I recently rebuilt my Z wave network and migrated to a new z wave stick. In order to prevent any downtime I kept my original z wave network up and ran a docker version of Z Wave JS UI with my new controller. This way I could add device by device without having any devices down. I finally moved all the devices over to my new stick today. The final step was to migrate everything from my Docker instance of Z Wave JS UI to the HA add-on of Z Wave JS UI. However during this migration some of the names didn't populate correctly which I later managed to import back into Z Wave JS UI. The issue was in Reactor it is stuck on the default names and the entities are not updating. I removed the controller from Reactor, restarted, hard refreshed, and added the controller back however the new entity names have not updated. Also it seems like the old entities from my previous instance of Z Wave JS UI are lingering and not being marked as dead (I believe a certain amount of time needs to lapse before they're marked as dead in Reactor). My goal is to basically purge all the entities for the 'ZWaveJS' controller in Reactor so it can pull all the updated entity names and only the entities that exist in Z Wave JS UI. I cannot find a quick way to do this, I know entities can be deleted one by one, but with over 100 entities this would take long I am guessing that if I added the controller with a new name in in the Reactor config it would pull the updated entities and names but I think that would break my rules since the entity IDs would change (I made sure to name all the entities the exact same as they were previously to prevent this issue).
Multi-System Reactor
Strange behavior for MQTT templates using payload and attributes
therealdbT
Topic thumbnail image
Multi-System Reactor
[MSR] reactor-mqtt-contrib package for additional MQTT templates
therealdbT
I'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only). Anyway, here's my reactor-mqtt-contrib package: https://github.com/dbochicchio/reactor-mqtt-contrib Simply download yaml files (everything or just the ones you need) and you're good to go. I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them. The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression. Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests
Multi-System Reactor
HA 2025.9.4 Supported Yet?
CatmanV2C
Tangentially did I miss 2025.9.4 getting blessed in MSR? I've been holding off Cheers C
Multi-System Reactor
The reaction stopped working (Google Nest max playing a video)
F
Topic thumbnail image
Multi-System Reactor
Rule Set UI bug - RESOLVED
3
Topic thumbnail image
Multi-System Reactor
[Reactor] Copy&Paste of Rules
therealdbT
I don't know if I'm the only one, but managing more than one Reactor installs, the need to have some sort of copy&paste for rules has grown on me. While I understand the technical challenges, I'm wondering if a "god mode" where I could copy the raw JSON rule and paste it into another rule could be an advanced, flag only feature that could benefit power users. I know I can copy the JSON file and proceed, but I must stop Reactor and when doing maintenance, it's more clicks to do. Just an idea
Multi-System Reactor
[Reactor] Help with screne controller cycling logic
therealdbT
I’ve added a couple of Shelly Wave i4 as scene controllers and I’m planning to add more, since I can just use standard buttons instead of battery-powered scene controllers, which also looks better aesthetically. That said, I’m struggling to figure out how to write a simple rule that cycles between states every time I press a button. Example: Light 1 ON → OFF, then Light 2 ON → OFF. The part I can’t get right is handling the case where Light 1 or Light 2 might already be ON independently of the rule. Maybe it’s just too much sun and relaxation clouding my brain, but any hint would be appreciated.
Multi-System Reactor
Stop the MSR by an external switch on Hubitat.
wmarcolinW
Use case: When performing home maintenance, such as air conditioning, I want all rules involving air conditioning to be disabled. To do this, to day, I have a virtual switch that I placed within all rules involving air conditioning, meaning that if I turn it off, none of them work. Then another situation: the water pump system and garden irrigation, another switch. In short, I had to create several virtual switches in Hubitat to disable rules in MSR. Unfortunately, however, I was unable to cover all scenarios, so I wondered if it would be possible for MSR to support a virtual MSR switch, which, when configured in the reactor settings, would function as a general on/off switch for MSR. If it is configured and turned off, the entire rules and actions in MSR stops working, except for the status change reading process, specifically for this switch, which, when turned on, would restart the MSR. Would it be possible to do something like this? Any recommendations from the experts?
Multi-System Reactor
Expose MSR entities
CatmanV2C
Probably a really dumb question. Currently I am using the owntracks_sensor for tracking phones being in region in MSR and it works great. Digging around with Home Assistant and toying with some dashboards, is there any way of exposing that sensor to HA trivially? I could set MSR to trip a virtual switch in OpenLuup which can then be exposed to HA (with all my other Vera devices) but that feels a bit in-elegant if I can do it directly. Any thoughts? Apologies if the ask is not clear/ TIA C
Multi-System Reactor
Comment in Globa Expressions
Tom_DT
I have several Global Expressions that are set by a rule so the definition area is blank. I'd like to add a comment in this area that explains what is setting the value. Commenting in this area breaks the remote setting. Any way to document what is setting the GE?
Multi-System Reactor
Unofficial thread for compatibility
tunnusT
As there are statements about compatibility for home assistant versions in MSR new version announcements (e.g. "HassController: Bless Hass to 2025.7.3"), I thought it would be good idea to track other controllers as well. As an example, I can confirm that build "latest-25208-c53e8513" works with Hubitat Elevation C-8 platform version 2.4.2.134 using Maker API. Updates: (the latest versions first in the list) OK: build "latest-25264-2fbe9217" with Hubitat C-8 platform v. 2.4.3.123
Multi-System Reactor
Gradually turn on lights.
Tom_DT
I have several lights that I would like to turn on very gradually over 15 or 20 seconds. from 0 to .25 in .01 increments. I have tried a few things that came nowhere near working, so here I am.
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can't customize home page
G
I foolishly let my system wipe all cookies this morning and with it my settings for my MSR home page. Once logged back in I can no longer remove errant panes nor is the + available to add new ones. Brave Browser v1.80.122 (Jul 16, 2025) What have I done?! Will check other browsers on my M1. UPDATE: Safari exhibits same behaviour. I've tried both sans last-four public key entry and with - no change.
Multi-System Reactor
Error After Upgrade
T
Topic thumbnail image
Multi-System Reactor
Reset attribute value of entity in event handler
R
Topic thumbnail image
Multi-System Reactor
Need help figuring out how to delay a reset on reaction
T
Topic thumbnail image
Multi-System Reactor
Way to search for rules (rule state) in other rules
T
@toggledbits, not sure if this is a feature request or I'm using the search tool wrong. You have a "Search for rule" in the Rules Set tab in MSR. It works nicely to find a rule and bring up said rule, but can it/could it be used for as a "where used?" global search? For instance, I have a fairly large set of rules, divided up into 10 different rulesets. There's easily a hundred individual rules, and many of the rules have Rule State triggers, which of course refer to other rules. Amongst my troubleshooting today, I came across what may have been a duplicate or troubleshooting attempt, but I can't tell if it's actually used as a Rule State in another rule without opening each rule that I suspect it may be a part of. Thanks.
Multi-System Reactor

How to? Rule for Vera "Can't Detect Device" errors and reset

Scheduled Pinned Locked Moved Multi-System Reactor
21 Posts 5 Posters 3.7k Views 5 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • tunnusT tunnus

    noticed also that using CommFailure != "0" leads to false positives as not all my z-wave devices have CommFailure variable (but should be safe to add?)

    toggledbitsT Offline
    toggledbitsT Offline
    toggledbits
    wrote on last edited by
    #10

    @tunnus said in How to? Rule for Vera "Can't Detect Device" errors and reset:

    noticed also that using CommFailure != "0" leads to false positives as not all my z-wave devices have CommFailure variable

    I've amended my version of the expression to ignore devices that don't have CommFailure at all and still honor all possible non-zero values when present.

    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

    B 1 Reply Last reply
    1
    • cw-kidC cw-kid

      @tunnus

      So what are you then doing in your rules actions ? To reset the devices? Or are you just sending yourself notifications about the problem devices?

      tunnusT Offline
      tunnusT Offline
      tunnus
      wrote on last edited by
      #11

      @cw-kid as you’ve already realized, there’s really not much that can be done (programatically). I use this for notification purposes only

      Using MSR on Docker (Synology NAS), having InfluxDB, Grafana & Home Assistant, Hubitat C-8, Zigbee2MQTT

      1 Reply Last reply
      0
      • toggledbitsT toggledbits

        @tunnus said in How to? Rule for Vera "Can't Detect Device" errors and reset:

        noticed also that using CommFailure != "0" leads to false positives as not all my z-wave devices have CommFailure variable

        I've amended my version of the expression to ignore devices that don't have CommFailure at all and still honor all possible non-zero values when present.

        B Offline
        B Offline
        Buxton
        wrote on last edited by
        #12

        @toggledbits Is it the case that CommFailure is only an attribute of the HaDevice1 type. Per the below, I pre-filtered on "x_vera_svc_micasaverde_com_HaDevice1". I had some interesting results from the expression, though I'm still trying to get my head around expression syntax, so the below may be wrong:

        join( 
          each id in matchEntities( { controller: 'vera', capability: 'x_vera_svc_micasaverde_com_HaDevice1' } ): do
            e=getEntity( id ), 
            e.attributes.x_vera_svc_micasaverde_com_HaDevice1.CommFailure !=0 ? e.name : null
          done, ", " )
        

        Three of my zwave devices did not have a CommFailure attribute and I suspect, they were incorrectly migrated to my UI7 veraplus from a ui5 veralite. A reconfigure command established the CommFailure attribute for all three.

        There is one plugin on my vera (it's the only plugin on the vera) that does not have the CommFailure attribute. Does the attribute get added automatically when one installs a plugin? I'm asking in the sense that a re-install might correct the problem but I don't want to mess with anything that isn't obviously broken.

        wmarcolinW 1 Reply Last reply
        0
        • toggledbitsT Offline
          toggledbitsT Offline
          toggledbits
          wrote on last edited by
          #13

          The attributes is strictly tied to its existence on the Vera device. Use the guard code I added to my earlier getEntity() to prevent its absence from breaking the test.

          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

          B tunnusT 2 Replies Last reply
          0
          • B Buxton

            @toggledbits Is it the case that CommFailure is only an attribute of the HaDevice1 type. Per the below, I pre-filtered on "x_vera_svc_micasaverde_com_HaDevice1". I had some interesting results from the expression, though I'm still trying to get my head around expression syntax, so the below may be wrong:

            join( 
              each id in matchEntities( { controller: 'vera', capability: 'x_vera_svc_micasaverde_com_HaDevice1' } ): do
                e=getEntity( id ), 
                e.attributes.x_vera_svc_micasaverde_com_HaDevice1.CommFailure !=0 ? e.name : null
              done, ", " )
            

            Three of my zwave devices did not have a CommFailure attribute and I suspect, they were incorrectly migrated to my UI7 veraplus from a ui5 veralite. A reconfigure command established the CommFailure attribute for all three.

            There is one plugin on my vera (it's the only plugin on the vera) that does not have the CommFailure attribute. Does the attribute get added automatically when one installs a plugin? I'm asking in the sense that a re-install might correct the problem but I don't want to mess with anything that isn't obviously broken.

            wmarcolinW Offline
            wmarcolinW Offline
            wmarcolin
            wrote on last edited by
            #14

            @buxton as @toggledbits mentioned, in another conversation (https://smarthome.community/topic/739/logic-loop-throttling/11) we discussed a similar situation, I recommend reading it.

            And if I can do a suggestion, do not use CommFailure for this evaluation. I did several simulations in the exercise we mentioned, and this attribute fails more than x_vera_device.failed, this one responds faster (true / false).

            Below is the screen of the test I am using, with the Global variable.

            3ce48175-8a58-4aa2-9ae6-55f1f94ac979-image.png

            B 1 Reply Last reply
            0
            • wmarcolinW wmarcolin

              @buxton as @toggledbits mentioned, in another conversation (https://smarthome.community/topic/739/logic-loop-throttling/11) we discussed a similar situation, I recommend reading it.

              And if I can do a suggestion, do not use CommFailure for this evaluation. I did several simulations in the exercise we mentioned, and this attribute fails more than x_vera_device.failed, this one responds faster (true / false).

              Below is the screen of the test I am using, with the Global variable.

              3ce48175-8a58-4aa2-9ae6-55f1f94ac979-image.png

              B Offline
              B Offline
              Buxton
              wrote on last edited by
              #15

              @wmarcolin Yes, thanks. I have the data point "x_vera_device.failed" covered with the following expression:

              join( 
                each id in matchEntities( { controller: 'vera', capability: 'x_vera_device' } ): do
                  e=getEntity( id ), 
                  e.attributes.x_vera_device.failed ? e.name  :  null
                done, ", " )
              

              I was using CommFailure to detect devices that have not been configured properly, and sure enough, I found three on my network.

              1 Reply Last reply
              0
              • toggledbitsT toggledbits

                The attributes is strictly tied to its existence on the Vera device. Use the guard code I added to my earlier getEntity() to prevent its absence from breaking the test.

                B Offline
                B Offline
                Buxton
                wrote on last edited by
                #16

                @toggledbits said in How to? Rule for Vera "Can't Detect Device" errors and reset:

                The attributes is strictly tied to its existence on the Vera device

                Yes, I was asking more in general terms about what happens when a plugin gets initialized. And whether CommFailure is a specific attribute of Vera's HaDevice1 type.

                1 Reply Last reply
                0
                • toggledbitsT toggledbits

                  The attributes is strictly tied to its existence on the Vera device. Use the guard code I added to my earlier getEntity() to prevent its absence from breaking the test.

                  tunnusT Offline
                  tunnusT Offline
                  tunnus
                  wrote on last edited by tunnus
                  #17

                  @toggledbits These devices that for some reason do not have CommFailure variable set, do you think it is safe to just manually add it? Don't want to do anything too "extensive", like exclusion/inclusion process

                  Screenshot 2021-10-20 at 11.48.03.png

                  Using MSR on Docker (Synology NAS), having InfluxDB, Grafana & Home Assistant, Hubitat C-8, Zigbee2MQTT

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by
                    #18

                    Guarding for it in your expressions is the "right" way (example shown in linked post).

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    tunnusT 1 Reply Last reply
                    0
                    • toggledbitsT toggledbits

                      Guarding for it in your expressions is the "right" way (example shown in linked post).

                      tunnusT Offline
                      tunnusT Offline
                      tunnus
                      wrote on last edited by
                      #19

                      @toggledbits yep, I'm using that also, but wondering if I could add those missing variables

                      Using MSR on Docker (Synology NAS), having InfluxDB, Grafana & Home Assistant, Hubitat C-8, Zigbee2MQTT

                      1 Reply Last reply
                      0
                      • toggledbitsT Offline
                        toggledbitsT Offline
                        toggledbits
                        wrote on last edited by toggledbits
                        #20

                        You can, but I wouldn't. But I've spent 40 years as a software engineer, and have learned many times over that you don't bend the input to conform to your algorithm, you get the algorithm right, so I'm (probably very predictably) stubborn about that kind of thing. Proper guarding for null (missing data) ensures that the result works always works (e.g. after including new devices or replacing existing, or broken devices/driver/plugin implementations, etc.), and is thus applicable to all users (so the code they see posted here actually works for them to the greatest degree possible without assembling other information or steps that may not be obvious).

                        If you're guarding properly, there's no need for the extra work and ongoing maintenance.

                        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                        1 Reply Last reply
                        0
                        • toggledbitsT Offline
                          toggledbitsT Offline
                          toggledbits
                          wrote on last edited by
                          #21

                          It was noted in another thread covering a specific case of this topic that it's possible, on some hubs (ahem), for a device to flap its *failed" state quickly, and perhaps is even likely due to temporary network/mesh/device issues, or a simple choice that during restart of the hub devices are marked down until known up. All of this may cause quick, although likely uninteresting, transitions between failed and not-failed.

                          It may therefore be advisable to use the "sustained for" option on any rule that reacts to a change in identified failed devices, to dampen the response to such potentially spurious state changes.

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          1 Reply Last reply
                          1
                          • toggledbitsT toggledbits locked this topic on
                          • cw-kidC cw-kid referenced this topic on
                          • cw-kidC cw-kid referenced this topic on
                          Reply
                          • Reply as topic
                          Log in to reply
                          • Oldest to Newest
                          • Newest to Oldest
                          • Most Votes


                          Recent Topics

                          • [Reactor] Variables not updating correctly in latest-25201-2aa18550
                            toggledbitsT
                            toggledbits
                            0
                            76
                            5.5k

                          • Do you Matter?
                            CatmanV2C
                            CatmanV2
                            0
                            2
                            64

                          • Caution: zwave-js-ui docker 11.4.0 is broken
                            toggledbitsT
                            toggledbits
                            0
                            2
                            69

                          • Shelly Wall Display XL
                            therealdbT
                            therealdb
                            2
                            6
                            160

                          • Handling Dead Entities and Renamed Entities
                            PablaP
                            Pabla
                            0
                            5
                            128

                          • Strange behavior for MQTT templates using payload and attributes
                            toggledbitsT
                            toggledbits
                            0
                            6
                            172

                          • [MSR] reactor-mqtt-contrib package for additional MQTT templates
                            therealdbT
                            therealdb
                            1
                            46
                            8.4k

                          • HA 2025.9.4 Supported Yet?
                            toggledbitsT
                            toggledbits
                            0
                            2
                            109

                          • The reaction stopped working (Google Nest max playing a video)
                            toggledbitsT
                            toggledbits
                            0
                            7
                            390

                          • Rule Set UI bug - RESOLVED
                            toggledbitsT
                            toggledbits
                            1
                            2
                            256

                          • [Reactor] Copy&Paste of Rules
                            therealdbT
                            therealdb
                            0
                            1
                            309

                          • [Reactor] Help with screne controller cycling logic
                            toggledbitsT
                            toggledbits
                            0
                            5
                            423
                          Powered by NodeBB | Contributors
                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                          • Login

                          • Don't have an account? Register

                          • Login or register to search.
                          • First post
                            Last post
                          0
                          • Categories
                          • Recent
                          • Tags
                          • Popular
                          • Unsolved