Skip to content
  • Categories
  • Recent
  • Tags
  • Popular
  • Unsolved
Collapse
Discussion Forum to share and further the development of home control and automation, independent of platforms.
  1. Home
  2. Software
  3. Multi-System Reactor
  4. Multidimensional Array
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor
Custom capabilities in MQTT templates
M
Hi, I'm trying to integrate the sonos-mqtt (https://sonos2mqtt.svrooij.io/) with the MSR and it's coming along nicely so far. But cannot wrap my head around how to define custom capabilities in MQTT templates. I need this for the TTS announcements and similarly for the notification sounds where I would pass the sound file as parameter. So this is what I have in the local_mqtt_devices.yaml capabilities: x_sonos_announcement: attributes: actions: speak: arguments: text: type: string volume: type: int delay: type: int And this is the template: templates: sonos-announcement: capabilities: - x_sonos_announcement actions: x_sonos_announcement: speak: topic: "sonos/cmd/speak" payload: expr: > { "text": parameters.text, "volume": parameters.volume, "delayMs": parameters.delay, "onlyWhenPlaying": false, "engine": "neural" } type: json So the speak action should send something like this to topic sonos/cmd/speak { "text": "message goes here", "volume": 50, "delayMs": 100, "onlyWhenPlaying": false, "engine": "neural" } At startup the MSR seems to be quite unhappy with my configuration: reactor | [latest-25016]2025-02-09T08:19:59.029Z <MQTTController:WARN> MQTTController#mqtt entity Entity#mqtt>sonos-announcement unable to configure capabilities [Array][ "x_sonos_announcement" ] reactor | i18n: missing fi-FI language string: Configuration for {0:q} is incomplete because the following requested capabilities are undefined: {1} reactor | i18n: missing fi-FI language string: Configuration for {0:q} has unrecognized capability {1:q} in actions reactor | Trace: Configuration for {0:q} is incomplete because the following requested capabilities are undefined: {1} reactor | at _T (/opt/reactor/server/lib/i18n.js:611:28) reactor | at AlertManager.addAlert (/opt/reactor/server/lib/AlertManager.js:125:25) reactor | at MQTTController.sendWarning (/opt/reactor/server/lib/Controller.js:627:30) reactor | at MQTTController.start (/var/reactor/ext/MQTTController/MQTTController.js:268:26) reactor | at async Promise.allSettled (index 0) Configuration for "sonos-announcement" has unrecognized capability "x_sonos_announcement" in actions Controller: MQTTController#mqtt Last 10:21:37 AM Configuration for "sonos-announcement" is incomplete because the following requested capabilities are undefined: x_sonos_announcement Controller: MQTTController#mqtt Last 10:21:37 AM This is probably a pretty stupid question and the approach may not even work at all, but maybe someone or @toggledbits for sure, could point me to the right direction. Basically the idea is to be able to send TTS messages from reactions using entity actions. I've previously used HTTP requests to Sonos HTTP API (https://hub.docker.com/r/chrisns/docker-node-sonos-http-api/) for the same functionality, but since moving to sonos-mqtt, I need a way to send the TTS notifications using MQTTController. Along with the actual message, volume and delay must also be parameterizable. br, mgvra MSR latest-25016-d47fea38 / MQTTController [0.2.24293]
Multi-System Reactor
[SOLVED]Hass websocket falsely reporting ready on boot??
V
Hi, @toggledbits I just noticed that following a reboot of my raspberry pi, some of the rules, that I was expecting to recover, are not catching up following a reboot. I have made a simple test rule (rule-m6rz6ol1) with only "after Date/time" as trigger and "turn on a lamp" as a set reaction. All my infrastructure is on the same board so Reactor, Hass, Zwavejs, ... are all rebooting. Here is the sequence of the test case (All time converted to Zulu to match logs): Rule "after Date/Time" set to 14:05:00z Shutdown on Raspberry Pi at 14:04:00z Power back up at 14:08:00z Rule overview shows true as of 14:08:14z waiting for 00:00:00 in GUI From the log I can see that MSR is picking up the rule and knows that the state of the rule has changed from false to true and tries to send the update to HASS but failed with websocket error. Here is what I see from the log: 14:04:04z shutdown complete 14:08:08z Power up 14:08:13.111z websocket connection 14:08:15:323z Reaction to the light failed, Websocket not opened After there is a series of websocket connection attempt until 14:08:51z where it seemed to be really ready. Back in 2021 we had a discussion (https://smarthome.community/topic/700/solved-start-up?_=1738766986566) and you proposed to add a startup_delay:xxxx and startup_wait:xxxx parameter in the engine section of "reactor.yaml". When I try the startup_delay (this used to be a hard delay), the engine failed to start (I think). I then try the startup_wait:xxxx without any success. Since it wait for the connection status to be up to cancel the delay, it does not do anyting since Hass is reporting the socket up without really being up ( I think...). Questions: Did I figured it all wrong? should the startup_delay:xxxxx have worked? Any ideas? Here is the log: OK now I am stuck. I did add the log but when I submit the editor complained saying that I am limited to 32767 characters. The log from the shutdown to the time the websocket is stable is about 300000 character long. What are my options?
Multi-System Reactor

Multidimensional Array

Scheduled Pinned Locked Moved Multi-System Reactor
28 Posts 3 Posters 1.9k Views 2 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • ElcidE Elcid

    @toggledbits said in Multidimensional Array:

    There is no === operator in the expression language, it's just ==

    Not according to your doc's.
    Screenshot_20211126-211238.png

    Also used in a test expression and working.

    Screenshot_20211126-211533.png

    Noted used "in" rather than "of" as I thought he wanted a 2D array not a object/dictionary.

    wmarcolinW Offline
    wmarcolinW Offline
    wmarcolin
    wrote on last edited by
    #12

    @elcid actually, for the final search result, it was easier with object/dictionary, but it could have been done by array as well. Thanks, you also taught me how to make an array that will be useful for sure, it always is.

    1 Reply Last reply
    0
    • ElcidE Elcid

      @toggledbits said in Multidimensional Array:

      There is no === operator in the expression language, it's just ==

      Not according to your doc's.
      Screenshot_20211126-211238.png

      Also used in a test expression and working.

      Screenshot_20211126-211533.png

      Noted used "in" rather than "of" as I thought he wanted a 2D array not a object/dictionary.

      toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by toggledbits
      #13

      @elcid said in Multidimensional Array:

      Not according to your doc's.

      You are correct, I'm suffering from holiday brain-fade.

      @wmarcolin Version 21331 just released has the first release of dynamic groups. It also includes a syntax enhancement to the expression first...in statement to allow a result expression, so it can return something other than what it finds (i.e. it can perform operations on what it finds and return that as a result). This is useful for your var4 of this post, which should be first dev,id of devices: dev.group=="DevDoor": id to give you the ID of the first matching device. But again, I think the combination of primary attribute assignment and dynamic groups is going to be the best way to solve this.

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      wmarcolinW 2 Replies Last reply
      0
      • toggledbitsT toggledbits

        @elcid said in Multidimensional Array:

        Not according to your doc's.

        You are correct, I'm suffering from holiday brain-fade.

        @wmarcolin Version 21331 just released has the first release of dynamic groups. It also includes a syntax enhancement to the expression first...in statement to allow a result expression, so it can return something other than what it finds (i.e. it can perform operations on what it finds and return that as a result). This is useful for your var4 of this post, which should be first dev,id of devices: dev.group=="DevDoor": id to give you the ID of the first matching device. But again, I think the combination of primary attribute assignment and dynamic groups is going to be the best way to solve this.

        wmarcolinW Offline
        wmarcolinW Offline
        wmarcolin
        wrote on last edited by
        #14

        @toggledbits Hi!

        Perfect, you have totally changed the command.

        first dev,id in var1 with dev.group=="DevDoor": dev.devid

        I'm going to study the dynamic group, because even though I can compare object or array contents, the usage is horrible. It's very difficult to validate an array inside another one, or to make combined selections.

        Well, I don't really know the language, so I'm having a hard time. Let's see if the dynamic groups can make something that should be simple easier.

        I'll return tomorrow with my experiences 🙂

        1 Reply Last reply
        0
        • toggledbitsT toggledbits

          @elcid said in Multidimensional Array:

          Not according to your doc's.

          You are correct, I'm suffering from holiday brain-fade.

          @wmarcolin Version 21331 just released has the first release of dynamic groups. It also includes a syntax enhancement to the expression first...in statement to allow a result expression, so it can return something other than what it finds (i.e. it can perform operations on what it finds and return that as a result). This is useful for your var4 of this post, which should be first dev,id of devices: dev.group=="DevDoor": id to give you the ID of the first matching device. But again, I think the combination of primary attribute assignment and dynamic groups is going to be the best way to solve this.

          wmarcolinW Offline
          wmarcolinW Offline
          wmarcolin
          wrote on last edited by
          #15

          @toggledbits

          Hi Patrick!
          I don't know if I'm doing something wrong, but I followed the following steps to use DynamicGroupController.

          1. Stopped the MSR
          2. Compared the reactor configuration file
          3. Added the new Groups instruction, the one in the file is almost the same as the manual, and below is the one I set up.
            - id: groups
              enable: true
              implementation: DynamicGroupController
              name: Dynamic Group Controller
              config:
                groups:
                  "low_battery":
                    name: Low Battery Devices
                    select:
                      - include_capability: 
                        - battery_power
                    filter_expression: > 
                      entity.attributes.battery_power.level < 0.35
                  "tripped":
                    name: Tripped Devices
                    select:
                      - include_capability: 
                        - binary_sensor
                        - motion_sensor
                    filter_expression: >
                      entity.attributes.binary_sensor.state == true or
                      entity.attributes.motion_sensor.state == true
          
          
          1. I restarted MSR + Tools Restart + Crtl+F5 🙂
          2. Search in Entities and I see that they are created, but without content

          7e621920-da8d-439e-b2b0-7018f0720fd1-image.png

          5e7fafc0-8c76-4868-95ce-4a4722cb6466-image.png

          1. Check if they are available for action, yes but also without content.

          332057ab-7718-4cc2-9253-dc5d33e2dd58-image.png

          1. As the master instructed, let's go to the log file.
          [latest-21331]2021-11-27T21:13:45.136Z <default:INFO> OWMWeatherController#weather done; 1 locations, 0 failed
          [latest-21331]2021-11-27T21:13:45.137Z <default:NOTICE> Controller OWMWeatherController#weather is now online.
          [latest-21331]2021-11-27T21:13:46.538Z <VeraController:NOTICE> Controller VeraController#vera is now online.
          [latest-21331]2021-11-27T21:13:46.540Z <default:ERR> error updating dynamic group low_battery_entries: Error: Invalid selector key
          [latest-21331]2021-11-27T21:13:46.541Z <default:CRIT> Error: Invalid selector key
          Error: Invalid selector key
              at DynamicGroupController._select (C:\MSR\reactor\server\lib\DynamicGroupController.js:260:23)
              at DynamicGroupController._update_group (C:\MSR\reactor\server\lib\DynamicGroupController.js:193:45)
              at C:\MSR\reactor\server\lib\DynamicGroupController.js:243:38
              at Array.forEach (<anonymous>)
              at DynamicGroupController._update (C:\MSR\reactor\server\lib\DynamicGroupController.js:240:95)
              at C:\MSR\reactor\server\lib\DynamicGroupController.js:150:42
              at processTicksAndRejections (node:internal/process/task_queues:96:5)
          [latest-21331]2021-11-27T21:13:46.543Z <default:ERR> error updating dynamic group tripped_entries: Error: Invalid selector key
          [latest-21331]2021-11-27T21:13:46.544Z <default:CRIT> Error: Invalid selector key
          Error: Invalid selector key
              at DynamicGroupController._select (C:\MSR\reactor\server\lib\DynamicGroupController.js:260:23)
              at DynamicGroupController._update_group (C:\MSR\reactor\server\lib\DynamicGroupController.js:193:45)
              at C:\MSR\reactor\server\lib\DynamicGroupController.js:243:38
              at Array.forEach (<anonymous>)
              at DynamicGroupController._update (C:\MSR\reactor\server\lib\DynamicGroupController.js:240:95)
              at C:\MSR\reactor\server\lib\DynamicGroupController.js:150:42
              at processTicksAndRejections (node:internal/process/task_queues:96:5)
          [latest-21331]2021-11-27T21:13:46.544Z <app:NOTICE> Starting HTTP server and API...
          [latest-21331]2021-11-27T21:13:46.552Z <app:NOTICE> Starting Reaction Engine...
          
          

          Well, I found this error, and obviously, I don't know how to solve it. What I did? I reinstalled the MSR, using only the config and storage directory, and the result is the same.

          1 Reply Last reply
          0
          • toggledbitsT Offline
            toggledbitsT Offline
            toggledbits
            wrote on last edited by
            #16

            The groups would be empty if there were no tripped or low battery devices in their respective groups, so that's not all conclusive; it may be perfectly correct. The groups at least appear to be correct, for empty groups (no entities matched).

            The time stamps in your log snippet are unrelated to the time stamp on the entities, so I can't really draw any conclusions from that either. If you post logs, make sure you are posting logs where the time stamps align to the problem you're reporting.

            On your conditions, you can't compare an array to an empty string; that's not a valid test.

            Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

            wmarcolinW 1 Reply Last reply
            0
            • toggledbitsT toggledbits

              The groups would be empty if there were no tripped or low battery devices in their respective groups, so that's not all conclusive; it may be perfectly correct. The groups at least appear to be correct, for empty groups (no entities matched).

              The time stamps in your log snippet are unrelated to the time stamp on the entities, so I can't really draw any conclusions from that either. If you post logs, make sure you are posting logs where the time stamps align to the problem you're reporting.

              On your conditions, you can't compare an array to an empty string; that's not a valid test.

              wmarcolinW Offline
              wmarcolinW Offline
              wmarcolin
              wrote on last edited by wmarcolin
              #17

              @toggledbits

              Ok let's go in parts, what I created in Group is the same thing I do in the traditional way and get the result, see the battery case.

              6bf50285-7862-4ba5-acd6-2c9eff9a0aec-image.png

              I'm not seeing an error anymore, after a reboot of the MSR host.

              [latest-21331]2021-11-28T02:45:18.584Z <default:null> Module httpapi v21308
              [latest-21331]2021-11-28T02:45:18.661Z <VeraController:null> Module VeraController v21324
              [latest-21331]2021-11-28T02:45:18.668Z <default:INFO> Structure#1 loading controller interface hubitat (HubitatController)
              [latest-21331]2021-11-28T02:45:18.676Z <HubitatController:null> Module HubitatController v21324
              [latest-21331]2021-11-28T02:45:18.679Z <default:INFO> Structure#1 loading controller interface groups (DynamicGroupController)
              [latest-21331]2021-11-28T02:45:18.686Z <DynamicGroupController:null> Module DynamicGroupController v21331
              [latest-21331]2021-11-28T02:45:18.688Z <default:INFO> Structure#1 loading controller interface weather (OWMWeatherController)
              [latest-21331]2021-11-28T02:45:18.693Z <OWMWeatherController:null> Module OWMWeatherController v21313
              
              
              [latest-21331]2021-11-28T02:45:18.761Z <default:INFO> Starting controller HubitatController#hubitat
              [latest-21331]2021-11-28T02:45:18.782Z <default:INFO> Starting controller DynamicGroupController#groups
              [latest-21331]2021-11-28T02:45:18.784Z <default:NOTICE> Controller DynamicGroupController#groups is now online.
              [latest-21331]2021-11-28T02:45:18.785Z <default:INFO> Starting controller OWMWeatherController#weather
              
              

              I see that the times are synchronized

              94523c4a-dd1f-4bc6-858a-351f010e4028-image.png

              But the array is still empty

              Any instructions where I can look for something?

              1 Reply Last reply
              0
              • toggledbitsT Offline
                toggledbitsT Offline
                toggledbits
                wrote on last edited by toggledbits
                #18

                The recommended debugging for this would be to start unraveling your criteria and see what it produces. As a first step (don't do this, just read), I would remove the filter_expression and make sure that your selectors are producing the expected set of eligible devices. An easy way to do that is to simply put an "X" in front of filter_expression (i.e. to make it Xfilter_expression), which changes the name of the key and hides it from the code that's looking for it. You could also comment it out, but that would require that you comment each subordinate line as well, which is more work and can be error-prone. Restart MSR after config changes, of course, and refreshes are also recommended (don't need to be hard refreshes).

                But, I found an error, and it's pretty subtle. For me, it logged one short line, so it would be easy to miss; I imagine you have it as well. But it's going to require a code change to fix, so I'll release another build later today. I'll also fix the doc issue you PM'd me about.

                Also, don't forget that filtering by controller or capability is a good way to quickly remove "noise" from your Entities list.

                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                wmarcolinW 2 Replies Last reply
                0
                • toggledbitsT toggledbits

                  The recommended debugging for this would be to start unraveling your criteria and see what it produces. As a first step (don't do this, just read), I would remove the filter_expression and make sure that your selectors are producing the expected set of eligible devices. An easy way to do that is to simply put an "X" in front of filter_expression (i.e. to make it Xfilter_expression), which changes the name of the key and hides it from the code that's looking for it. You could also comment it out, but that would require that you comment each subordinate line as well, which is more work and can be error-prone. Restart MSR after config changes, of course, and refreshes are also recommended (don't need to be hard refreshes).

                  But, I found an error, and it's pretty subtle. For me, it logged one short line, so it would be easy to miss; I imagine you have it as well. But it's going to require a code change to fix, so I'll release another build later today. I'll also fix the doc issue you PM'd me about.

                  Also, don't forget that filtering by controller or capability is a good way to quickly remove "noise" from your Entities list.

                  wmarcolinW Offline
                  wmarcolinW Offline
                  wmarcolin
                  wrote on last edited by
                  #19

                  @toggledbits

                  I debugged removing filter_axpression entirely, and the variables are still empty. I'll wait for your version update and test again.

                  1 Reply Last reply
                  0
                  • toggledbitsT toggledbits

                    The recommended debugging for this would be to start unraveling your criteria and see what it produces. As a first step (don't do this, just read), I would remove the filter_expression and make sure that your selectors are producing the expected set of eligible devices. An easy way to do that is to simply put an "X" in front of filter_expression (i.e. to make it Xfilter_expression), which changes the name of the key and hides it from the code that's looking for it. You could also comment it out, but that would require that you comment each subordinate line as well, which is more work and can be error-prone. Restart MSR after config changes, of course, and refreshes are also recommended (don't need to be hard refreshes).

                    But, I found an error, and it's pretty subtle. For me, it logged one short line, so it would be easy to miss; I imagine you have it as well. But it's going to require a code change to fix, so I'll release another build later today. I'll also fix the doc issue you PM'd me about.

                    Also, don't forget that filtering by controller or capability is a good way to quickly remove "noise" from your Entities list.

                    wmarcolinW Offline
                    wmarcolinW Offline
                    wmarcolin
                    wrote on last edited by
                    #20

                    @toggledbits well done

                    Low Battery Devices charging perfect!

                    a94effd2-b52f-4bf3-ac75-ddfd010df71d-image.png

                    But there is a problem for "tripped", which repeated the same setting as "low_battery".

                      - id: groups
                        enable: true
                        implementation: DynamicGroupController
                        name: Dynamic Group Controller
                        config:
                          groups:
                            "low_battery":
                              name: Low Battery Devices
                              select:
                                - include_capability: 
                                  - battery_power
                              filter_expression: > 
                                entity.attributes.battery_power.level < 0.3
                            "tripped":
                              name: Tripped Devices
                              select:
                                - include_capability: 
                                  - binary_sensor
                                  - motion_sensor
                              filter_expression: >
                                entity.attributes.binary_sensor.state == true or
                                entity.attributes.motion_sensor.state == true
                    

                    This is what is showing up in the log.

                    [latest-21332]2021-11-29T01:49:33.599Z <default:ERR> error updating dynamic group tripped: ReferenceError: Invalid reference to member state of null
                    [latest-21332]2021-11-29T01:49:33.600Z <default:CRIT> ReferenceError: Invalid reference to member state of null
                    ReferenceError: Invalid reference to member state of null
                        at _run (C:\MSR\reactor\common\lexp.js:1369:31)
                        at _run (C:\MSR\reactor\common\lexp.js:1233:34)
                        at _run (C:\MSR\reactor\common\lexp.js:1290:44)
                        at C:\MSR\reactor\common\lexp.js:1223:29
                        at Array.forEach (<anonymous>)
                        at _run (C:\MSR\reactor\common\lexp.js:1222:28)
                        at Object.run (C:\MSR\reactor\common\lexp.js:1564:22)
                        at DynamicGroupController._update_group (C:\MSR\reactor\server\lib\DynamicGroupController.js:229:141)
                        at C:\MSR\reactor\server\lib\DynamicGroupController.js:267:39
                        at Array.forEach (<anonymous>)
                    
                    

                    Would I have to include any additional information in the configuration to not have this problem with null?

                    1 Reply Last reply
                    0
                    • toggledbitsT Offline
                      toggledbitsT Offline
                      toggledbits
                      wrote on last edited by
                      #21

                      In your expression, you are not guarding for entities that have binary_sensor but do not have motion_sensor, and vice versa. Use the coalescing member access operator ?. in the two sub-expressions.

                      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                      wmarcolinW 1 Reply Last reply
                      0
                      • toggledbitsT toggledbits

                        In your expression, you are not guarding for entities that have binary_sensor but do not have motion_sensor, and vice versa. Use the coalescing member access operator ?. in the two sub-expressions.

                        wmarcolinW Offline
                        wmarcolinW Offline
                        wmarcolin
                        wrote on last edited by
                        #22

                        @toggledbits

                        Perfect, solved, after putting the ?. in several places until I discovered how to use it correctly 😁

                                "tripped":
                                  name: Tripped Devices
                                  select:
                                    - include_capability: 
                                      - binary_sensor
                                      - motion_sensor
                                  filter_expression: >
                                    entity.attributes?.binary_sensor?.state == true or
                                    entity.attributes?.motion_sensor?.state == true
                        
                        

                        Boss, this thread started because I want to associate to each device an information of which group it would belong inside my system, external information that I will have to prepare manually, we started with the array, then we went to object, until you announce this new function.

                        What is the way now? At this moment my progress is to have in a more simplified way the ID of the devices that will understand a condition, now how in the case of Tripped I will be able to associate to the groups, the list assembled before? I already saw that I can have a global variable with the information, that this Dynamic instruction by the manual will be able to read.

                        Could you put together an example please?

                        Thanks.

                        toggledbitsT 1 Reply Last reply
                        0
                        • wmarcolinW wmarcolin

                          @toggledbits

                          Perfect, solved, after putting the ?. in several places until I discovered how to use it correctly 😁

                                  "tripped":
                                    name: Tripped Devices
                                    select:
                                      - include_capability: 
                                        - binary_sensor
                                        - motion_sensor
                                    filter_expression: >
                                      entity.attributes?.binary_sensor?.state == true or
                                      entity.attributes?.motion_sensor?.state == true
                          
                          

                          Boss, this thread started because I want to associate to each device an information of which group it would belong inside my system, external information that I will have to prepare manually, we started with the array, then we went to object, until you announce this new function.

                          What is the way now? At this moment my progress is to have in a more simplified way the ID of the devices that will understand a condition, now how in the case of Tripped I will be able to associate to the groups, the list assembled before? I already saw that I can have a global variable with the information, that this Dynamic instruction by the manual will be able to read.

                          Could you put together an example please?

                          Thanks.

                          toggledbitsT Offline
                          toggledbitsT Offline
                          toggledbits
                          wrote on last edited by toggledbits
                          #23

                          @wmarcolin said in Multidimensional Array:

                          this thread started because I want to associate to each device an information of which group it would belong inside my system, external information that I will have to prepare manually

                          You still haven't stated why you want to do this, so in my view, we're on the Y of an X-Y problem. What you are asking seems an odd thing to do... error-prone, laborious, hard to maintain. If I understood why you think you need to do it, we might arrive at a better solution that works from existing functionality, or a clear requirement for a new feature. When I asked before for this clarification (and repair of the topic title), you replied with a restatement of your implementation question, not an explanation of the problem you are trying to solve (i.e. why you want to do the implementation you are asking about), just as you've again done now.

                          If I ask you how to ventilate an enclosed space that has small windows and a doorway that is usually left open, given no other information, what might you suggest?

                          Would you answer differently if I also told you in advance that the space will be a new module for the International Space Station?

                          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                          wmarcolinW 1 Reply Last reply
                          0
                          • toggledbitsT toggledbits

                            @wmarcolin said in Multidimensional Array:

                            this thread started because I want to associate to each device an information of which group it would belong inside my system, external information that I will have to prepare manually

                            You still haven't stated why you want to do this, so in my view, we're on the Y of an X-Y problem. What you are asking seems an odd thing to do... error-prone, laborious, hard to maintain. If I understood why you think you need to do it, we might arrive at a better solution that works from existing functionality, or a clear requirement for a new feature. When I asked before for this clarification (and repair of the topic title), you replied with a restatement of your implementation question, not an explanation of the problem you are trying to solve (i.e. why you want to do the implementation you are asking about), just as you've again done now.

                            If I ask you how to ventilate an enclosed space that has small windows and a doorway that is usually left open, given no other information, what might you suggest?

                            Would you answer differently if I also told you in advance that the space will be a new module for the International Space Station?

                            wmarcolinW Offline
                            wmarcolinW Offline
                            wmarcolin
                            wrote on last edited by
                            #24

                            @toggledbits

                            Ok, I will try to explain what I want to do.

                            When using Vera, I in the Dashboard > My Modes panel determined which devices could trigger the house alarm in a given mode. With the change to Hubitat has no equal to Vera, and also not wanting to depend on the hub anymore, I want to have total control of the situation.

                            I thought about creating device groups (yes manually for now), i.e.: door group, window group, motion sensors, sensors like CO and water, and devices that should alarm and are not in the other groups.

                            So when I activate for example the night mode I want to trigger the alarm if the devices that are in the door group are tripped. If I enter Away mode, I want to join the devices' doors, windows, and motion. In Vacation mode, I put everything together and monitor if any device is tripped to trigger the alarm.

                            Another example, I can put all the liquid sensor devices in a water detector group, so when I evaluate the rule I refer to the group, and not to each device. You could say more there, just see who has leak_detector_state, but as we discussed before there is no standard, remember the discussion of the binary_sensor standard?

                            Another situation we could put together, the same way I put the door and window group together in Away mode, I could use it to if nothing is tripped, allow the central air in the house to work.

                            Trying to make a summary is, in a single table (beginning of this thread), I determine which group the device belongs to and do actions by group and not having to identify each device, we can say that it would be the equivalent in Vera as category_num and subcategory_num, and again this is from Vera, and they made mistakes by not respecting the table they created and both icon and device behavior not working, but it was interesting the grouping table (http://wiki.micasaverde.com/index.php/Luup_Device_Categories).

                            That is why even in this thread I thought if there was a way to add a group attribute to the devices in the MSR table, and by a set variable align this information, it did not work because you explained that if it does not come from the hub, there is no way to load the information.

                            Did I succeed in explaining the scenario?

                            Where I am at this moment:

                            1. I created the object as you taught:
                              DeviceList = {
                              "vera>device_489": {group:"Door"},
                              "vera>device_432": {group:"Door"},
                              "hubitat>99": {group: "Window"},
                              "hubitat>15": {group: "Window"},
                              "vera>device_1672": {group:"Sensor"},
                              "vera>device_1867": {group:"Sensor"},
                              "vera>device_22": {group: "Security"},
                              "vera>device_1679": {group:"Security"},
                              "hubitat>1": {group: "Security"},
                              "vera>device_1822": {group:"Security"}
                              }
                            2. Now with Dynamic I have it easy that it is tripped;
                            3. I have a global variable that is loaded in each mode, DeviceAlarm, which is an object that I put who will be monitored in the activated mode, for example, set variable DeviceAlarm = ${{["Door", "Window"]}}.

                            What I don't know how to do now, I don't dominate the programming/language, is how to ask and/or put together Dynamic's tripped + DeviceList object + DeviceAlarm + Device name.

                            What do I look for? Who is Tripped (Dynamic Tripped), with the parameter filter (DeviceAlarm), in the device list (Object DeviceList)? Give me the device name in one variable, and a second variable the list of Groups that are tripped. In this second answer, I pass the list of what I want to look at in DeviceAlarm, but it should only return what is tripped.

                            Sorry for the bother, and you are right that I am joining topics from several different threads. I'm just trying to have something that could make the operation easier, and optimize the code in my view.

                            Thanks.

                            toggledbitsT 1 Reply Last reply
                            0
                            • wmarcolinW wmarcolin

                              @toggledbits

                              Ok, I will try to explain what I want to do.

                              When using Vera, I in the Dashboard > My Modes panel determined which devices could trigger the house alarm in a given mode. With the change to Hubitat has no equal to Vera, and also not wanting to depend on the hub anymore, I want to have total control of the situation.

                              I thought about creating device groups (yes manually for now), i.e.: door group, window group, motion sensors, sensors like CO and water, and devices that should alarm and are not in the other groups.

                              So when I activate for example the night mode I want to trigger the alarm if the devices that are in the door group are tripped. If I enter Away mode, I want to join the devices' doors, windows, and motion. In Vacation mode, I put everything together and monitor if any device is tripped to trigger the alarm.

                              Another example, I can put all the liquid sensor devices in a water detector group, so when I evaluate the rule I refer to the group, and not to each device. You could say more there, just see who has leak_detector_state, but as we discussed before there is no standard, remember the discussion of the binary_sensor standard?

                              Another situation we could put together, the same way I put the door and window group together in Away mode, I could use it to if nothing is tripped, allow the central air in the house to work.

                              Trying to make a summary is, in a single table (beginning of this thread), I determine which group the device belongs to and do actions by group and not having to identify each device, we can say that it would be the equivalent in Vera as category_num and subcategory_num, and again this is from Vera, and they made mistakes by not respecting the table they created and both icon and device behavior not working, but it was interesting the grouping table (http://wiki.micasaverde.com/index.php/Luup_Device_Categories).

                              That is why even in this thread I thought if there was a way to add a group attribute to the devices in the MSR table, and by a set variable align this information, it did not work because you explained that if it does not come from the hub, there is no way to load the information.

                              Did I succeed in explaining the scenario?

                              Where I am at this moment:

                              1. I created the object as you taught:
                                DeviceList = {
                                "vera>device_489": {group:"Door"},
                                "vera>device_432": {group:"Door"},
                                "hubitat>99": {group: "Window"},
                                "hubitat>15": {group: "Window"},
                                "vera>device_1672": {group:"Sensor"},
                                "vera>device_1867": {group:"Sensor"},
                                "vera>device_22": {group: "Security"},
                                "vera>device_1679": {group:"Security"},
                                "hubitat>1": {group: "Security"},
                                "vera>device_1822": {group:"Security"}
                                }
                              2. Now with Dynamic I have it easy that it is tripped;
                              3. I have a global variable that is loaded in each mode, DeviceAlarm, which is an object that I put who will be monitored in the activated mode, for example, set variable DeviceAlarm = ${{["Door", "Window"]}}.

                              What I don't know how to do now, I don't dominate the programming/language, is how to ask and/or put together Dynamic's tripped + DeviceList object + DeviceAlarm + Device name.

                              What do I look for? Who is Tripped (Dynamic Tripped), with the parameter filter (DeviceAlarm), in the device list (Object DeviceList)? Give me the device name in one variable, and a second variable the list of Groups that are tripped. In this second answer, I pass the list of what I want to look at in DeviceAlarm, but it should only return what is tripped.

                              Sorry for the bother, and you are right that I am joining topics from several different threads. I'm just trying to have something that could make the operation easier, and optimize the code in my view.

                              Thanks.

                              toggledbitsT Offline
                              toggledbitsT Offline
                              toggledbits
                              wrote on last edited by
                              #25

                              @wmarcolin Hubitat has modes, and it has the Hubitat Safety Monitor (HSM), both of which are supported by Reactor. HSM can set arming based on detection level, so it's worth looking into.

                              If you still want to keep it all off hub, I would simply make groups:

                              • door_sensors: include_capability: door_sensor
                              • leak_sensors: include_capability: leak_detector
                              • motion_sensors: include_capability: motion_sensor

                              The create "tripped" versions of each:

                              • door_sensors_tripped: include_group: door_sensors, filter_expr: entity.attributes.door_sensor.state
                              • leak_sensors_tripped: include_group: leak_sensors, filter_expr: entity.attributes.leak_detector.state
                              • etc.

                              Creating these extra tripped groups does two things for you: (1) it isolates the expression to the capability, so you don't have to worry about motion_sensor.state vs leak_detector.state within a single group, the group is homogenous; and (2) by segmenting the devices to type, you more easily make the conditions for what devices are active in what security mode.

                              Then in your alarm rules for Night, Away, Vacation modes, you check if the tripped group for each group you are interested in for that mode is empty or not. So for Night, you would only be checking door_sensors_tripped, while for Away it will be the tripped door, window, and motion groups.

                              3257062d-a0b7-4e7d-8b9e-36c79e029899-image.png

                              (ignore my group name -- I just picked a group I had to illustrate how the condition may be set up)

                              You don't need any variables at all (global or otherwise) to do what's described using dynamic groups.

                              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                              wmarcolinW 1 Reply Last reply
                              0
                              • toggledbitsT toggledbits

                                @wmarcolin Hubitat has modes, and it has the Hubitat Safety Monitor (HSM), both of which are supported by Reactor. HSM can set arming based on detection level, so it's worth looking into.

                                If you still want to keep it all off hub, I would simply make groups:

                                • door_sensors: include_capability: door_sensor
                                • leak_sensors: include_capability: leak_detector
                                • motion_sensors: include_capability: motion_sensor

                                The create "tripped" versions of each:

                                • door_sensors_tripped: include_group: door_sensors, filter_expr: entity.attributes.door_sensor.state
                                • leak_sensors_tripped: include_group: leak_sensors, filter_expr: entity.attributes.leak_detector.state
                                • etc.

                                Creating these extra tripped groups does two things for you: (1) it isolates the expression to the capability, so you don't have to worry about motion_sensor.state vs leak_detector.state within a single group, the group is homogenous; and (2) by segmenting the devices to type, you more easily make the conditions for what devices are active in what security mode.

                                Then in your alarm rules for Night, Away, Vacation modes, you check if the tripped group for each group you are interested in for that mode is empty or not. So for Night, you would only be checking door_sensors_tripped, while for Away it will be the tripped door, window, and motion groups.

                                3257062d-a0b7-4e7d-8b9e-36c79e029899-image.png

                                (ignore my group name -- I just picked a group I had to illustrate how the condition may be set up)

                                You don't need any variables at all (global or otherwise) to do what's described using dynamic groups.

                                wmarcolinW Offline
                                wmarcolinW Offline
                                wmarcolin
                                wrote on last edited by wmarcolin
                                #26

                                @toggledbits first of all thank you for the quick response, and this may be one way.

                                However (sorry), I see a disadvantage, we use the case of sensors with the attribute door_sensor they are valid for access doors to the house, but are also for windows (first and second floor of the house, and the second floor is not turned on in night mode), and the same attribute has the internal door sensors, which in this case I use for air conditioning management (open door turns off the air).

                                Another example would be the motion_sensor, I have internal and external sensors, in night mode the external ones turn on the garage and entrance lights, if I group everything by the attribute a movement inside the house would also trigger.

                                This way your proposal is very valid, but there should be a way to dismember the groups, i.e. door_sensors_group1 (external door), door_sensors_group2 (window 1), door_sensor_group3 (internal door).... that's why I thought about the table that could specify each device and not use an attribute that generalizes the devices.

                                This way your proposal is very valid, but there should be a way to dismember the groups, i.e. door_sensors_group1 (external door), door_sensors_group2 (window 1), door_sensor_group3 (internal door).... that's why I thought about the table that could specify each device and not use an attribute that generalizes the devices.

                                I don't know if there could be something in these instructions referring to the global object we commented on DeviceList.

                                door_sensors: include_capability: door_sensor %(#ff0000)[contained in DeviceList = "Door External".]

                                or would it be something in this instruction

                                door_sensors_tripped: include_group: door_sensors, filter_expr: entity.attributes.door_sensor.state %(#ff0000)[contained in DeviceList = "Door External".]

                                (please don't laugh at my coding, I said I don't know it))

                                The excellent thing is that we are going to take more automatic paths as you are commenting.

                                Despite not wanting to depend on a hub, I looked at the HSM option, I see that it would be possible to create the groups I have commented, now I did not understand your comment that the MSR would talk to the HSM.

                                In HSM the actions I see are alert by text, audio, siren or light. The way, in this case, would be to create a virtual device connected with HSM, and this one the MSR would monitor to take action?

                                In the Apps that I set up the MSR, I don't see the option to select on device the action I created in the HSM. I have the option Allow control of HSM activated. Do I have to configure anything to show up on the MSR?

                                Fact that I will not make Hubitat take action, who performs action in my solution is the MSR.

                                toggledbitsT 1 Reply Last reply
                                0
                                • wmarcolinW wmarcolin

                                  @toggledbits first of all thank you for the quick response, and this may be one way.

                                  However (sorry), I see a disadvantage, we use the case of sensors with the attribute door_sensor they are valid for access doors to the house, but are also for windows (first and second floor of the house, and the second floor is not turned on in night mode), and the same attribute has the internal door sensors, which in this case I use for air conditioning management (open door turns off the air).

                                  Another example would be the motion_sensor, I have internal and external sensors, in night mode the external ones turn on the garage and entrance lights, if I group everything by the attribute a movement inside the house would also trigger.

                                  This way your proposal is very valid, but there should be a way to dismember the groups, i.e. door_sensors_group1 (external door), door_sensors_group2 (window 1), door_sensor_group3 (internal door).... that's why I thought about the table that could specify each device and not use an attribute that generalizes the devices.

                                  This way your proposal is very valid, but there should be a way to dismember the groups, i.e. door_sensors_group1 (external door), door_sensors_group2 (window 1), door_sensor_group3 (internal door).... that's why I thought about the table that could specify each device and not use an attribute that generalizes the devices.

                                  I don't know if there could be something in these instructions referring to the global object we commented on DeviceList.

                                  door_sensors: include_capability: door_sensor %(#ff0000)[contained in DeviceList = "Door External".]

                                  or would it be something in this instruction

                                  door_sensors_tripped: include_group: door_sensors, filter_expr: entity.attributes.door_sensor.state %(#ff0000)[contained in DeviceList = "Door External".]

                                  (please don't laugh at my coding, I said I don't know it))

                                  The excellent thing is that we are going to take more automatic paths as you are commenting.

                                  Despite not wanting to depend on a hub, I looked at the HSM option, I see that it would be possible to create the groups I have commented, now I did not understand your comment that the MSR would talk to the HSM.

                                  In HSM the actions I see are alert by text, audio, siren or light. The way, in this case, would be to create a virtual device connected with HSM, and this one the MSR would monitor to take action?

                                  In the Apps that I set up the MSR, I don't see the option to select on device the action I created in the HSM. I have the option Allow control of HSM activated. Do I have to configure anything to show up on the MSR?

                                  Fact that I will not make Hubitat take action, who performs action in my solution is the MSR.

                                  toggledbitsT Offline
                                  toggledbitsT Offline
                                  toggledbits
                                  wrote on last edited by
                                  #27

                                  @wmarcolin said in Multidimensional Array:

                                  I don't know if there could be something in these instructions referring to the global object we commented on DeviceList.
                                  door_sensors: include_capability: door_sensor contained in DeviceList = "Door External".

                                  No, you can't refer to global variables in a group filter expression.

                                  Make as many groups as you need/want.

                                  @wmarcolin said in Multidimensional Array:

                                  In the Apps that I set up the MSR, I don't see the option to select on device the action I created in the HSM. I have the option Allow control of HSM activated. Do I have to configure anything to show up on the MSR?

                                  Find the entity called "Safety Monitor" in the Entities list (hint: use the filters; it will come from your Hubitat controller, and it will have capability x_hubitat_hsm, as well as that very distinct name, so lots of ways to find it).

                                  Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                  wmarcolinW 1 Reply Last reply
                                  0
                                  • toggledbitsT toggledbits

                                    @wmarcolin said in Multidimensional Array:

                                    I don't know if there could be something in these instructions referring to the global object we commented on DeviceList.
                                    door_sensors: include_capability: door_sensor contained in DeviceList = "Door External".

                                    No, you can't refer to global variables in a group filter expression.

                                    Make as many groups as you need/want.

                                    @wmarcolin said in Multidimensional Array:

                                    In the Apps that I set up the MSR, I don't see the option to select on device the action I created in the HSM. I have the option Allow control of HSM activated. Do I have to configure anything to show up on the MSR?

                                    Find the entity called "Safety Monitor" in the Entities list (hint: use the filters; it will come from your Hubitat controller, and it will have capability x_hubitat_hsm, as well as that very distinct name, so lots of ways to find it).

                                    wmarcolinW Offline
                                    wmarcolinW Offline
                                    wmarcolin
                                    wrote on last edited by
                                    #28

                                    @toggledbits

                                    Well, you put me to think a lot, I'm reviewing all the logic and I think progressing. You could have a video lesson on Creating Automations > Expressions 🙂 I am looking to meet this with trial and error. I just tested this on Groups and it worked perfectly, it will help:

                                        "internal_move":
                                          name: Internal Move Devices
                                          select:
                                            - include_entity: 
                                              - "vera>device_1679"
                                              - "vera>device_1683"
                                              - "vera>device_1797"
                                              - "hubitat>1"
                                              - "hubitat>14"
                                          filter_expression: > 
                                            entity.attributes?.motion_sensor?.state == true
                                    

                                    Now from your last comment about the MSR visualizing the HSM, I really don't know what I have to do, the Safe Monitor you commented appears, but it is all Disarmed.

                                    c5e7919e-b0a8-4cda-ab8b-3732df49463c-image.png

                                    But in the HSM in the hub the rules are created, activated, and even with action alert activated.

                                    759e9d15-f591-4ec6-87dc-d5e40bbe5810-image.png

                                    Any recommendations on what I should do?

                                    Thanks,

                                    1 Reply Last reply
                                    0
                                    • toggledbitsT toggledbits locked this topic on
                                    Reply
                                    • Reply as topic
                                    Log in to reply
                                    • Oldest to Newest
                                    • Newest to Oldest
                                    • Most Votes


                                    Recent Topics

                                    • Reactor (Multi-System/Multi-Hub) Announcements
                                      toggledbitsT
                                      toggledbits
                                      5
                                      121
                                      35.1k

                                    • Limit HA Entity in MSR
                                      toggledbitsT
                                      toggledbits
                                      0
                                      2
                                      11

                                    • Disaster recovery and virtualisation
                                      CatmanV2C
                                      CatmanV2
                                      0
                                      5
                                      577

                                    • Remote access of Zwave stick from Z-wave server
                                      CatmanV2C
                                      CatmanV2
                                      0
                                      3
                                      301

                                    • Organizing/ structuring rule sets and rules
                                      G
                                      gwp1
                                      0
                                      5
                                      348

                                    • Moving MSR from a QNAP container to RP 5 - some issues
                                      G
                                      gwp1
                                      0
                                      5
                                      293

                                    • Widget deletion does not work and landing page (status) is empy
                                      G
                                      gwp1
                                      0
                                      4
                                      264

                                    • Need help reducing false positive notifications
                                      T
                                      tamorgen
                                      0
                                      7
                                      460

                                    • Deleting widgets
                                      toggledbitsT
                                      toggledbits
                                      0
                                      4
                                      440

                                    • MQTT configuration question
                                      tunnusT
                                      tunnus
                                      0
                                      11
                                      592
                                    Powered by NodeBB | Contributors
                                    Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                    • Login

                                    • Don't have an account? Register

                                    • Login or register to search.
                                    • First post
                                      Last post
                                    0
                                    • Categories
                                    • Recent
                                    • Tags
                                    • Popular
                                    • Unsolved