[Reactor] Variables not updating correctly in latest-25201-2aa18550
therealdbT
Topic thumbnail image
Multi-System Reactor
Shelly Wall Display XL
therealdbT
I don't know if you guys are into dashboards, but I am. For a second home I tried the Shelly Wall Display 2, and while not so big, it worked well over the summer. Since we're remodeling our house, I just swapped my old Fire Tablet (with its own problems) with two new Shelly Wall Display XL. I just removed the standard firmware, and I added mine (https://github.com/dbochicchio/ShellyElevate), forked from https://github.com/RapierXbox/ShellyElevate I just managed to support buttons (this thing has 4 of them) and it's all auto-discovered by Home Assistant and accessible via Reactor. I also have a new build in the works with support for buttons inside HA. I added a bonus Javascript interface sending events (screen/screensaver status, buttons, motion) to automatically drive the dashboard (all doing in HTML+Javascript and monitoring Reactor's variable). This specifical thing excluded, go get one of them, the device has a decent CPU for HA dashboards and blends wonderfully in the decor.
Hardware
Handling Dead Entities and Renamed Entities
PablaP
Hello all.. been a minute! I recently rebuilt my Z wave network and migrated to a new z wave stick. In order to prevent any downtime I kept my original z wave network up and ran a docker version of Z Wave JS UI with my new controller. This way I could add device by device without having any devices down. I finally moved all the devices over to my new stick today. The final step was to migrate everything from my Docker instance of Z Wave JS UI to the HA add-on of Z Wave JS UI. However during this migration some of the names didn't populate correctly which I later managed to import back into Z Wave JS UI. The issue was in Reactor it is stuck on the default names and the entities are not updating. I removed the controller from Reactor, restarted, hard refreshed, and added the controller back however the new entity names have not updated. Also it seems like the old entities from my previous instance of Z Wave JS UI are lingering and not being marked as dead (I believe a certain amount of time needs to lapse before they're marked as dead in Reactor). My goal is to basically purge all the entities for the 'ZWaveJS' controller in Reactor so it can pull all the updated entity names and only the entities that exist in Z Wave JS UI. I cannot find a quick way to do this, I know entities can be deleted one by one, but with over 100 entities this would take long I am guessing that if I added the controller with a new name in in the Reactor config it would pull the updated entities and names but I think that would break my rules since the entity IDs would change (I made sure to name all the entities the exact same as they were previously to prevent this issue).
Multi-System Reactor
Strange behavior for MQTT templates using payload and attributes
therealdbT
Topic thumbnail image
Multi-System Reactor
[MSR] reactor-mqtt-contrib package for additional MQTT templates
therealdbT
I'm slowly migrating all my stuff to MQTT under MSR, so I have a central place to integrate everything (and, in a not-so-distant future, to remove virtual devices from my Vera and leave it running zwave only). Anyway, here's my reactor-mqtt-contrib package: https://github.com/dbochicchio/reactor-mqtt-contrib Simply download yaml files (everything or just the ones you need) and you're good to go. I have mapped my most useful devices, but I'll add others soon. Feel free to ask for specific templates, since I've worked a lot in the last weeks to understand and operate them. The templates are supporting both init and query, so you have always up-to-date devices at startup, and the ability to poll them. Online status is supported as well, so you can get disconnected devices with a simple expression. Many-many thanks to @toggledbits for its dedication, support, and patience with me and my requests
Multi-System Reactor
HA 2025.9.4 Supported Yet?
CatmanV2C
Tangentially did I miss 2025.9.4 getting blessed in MSR? I've been holding off Cheers C
Multi-System Reactor
The reaction stopped working (Google Nest max playing a video)
F
Topic thumbnail image
Multi-System Reactor
Rule Set UI bug - RESOLVED
3
Topic thumbnail image
Multi-System Reactor
[Reactor] Copy&Paste of Rules
therealdbT
I don't know if I'm the only one, but managing more than one Reactor installs, the need to have some sort of copy&paste for rules has grown on me. While I understand the technical challenges, I'm wondering if a "god mode" where I could copy the raw JSON rule and paste it into another rule could be an advanced, flag only feature that could benefit power users. I know I can copy the JSON file and proceed, but I must stop Reactor and when doing maintenance, it's more clicks to do. Just an idea
Multi-System Reactor
[Reactor] Help with screne controller cycling logic
therealdbT
I’ve added a couple of Shelly Wave i4 as scene controllers and I’m planning to add more, since I can just use standard buttons instead of battery-powered scene controllers, which also looks better aesthetically. That said, I’m struggling to figure out how to write a simple rule that cycles between states every time I press a button. Example: Light 1 ON → OFF, then Light 2 ON → OFF. The part I can’t get right is handling the case where Light 1 or Light 2 might already be ON independently of the rule. Maybe it’s just too much sun and relaxation clouding my brain, but any hint would be appreciated.
Multi-System Reactor
Stop the MSR by an external switch on Hubitat.
wmarcolinW
Use case: When performing home maintenance, such as air conditioning, I want all rules involving air conditioning to be disabled. To do this, to day, I have a virtual switch that I placed within all rules involving air conditioning, meaning that if I turn it off, none of them work. Then another situation: the water pump system and garden irrigation, another switch. In short, I had to create several virtual switches in Hubitat to disable rules in MSR. Unfortunately, however, I was unable to cover all scenarios, so I wondered if it would be possible for MSR to support a virtual MSR switch, which, when configured in the reactor settings, would function as a general on/off switch for MSR. If it is configured and turned off, the entire rules and actions in MSR stops working, except for the status change reading process, specifically for this switch, which, when turned on, would restart the MSR. Would it be possible to do something like this? Any recommendations from the experts?
Multi-System Reactor
Expose MSR entities
CatmanV2C
Probably a really dumb question. Currently I am using the owntracks_sensor for tracking phones being in region in MSR and it works great. Digging around with Home Assistant and toying with some dashboards, is there any way of exposing that sensor to HA trivially? I could set MSR to trip a virtual switch in OpenLuup which can then be exposed to HA (with all my other Vera devices) but that feels a bit in-elegant if I can do it directly. Any thoughts? Apologies if the ask is not clear/ TIA C
Multi-System Reactor
Comment in Globa Expressions
Tom_DT
I have several Global Expressions that are set by a rule so the definition area is blank. I'd like to add a comment in this area that explains what is setting the value. Commenting in this area breaks the remote setting. Any way to document what is setting the GE?
Multi-System Reactor
Little Bobby tables...
CatmanV2C
...is back.... https://arstechnica.com/google/2025/08/researchers-use-calendar-events-to-hack-gemini-control-smart-home-gadgets/?utm_source=facebook&utm_medium=social&utm_campaign=dhfacebook&utm_content=null&fbclid=IwY2xjawMBq-pleHRuA2FlbQIxMQABHlSqIalzbz1IxcJFzlw8GBE6nC3FwvxcHgR370nJhogU6JjqbmRxG-lysqgh_aem_lx9XboYFKw9tpHnedGQKUA C
General Discussion
Home Assistant Voice TTS is Easy
toggledbitsT
Topic thumbnail image
Home Assistant
Play Audio through Home Assistant Voice Unit
toggledbitsT
Topic thumbnail image
Home Assistant
Home Assistant Voice
CatmanV2C
Has anyone had a play with the local voice control for HA? I've got one on order because... https://www.home-assistant.io/voice-pe/ C
Home Assistant
Unofficial thread for compatibility
tunnusT
As there are statements about compatibility for home assistant versions in MSR new version announcements (e.g. "HassController: Bless Hass to 2025.7.3"), I thought it would be good idea to track other controllers as well. As an example, I can confirm that build "latest-25208-c53e8513" works with Hubitat Elevation C-8 platform version 2.4.2.134 using Maker API. Updates: (the latest versions first in the list) OK: build "latest-25264-2fbe9217" with Hubitat C-8 platform v. 2.4.3.123
Multi-System Reactor
Gradually turn on lights.
Tom_DT
I have several lights that I would like to turn on very gradually over 15 or 20 seconds. from 0 to .25 in .01 increments. I have tried a few things that came nowhere near working, so here I am.
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
About
Posts
76
Topics
9
Shares
0
Groups
0
Followers
0
Following
0

Posts

Recent Best Controversial

  • Z-way token Expiration
    P powisquare

    All good - much appreciated.

    Zway Bridge

  • openLuup: MQTT server
    P powisquare

    Sorry - my bad. Device that's working does not have a password. I'll have another go.

    Boom - all working

    openLuup

  • openLuup: MQTT server
    P powisquare

    Yes I have - on all of them. I seem to recall, when setting up the first one, that openLuup recognised a button press. Perhaps that's how it worked. These sensors wake up on an hourly basis, but when you wake them up manually they are awake for a minute or so (it seems).

    openLuup

  • openLuup: MQTT server
    P powisquare

    Should have looked first ! Red highlights a win here; am seeing this ... (is there a proper way of copying and pasting?)

    2021-06-12 11:10:01.904 openLuup.server:: GET /data_request?id=lu_status2&output_format=json&DataVersion=492370363&Timeout=60&MinimumDelay=1500&_=1623492371898 HTTP/1.1 tcp{client}: 0x1e96db0
    2021-06-12 11:10:19.108 openLuup.io.server:: MQTT:1883 connection from 192.168.1.156 tcp{client}: 0x1d97790
    2021-06-12 11:10:19.152 openLuup.mqtt:: shellyht-E01A8B SUBSCRIBE to shellies/command tcp{client}: 0x1d97790
    2021-06-12 11:10:19.153 openLuup.mqtt:: shellyht-E01A8B SUBSCRIBE to shellies/shellyht-E01A8B/command tcp{client}: 0x1d97790
    2021-06-12 11:10:19.156 luup.shelly:83: New Shelly announced: shellyht-E01A8B
    2021-06-12 11:10:19.279 openLuup.context_switch:: ERROR: [dev #83] ./openLuup/client.lua:96: missing realm or nonce in received WWW-Authenticate header
    2021-06-12 11:10:19.280 openLuup.mqtt:: ERROR publishing application message for mqtt:shellies/announce : ./openLuup/client.lua:96: missing realm or nonce in received WWW-Authenticate header
    2021-06-12 11:10:19.393 openLuup.server:: request completed (1891 bytes, 1 chunks, 17488 ms) tcp{client}: 0x1e96db0

    openLuup

  • Z-way token Expiration
    P powisquare

    Updated openLuup to v. 21.6.8 yesterday. I notice the z-way bridge has lost connection. and requires login. When I go to device/actions there is no way to enter credentials - only a login button.

    Zway Bridge

  • openLuup: MQTT server
    P powisquare

    The first Shelly I tried worked with the bridge created and device created in the Shellies room. The next ones also appear in openLuup/Servers/Received Connections list but don't appear as devices. Have I missed a step?

    openLuup

  • openLuup: MQTT server
    P powisquare

    OMG. Genius. Many thanks indeed! Note to self - for Shelly .. Internet & Security/Advanced - Developer Settings/Enable MQTT

    openLuup

  • openLuup: MQTT server
    P powisquare

    Will I need to set ports or do anything in Lua Startup still?

    openLuup

  • openLuup: MQTT server
    P powisquare

    Hi guys - just received some Shelly H & Ts. Is there any documentation on how to connect these to mqtt (in novice speak 🙂)? Have read the thread but am getting slightly confused - do I need just the openluup mqtt server or another plugin also?

    openLuup

  • ubiquiti breach
    P powisquare

    Did you ever get a certificate on to your controller? Would love to get Let's Encrypt on but I wonder if they are making it difficult so people go for their cloud solution.

    General Discussion

  • Secure/Horstmann thermostat/zway
    P powisquare

    Not using the button - don't really know what it does.

    Hardware

  • Secure/Horstmann thermostat/zway
    P powisquare

    Thanks, only difference is Brand; I have Horstman (Secure), all versions and command classes are the same. I get the same error using openLuup interface too. Think this is the part where setpoint is accepted. Do you use the button for anything?

    [2021-03-22 09:05:40.517] [D] [zway] SETDATA devices.42.data.lastReceived = 0 (0x00000000)
    [2021-03-22 09:05:40.517] [I] [zway] Node 42:0 CC Wakeup: Wakeup notification
    [2021-03-22 09:05:40.517] [D] [zway] SETDATA devices.42.instances.0.commandClasses.132.data.lastWakeup = 1616403940 (0x60585de4)
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.data.isAwake = True
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.data.lastSendInternal = **********
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.data.lastNonceGet = 47091702 (0x02ce8ff6)
    [2021-03-22 09:05:40.518] [D] [zway] Running wakeup handler for node 42
    [2021-03-22 09:05:40.518] [D] [zway] SETDATA devices.42.instances.0.commandClasses.132.data.lastSleep = 1616403940 (0x60585de4)
    [2021-03-22 09:05:40.518] [I] [zway] Node 42:0 CC Wakeup: Send node to sleep
    [2021-03-22 09:05:40.518] [I] [zway] Adding job: Wakeup Sleep
    [2021-03-22 09:05:40.518] [D] [zway] SENDING (cb 0xfc): ( 01 0D 00 13 2A 06 43 01 01 22 00 6E 05 FC 3B )
    [2021-03-22 09:05:40.525] [D] [zway] RECEIVED ACK
    [2021-03-22 09:05:40.527] [D] [zway] RECEIVED: ( 01 04 01 13 01 E8 )
    [2021-03-22 09:05:40.528] [D] [zway] SENT ACK
    [2021-03-22 09:05:40.528] [D] [zway] Delivered to Z-Wave stack
    [2021-03-22 09:05:40.548] [D] [zway] RECEIVED: ( 01 18 00 13 FC 00 00 02 00 B0 7F 7F 7F 7F 01 01 03 00 00 00 00 02 01 00 00 BA )
    [2021-03-22 09:05:40.548] [D] [zway] SENT ACK
    [2021-03-22 09:05:40.548] [I] [zway] Job 0x13 (ThermostatSetPoint Set): Delivered
    [2021-03-22 09:05:40.549] [D] [zway] SendData Response with callback 0xfc received: received by recipient
    [2021-03-22 09:05:40.549] [D] [zway] SETDATA devices.42.data.lastSendInternal = **********
    [2021-03-22 09:05:40.549] [D] [zway] SETDATA devices.42.data.lastSend = 47092706 (0x02ce93e2)
    [2021-03-22 09:05:40.549] [D] [zway] Job 0x13 (ThermostatSetPoint Set): success
    [2021-03-22 09:05:40.549] [I] [zway] Removing job: ThermostatSetPoint Set

    Hardware

  • Secure/Horstmann thermostat/zway
    P powisquare

    Thanks - yes from zway basic interface.

    Hardware

  • Secure/Horstmann thermostat/zway
    P powisquare

    Seems to be working fine except I get an error notification via email 'Error during perform command execution: Error: Invalid argument' every time setpoint is changed from controller. Also does anyone know if the 'Button' child is useful?

    [2021-03-22 09:00:03.113] [I] [core] --- ZWayVDev_zway_42-0-67-1 performCommand processing: {"0":"exact","1":{"level":"11"}}
    [2021-03-22 09:00:03.113] [D] [zway] SETDATA devices.42.instances.0.commandClasses.67.data.1.setVal = 11.000000
    [2021-03-22 09:00:03.114] [I] [zway] Adding job: ThermostatSetPoint Set
    [2021-03-22 09:00:03.114] [I] [zway] Adding job: ThermostatSetPoint Get
    [2021-03-22 09:00:03.114] [I] [zway] Node 42:0 CC ThermostatMode: Thermostat Mode 1 is not supported by device (modemask 0x0)
    [2021-03-22 09:00:03.117] [I] [core] Notification: error (module): Error during perform command execution: Error: Invalid argument
    [2021-03-22 09:00:03.125] [I] [core] Error: Invalid argument
    at Error (native)
    at t_vDev.(anonymous function).self.controller.devices.create.handler (automation/modules/ZWave/index.js:5540:62)
    at .extend.performCommand (automation/classes/VirtualDevice.js:365:25)
    at ZAutomationAPIWebRequest.
    .extend.performVDevCommandFunc (automation/ZAutomationAPIProvider.js:442:51)
    at ZAutomationAPIWebRequest.handlerFunc (automation/ZAutomationAPIProvider.js:3976:30)
    at ZAutomationAPIWebRequest.ZAutomationWebRequest.handleRequest (automation/WebserverRequestRouter.js:250:35)
    at automation/WebserverRequestRouter.js:32:29
    at WebServer.document_root (automation/Webserver.js:40:31)
    [2021-03-22 09:00:03.130] [I] [core] HK: updated ZWayVDev_zway_42-0-67-1
    [2021-03-22 09:00:03.137] [D] [zway] RECEIVED: ( 01 18 00 13 F0 00 00 05 01 C4 7F 7F 7F 7F 00 00 03 2E 00 00 00 03 01 00 00 EB )

    Hardware

  • Why Migrate to Z-way from vera and how?
    P powisquare

    +1 for zway 🙂

    Zway Bridge

  • altUI
    P powisquare

    May well be different machines, differing firmwares. Frustrating nevertheless. Here's a stab at displaying variables.

    varaibles1.jpg

    Vera/openLuup plugins

  • altUI
    P powisquare

    Thanks - will have to try tomorrow - can't risk sending vera in to a tiz with guests staying.

    Vera/openLuup plugins

  • altUI
    P powisquare

    Can i set them to (0,0) as the (5,1) misbehaves?

    Vera/openLuup plugins

  • altUI
    P powisquare

    Sorry I was conflating issues. I have (a) two thermostats on separate veras that have different jsons and (b) one of those thermostats is shown above has the same json as another thermostat (on zway) but different functionality. Kinda got that muddled.

    Vera/openLuup plugins

  • altUI
    P powisquare

    Seems odd that it's two different jsons for the same thermostat on separate veras. Perhaps the issue is inherently an altui one anyway. When I use the up down arrows for temp setpoint it starts from the cooling setting ie in this case 0 so its a lot of clicking to get to 20.

    thermostat.jpg

    The same model thermostat paired to zway displays and behaves correctly with no cooling temps.

    TRthermostat.jpg

    But they have the same json?

    thermostatattributes.jpg

    Vera/openLuup plugins