I have the following yaml configuration in local_mqtt_devices file
x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }'While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Hi!
I get this message when I'm on the status tab:
System Configuration Check
The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds.
I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6.
HA versions are:
Core 2025.3.4
Supervisor 2025.03.4
Operating System 15.1
I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version.
Do anyone know what I can try?
Thanks in advance!
Let's Be Careful Out There (Hill Street reference...) 🙂
/Fanan
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB.
While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed.
So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response.
While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits
Thanks!
Hi ,
I'm on
-Reactor (Multi-hub) latest-25067-62e21a2d
-Docker on Synology NAS
-ZWaveJSUI 9.31.0.6c80945
Problem with ZwaveJSUI:
When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white.
I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui.
I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb".
After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color.
This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite.
x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33}The "cold white" and "warm white" settings interfer with the rgb color settings.
Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white
are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white.
So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have
x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColorIn zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set.
x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this?
x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33}Thanks in advance.
Good day all,
I have a reaction set up, that I use for both troubleshooting and changing home modes when one of my family members either arrive or are leaving. I use the companion app for HAAS on our iPhones, and HAAS reports if the person associated with the iPhone enters or leaves the geofenced area around my home. I'm sure most MSR and HAAS users are familiar with this.
I use this rule set mainly as a condition for other rules, however, as part of troubleshooting, a notification is sent through HAAS to the companion app when the rule becomes true. The problem is that I'm getting notifications now for both arriving and departing simultaneously.
96b3f7db-ba09-499e-a78c-86903b603857-image.png
36903cdd-a87f-473b-82ef-af9ef96d3c44-image.png It used to work fine as intended. I'm not sure exactly when it changed, but now I'm getting two notifications when either of these conditions change.
Any idea what could be happening?
Edit:
Running: latest-25082-3c348de6, bare-metal Linux
ZWaveJSControllerr [0.1.25082]
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem?
I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.
Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.Similarly as for local expressions, global expressions evaluate and update fine when getEntity(...) structure is used. However, at least when certain functions are in use, expressions do not update.
Consider the following test case:
Screenshot 2025-03-13 at 16.29.42.png
Even though auto-evaluation is active, value does not change (it changes only if that expression is manually run). MSR restarts do not help.
Screenshot 2025-03-13 at 16.31.43.png
Note: Tested using build 25067 on Docker. I have also a PR open (but couldn't now get details or PR number as my Mantis account was somehow expired?).
Trying to understand what cause a local expresssion to be evaluated. I have read the manual but I am still not clear about it. Using the test rule below, I can see in the log that the rule is being automatically evaluated every time the temperature entity is changing. That is great...
What I am trying to understand is why the expression is not evaluated based on time as well since the "case" statement has time dependencies.
Any help would be appreciated
I have the following test rule:
eba6a3ea-ff61-4610-88c9-9b9864f11ff8-Screenshot 2025-01-21 095244.png
2d9c1ff5-7b73-4005-b324-9029c2709db9-Screenshot 2025-01-21 095302.png
Here is the expressioncode:
vFrom1 = "09:25:00", vFrom2 = "09:30:00", vFrom3 = "09:41:00", vTo = "10:55:00", # Get current time (format HH:MM:SS) vToDay = strftime("%H:%M:%S"), #Get current house temperature CurrentHouseTemp = getEntity( "hass>Thermostat2 " ).attributes.temperature_sensor.value, case when CurrentHouseTemp <= 19 and vToDay >= vFrom1 && vToDay <= vTo: "true1" # From1 when CurrentHouseTemp <= 20 and vToDay >= vFrom2 && vToDay <= vTo: "true2" # From2 when CurrentHouseTemp < 26 and vToDay >= vFrom3 && vToDay <= vTo: "true3" # From3 else "false" endI am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved.
The Runtime Error is different in the two browsers
Safari v18.3
Google Chrome 133.0.6943.142
TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.Steps to reproduce:
Click the pencil to edit a global reaction with a group.
Click the Exit button.
Runtime error appears.
or
Click Create Reaction
Click Add Action
Select Group
Add Condition such as Entity Attribute.
Add an Action.
Click Save
Click Exit
Runtime error appears.
I don’t know how long the error has been there as I haven’t edited the global reaction in a long time.
Reactor (Multi-hub) latest-25060-f32eaa46
Docker
Mac OS: 15.3.1
Thanks
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons.
I have not created a global expression for some times and just noticed this while doing some clean-up.
I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success.
Here's what the log shows.
[latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" }Reactor latest-25067-62e21a2d
Docker on Synology NAS
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method.
This was prompted by yesterday's fun and games with my ISP.
I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone)
I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions?
TIA
C
Hi,
I'm trying to integrate the sonos-mqtt (https://sonos2mqtt.svrooij.io/) with the MSR and it's coming along nicely so far.
But cannot wrap my head around how to define custom capabilities in MQTT templates. I need this for the TTS announcements and similarly for the notification sounds where I would pass the sound file as parameter.
So this is what I have in the local_mqtt_devices.yaml
capabilities: x_sonos_announcement: attributes: actions: speak: arguments: text: type: string volume: type: int delay: type: intAnd this is the template:
templates: sonos-announcement: capabilities: - x_sonos_announcement actions: x_sonos_announcement: speak: topic: "sonos/cmd/speak" payload: expr: > { "text": parameters.text, "volume": parameters.volume, "delayMs": parameters.delay, "onlyWhenPlaying": false, "engine": "neural" } type: jsonSo the speak action should send something like this to topic sonos/cmd/speak
{ "text": "message goes here", "volume": 50, "delayMs": 100, "onlyWhenPlaying": false, "engine": "neural" }At startup the MSR seems to be quite unhappy with my configuration:
reactor | [latest-25016]2025-02-09T08:19:59.029Z <MQTTController:WARN> MQTTController#mqtt entity Entity#mqtt>sonos-announcement unable to configure capabilities [Array][ "x_sonos_announcement" ] reactor | i18n: missing fi-FI language string: Configuration for {0:q} is incomplete because the following requested capabilities are undefined: {1} reactor | i18n: missing fi-FI language string: Configuration for {0:q} has unrecognized capability {1:q} in actions reactor | Trace: Configuration for {0:q} is incomplete because the following requested capabilities are undefined: {1} reactor | at _T (/opt/reactor/server/lib/i18n.js:611:28) reactor | at AlertManager.addAlert (/opt/reactor/server/lib/AlertManager.js:125:25) reactor | at MQTTController.sendWarning (/opt/reactor/server/lib/Controller.js:627:30) reactor | at MQTTController.start (/var/reactor/ext/MQTTController/MQTTController.js:268:26) reactor | at async Promise.allSettled (index 0) Configuration for "sonos-announcement" has unrecognized capability "x_sonos_announcement" in actions Controller: MQTTController#mqtt Last 10:21:37 AM Configuration for "sonos-announcement" is incomplete because the following requested capabilities are undefined: x_sonos_announcement Controller: MQTTController#mqtt Last 10:21:37 AMThis is probably a pretty stupid question and the approach may not even work at all, but maybe someone or @toggledbits for sure, could point me to the right direction.
Basically the idea is to be able to send TTS messages from reactions using entity actions. I've previously used HTTP requests to Sonos HTTP API (https://hub.docker.com/r/chrisns/docker-node-sonos-http-api/) for the same functionality, but since moving to sonos-mqtt, I need a way to send the TTS notifications using MQTTController. Along with the actual message, volume and delay must also be parameterizable.
br,
mgvra
MSR latest-25016-d47fea38 / MQTTController [0.2.24293]
Hi, @toggledbits
I just noticed that following a reboot of my raspberry pi, some of the rules, that I was expecting to recover, are not catching up following a reboot. I have made a simple test rule (rule-m6rz6ol1) with only "after Date/time" as trigger and "turn on a lamp" as a set reaction. All my infrastructure is on the same board so Reactor, Hass, Zwavejs, ... are all rebooting.
Here is the sequence of the test case (All time converted to Zulu to match logs):
Rule "after Date/Time" set to 14:05:00z Shutdown on Raspberry Pi at 14:04:00z Power back up at 14:08:00z Rule overview shows true as of 14:08:14z waiting for 00:00:00 in GUIFrom the log I can see that MSR is picking up the rule and knows that the state of the rule has changed from false to true and tries to send the update to HASS but failed with websocket error.
Here is what I see from the log:
14:04:04z shutdown complete 14:08:08z Power up 14:08:13.111z websocket connection 14:08:15:323z Reaction to the light failed, Websocket not opened After there is a series of websocket connection attempt until 14:08:51z where it seemed to be really ready.Back in 2021 we had a discussion (https://smarthome.community/topic/700/solved-start-up?_=1738766986566) and you proposed to add a startup_delay:xxxx and startup_wait:xxxx parameter in the engine section of "reactor.yaml". When I try the startup_delay (this used to be a hard delay), the engine failed to start (I think). I then try the startup_wait:xxxx without any success. Since it wait for the connection status to be up to cancel the delay, it does not do anyting since Hass is reporting the socket up without really being up ( I think...).
Questions:
Did I figured it all wrong? should the startup_delay:xxxxx have worked? Any ideas?Here is the log:
OK now I am stuck. I did add the log but when I submit the editor complained saying that I am limited to 32767 characters. The log from the shutdown to the time the websocket is stable is about 300000 character long. What are my options?
Not a big issue simply a request if easily doable.
The MSR logs files inside the container are owned by root witch is fine however, the permissions are very restrictive. I do not know if there is something wrong with my installation but the logs permission are set to 222 (write only). Even if the docker volume is set for Read/Write the log files are retaining these values.
I go around the problem by doing a chmod 777 on all reactor logs but every time there is an MSR log rotation the permissions are set back to 222. So unless the permission are implemented in the container there is no permanent solution to this (that I know of).
I do not know much about Docker container so I do not know what is involved here.
Can the logfiles permission be simply chaged in the container to at least allow "other" read permission?
Could the MSR log rotation routine implement a chmod to set the permission?
Just a small anoyance
Thanks
@toggledbits In the MSR documentation, under Standard Capabilities, I noticed that the
button.since attribute was deprecated as of version 22256 and the metadata is the preferred way to access the last-modified time of an attribute.
Am I reading this right? Should I stop using it in my rules?
Thanks
When on my bare metal RPi with MSR I had a rule that ran every minute to check Internet status via a script in MSR called reactor_inet_check.sh
I've moved to containerized MSR and see in the instructions that this cannot be run from the container.
The script cannot run within the Reactor docker container. If you are using Reactor in a docker container, the script needs to be run by cron or an equivalent facility on the host system (e.g. some systems, like Synology NAS, have separate task managers that may be used to schedule the repeated execution of tasks such as this).
I've put a script on my container host that calls the reator_inet_check.sh script and it isn't erroring... but I still see the internet status within MSR as null.
Before I go diving down the rabbit hole... should this work?
My cronjob on the proxmox host:
909fe6f0-77fd-4734-80a4-c9e354c910b6-image.png
The contents of msr_internet_check_caller.sh
16337528-cf31-4968-bffe-af1149f7103e-image.png
Background: this is a Windows MSR install I've done for our local pool/amenity center just to run some fans and lights (not my daily driver at home). Install went perfectly fine.
Scenario: I want the lights to go on when it's dark enough (even if during a storm, not just after sunset) so I'm using solarRadiation from my weather station to drive that Trigger. Easy stuff.
Issue: sometimes, someone goes in the office and just starts flipping switches and the result can be lights turned on in the daytime or off at night. I'm trying to create a "catch-all" wherein if it is daytime and the lights somehow find their way ON, they will turn themselves back OFF.
I have the following Reaction built:
b30eab5b-5a14-4a3a-8c9a-47e3e7e53dc3-image.png
I also have this Reaction for opposite, ie the lights find themselves turned off after dark and they will turn themselves back on:
5c6946b1-297c-4eb1-9618-74820979df29-image.png
Here are my two rules:
288cba86-f941-4157-86d9-d8e7487905f7-image.png *NOTE that in my manual testing, ie I turn on the light switch at the incorrect time, when the solarRadiation level changes the Lights ON rule flags and shows as SET. On the next change of solarRadiation it goes back to reset again.
My expectation is that Lights OFF rule should see the lights are on, the solarRadiation is above the set limit, and turn them off. Instead, every other run, the ON rule moves to SET and then reset again on the following run.
Logs appear angry:
[latest-25016]2025-01-26T22:03:31.696Z <Engine:INFO> Enqueueing "Lights ON<RESET>" (rule-m6e4ajh7:R) [latest-25016]2025-01-26T22:03:31.712Z <Engine:NOTICE> Starting reaction Lights ON<RESET> (rule-m6e4ajh7:R) [latest-25016]2025-01-26T22:03:31.713Z <Engine:INFO> Lights ON<RESET> all actions completed. [latest-25016]2025-01-26T22:03:42.565Z <wsapi:INFO> client "127.0.0.1#3" closed, code=1001, reason= [latest-25016]2025-01-26T22:03:42.753Z <httpapi:INFO> [HTTPAPI]#1 API request from ::ffff:127.0.0.1: GET /api/v1/lang [latest-25016]2025-01-26T22:03:42.754Z <httpapi:INFO> [HTTPAPI]#1 request for /api/v1/lang from ::ffff:127.0.0.1 user anonymous auth none matches /api/v1/lang ACL (#7): [Object]{ "url": "/api/v1/lang", "allow": true, "index": 7 } [latest-25016]2025-01-26T22:03:42.790Z <wsapi:INFO> wsapi: connection from ::ffff:127.0.0.1 [latest-25016]2025-01-26T22:03:42.839Z <wsapi:INFO> [WSAPI]wsapi#1 client "127.0.0.1#6" authorized [latest-25016]2025-01-26T22:03:43.353Z <httpapi:INFO> [HTTPAPI]#1 API request from ::ffff:127.0.0.1: GET /api/v1/systime [latest-25016]2025-01-26T22:03:43.353Z <httpapi:INFO> [HTTPAPI]#1 request for /api/v1/systime from ::ffff:127.0.0.1 user anonymous auth none matches /api/v1/systime ACL (#5): [Object]{ "url": "/api/v1/systime", "allow": true, "index": 5 } [latest-25016]2025-01-26T22:03:48.146Z <wsapi:INFO> client "127.0.0.1#6" closed, code=1001, reason= [latest-25016]2025-01-26T22:03:48.308Z <httpapi:INFO> [HTTPAPI]#1 API request from ::ffff:127.0.0.1: GET /api/v1/lang [latest-25016]2025-01-26T22:03:48.309Z <httpapi:INFO> [HTTPAPI]#1 request for /api/v1/lang from ::ffff:127.0.0.1 user anonymous auth none matches /api/v1/lang ACL (#7): [Object]{ "url": "/api/v1/lang", "allow": true, "index": 7 } [latest-25016]2025-01-26T22:03:48.346Z <wsapi:INFO> wsapi: connection from ::ffff:127.0.0.1 [latest-25016]2025-01-26T22:03:48.390Z <wsapi:INFO> [WSAPI]wsapi#1 client "127.0.0.1#7" authorized [latest-25016]2025-01-26T22:03:49.412Z <httpapi:INFO> [HTTPAPI]#1 API request from ::ffff:127.0.0.1: GET /api/v1/systime [latest-25016]2025-01-26T22:03:49.413Z <httpapi:INFO> [HTTPAPI]#1 request for /api/v1/systime from ::ffff:127.0.0.1 user anonymous auth none matches /api/v1/systime ACL (#5): [Object]{ "url": "/api/v1/systime", "allow": true, "index": 5 } [latest-25016]2025-01-26T22:03:52.734Z <wsapi:INFO> client "127.0.0.1#7" closed, code=1001, reason= [latest-25016]2025-01-26T22:03:52.891Z <httpapi:INFO> [HTTPAPI]#1 API request from ::ffff:127.0.0.1: GET /api/v1/lang [latest-25016]2025-01-26T22:03:52.892Z <httpapi:INFO> [HTTPAPI]#1 request for /api/v1/lang from ::ffff:127.0.0.1 user anonymous auth none matches /api/v1/lang ACL (#7): [Object]{ "url": "/api/v1/lang", "allow": true, "index": 7 } [latest-25016]2025-01-26T22:03:52.925Z <wsapi:INFO> wsapi: connection from ::ffff:127.0.0.1 [latest-25016]2025-01-26T22:03:52.965Z <wsapi:INFO> [WSAPI]wsapi#1 client "127.0.0.1#8" authorized [latest-25016]2025-01-26T22:03:54.383Z <httpapi:INFO> [HTTPAPI]#1 API request from ::ffff:127.0.0.1: GET /api/v1/systime [latest-25016]2025-01-26T22:03:54.384Z <httpapi:INFO> [HTTPAPI]#1 request for /api/v1/systime from ::ffff:127.0.0.1 user anonymous auth none matches /api/v1/systime ACL (#5): [Object]{ "url": "/api/v1/systime", "allow": true, "index": 5 } [latest-25016]2025-01-26T22:04:01.590Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25016]2025-01-26T22:04:39.646Z <Rule:INFO> Lights OFF (rule-m6e33ja3 in Atrium Lights) evaluated; rule state transition from RESET to SET! [latest-25016]2025-01-26T22:04:39.656Z <Rule:INFO> Lights ON (rule-m6e4ajh7 in Atrium Lights) evaluated; rule state transition from RESET to SET! [latest-25016]2025-01-26T22:04:39.663Z <Engine:INFO> Enqueueing "Lights OFF<SET>" (rule-m6e33ja3:S) [latest-25016]2025-01-26T22:04:39.665Z <Engine:INFO> Enqueueing "Lights ON<SET>" (rule-m6e4ajh7:S) [latest-25016]2025-01-26T22:04:39.668Z <Engine:NOTICE> Starting reaction Lights OFF<SET> (rule-m6e33ja3:S) [latest-25016]2025-01-26T22:04:39.669Z <Engine:NOTICE> Starting reaction Lights ON<SET> (rule-m6e4ajh7:S) [latest-25016]2025-01-26T22:04:39.669Z <Engine:INFO> Lights ON<SET> all actions completed. [latest-25016]2025-01-26T22:04:39.675Z <Rule:INFO> Lights OFF (rule-m6e33ja3 in Atrium Lights) evaluated; rule state transition from SET to RESET! [latest-25016]2025-01-26T22:04:39.680Z <Engine:NOTICE> ReactionHistory: no entry for [latest-25016]2025-01-26T22:04:39.683Z <Engine:NOTICE> [Engine]Engine#1 entry 256 reaction rule-m6e33ja3:S-1q2f1j0p: [Error] terminated [parent terminating] [latest-25016]2025-01-26T22:04:39.683Z <Engine:CRIT> Error: terminated [parent terminating] Error: terminated at Engine._process_reaction_queue (C:\Users\Jalan\msr\reactor\server\lib\Engine.js:1644:47) [latest-25016]2025-01-26T22:04:39.699Z <Engine:NOTICE> [Engine]Engine#1 entry 254 reaction rule-m6e33ja3:S: [Error] terminated [preempted by rule state change] [latest-25016]2025-01-26T22:04:39.699Z <Engine:CRIT> Error: terminated [preempted by rule state change] Error: terminated at Engine._process_reaction_queue (C:\Users\Jalan\msr\reactor\server\lib\Engine.js:1644:47) [latest-25016]2025-01-26T22:04:39.700Z <Engine:INFO> Enqueueing "Lights OFF<RESET>" (rule-m6e33ja3:R) [latest-25016]2025-01-26T22:04:39.704Z <Engine:NOTICE> Starting reaction Lights OFF<RESET> (rule-m6e33ja3:R) [latest-25016]2025-01-26T22:04:39.705Z <Engine:INFO> Lights OFF<RESET> all actions completed. [latest-25016]2025-01-26T22:05:48.822Z <Rule:INFO> Lights ON (rule-m6e4ajh7 in Atrium Lights) evaluated; rule state transition from SET to RESET! [latest-25016]2025-01-26T22:05:48.831Z <Engine:INFO> Enqueueing "Lights ON<RESET>" (rule-m6e4ajh7:R) [latest-25016]2025-01-26T22:05:48.847Z <Engine:NOTICE> Starting reaction Lights ON<RESET> (rule-m6e4ajh7:R) [latest-25016]2025-01-26T22:05:48.847Z <Engine:INFO> Lights ON<RESET> all actions completed.Hi @toggledbits
I found this very old post that talked about a way to limit device reading to avoid the throttled problem, because it's not a question of logic, it's that the device actually sends a lot of information, in my case the NUT ups installed in HE.
https://smarthome.community/topic/687/flapping-device?_=1737652139854
It mentions engine section of reactor.yaml by setting update_rate_limit, but I looked in the current MSR documentation and I can't find this information, so I don't know if it's still valid, its effect and parameters.
My situation is simple, when I have a UPS problem the NUT is sending dozens of reports per second and then I have the throttled problem. The same rule applies when the power is normal.
This is the rule, and the parameter that fails is the Tripp Lite UPS status.
cf9ddabf-3144-4e5a-80a4-0dc7664b9573-image.png
a813a077-974e-4737-897c-e383085b3d8f-image.png
All error is the same scenario.
[latest-25016]2025-01-23T12:01:32.753Z <Rule:WARN> (13) NUT Disconected (rule-l4djr0p7 in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Throttl> [latest-25016]2025-01-23T12:01:32.756Z <Rule:WARN> (27) Falta de Energia (rule-l4h9ceod in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Thrott> [latest-25016]2025-01-23T12:01:32.769Z <Rule:WARN> (73) UPS Battery Low (rule-l4hj850o in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Throttl> [latest-25016]2025-01-23T12:01:32.772Z <Rule:WARN> (74) UPS Comm Fail (rule-l4kbs5cp in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Throttlin> [latest-25016]2025-01-23T12:01:32.776Z <Rule:WARN> (76) UPS Utility Back (rule-l4hjhs6m in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Thrott> [latest-25016]2025-01-23T12:01:32.780Z <Rule:WARN> UPS On Battery (rule-l4hjuka5 in Datacenter) update rate 121/min exceeds limit (120/min)! Logic loop? Throttling> [latest-25016]2025-01-23T12:01:32.781Z <Rule:WARN> UPS Info (rule-l4gheo63 in Datacenter) update rate 121/min exceeds limit (120/min)! Logic loop? Throttling... [latest-25016]2025-01-23T12:01:40.757Z <Rule:WARN> (13) NUT Disconected (rule-l4djr0p7 in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Throttl> [latest-25016]2025-01-23T12:01:40.759Z <Rule:WARN> (27) Falta de Energia (rule-l4h9ceod in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Thrott> [latest-25016]2025-01-23T12:01:40.776Z <Rule:WARN> (73) UPS Battery Low (rule-l4hj850o in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Throttl> [latest-25016]2025-01-23T12:01:40.777Z <Rule:WARN> (74) UPS Comm Fail (rule-l4kbs5cp in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Throttlin> [latest-25016]2025-01-23T12:01:40.778Z <Rule:WARN> (76) UPS Utility Back (rule-l4hjhs6m in Warning) update rate 121/min exceeds limit (120/min)! Logic loop? Thrott>Thanks.
Hello -
Long time. Hope everyone is good.
I have a rule that looks at a number of temperature sensors around the house. It simply sends a general alert if any of them fall below their threshold. (A basic “House is too cold” alert for when we’re away)
Generally, this has worked well. But I was wondering if there’s a way to make the message somewhat dynamic without creating separate rules for each sensor.
E.g. “House is too cold due to Sump Temperature below 45 degrees.”
I thought I remember reading about someone doing this in the past but couldn’t find it.
Thanks for any ideas!
Multidimensional Array
-
${{[["Window 1","Status On"],["Window 2","Status On"],["Window 3","Status Off"],["Window 4","Status On"]]}}
should work
and to find all Status on'seach val in testarray : if val[1] === "Status On" then val[0] endif
and to find the value of Window 1
(each val in testarray : if val[0] === "Window 1" then val[1] endif)[0]
-
Expanding the question, suppose the first part of the array is the device ID, like "vera>device1234".
Is it possible to use the function below to use this same bidirectional array to search for the name, i.e. using val[0] for the search?
sort( each id in testarray: do e=getEntity( id ), ( e?.attributes?.binary_sensor?.state == true or e?.attributes?.motion_sensor?.state == true ) ? e.name : null done )
What would the function look like?
Thanks.
-
@wmarcolin I smell an X-Y problem, but I'll go on...
I don't know what "bidirectionally" means in this context. Do you mean "two dimensional?" Bidirectional refers to movement, for example, forwards and backwards, or up and down, which is a different thing.
A couple of minor comments to @Elcid 's response:
${{[["Window 1","Status On"],["Window 2","Status On"],["Window 3","Status Off"],["Window 4","Status On"]]}}
Note that this is substitution syntax, not expression syntax when defining a variable. Adjust accordingly.
each val in testarray : if val[1] === "Status On" then val[0] endif
There is no
===
operator in the expression language, it's just==
(each val in testarray : if val[0] === "Window 1" then val[1] endif)[0]
This is better written as
first ... of ...
, since you only want the one element (which by implication here the key "Window 1" must be unique in the array), and there's no need to keep searching through the array once you've found it (wastes CPU cycles).But about that uniqueness for "Window 1"... this is the real meat of my response:
If the first element of each subarray (row) is unique, then using a two-dimensional array is inefficient (i.e. doable, but not the best choice). Where unique values are present, an object containing key/value pairs gives immediate random access to any "element", without iteration:
devices = { "lamp1": "on", "lamp2": "off", "lamp3": "on" }
In this example, we can quickly determine the status of any lamp without iteration:
devices.lamp2
will give usoff
.This can be further broken down with additional data: each value in the key/value pairs of the object can be any data type, so they can be an array or object themselves:
devices = { "lamp1": { "status": "on", "room": 0 } "lamp2": { "status": "off", "room": 0 } "lamp3": { "status": "on", "room": 2 } }
We can again quickly get to the state of lamp2 using
devices.lamp2.status
(resultoff
again). Usingdevices.lamp3.room
tells us that lamp3 is in room 2. Note that in the example code above, I have shown lamp1 with a typical (JSON-style) fully indented with line breaks for readability, but lamp2 and lamp3 are in a more compact form. Whitespace (including newlines) are not significant to the syntax. Use them for readability if you wish, or leave them out for compactness if that's acceptable.When you must search within the values, you can still use iteration. Find the devices in room 0:
each dev,id in devices: dev.room==0 ? id : null
By using
each dev,id
, the iterator will provide both the value and the key for each pair in the object. That is, on the first iteration, dev will contain our subobject (itself with keys status and room) for lamp1, and id will containlamp1
; on the second iteration, the subobject for lamp2 is given in dev, and id islamp2
, and so on. The result of the iteration in this case is an array of IDs of objects in room 0:["lamp1","lamp2"]
; you could also modify the iteration to return the data objects (using dev), if that was more efficient for your later use of this expression's result.Find the first device that is "off":
first dev,id of devices: dev.status=="off" ? id : null
Adding new devices after the initialization is also easy:
devices.lamp4 = { "status": "on", "room": 2 }
But this is all data storage theory, and details of an implementation for a problem that apparently hasn't been stated. We need to know what you are really trying to do, if you are asking for help getting it done. As I said, where we stand right now, this seems very X-Y-ish. The post title is also poor quality, and the head post itself breaks a couple of the posting guidelines.
-
Hi Patrick!
%(#ff0000)[Again a Master Class on how to do the right things.]
My use case is that I want to associate each device in my installation with an identification of which group it belongs to (door, window, security, light...).
The group I will have to make the manual list (I think), so the first step of var1, I understand is the list I have to assemble, and whenever I have a new device, I update this list manually.
Just a note master, at the beginning of your example, I had to put the comma at each element of the array
I reproduced your examples to test, and I just can't find the error in the example of the first (var4).
Now comes the use, to see device names and which group they are in, or even to search the groups. My next step, is to manage when a device has the true state of its sensor, to take actions such as triggering an action/alarm/siren/message according to the group the device is part of.
If you can see, I am looking to work around not using (yet) a database, which we have had in other trackers to empower the information from the devices.
Now exploring the Master, sorry
In your last example, you explain how to add one more row to the array, one more element, perfect. Now, is it possible to add another column to the existing array? For example, with the array I created, add a column that already stores the device name? A loop that looks at the devid and then looks at the device name attribute?
I was forgetting, how do I change the contents of the array, is it possible with Set Variable? I want to change for example the group from DevWindow to DevDoor for one element.
Thanks.
-
@wmarcolin Well, I'm almost ready to release my first version of dynamic groups... still hashing out a few details. If you urgently need to do all this work, it's certainly a good opportunity to break your forehead on some sticky problems (I'm always in favor of experimentation and pushing limits).
First, having
var1
be an expression that does an assignment todevices
isn't necessary. Just call your variable devices and put in the rest of the expression after the=
in your screen shot and be done with it. You can also set up yourdevices
structure more simply. I'm not sure what the extradev001
anddev002
identifiers are doing for you, but you can (and probably should) just use the entity canonical IDs directly. It will make everything much simpler. Here's is the expression for thedevices
variable:{ "hubitat>15": { group: "DevWindow" }, "vera>device_1866": { group: "DevDoor" }, ...etc... }
Also, if
group
is the only data you are keeping, there is no value to creating a subobject to keep it, just make the group name be the value of the device's key/ID. But I'll continue with the structure you're trying to use...Anyway, by simplifying the structure of
devices
, here's what it looks like and how it changes your first three expressions:Looking at var2, we need to use quoted identifiers because a canonical ID contains a character (
>
) that cannot be used in an identifier, so thisdevices.hubitat>15.group
is not valid. The quoted identifier syntax iscontext["complexKey"]
as shown.The var3 expression is simpler, because we're not looking through the extra layer of indirection your structure had introduced, we're looking directly as our descriptive subobjects.
The var4 expression is an error in the syntax on my part. The correct syntax is shown, but I've had to embellish a bit here (next release of Reactor for you, so it won't work until I publish and you update).
But here's the important part...
As for the rest of it, you're making it unnecessarily hard, I think, because
entity.primary_value
will give you the value of the primary attribute, so you don't really need to care what capability that comes from and go to the work of classifying devices in expressions to try to make that work. There's an easier way.Based on what I see here, now that we understand you are actually trying to accomplish, what you really need to do is set those primary attributes in
local_hubitat_devices.yaml
, and skip all of thedevices
complexity you are creating here, and just use theprimary_value
from the entity in your sort/search expressions.To do the overrides in
local_hubitat_devices.yaml
:entities: # Entry shows how an entity can have a service added and its name forced "hubitat>76": # Name override name: "Attic Environmental Sensor" # # List of capabilities to add to this device (array) capabilities: - SomeAdditionalCapability - AnotherAdditionalCapability # # Assign primary attribute for this device primary_attribute: "temperature_sensor.value" "hubitat>178": primary_attribute: "x_hubitat_extra_attributes.batteryLastReplaced"
-
Hi Master!
Wow, good news that we will have in the MSR capacity, I am your test guy if you need a tester. And I'm aligned with you, I like to explore, learn, go to the limit, even with knowledge limitations, I seek to explore.
I will keep the array structure that can put more dimensions, surely I will explore.
Aligned from var4, I repeated your instruction and it really follows the syntax error, no problem for now, as I said we are learning and testing.
Master I am trying, to follow the correct path, instead of going all the way around creating the array. I edited the file local_hubitat_devices.yaml to test with these 4 devices, and I see that in the capabilities now appears the DeviceGroup, but I don't see in the attributes, or way to add the value.
# This file has local definitions/overrides for Hubitat devices. --- entities: # Entry shows how an entity can have a capability added and its name forced "hubitat>NNN": # Name override #name: "Attic Environmental Sensor" # # List of capabilities to add to this device (array) #capabilities: # - Tone # # Assign primary attribute for this device #primary_attribute: "temperature_sensor.value" "hubitat>15": capabilities: - DeviceGroup group: "Window" "hubitat>67": capabilities: - DeviceGroup group: "Window" "hubitat>98": capabilities: - DeviceGroup group: "Door" "hubitat>99": capabilities: - DeviceGroup group: "Door"
Now I have a question, can I use this same file for the Vera devices? Following the same path?
Thanks.
-
You can't make up data. Just because you assign the capability DeviceGroup to the device, that doesn't mean you get to assign the attributes (group) that may be associated with that capability. Hubitat would have to provide the group data from its side -- the values for that attribute still have to come from Hubitat. And that probably won't be happening, because DeviceGroup does not appear to be a valid Hubitat capability.
-
@toggledbits I understand, so in this case for now is to use the array resource that we discussed before, until you publish the news.
Anyway thanks for one more class of knowledge.
-
@toggledbits said in Multidimensional Array:
There is no === operator in the expression language, it's just ==
Also used in a test expression and working.
Noted used "in" rather than "of" as I thought he wanted a 2D array not a object/dictionary.
-
@elcid said in Multidimensional Array:
Not according to your doc's.
You are correct, I'm suffering from holiday brain-fade.
@wmarcolin Version 21331 just released has the first release of dynamic groups. It also includes a syntax enhancement to the expression
first...in
statement to allow a result expression, so it can return something other than what it finds (i.e. it can perform operations on what it finds and return that as a result). This is useful for yourvar4
of this post, which should befirst dev,id of devices: dev.group=="DevDoor": id
to give you the ID of the first matching device. But again, I think the combination of primary attribute assignment and dynamic groups is going to be the best way to solve this. -
@toggledbits Hi!
Perfect, you have totally changed the command.
first dev,id in var1 with dev.group=="DevDoor": dev.devid
I'm going to study the dynamic group, because even though I can compare object or array contents, the usage is horrible. It's very difficult to validate an array inside another one, or to make combined selections.
Well, I don't really know the language, so I'm having a hard time. Let's see if the dynamic groups can make something that should be simple easier.
I'll return tomorrow with my experiences
-
Hi Patrick!
I don't know if I'm doing something wrong, but I followed the following steps to use DynamicGroupController.- Stopped the MSR
- Compared the reactor configuration file
- Added the new Groups instruction, the one in the file is almost the same as the manual, and below is the one I set up.
- id: groups enable: true implementation: DynamicGroupController name: Dynamic Group Controller config: groups: "low_battery": name: Low Battery Devices select: - include_capability: - battery_power filter_expression: > entity.attributes.battery_power.level < 0.35 "tripped": name: Tripped Devices select: - include_capability: - binary_sensor - motion_sensor filter_expression: > entity.attributes.binary_sensor.state == true or entity.attributes.motion_sensor.state == true
- I restarted MSR + Tools Restart + Crtl+F5
- Search in Entities and I see that they are created, but without content
- Check if they are available for action, yes but also without content.
- As the master instructed, let's go to the log file.
[latest-21331]2021-11-27T21:13:45.136Z <default:INFO> OWMWeatherController#weather done; 1 locations, 0 failed [latest-21331]2021-11-27T21:13:45.137Z <default:NOTICE> Controller OWMWeatherController#weather is now online. [latest-21331]2021-11-27T21:13:46.538Z <VeraController:NOTICE> Controller VeraController#vera is now online. [latest-21331]2021-11-27T21:13:46.540Z <default:ERR> error updating dynamic group low_battery_entries: Error: Invalid selector key [latest-21331]2021-11-27T21:13:46.541Z <default:CRIT> Error: Invalid selector key Error: Invalid selector key at DynamicGroupController._select (C:\MSR\reactor\server\lib\DynamicGroupController.js:260:23) at DynamicGroupController._update_group (C:\MSR\reactor\server\lib\DynamicGroupController.js:193:45) at C:\MSR\reactor\server\lib\DynamicGroupController.js:243:38 at Array.forEach (<anonymous>) at DynamicGroupController._update (C:\MSR\reactor\server\lib\DynamicGroupController.js:240:95) at C:\MSR\reactor\server\lib\DynamicGroupController.js:150:42 at processTicksAndRejections (node:internal/process/task_queues:96:5) [latest-21331]2021-11-27T21:13:46.543Z <default:ERR> error updating dynamic group tripped_entries: Error: Invalid selector key [latest-21331]2021-11-27T21:13:46.544Z <default:CRIT> Error: Invalid selector key Error: Invalid selector key at DynamicGroupController._select (C:\MSR\reactor\server\lib\DynamicGroupController.js:260:23) at DynamicGroupController._update_group (C:\MSR\reactor\server\lib\DynamicGroupController.js:193:45) at C:\MSR\reactor\server\lib\DynamicGroupController.js:243:38 at Array.forEach (<anonymous>) at DynamicGroupController._update (C:\MSR\reactor\server\lib\DynamicGroupController.js:240:95) at C:\MSR\reactor\server\lib\DynamicGroupController.js:150:42 at processTicksAndRejections (node:internal/process/task_queues:96:5) [latest-21331]2021-11-27T21:13:46.544Z <app:NOTICE> Starting HTTP server and API... [latest-21331]2021-11-27T21:13:46.552Z <app:NOTICE> Starting Reaction Engine...
Well, I found this error, and obviously, I don't know how to solve it. What I did? I reinstalled the MSR, using only the config and storage directory, and the result is the same.
-
The groups would be empty if there were no tripped or low battery devices in their respective groups, so that's not all conclusive; it may be perfectly correct. The groups at least appear to be correct, for empty groups (no entities matched).
The time stamps in your log snippet are unrelated to the time stamp on the entities, so I can't really draw any conclusions from that either. If you post logs, make sure you are posting logs where the time stamps align to the problem you're reporting.
On your conditions, you can't compare an array to an empty string; that's not a valid test.
-
Ok let's go in parts, what I created in Group is the same thing I do in the traditional way and get the result, see the battery case.
I'm not seeing an error anymore, after a reboot of the MSR host.
[latest-21331]2021-11-28T02:45:18.584Z <default:null> Module httpapi v21308 [latest-21331]2021-11-28T02:45:18.661Z <VeraController:null> Module VeraController v21324 [latest-21331]2021-11-28T02:45:18.668Z <default:INFO> Structure#1 loading controller interface hubitat (HubitatController) [latest-21331]2021-11-28T02:45:18.676Z <HubitatController:null> Module HubitatController v21324 [latest-21331]2021-11-28T02:45:18.679Z <default:INFO> Structure#1 loading controller interface groups (DynamicGroupController) [latest-21331]2021-11-28T02:45:18.686Z <DynamicGroupController:null> Module DynamicGroupController v21331 [latest-21331]2021-11-28T02:45:18.688Z <default:INFO> Structure#1 loading controller interface weather (OWMWeatherController) [latest-21331]2021-11-28T02:45:18.693Z <OWMWeatherController:null> Module OWMWeatherController v21313
[latest-21331]2021-11-28T02:45:18.761Z <default:INFO> Starting controller HubitatController#hubitat [latest-21331]2021-11-28T02:45:18.782Z <default:INFO> Starting controller DynamicGroupController#groups [latest-21331]2021-11-28T02:45:18.784Z <default:NOTICE> Controller DynamicGroupController#groups is now online. [latest-21331]2021-11-28T02:45:18.785Z <default:INFO> Starting controller OWMWeatherController#weather
I see that the times are synchronized
But the array is still empty
Any instructions where I can look for something?
-
The recommended debugging for this would be to start unraveling your criteria and see what it produces. As a first step (don't do this, just read), I would remove the
filter_expression
and make sure that your selectors are producing the expected set of eligible devices. An easy way to do that is to simply put an "X" in front offilter_expression
(i.e. to make itXfilter_expression
), which changes the name of the key and hides it from the code that's looking for it. You could also comment it out, but that would require that you comment each subordinate line as well, which is more work and can be error-prone. Restart MSR after config changes, of course, and refreshes are also recommended (don't need to be hard refreshes).But, I found an error, and it's pretty subtle. For me, it logged one short line, so it would be easy to miss; I imagine you have it as well. But it's going to require a code change to fix, so I'll release another build later today. I'll also fix the doc issue you PM'd me about.
Also, don't forget that filtering by controller or capability is a good way to quickly remove "noise" from your Entities list.
-
I debugged removing filter_axpression entirely, and the variables are still empty. I'll wait for your version update and test again.
-
@toggledbits well done
Low Battery Devices charging perfect!
But there is a problem for "tripped", which repeated the same setting as "low_battery".
- id: groups enable: true implementation: DynamicGroupController name: Dynamic Group Controller config: groups: "low_battery": name: Low Battery Devices select: - include_capability: - battery_power filter_expression: > entity.attributes.battery_power.level < 0.3 "tripped": name: Tripped Devices select: - include_capability: - binary_sensor - motion_sensor filter_expression: > entity.attributes.binary_sensor.state == true or entity.attributes.motion_sensor.state == true
This is what is showing up in the log.
[latest-21332]2021-11-29T01:49:33.599Z <default:ERR> error updating dynamic group tripped: ReferenceError: Invalid reference to member state of null [latest-21332]2021-11-29T01:49:33.600Z <default:CRIT> ReferenceError: Invalid reference to member state of null ReferenceError: Invalid reference to member state of null at _run (C:\MSR\reactor\common\lexp.js:1369:31) at _run (C:\MSR\reactor\common\lexp.js:1233:34) at _run (C:\MSR\reactor\common\lexp.js:1290:44) at C:\MSR\reactor\common\lexp.js:1223:29 at Array.forEach (<anonymous>) at _run (C:\MSR\reactor\common\lexp.js:1222:28) at Object.run (C:\MSR\reactor\common\lexp.js:1564:22) at DynamicGroupController._update_group (C:\MSR\reactor\server\lib\DynamicGroupController.js:229:141) at C:\MSR\reactor\server\lib\DynamicGroupController.js:267:39 at Array.forEach (<anonymous>)
Would I have to include any additional information in the configuration to not have this problem with null?
-
In your expression, you are not guarding for entities that have
binary_sensor
but do not havemotion_sensor
, and vice versa. Use the coalescing member access operator?.
in the two sub-expressions.