Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor

[Solved] Bi-weekly interval

Scheduled Pinned Locked Moved Multi-System Reactor
7 Posts 4 Posters 374 Views 4 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • tunnusT Offline
    tunnusT Offline
    tunnus
    wrote on last edited by tunnus
    #1

    Struggled with this also in RfV, and now trying to implement the same with MSR. I'm trying to setup a bi-weekly interval as illustrated below:

    Screenshot 2021-08-11 at 15.52.21.png

    Understood that interval "relative to condition" is deprecated so I used "relative to time" in my test, although it sort of failed already as that condition triggered whereas it should have triggered after 18th? So pulse is the only option for this kind of 14 day interval (fixed to a certain date)?

    Using MSR on Docker (Synology NAS), having InfluxDB, Grafana & Home Assistant, Hubitat C-8, Zigbee2MQTT

    3 1 Reply Last reply
    0
    • toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by toggledbits
      #2

      The Interval triggered immediately because it thinks it missed an interval at the time you saved it. Just set the reset delay down very low, a few seconds, and reset/clear the Rule. It will trigger for the "missed" interval, and then put itself on schedule for 14 days from your reference time/date. You can safely put the delay reset back to the longer time after that, just save, but do not reset the rule again, or you will have to start over. The long delay may also not be necessary, because rules only trigger when states change; the purpose of the delay is to defer the change from true to false, not to extend the period that the reaction or other rules have to run (it doesn't work that way and no such limit exists or is required to be accounted for, usually -- see discussion of counter-activities in docs).

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      tunnusT 1 Reply Last reply
      2
      • tunnusT tunnus

        Struggled with this also in RfV, and now trying to implement the same with MSR. I'm trying to setup a bi-weekly interval as illustrated below:

        Screenshot 2021-08-11 at 15.52.21.png

        Understood that interval "relative to condition" is deprecated so I used "relative to time" in my test, although it sort of failed already as that condition triggered whereas it should have triggered after 18th? So pulse is the only option for this kind of 14 day interval (fixed to a certain date)?

        3 Offline
        3 Offline
        3rdStng
        wrote on last edited by
        #3

        @tunnus said in Bi-weekly interval:

        interval "relative to condition" is deprecated

        What are the options/best methods to replace the relative to condition being true option.

        I have a couple 5 minute intervals that I only want to be active when a trigger is met. For example, if you leave a door open, it's hot outside, and the AC is on. I want the AC to turn off only after the door has been open for 5 minutes. If I use the Relative to time option, the door being open could be true at the 4 minute mark and then 1 minute later the interval will be met and shut off the AC after the door only being open for 1 minute.

        And now that I type this all out, one option would be to use the Interval based on time and put a Condition must be true for 5 minutes on the door being open. The catch here is that the door could opened at minute 6, not be true until minute 11. At which point I would need to wait another 4 minutes for the interval to be true.

        1 Reply Last reply
        0
        • R Offline
          R Offline
          RogerO
          wrote on last edited by
          #4
          This post is deleted!
          1 Reply Last reply
          0
          • toggledbitsT toggledbits

            The Interval triggered immediately because it thinks it missed an interval at the time you saved it. Just set the reset delay down very low, a few seconds, and reset/clear the Rule. It will trigger for the "missed" interval, and then put itself on schedule for 14 days from your reference time/date. You can safely put the delay reset back to the longer time after that, just save, but do not reset the rule again, or you will have to start over. The long delay may also not be necessary, because rules only trigger when states change; the purpose of the delay is to defer the change from true to false, not to extend the period that the reaction or other rules have to run (it doesn't work that way and no such limit exists or is required to be accounted for, usually -- see discussion of counter-activities in docs).

            tunnusT Offline
            tunnusT Offline
            tunnus
            wrote on last edited by
            #5

            @toggledbits I did as you instructed, but at least according to UI it's going to calculate these 14 days starting today and triggering on 26th (and not on 18th)?

            Screenshot 2021-08-12 at 11.31.28.png

            Using MSR on Docker (Synology NAS), having InfluxDB, Grafana & Home Assistant, Hubitat C-8, Zigbee2MQTT

            1 Reply Last reply
            0
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by toggledbits
              #6

              I'm inclined to just wait and see what happens. But remove the pulsing date/time condition, because that may interfere.

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              tunnusT 1 Reply Last reply
              1
              • toggledbitsT toggledbits

                I'm inclined to just wait and see what happens. But remove the pulsing date/time condition, because that may interfere.

                tunnusT Offline
                tunnusT Offline
                tunnus
                wrote on last edited by
                #7

                @toggledbits works now as expected

                Using MSR on Docker (Synology NAS), having InfluxDB, Grafana & Home Assistant, Hubitat C-8, Zigbee2MQTT

                1 Reply Last reply
                0
                • toggledbitsT toggledbits locked this topic on
                Reply
                • Reply as topic
                Log in to reply
                • Oldest to Newest
                • Newest to Oldest
                • Most Votes


                Recent Topics

                • Advice reqeusted to migrate MSR from Bare Metal to Container
                  T
                  tamorgen
                  0
                  5
                  61

                • Reactor (Multi-System/Multi-Hub) Announcements
                  toggledbitsT
                  toggledbits
                  5
                  122
                  35.8k

                • Z-Wave Future....
                  CatmanV2C
                  CatmanV2
                  0
                  5
                  150

                • Can´t restart or upgrade/deploy MSR
                  toggledbitsT
                  toggledbits
                  0
                  4
                  101

                • [Solved] Limit HA Entity in MSR
                  wmarcolinW
                  wmarcolin
                  0
                  7
                  215

                • Disaster recovery and virtualisation
                  CatmanV2C
                  CatmanV2
                  0
                  5
                  679

                • Remote access of Zwave stick from Z-wave server
                  CatmanV2C
                  CatmanV2
                  0
                  3
                  395

                • Organizing/ structuring rule sets and rules
                  G
                  gwp1
                  0
                  5
                  392

                • Moving MSR from a QNAP container to RP 5 - some issues
                  G
                  gwp1
                  0
                  5
                  363

                • Widget deletion does not work and landing page (status) is empy
                  G
                  gwp1
                  0
                  4
                  354

                • Need help reducing false positive notifications
                  T
                  tamorgen
                  0
                  7
                  543
                Powered by NodeBB | Contributors
                Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                • Login

                • Don't have an account? Register

                • Login or register to search.
                • First post
                  Last post
                0
                • Categories
                • Recent
                • Tags
                • Popular
                • Unsolved