Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. Need assistance: How do I calculate time based upon current time and an ETA
Set Reaction > Script Action
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Errors after updating to MQTTController build 25139
tunnusT
I'm running MSR build 25139 on Docker, using MQTT controller 24293, and everything working as expected. But if I try to upgrade to MQTTController build 25139, I'm getting the following errors on MSR UI: An Entity Attribute condition in "Lay-Z-Spa auto heating off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.god Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa auto heating off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute temperature_sensor.green Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa filter pump auto off" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute temperature_sensor.red Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa filter pump auto run" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.pump Last 11:20:37 An Entity Attribute condition in "Lay-Z-Spa watchdog" (Terrace) failed because the referenced entity "Lay-Z-Spa States" (mqtt>layzspa_states) does not have attribute value_sensor.status Last 11:20:37 My MQTT configuration (local_mqtt_devices.yaml) for the related entity is: layzspa_message: type: ValueSensor capabilities: ["temperature_sensor", "value_sensor", "power_sensor"] primary_attribute: power_sensor.value events: "layzspa/message": "power_sensor.value": json_payload: true if_expr: '! isnull( payload?.PWR )' expr: "float(payload.PWR)" "value_sensor.air": json_payload: true if_expr: '! isnull( payload?.AIR )' expr: "float(payload.AIR)" "value_sensor.pump": json_payload: true if_expr: '! isnull( payload?.FLT )' expr: "float(payload.FLT)" "value_sensor.god": json_payload: true if_expr: '! isnull( payload?.GOD )' expr: "float(payload.GOD)" "value_sensor.lock": json_payload: true if_expr: '! isnull( payload?.LCK )' expr: "float(payload.LCK)" "value_sensor.unit": json_payload: true if_expr: '! isnull( payload?.UNT )' expr: "float(payload.UNT)" "value_sensor.error": json_payload: true if_expr: '! isnull( payload?.ERR )' expr: "float(payload.ERR)" "temperature_sensor.green": json_payload: true if_expr: '! isnull( payload?.GRN )' expr: "float(payload.GRN)" "temperature_sensor.red": json_payload: true if_expr: '! isnull( payload?.RED )' expr: "float(payload.RED)" "temperature_sensor.target": json_payload: true if_expr: '! isnull( payload?.TGT )' expr: "float(payload.TGT)" "temperature_sensor.value": json_payload: true if_expr: '! isnull( payload?.TMP )' expr: "float(payload.TMP)" "temperature_sensor.virtual": json_payload: true if_expr: '! isnull( payload?.VTM )' expr: "round(float(payload.VTM), 1)" "temperature_sensor.ambient": json_payload: true if_expr: '! isnull( payload?.AMB )' expr: "float(payload.AMB)" "layzspa/Status": "value_sensor.status": if_expr: '! isnull( payload )' expr: "payload" "layzspa/button": "value_sensor.button": if_expr: '! isnull( payload )' expr: "payload" and in reactor.yaml I have: "layzspa_states": name: "Lay-Z-Spa States" friendly_name: 'Lay-Z-Spa States' include: layzspa_message I realize my MQTT configuration might be a bit unorthodox, but could there still be something unintentional in the latest MQTTController build? If needed, I can provide detailed logs.
Multi-System Reactor
🎉 My very first MSR controller: OpenSprinkler
therealdbT
Since today is my birthday - and I still pretend to be unconventional - I'm giving away a present to this wonderful community and I'm releasing my first OpenSprinkler controller for MSR. It was real fun to code it - and while it's still WIP, it seems to work OK for me. It's polling-based at the moment, but I'll add support for updates via MQTT very soon (it's already partially coded). Get it at (install is similar to MQTTController and such): https://github.com/dbochicchio/reactor-opensprinkler Feel free to try it. It's beta software, but it's stable. I'll update it weekly until all the tasks from my todo list are empty. Since I've learnt a lot from this controller, I'll explore new controllers soon.
Multi-System Reactor
Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor

Need assistance: How do I calculate time based upon current time and an ETA

Scheduled Pinned Locked Moved Multi-System Reactor
9 Posts 2 Posters 550 Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • T Offline
    T Offline
    tamorgen
    wrote on last edited by tamorgen
    #1

    Good morning,
    I apologize if this subject has been covered. I did try the search, but I'm not coming up with any topics on my issue.

    I'm running userauth-24137-57b41335, bare metal installation on Fedora 39 Server.

    I have a rule set up to turn the Eco mode off on my Nest Thermostat when the thermostat is set to Away (Rule State: Away Mode), the user (Driver) presence in my car changes to true, and the destination is set to home.

    93804f7c-62d6-42c0-ae04-ff602011a6fd-image.png

    This works fine for most days, where I'm headed home from work (commute is about 45 minutes). What I don't want it to do is set change it to Eco mode if my ETA is more than an hour.

    There is a sensor/entity for Time to Arrival when the Destination is set. What it appears to provide is the Time OF arrival/ETA, not time until arrival. If it was Time until Arrival, and it was a numeric value, I could simply test if the value is less than 60 and be done with it.

    I pulled up the history through Home Assistant for my morning commute and this appears to be what it is providing.

    c2a32739-c84f-4a05-95d9-73793ed818f5-image.png

    So what I need to do is to do a calculation of the the ETA from the sensor value and subtract the current time, and get a value in minutes that I can determine if it's less than 60.

    I believe I can do this with the local expression, but I don't see anything for the system time, or local time. Also, do the local expressions update themselves if the sensors do?

    e7f2ffa6-0ae2-4137-9238-65868d9a9f50-image.png

    toggledbitsT 1 Reply Last reply
    0
    • T tamorgen

      Good morning,
      I apologize if this subject has been covered. I did try the search, but I'm not coming up with any topics on my issue.

      I'm running userauth-24137-57b41335, bare metal installation on Fedora 39 Server.

      I have a rule set up to turn the Eco mode off on my Nest Thermostat when the thermostat is set to Away (Rule State: Away Mode), the user (Driver) presence in my car changes to true, and the destination is set to home.

      93804f7c-62d6-42c0-ae04-ff602011a6fd-image.png

      This works fine for most days, where I'm headed home from work (commute is about 45 minutes). What I don't want it to do is set change it to Eco mode if my ETA is more than an hour.

      There is a sensor/entity for Time to Arrival when the Destination is set. What it appears to provide is the Time OF arrival/ETA, not time until arrival. If it was Time until Arrival, and it was a numeric value, I could simply test if the value is less than 60 and be done with it.

      I pulled up the history through Home Assistant for my morning commute and this appears to be what it is providing.

      c2a32739-c84f-4a05-95d9-73793ed818f5-image.png

      So what I need to do is to do a calculation of the the ETA from the sensor value and subtract the current time, and get a value in minutes that I can determine if it's less than 60.

      I believe I can do this with the local expression, but I don't see anything for the system time, or local time. Also, do the local expressions update themselves if the sensors do?

      e7f2ffa6-0ae2-4137-9238-65868d9a9f50-image.png

      toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by
      #2

      @tamorgen said in Need assistance: How do I calculate time based upon current time and an ETA:

      I don't see anything for the system time, or local time.

      In the docs, Date/Time Handling Functions.

      @tamorgen said in Need assistance: How do I calculate time based upon current time and an ETA:

      do the local expressions update themselves if the sensors do?

      Absolutely.

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      T 1 Reply Last reply
      0
      • toggledbitsT toggledbits

        @tamorgen said in Need assistance: How do I calculate time based upon current time and an ETA:

        I don't see anything for the system time, or local time.

        In the docs, Date/Time Handling Functions.

        @tamorgen said in Need assistance: How do I calculate time based upon current time and an ETA:

        do the local expressions update themselves if the sensors do?

        Absolutely.

        T Offline
        T Offline
        tamorgen
        wrote on last edited by
        #3

        @toggledbits said in Need assistance: How do I calculate time based upon current time and an ETA:

        In the docs, Date/Time Handling Functions.

        Okay, I missed that. That raises more questions.

        I'm thinking it's easier to convert my ETA sensor to Unix Epic, and then do the math from there, correct? Do you have any examples on how I would go about doing this?

        I went to lunch and pulled up MSR so I could get the actual, real time output of time to a destination.

        4273beeb-2fca-462c-882c-847181074cda-image.png

        1 Reply Last reply
        0
        • T Offline
          T Offline
          tamorgen
          wrote on last edited by
          #4

          I tested using a static unix epoch time, and I pulled the time for one of my other sensor so I can work on testing the conversion.....

          Getting there.

          image.png

          1 Reply Last reply
          0
          • T Offline
            T Offline
            tamorgen
            wrote on last edited by tamorgen
            #5

            And I figured it out....

            88a1a15c-dd4b-47e9-aaff-e84412aeff8c-image.png

            1 Reply Last reply
            0
            • T Offline
              T Offline
              tamorgen
              wrote on last edited by tamorgen
              #6

              May have spoke too soon....

              0836b295-e955-487f-8faa-c77a000152d9-image.png

              Since the current value is null, it's going to throw a yellow triangle, because it can't be evaluated.

              @toggledbits Is there a way to clear that flag for a local expression that is only periodically filled?

              Correction: the value for the sensor is "unavailable", not null....

              The value for the local expression becomes "null", because of the "unavailable" value for the sensor.

              49ceee29-c914-40bc-90f4-37d2507431ab-image.png

              1 Reply Last reply
              0
              • T Offline
                T Offline
                tamorgen
                wrote on last edited by
                #7

                It also throws an error in the status pane.
                image.png

                1 Reply Last reply
                0
                • toggledbitsT Offline
                  toggledbitsT Offline
                  toggledbits
                  wrote on last edited by toggledbits
                  #8

                  Try this:

                  D=getEntity( "hass>sensor_spaceball_1_time_to_arrival" ).attributes.string_sensor?.value,
                  if "unavailable" === D
                    then null
                    else do
                      D = time( D ),
                      D = isNaN( D ) ? null : round( ( D - time() ) / 60000 )
                    done
                  endif
                  

                  The first line sets up the attribute value in a temporary local variable (i.e. available only inside the expression) called eta.

                  Line 2 checks to see if it's the string unavailable, and if so, line 3 will cause this expression to produce null as a result.

                  Otherwise, the else block beginning at line 4 starts by converting the string in eta to a time in milliseconds (line 5), and if that result isn't NaN (line 6), then the difference between that time and now in minutes is computed.

                  The test ? true-expr : false-expr form on line 6 is a ternary operator, if you haven't used it before. It's equivalent to IF test THEN true-expr ELSE false-expr ENDIF, just shorter.

                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                  T 1 Reply Last reply
                  1
                  • toggledbitsT toggledbits

                    Try this:

                    D=getEntity( "hass>sensor_spaceball_1_time_to_arrival" ).attributes.string_sensor?.value,
                    if "unavailable" === D
                      then null
                      else do
                        D = time( D ),
                        D = isNaN( D ) ? null : round( ( D - time() ) / 60000 )
                      done
                    endif
                    

                    The first line sets up the attribute value in a temporary local variable (i.e. available only inside the expression) called eta.

                    Line 2 checks to see if it's the string unavailable, and if so, line 3 will cause this expression to produce null as a result.

                    Otherwise, the else block beginning at line 4 starts by converting the string in eta to a time in milliseconds (line 5), and if that result isn't NaN (line 6), then the difference between that time and now in minutes is computed.

                    The test ? true-expr : false-expr form on line 6 is a ternary operator, if you haven't used it before. It's equivalent to IF test THEN true-expr ELSE false-expr ENDIF, just shorter.

                    T Offline
                    T Offline
                    tamorgen
                    wrote on last edited by
                    #9

                    @toggledbits,
                    Thank you Patrick. It's not throwing an alert now. Very elegant solution.

                    I'll verify that it works once I get in the car after work and marked the thread as solved.

                    1 Reply Last reply
                    0
                    • toggledbitsT toggledbits locked this topic on
                    Reply
                    • Reply as topic
                    Log in to reply
                    • Oldest to Newest
                    • Newest to Oldest
                    • Most Votes


                    Recent Topics

                    • Set Reaction > Script Action
                      therealdbT
                      therealdb
                      0
                      6
                      85

                    • Wiring Samotech SM308-S into light fitting
                      akbooerA
                      akbooer
                      0
                      2
                      44

                    • Errors after updating to MQTTController build 25139
                      toggledbitsT
                      toggledbits
                      0
                      6
                      74

                    • 🎉 My very first MSR controller: OpenSprinkler
                      therealdbT
                      therealdb
                      5
                      13
                      631

                    • Advice reqeusted to migrate MSR from Bare Metal to Container
                      T
                      tamorgen
                      0
                      5
                      95

                    • Reactor (Multi-System/Multi-Hub) Announcements
                      toggledbitsT
                      toggledbits
                      5
                      122
                      37.3k

                    • Z-Wave Future....
                      CatmanV2C
                      CatmanV2
                      0
                      5
                      178

                    • Can´t restart or upgrade/deploy MSR
                      toggledbitsT
                      toggledbits
                      0
                      4
                      135

                    • [Solved] Limit HA Entity in MSR
                      wmarcolinW
                      wmarcolin
                      0
                      7
                      264

                    • Disaster recovery and virtualisation
                      CatmanV2C
                      CatmanV2
                      0
                      5
                      702

                    • Remote access of Zwave stick from Z-wave server
                      CatmanV2C
                      CatmanV2
                      0
                      3
                      429
                    Powered by NodeBB | Contributors
                    Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                    • Login

                    • Don't have an account? Register

                    • Login or register to search.
                    • First post
                      Last post
                    0
                    • Categories
                    • Recent
                    • Tags
                    • Popular
                    • Unsolved