P

powisquare

@powisquare
[Reactor] Bug when sending MQTT boolean payloads
therealdbT
Topic thumbnail image
Multi-System Reactor
Genuinely impressed with Zigbee and HA / Reactor
CatmanV2C
Just for the record, in case anyone is following, I'm really rather impressed. I have installed one of these: https://www.amazon.co.uk/dp/B0B6P22YJC?ref=ppx_yo2ov_dt_b_fed_asin_title&th=1 That's connected (physically) to the VM running on my Synology, with a 2m USB extension. The same host also runs Openluup, Mosquito, HA Bridge. Yesterday I installed Zigbee2mqtt. That was a bit of a PITA but mostly because of ports and permissions. Once up and running, and the correct boxes ticked, immediately visible in Home Assistant via the MQTT integration, and thence into Reactor I've only got two devices. I bought the cheapest sensor I could find, which is a door sensor. Dead easy to add to ZIgbee2mqtt and again, immediately visible in HA. https://www.amazon.co.uk/dp/B0FPQLWRW1?ref=ppx_yo2ov_dt_b_fed_asin_title The dongle is on the top floor of the house, and I wanted the sensor on the back door (just about as far apart as it's possible to get short of going into the garage) When I moved the sensor downstairs it dropped out pretty instantly (which wasn't a huge surprise) so quick bit of research found out that smart plugs will act as routers so... https://www.amazon.co.uk/dp/B0FDQDPGBB?ref=ppx_yo2ov_dt_b_fed_asin_title Took me about 30 seconds to connect. Updated the name. Instantly visible in Reactor with the new name pushed over from Zigbee2mqtt. And lo, the door sensor now has a signal of 140 and works as far as I can tell perfectly and instantly (unlike my z-wave one). A few more of those will be purchased and used to replace the Tuya wifi cloud devices and the (continually failing) Z-wave plugs (yeah, they were TKB so....) Commended to the house. Thanks for everyone that got me on the right lines. C
Zigbee
Difficulty defining repeating annual period
R
I have tried numerous ways to define a recurring annual period, for example from December 15 to January 15. No matter which method I try - after and before, between, after and/not after, Reactor reports "waiting for invalid date, invalid date. Some constructs also seem to cause Reactor to hang, timeout and restart. For example "before January 15 is evaluated as true, but reports "waiting for invalid date, invalid date". Does anyone have a tried and true method to define a recurring annual period? I think the "between" that I used successfully in the past may have broken with one of the updates.
Multi-System Reactor
Need help with sequence
T
Good evening all, For about the past week or so, I've been having problems with a specific rule in my home automation that controls when my home goes from an Away mode to Home mode. One of the conditions it checked for was my alarm panel, when it changed from Armed Away to Disarmed. There seems to have been a firmware update on the panel that added an intermittent step of "pending", and I can't say for certain it happens 100% of the time. Is there a way to write a condition that so it changes from one condition, to the next, and then another condition? As in, Home alarm changes from armed_away to pending to disarmed. Thanks.
Multi-System Reactor
Possible feature request?
CatmanV2C
No idea how easy this would be. During my migration away from Z-wave I've been replacing the Z-wave devices with Sonoff which has broken some of my automations. Any chance of a 'Test Reaction' function to call out which ones are broken because an entity no longer exists? Without actually running the reaction? Or does this exist already and I'm just not aware of how to do it? Obviously I can see entities that are no longer available, but not quite what I'm looking for. I guess it's something of an edge case so no huge issue. TIA! C
Multi-System Reactor
Copying a global reaction
tunnusT
With build 25328, if you copy a global reaction, a new reaction does not appear in the UI unless you do a refresh. I recall this used to work without needing this page refresh? Anyway, only a minor nuisance.
Multi-System Reactor
Logic Assistance: Exterior Lights on when Illuminance Below Threshold
PablaP
Topic thumbnail image
Multi-System Reactor
Time series documentation
tunnusT
Is the current manual (incl. examples) up to date with how retention value is handled in time series configuration? Referring to this post
Multi-System Reactor
Tuya Wifi to Tasmota flashing
CatmanV2C
Just popping this in here in case it's helpful to anyone else later. I've got several Tuya Wifi sockets that I'm getting rid of / replacing. Looking at which ones, if any, can be flashed to Tasmota: https://www.amazon.co.uk/dp/B09Y212TCK?ref=ppx_yo2ov_dt_b_fed_asin_title&th=1 Are NOT flashable C
Zigbee
MQTT templates for ZIgbee scene controller, or a better way?
CatmanV2C
Topic thumbnail image
Multi-System Reactor
Reset a delay
CatmanV2C
I'm sure this has been asked, and answered, but damned if I can figure it out Use case: I have a rear garden with lights. A door from the kitchen into the garden and a door from the garage. Currently if I open the kitchen door the lights come on (yay) and a 3 minute delay starts. After 3 minutes, no matter what else happens, the lights go off (Boo! But also yay!) What I would like is for the 3 minute delay until the lights go off to start from the latest door open event. That is, if I'm going from kitchen to garage, and back again, the lights stay on until there's three minutes of no activity. I've tried 'hacking' with a virtual switch, but can't seem to stop the delay. Any pointers? TIA C
Multi-System Reactor
Zigbee2mqtt installed! sytemctl not happy :(
CatmanV2C
Hello oh great ones. After a couple of hours messing with ports and permissions I have Zigbee2mqtt installed and running on my virtual pi Can connect to the front end and everything Odd one though, simply cannot get systemctl to work and the error is, well, unhelpful. The service file is this: [Unit] Description=zigbee2mqtt After=network.target [Service] Environment=NODE_ENV=production Type=notify ExecStart=/usr/local/bin/node index.js WorkingDirectory=/opt/zigbee2mqtt StandardOutput=inherit # Or use StandardOutput=null if you don't want Zigbee2MQTT messages filling syslog, for more options see systemd.exec(5) StandardError=inherit WatchdogSec=10s Restart=always RestartSec=10s User=pi [Install] WantedBy=multi-user.target Straight out of the docs with the change to point to my local node install (which we know works as it's the same as the very fine Reactor is using. Running manually pnpm start in /opt/zigbee2mqtt works fine However: catman@openluup:/etc/systemd/system$ sudo systemctl start zigbee2mqtt.service Job for zigbee2mqtt.service failed because the control process exited with error code. See "systemctl status zigbee2mqtt.service" and "journalctl -xe" for details. Which I have catman@openluup:/etc/systemd/system$ sudo systemctl status zigbee2mqtt.service ● zigbee2mqtt.service - zigbee2mqtt Loaded: loaded (/etc/systemd/system/zigbee2mqtt.service; disabled; vendor preset: enabled) Active: activating (auto-restart) (Result: exit-code) since Tue 2025-12-16 12:32:42 GMT; 4s ago Process: 3093 ExecStart=/usr/local/bin/node index.js (code=exited, status=217/USER) Main PID: 3093 (code=exited, status=217/USER) and -- A start job for unit zigbee2mqtt.service has begun execution. -- -- The job identifier is 17477. Dec 16 12:35:16 openluup systemd[3178]: zigbee2mqtt.service: Failed to determine user credentials: No such process Dec 16 12:35:16 openluup systemd[3178]: zigbee2mqtt.service: Failed at step USER spawning /usr/local/bin/node: No such process -- Subject: Process /usr/local/bin/node could not be executed -- Defined-By: systemd -- Support: https://www.debian.org/support -- -- The process /usr/local/bin/node could not be executed and failed. -- -- The error number returned by this process is ERRNO. Dec 16 12:35:16 openluup systemd[1]: zigbee2mqtt.service: Main process exited, code=exited, status=217/USER -- Subject: Unit process exited -- Defined-By: systemd -- Support: https://www.debian.org/support -- -- An ExecStart= process belonging to unit zigbee2mqtt.service has exited. -- -- The process' exit code is 'exited' and its exit status is 217. Dec 16 12:35:16 openluup systemd[1]: zigbee2mqtt.service: Failed with result 'exit-code'. -- Subject: Unit failed -- Defined-By: systemd -- Support: https://www.debian.org/support -- -- The unit zigbee2mqtt.service has entered the 'failed' state with result 'exit-code'. Dec 16 12:35:16 openluup systemd[1]: Failed to start zigbee2mqtt. -- Subject: A start job for unit zigbee2mqtt.service has failed -- Defined-By: systemd -- Support: https://www.debian.org/support -- -- A start job for unit zigbee2mqtt.service has finished with a failure. Which strikes me as very odd. Any blindingly obvious things I'm missing? TIA! C
Zigbee
Any thoughts on which is better
CatmanV2C
Obviously a quiet forum, but perhaps it's time I'm looking at rolling Zigbee into my system, in large part for the Aqara FP300 presence sensors which seem to finally provide a solution to if the wasp is actually in the box. My current set up is as follows: One Debian VM on Synology NAS running: Z-wave Server Open Luup Multi system reactor HA bridge Mosquito MQQT broker This machine has a UZB Z-wave stick connected via the USB port on the NAS Another HAOS VM on the same NAS running HAOS I've got some older Z-wave stuff that I keep around until it fails. I have some Tuya stuff integrated in HA My thought was to get either a SMLIGHT SLZB-06M or an Aqara Hub M2 Integrate them via Zigbee2MQQT (running on the Debian machine) and then expose them in HA so I can continue to automate in MSR. Thoughts on which of those devices wold be preferable long term. Both are POE capable which is good. It also appears I could add a USB dongle to the NAS and expose it to the HAOS machine. Any thoughts from the assembled experts here? TIA C
Zigbee
Single protocol?
CatmanV2C
Another question to the hive mind. Prompted by the fact that I lost yet another z-wave device over the weekend due to a power issue. It looks like z-way server is reporting another device failed (although it's working fine) and message queue is far too long IMHO. Also the failed device has been removed in the expert interface, but still there in the 'normal' one. Sigh. Currently I have z-wave, Tuya, thinking about Zigbee.... Does anyone use one single protocol for everything? Right now I'm feeling that as the z-wave stuff dies, I'm just gonna replace it with something else.... C
General Discussion
HDMI oddness
CatmanV2C
Not really Smart Home stuff, but going to ask as we have smart people... Bear with me on this one. Asking here because of the font of knowledge! For many eek years I have had a Virgin V6 box and a Raspberry Pi running Kodi connected to my TV through a cheap *** HDMI switch. It all worked beautifully but the absolutely critical thing was that the TV remote passed the signals back to the Pi to allow remote control of Kodi. Couple of changes of late: Installed a soundbar on the TV using the ARC (audio return channel). That then turns the soundbar on and off when the TV turns on and off and the TV volume control controls the soundbar volume direct. Everything continues to work Upgraded the software of the Tivo box to Virgin 360. This is literally software only. You get sent a snacky new Bluetooth remote hit 'upgrade' on the screen and off it goes. Now, things are not playing well. Typically when I turn on to watch Kodi the soundbar comes on (as it should) but the TV either puts out sound through its own speakers and the soundbar, or just the soundbar. It's not possible to control the volume of the soundbar through the TV. Also it's not longer possible to control Kodi using the TV remote. If I turn the TV360 box off, i.e. power it down, before turning on to watch Kodi, everything is fine. This makes little to no sense to me. My assumption is that the cheap *** HDMI switch is getting something from the TV360 connection that it didn't used to get when the software was Tivo and that's screwing up the HDMI communications. I'm upgrading the switch to something a little less chap, but wondered if anyone could validate my theory at all? TIA C
General Discussion
Reactor Loading Screen Safari
S
Topic thumbnail image
Multi-System Reactor
Constraints states visually do not match actual
S
Topic thumbnail image
Multi-System Reactor
Oh the joy of pairing
CatmanV2C
When I remember the old days Just added a new Tuya plug (OK so it's cloud) Start to finish, visible in HA and MSR < 30 seconds... C
Vera
Home Assistant Connect ZWA-2 & ZBT-2
therealdbT
Topic thumbnail image
Hardware
[MSR] Feature request: For Each action on arrays/groups
therealdbT
Topic thumbnail image
Multi-System Reactor
About
Posts
76
Topics
9
Shares
0
Groups
0
Followers
0
Following
0

Posts

Recent Best Controversial

  • Z-way token Expiration
    P powisquare

    All good - much appreciated.

    Zway Bridge

  • openLuup: MQTT server
    P powisquare

    Sorry - my bad. Device that's working does not have a password. I'll have another go.

    Boom - all working

    openLuup

  • openLuup: MQTT server
    P powisquare

    Yes I have - on all of them. I seem to recall, when setting up the first one, that openLuup recognised a button press. Perhaps that's how it worked. These sensors wake up on an hourly basis, but when you wake them up manually they are awake for a minute or so (it seems).

    openLuup

  • openLuup: MQTT server
    P powisquare

    Should have looked first ! Red highlights a win here; am seeing this ... (is there a proper way of copying and pasting?)

    2021-06-12 11:10:01.904 openLuup.server:: GET /data_request?id=lu_status2&output_format=json&DataVersion=492370363&Timeout=60&MinimumDelay=1500&_=1623492371898 HTTP/1.1 tcp{client}: 0x1e96db0
    2021-06-12 11:10:19.108 openLuup.io.server:: MQTT:1883 connection from 192.168.1.156 tcp{client}: 0x1d97790
    2021-06-12 11:10:19.152 openLuup.mqtt:: shellyht-E01A8B SUBSCRIBE to shellies/command tcp{client}: 0x1d97790
    2021-06-12 11:10:19.153 openLuup.mqtt:: shellyht-E01A8B SUBSCRIBE to shellies/shellyht-E01A8B/command tcp{client}: 0x1d97790
    2021-06-12 11:10:19.156 luup.shelly:83: New Shelly announced: shellyht-E01A8B
    2021-06-12 11:10:19.279 openLuup.context_switch:: ERROR: [dev #83] ./openLuup/client.lua:96: missing realm or nonce in received WWW-Authenticate header
    2021-06-12 11:10:19.280 openLuup.mqtt:: ERROR publishing application message for mqtt:shellies/announce : ./openLuup/client.lua:96: missing realm or nonce in received WWW-Authenticate header
    2021-06-12 11:10:19.393 openLuup.server:: request completed (1891 bytes, 1 chunks, 17488 ms) tcp{client}: 0x1e96db0

    openLuup

  • Z-way token Expiration
    P powisquare

    Updated openLuup to v. 21.6.8 yesterday. I notice the z-way bridge has lost connection. and requires login. When I go to device/actions there is no way to enter credentials - only a login button.

    Zway Bridge

  • openLuup: MQTT server
    P powisquare

    The first Shelly I tried worked with the bridge created and device created in the Shellies room. The next ones also appear in openLuup/Servers/Received Connections list but don't appear as devices. Have I missed a step?

    openLuup

  • openLuup: MQTT server
    P powisquare

    OMG. Genius. Many thanks indeed! Note to self - for Shelly .. Internet & Security/Advanced - Developer Settings/Enable MQTT

    openLuup

  • openLuup: MQTT server
    P powisquare

    Will I need to set ports or do anything in Lua Startup still?

    openLuup

  • openLuup: MQTT server
    P powisquare

    Hi guys - just received some Shelly H & Ts. Is there any documentation on how to connect these to mqtt (in novice speak 🙂)? Have read the thread but am getting slightly confused - do I need just the openluup mqtt server or another plugin also?

    openLuup

  • ubiquiti breach
    P powisquare

    Did you ever get a certificate on to your controller? Would love to get Let's Encrypt on but I wonder if they are making it difficult so people go for their cloud solution.

    General Discussion

  • Secure/Horstmann thermostat/zway
    P powisquare

    Not using the button - don't really know what it does.

    Hardware

  • Secure/Horstmann thermostat/zway
    P powisquare

    Thanks, only difference is Brand; I have Horstman (Secure), all versions and command classes are the same. I get the same error using openLuup interface too. Think this is the part where setpoint is accepted. Do you use the button for anything?

    [2021-03-22 09:05:40.517] [D] [zway] SETDATA devices.42.data.lastReceived = 0 (0x00000000)
    [2021-03-22 09:05:40.517] [I] [zway] Node 42:0 CC Wakeup: Wakeup notification
    [2021-03-22 09:05:40.517] [D] [zway] SETDATA devices.42.instances.0.commandClasses.132.data.lastWakeup = 1616403940 (0x60585de4)
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.data.isAwake = True
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.data.lastSendInternal = **********
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.data.lastNonceGet = 47091702 (0x02ce8ff6)
    [2021-03-22 09:05:40.518] [D] [zway] Running wakeup handler for node 42
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.instances.0.commandClasses.132.data.lastSleep = 1616403940 (0x60585de4)
    [2021-03-22 09:05:40.518] [I] [zway] Node 42:0 CC Wakeup: Send node to sleep
    [2021-03-22 09:05:40.518] [I] [zway] Adding job: Wakeup Sleep
    [2021-03-22 09:05:40.518] [D] [zway] SENDING (cb 0xfc): ( 01 0D 00 13 2A 06 43 01 01 22 00 6E 05 FC 3B )
    [2021-03-22 09:05:40.525] [D] [zway] RECEIVED ACK
    [2021-03-22 09:05:40.527] [D] [zway] RECEIVED: ( 01 04 01 13 01 E8 )
    [2021-03-22 09:05:40.528] [D] [zway] SENT ACK
    [2021-03-22 09:05:40.528] [D] [zway] Delivered to Z-Wave stack
    [2021-03-22 09:05:40.548] [D] [zway] RECEIVED: ( 01 18 00 13 FC 00 00 02 00 B0 7F 7F 7F 7F 01 01 03 00 00 00 00 02 01 00 00 BA )
    [2021-03-22 09:05:40.548] [D] [zway] SENT ACK
    [2021-03-22 09:05:40.548] [I] [zway] Job 0x13 (ThermostatSetPoint Set): Delivered
    [2021-03-22 09:05:40.549] [D] [zway] SendData Response with callback 0xfc received: received by recipient
    [2021-03-22 09:05:40.549] [D] [zway] SETDATA devices.42.data.lastSendInternal = **********
    [2021-03-22 09:05:40.549] [D] [zway] SETDATA devices.42.data.lastSend = 47092706 (0x02ce93e2)
    [2021-03-22 09:05:40.549] [D] [zway] Job 0x13 (ThermostatSetPoint Set): success
    [2021-03-22 09:05:40.549] [I] [zway] Removing job: ThermostatSetPoint Set

    Hardware

  • Secure/Horstmann thermostat/zway
    P powisquare

    Thanks - yes from zway basic interface.

    Hardware

  • Secure/Horstmann thermostat/zway
    P powisquare

    Seems to be working fine except I get an error notification via email 'Error during perform command execution: Error: Invalid argument' every time setpoint is changed from controller. Also does anyone know if the 'Button' child is useful?

    [2021-03-22 09:00:03.113] [I] [core] --- ZWayVDev_zway_42-0-67-1 performCommand processing: {"0":"exact","1":{"level":"11"}}
    [2021-03-22 09:00:03.113] [D] [zway] SETDATA devices.42.instances.0.commandClasses.67.data.1.setVal = 11.000000
    [2021-03-22 09:00:03.114] [I] [zway] Adding job: ThermostatSetPoint Set
    [2021-03-22 09:00:03.114] [I] [zway] Adding job: ThermostatSetPoint Get
    [2021-03-22 09:00:03.114] [I] [zway] Node 42:0 CC ThermostatMode: Thermostat Mode 1 is not supported by device (modemask 0x0)
    [2021-03-22 09:00:03.117] [I] [core] Notification: error (module): Error during perform command execution: Error: Invalid argument
    [2021-03-22 09:00:03.125] [I] [core] Error: Invalid argument
    at Error (native)
    at t_vDev.(anonymous function).self.controller.devices.create.handler (automation/modules/ZWave/index.js:5540:62)
    at .extend.performCommand (automation/classes/VirtualDevice.js:365:25)
    at ZAutomationAPIWebRequest.
    .extend.performVDevCommandFunc (automation/ZAutomationAPIProvider.js:442:51)
    at ZAutomationAPIWebRequest.handlerFunc (automation/ZAutomationAPIProvider.js:3976:30)
    at ZAutomationAPIWebRequest.ZAutomationWebRequest.handleRequest (automation/WebserverRequestRouter.js:250:35)
    at automation/WebserverRequestRouter.js:32:29
    at WebServer.document_root (automation/Webserver.js:40:31)
    [2021-03-22 09:00:03.130] [I] [core] HK: updated ZWayVDev_zway_42-0-67-1
    [2021-03-22 09:00:03.137] [D] [zway] RECEIVED: ( 01 18 00 13 F0 00 00 05 01 C4 7F 7F 7F 7F 00 00 03 2E 00 00 00 03 01 00 00 EB )

    Hardware

  • Why Migrate to Z-way from vera and how?
    P powisquare

    +1 for zway 🙂

    Zway Bridge

  • altUI
    P powisquare

    May well be different machines, differing firmwares. Frustrating nevertheless. Here's a stab at displaying variables.

    varaibles1.jpg

    Vera/openLuup plugins

  • altUI
    P powisquare

    Thanks - will have to try tomorrow - can't risk sending vera in to a tiz with guests staying.

    Vera/openLuup plugins

  • altUI
    P powisquare

    Can i set them to (0,0) as the (5,1) misbehaves?

    Vera/openLuup plugins

  • altUI
    P powisquare

    Sorry I was conflating issues. I have (a) two thermostats on separate veras that have different jsons and (b) one of those thermostats is shown above has the same json as another thermostat (on zway) but different functionality. Kinda got that muddled.

    Vera/openLuup plugins

  • altUI
    P powisquare

    Seems odd that it's two different jsons for the same thermostat on separate veras. Perhaps the issue is inherently an altui one anyway. When I use the up down arrows for temp setpoint it starts from the cooling setting ie in this case 0 so its a lot of clicking to get to 20.

    thermostat.jpg

    The same model thermostat paired to zway displays and behaves correctly with no cooling temps.

    TRthermostat.jpg

    But they have the same json?

    thermostatattributes.jpg

    Vera/openLuup plugins