  1. Home
  2. Software
  3. Multi-System Reactor
  4. [SOLVED] 'not in' being ignored latest-22240-3b3254d6
Organizing/ structuring rule sets and rules
R

Hi guys,

Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular.

Maybe there are better ways to organize my rule sets.

I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.

Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT

I have installed MSR on a RP5 bare metal and then copied the config and store files. Everything seems to be on the RP5 but I am missing all global expression and I don't see the controller time.

Screenshot 2025-04-06 201446.png

My browser is Microsoft Edge Version 135.0.3179.54 (Official build) (64-bit)

I have probably done something stupid or missed a step but I am stuck.

Thanks for any help.

Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M

Hi,
It seems that the widget deletion does not work. I tried to drag the widget to the left (as explained in here https://smarthome.community/topic/1071/deleting-widgets?_=1744037333660)
but it does not delete it. Anyone else experiencing the same problem?

Also the landing page after login is empty and seems be have some JS issues on the dev console:

Screenshot from 2025-04-07 18-06-19.png

fd7f0424-debb-49d3-86d8-9a3b09ad3868-image.png

Using dockerized version of Reactor (Multi-hub) latest-25082-3c348de6 on Chromium 135.0.7049.52 (Official Build) snap (64-bit)

br,
mgvra

Multi-System Reactor
Need help reducing false positive notifications
T

Good day all,
I have an notification set up for my washing machine to let me know when it's complete. I have a templete sensor set up in HAAS to let me know if it's Washing, in Standby, or off, based upon the power consumption (Shelly 1PM on outlets)

- name: "Washing Machine" state: > {% if states("sensor.washer_switch_0_power")|float == 0 %} Off {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %} Standby {% else %} Washing {% endif %} icon: > {% if states("sensor.washer_switch_0_power") == "off" %} mdi:washing-machine-alert {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %} mdi:washing-machine-off {% else %} mdi:washing-machine {% endif %} minutes: 2

The MSR code is relatively simple. I have a built in false positive attribute for if MSR gets rebooted, because I would suddenly get tons of notifications when I upgraded MSR.

6774565a-06cc-443f-99c1-e71301b33d83-image.png

What I'm trying to introduce, is a way to verify that I just didn't bump the knob on the washing machine when transferring loads from the washer to the dryer, which turns on the display and brings the power above the Standby threshold.

The power goes up to 3.7W for about 4 minutes if the selector knob is bumped/turned.

What would the best way to do this be? I have most of my MSR code set up for a couple of years now, and my coding logic is struggling a bit.

I think I need a power threshold to be substained for a minimum time period (say 2 or 3 minutes, above 10W), before the other triggers can act. What would the best way to do that be?

Running: latest-25082-3c348de6
Fedora 41 Server
HAAS:
Core
2025.3.4
Supervisor
2025.03.4
Operating System
15.1
Frontend
20250306.0

Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT

Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.

Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Deleting widgets
tunnusT

Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266

Multi-System Reactor
MQTT configuration question
tunnusT

I have the following yaml configuration in local_mqtt_devices file

x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }'

While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?

Multi-System Reactor
System Configuration Check - time is offset
F

Hi!

I get this message when I'm on the status tab:

System Configuration Check
The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds.

I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6.
HA versions are:
Core 2025.3.4
Supervisor 2025.03.4
Operating System 15.1

I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version.
Do anyone know what I can try?
Thanks in advance!
Let's Be Careful Out There (Hill Street reference...) 🙂
/Fanan

Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT

I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB.

While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed.

So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response.

While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits

Thanks!

Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N

Hi ,
I'm on
-Reactor (Multi-hub) latest-25067-62e21a2d
-Docker on Synology NAS
-ZWaveJSUI 9.31.0.6c80945

Problem with ZwaveJSUI:
When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white.
I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui.

I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb".
After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color.

This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite.

x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33}

The "cold white" and "warm white" settings interfer with the rgb color settings.

Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white
are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white.

So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have

x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor

In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set.

x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33

Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this?

x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33}

Thanks in advance.

Multi-System Reactor
Problem with simultaneous notifications.
T

Good day all,
I have a reaction set up, that I use for both troubleshooting and changing home modes when one of my family members either arrive or are leaving. I use the companion app for HAAS on our iPhones, and HAAS reports if the person associated with the iPhone enters or leaves the geofenced area around my home. I'm sure most MSR and HAAS users are familiar with this.

I use this rule set mainly as a condition for other rules, however, as part of troubleshooting, a notification is sent through HAAS to the companion app when the rule becomes true. The problem is that I'm getting notifications now for both arriving and departing simultaneously.

96b3f7db-ba09-499e-a78c-86903b603857-image.png

36903cdd-a87f-473b-82ef-af9ef96d3c44-image.png It used to work fine as intended. I'm not sure exactly when it changed, but now I'm getting two notifications when either of these conditions change.

Any idea what could be happening?

Edit:
Running: latest-25082-3c348de6, bare-metal Linux
ZWaveJSControllerr [0.1.25082]

Multi-System Reactor
Problem after upgrading to 25067
R

MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem?
I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.

Multi-System Reactor
Global expressions not always evaluated
tunnusT

Similarly as for local expressions, global expressions evaluate and update fine when getEntity(...) structure is used. However, at least when certain functions are in use, expressions do not update.

Consider the following test case:

Screenshot 2025-03-13 at 16.29.42.png

Even though auto-evaluation is active, value does not change (it changes only if that expression is manually run). MSR restarts do not help.

Screenshot 2025-03-13 at 16.31.43.png

Note: Tested using build 25067 on Docker. I have also a PR open (but couldn't now get details or PR number as my Mantis account was somehow expired?).

Multi-System Reactor
[Solved] Local expression evaluation
V

Trying to understand what cause a local expresssion to be evaluated. I have read the manual but I am still not clear about it. Using the test rule below, I can see in the log that the rule is being automatically evaluated every time the temperature entity is changing. That is great...

What I am trying to understand is why the expression is not evaluated based on time as well since the "case" statement has time dependencies.

Any help would be appreciated

I have the following test rule:

eba6a3ea-ff61-4610-88c9-9b9864f11ff8-Screenshot 2025-01-21 095244.png

2d9c1ff5-7b73-4005-b324-9029c2709db9-Screenshot 2025-01-21 095302.png

Here is the expressioncode:

vFrom1 = "09:25:00", vFrom2 = "09:30:00", vFrom3 = "09:41:00", vTo = "10:55:00", # Get current time (format HH:MM:SS) vToDay = strftime("%H:%M:%S"), #Get current house temperature CurrentHouseTemp = getEntity( "hass>Thermostat2 " ).attributes.temperature_sensor.value, case when CurrentHouseTemp <= 19 and vToDay >= vFrom1 && vToDay <= vTo: "true1" # From1 when CurrentHouseTemp <= 20 and vToDay >= vFrom2 && vToDay <= vTo: "true2" # From2 when CurrentHouseTemp < 26  and vToDay >= vFrom3 && vToDay <= vTo: "true3" # From3 else "false" end
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S

I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved.

The Runtime Error is different in the two browsers
Safari v18.3

@http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.

Google Chrome 133.0.6943.142

TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.

Steps to reproduce:
Click the pencil to edit a global reaction with a group.
Click the Exit button.
Runtime error appears.
or
Click Create Reaction
Click Add Action
Select Group
Add Condition such as Entity Attribute.
Add an Action.
Click Save
Click Exit
Runtime error appears.

I don’t know how long the error has been there as I haven’t edited the global reaction in a long time.

Reactor (Multi-hub) latest-25060-f32eaa46
Docker
Mac OS: 15.3.1
Thanks

Multi-System Reactor
Cannot delete Global Expressions
SnowmanS

I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons.

I have not created a global expression for some times and just noticed this while doing some clean-up.

I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success.

Here's what the log shows.

[latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" }

Reactor latest-25067-62e21a2d
Docker on Synology NAS

Multi-System Reactor
Local notification methods?
CatmanV2C

Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method.

This was prompted by yesterday's fun and games with my ISP.

I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone)

I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions?

TIA

C

Multi-System Reactor
Custom capabilities in MQTT templates
M

Hi,
I'm trying to integrate the sonos-mqtt (https://sonos2mqtt.svrooij.io/) with the MSR and it's coming along nicely so far.
But cannot wrap my head around how to define custom capabilities in MQTT templates. I need this for the TTS announcements and similarly for the notification sounds where I would pass the sound file as parameter.

So this is what I have in the local_mqtt_devices.yaml

capabilities: x_sonos_announcement: attributes: actions: speak: arguments: text: type: string volume: type: int delay: type: int

And this is the template:

templates: sonos-announcement: capabilities: - x_sonos_announcement actions: x_sonos_announcement: speak: topic: "sonos/cmd/speak" payload: expr: > { "text": parameters.text, "volume": parameters.volume, "delayMs": parameters.delay, "onlyWhenPlaying": false, "engine": "neural" } type: json

So the speak action should send something like this to topic sonos/cmd/speak

{ "text": "message goes here", "volume": 50, "delayMs": 100, "onlyWhenPlaying": false, "engine": "neural" }

At startup the MSR seems to be quite unhappy with my configuration:

reactor | [latest-25016]2025-02-09T08:19:59.029Z <MQTTController:WARN> MQTTController#mqtt entity Entity#mqtt>sonos-announcement unable to configure capabilities [Array][ "x_sonos_announcement" ] reactor | i18n: missing fi-FI language string: Configuration for {0:q} is incomplete because the following requested capabilities are undefined: {1} reactor | i18n: missing fi-FI language string: Configuration for {0:q} has unrecognized capability {1:q} in actions reactor | Trace: Configuration for {0:q} is incomplete because the following requested capabilities are undefined: {1} reactor | at _T (/opt/reactor/server/lib/i18n.js:611:28) reactor | at AlertManager.addAlert (/opt/reactor/server/lib/AlertManager.js:125:25) reactor | at MQTTController.sendWarning (/opt/reactor/server/lib/Controller.js:627:30) reactor | at MQTTController.start (/var/reactor/ext/MQTTController/MQTTController.js:268:26) reactor | at async Promise.allSettled (index 0) Configuration for "sonos-announcement" has unrecognized capability "x_sonos_announcement" in actions Controller: MQTTController#mqtt Last 10:21:37 AM Configuration for "sonos-announcement" is incomplete because the following requested capabilities are undefined: x_sonos_announcement Controller: MQTTController#mqtt Last 10:21:37 AM

This is probably a pretty stupid question and the approach may not even work at all, but maybe someone or @toggledbits for sure, could point me to the right direction.
Basically the idea is to be able to send TTS messages from reactions using entity actions. I've previously used HTTP requests to Sonos HTTP API (https://hub.docker.com/r/chrisns/docker-node-sonos-http-api/) for the same functionality, but since moving to sonos-mqtt, I need a way to send the TTS notifications using MQTTController. Along with the actual message, volume and delay must also be parameterizable.

br,
mgvra

MSR latest-25016-d47fea38 / MQTTController [0.2.24293]

Multi-System Reactor
[SOLVED]Hass websocket falsely reporting ready on boot??
V

Hi, @toggledbits

I just noticed that following a reboot of my raspberry pi, some of the rules, that I was expecting to recover, are not catching up following a reboot. I have made a simple test rule (rule-m6rz6ol1) with only "after Date/time" as trigger and "turn on a lamp" as a set reaction. All my infrastructure is on the same board so Reactor, Hass, Zwavejs, ... are all rebooting.

Here is the sequence of the test case (All time converted to Zulu to match logs):

Rule "after Date/Time" set to 14:05:00z Shutdown on Raspberry Pi at 14:04:00z Power back up at 14:08:00z Rule overview shows true as of 14:08:14z waiting for 00:00:00 in GUI

From the log I can see that MSR is picking up the rule and knows that the state of the rule has changed from false to true and tries to send the update to HASS but failed with websocket error.

Here is what I see from the log:

14:04:04z shutdown complete 14:08:08z Power up 14:08:13.111z websocket connection 14:08:15:323z Reaction to the light failed, Websocket not opened After there is a series of websocket connection attempt until 14:08:51z where it seemed to be really ready.

Back in 2021 we had a discussion (https://smarthome.community/topic/700/solved-start-up?_=1738766986566) and you proposed to add a startup_delay:xxxx and startup_wait:xxxx parameter in the engine section of "reactor.yaml". When I try the startup_delay (this used to be a hard delay), the engine failed to start (I think). I then try the startup_wait:xxxx without any success. Since it wait for the connection status to be up to cancel the delay, it does not do anyting since Hass is reporting the socket up without really being up ( I think...).

Questions:

Did I figured it all wrong? should the startup_delay:xxxxx have worked? Any ideas?

Here is the log:

OK now I am stuck. I did add the log but when I submit the editor complained saying that I am limited to 32767 characters. The log from the shutdown to the time the websocket is stable is about 300000 character long. What are my options?

Multi-System Reactor
[SOLVED]Logs permissions for Docker Install
V

Not a big issue simply a request if easily doable.

The MSR logs files inside the container are owned by root witch is fine however, the permissions are very restrictive. I do not know if there is something wrong with my installation but the logs permission are set to 222 (write only). Even if the docker volume is set for Read/Write the log files are retaining these values.

I go around the problem by doing a chmod 777 on all reactor logs but every time there is an MSR log rotation the permissions are set back to 222. So unless the permission are implemented in the container there is no permanent solution to this (that I know of).

I do not know much about Docker container so I do not know what is involved here.

Can the logfiles permission be simply chaged in the container to at least allow "other" read permission?

Could the MSR log rotation routine implement a chmod to set the permission?

Just a small anoyance

Thanks

Multi-System Reactor

[SOLVED] 'not in' being ignored latest-22240-3b3254d6

Scheduled Pinned Locked Moved Multi-System Reactor
27 Posts 5 Posters 1.6k Views
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • G Offline
    G Offline
    gwp1
    replied to Alan_F on last edited by
    #8

    @alan_f I’ve centralized all my rules in MSR. How are you reliably determining presence?

    Btw, @toggledbits , I’m Away and it flipped back to ‘Day’.

    I’ll see what the logs look like when I get home.

    G A 2 Replies Last reply
    0
    • G Offline
      G Offline
      gwp1
      replied to gwp1 on last edited by
      #9

      Aaaaaaand it just flipped to ‘Evening’ and I’m very def still Away.

      G 1 Reply Last reply
      0
      • G Offline
        G Offline
        gwp1
        replied to gwp1 on last edited by gwp1
        #10

        I've pulled logs and screenshots and will upload what I can once laptop is finished syncing files.

        toggledbitsT 1 Reply Last reply
        0
        • toggledbitsT Offline
          toggledbitsT Offline
          toggledbits
          replied to gwp1 on last edited by toggledbits
          #11

          @gwp1 Also I will need all of your storage folder, and a complete description of the problem with enough specifics ("it changed" -- what is "it"? And how did it change and why is that not right? And the time of the event to correlate to the logs) and how each of the rules and reactions involved is intended to work. Full logs. No snips. Screenshots as well.

          I will PM an upload link here for you shortly.

          Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

          G 1 Reply Last reply
          0
          • G Offline
            G Offline
            gwp1
            replied to toggledbits on last edited by gwp1
            #12

            @toggledbits Uploaded.

            "It" refers to Mode.

            The ruleset for AWAY is based on presence. Day and Evening have their rulesets which govern their use and both include the exception of Away which was not being honored since I deployed 22240 (but had been previously as these rulesets are older.)

            I've begun looking at them in earnest to see if there's fat that could be trimmed as they are very restrictive in my attempt to avoid false triggering of presence which opens the garage door.

            Day should be from sunrise and/or alarm clock time to sunset.
            Evening should be from sunset until 0130 ET, Night mode enablement (manual) or, if Away, 2330 ET.
            Away should be any time presence is not detected by Home Assistant plugin iCloud3.

            1 Reply Last reply
            0
            • toggledbitsT Offline
              toggledbitsT Offline
              toggledbits
              wrote on last edited by toggledbits
              #13

              Got your files. I need timestamps for what you want me to look at.

              Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

              1 Reply Last reply
              0
              • toggledbitsT Offline
                toggledbitsT Offline
                toggledbits
                wrote on last edited by toggledbits
                #14

                I went on a quick fishing expedition to see if I could bulk search out anything obvious.

                Unfortunately, your storage doesn't completely sync with your logs. There are IDs for rules logged that don't exist in storage. If you've been editing/restructuring rules trying to solve this since the last time you caught the problem, that could cause this. So my comment below may reflect what I'm seeing before those edits, but nonetheless...

                Preliminary review of the logs shows that your "Away" logic triggers your "Day" logic and causes a house mode change. At 23:16:30.474Z the system received notification from Hubitat of a house mode change to Away. This appears to be stimulated by a global reaction called "Mode:
                Away" a few milliseconds earlier. This causes the evaluation of large number of rules. It is about two seconds before that reaction completes, having set a global variable as its last step at 23:16:32.162. Among the activities in that span of time is that a rule called "Day (from Away if before sunset)" (which I don't have in your storage, so I can't examine it) goes set, and its Set reaction starts the global reaction called "Mode: Day", which then sets the Hubitat mode to Day (and that event makes a round trip back to Reactor at 23:16:32.514 causing other changes). That's a bit suspicious. Shouldn't it stay in Away? It seems like Away would be an overriding mode?

                Anyway, at the moment, I'm saying that "not in" works fine, and you have a logic error/unexpected interaction. There appear to be a lot of complex interactions between several reactions that are run by the rules, and I suspect you have things stomping on each other. You may also be able to see this in the Rule History and Reaction History widgets in the status view. And of course, you can always confirm the current mode Reactor thinks the system is in by looking at the Mode entity, and comparing that value to the "current value" in the status for various rules.

                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                G 1 Reply Last reply
                0
                • G Offline
                  G Offline
                  gwp1
                  replied to toggledbits on last edited by gwp1
                  #15

                  @toggledbits What you described is exactly what I was experiencing - I'm reviewing some rulesets now. I think, over time, I've overcomplicated things due to false positives in presence detection. I miss Lobo lol

                  What still doesn't make sense is how this was working fine until 22240 dropped in. Unless something way downstream of this was impacted by 22240 and that ran itself back upstream resulting in my experience.

                  Thanks for looking at this - I'm going to begin a top>down review.

                  toggledbitsT 1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    replied to gwp1 on last edited by
                    #16

                    @gwp1 Changes in 22240 were really limited, and not related to Engine work at all. I think it's more likely you had a race condition between conflicting rules, and the upgrade changed the timing of the race. That can be complicated by the performance of the hub (i.e. variances in how fast it responds to requests), etc. Keep in mind that when you have a reaction start another reaction, they both run at the same time; the starter doesn't wait for the started to finish. And further, there's no guaranteed order to which resumes if both delay to the same instant in time. Unlike Reactor for Vera, which was pretty single-threaded because of the way the Lua API worked there, MSR is very asynchronous and concurrent.

                    One structure that can help concentrate logic into more viewable/manageable blocks is something like this:

                    82c51832-e3fc-406b-95ac-0f214cb5f21a-image.png

                    Here, the only rule condition is that the Mode changes. The set reaction has groups with constraints for each possible mode, and the actions in that group only run if the current mode matches the constraint. But it keeps everything in one place. I don't think a lot of people are using reaction groups with constraints yet, and I'm not saying it's the right answer for you, but it's something to keep in mind.

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    G therealdbT 4 Replies Last reply
                    2
                    • G Offline
                      G Offline
                      gwp1
                      replied to toggledbits on last edited by gwp1
                      #17

                      @toggledbits This is very intriguing. I admit to having a ginormous amount of rules and conditions (ie, TV on closes the Living Room curtain upon Evening mode - but what if the TV was already on prior to Evening mode, we don't want the curtain closed during the daytime hours, and what if I ran out to the store and the house switched to Away mode and then back again etc.)

                      1 Reply Last reply
                      0
                      • G Offline
                        G Offline
                        gwp1
                        replied to toggledbits on last edited by gwp1
                        #18

                        @toggledbits So how does this approach account for the breaking out of lighting, HVAC, blinds, etc.? Is it recommended to link out to other rulesets or drive the actions right from here? That could/would result in quite a list of things happening under each of these groups, no?

                        1 Reply Last reply
                        0
                        • therealdbT Offline
                          therealdbT Offline
                          therealdb
                          replied to toggledbits on last edited by
                          #19

                          @toggledbits said in 'not in' being ignored latest-22240-3b3254d6:

                          I don't think a lot of people are using reaction groups with constraints yet

                          I am and I like it a lot, since you’ll end up with less rule sets and it’s definitely easier to thinker. I’m also using groups with constraints in global reactions.

                          --
                          On a mission to automate everything.

                          My MS Reactor contrib
                          My Luup Plug-ins

                          G CatmanV2C 2 Replies Last reply
                          2
                          • G Offline
                            G Offline
                            gwp1
                            replied to therealdb on last edited by
                            #20

                            @therealdb I'd like to better understand the grouping you're using with this. Lights vs blinds vs presence vs HVAC, etc.

                            1 Reply Last reply
                            0
                            • G Offline
                              G Offline
                              gwp1
                              wrote on last edited by
                              #21

                              I can confirm that @toggledbits assessment was correct. Closing this up but I'd really like to chat with either @toggledbits or @therealdb about implementation of reaction groups with constraints.

                              1 Reply Last reply
                              0
                              • CatmanV2C Offline
                                CatmanV2C Offline
                                CatmanV2
                                replied to therealdb on last edited by
                                #22

                                @therealdb even I have one!

                                C

                                The Ex-Vera abuser know as CatmanV2.....

                                1 Reply Last reply
                                0
                                • A Offline
                                  A Offline
                                  Alan_F
                                  replied to gwp1 on last edited by
                                  #23

                                  @gwp1 I was away from the forum for a few days, but to answer your question, I use the Hubitat app for Android on my phone and my wife's phone to determine presence. Every once in a while they break it with an update and I can use the Google assistant presence instead. I prefer Hubitat because you can set a geofence and I have them set up not to consider us away when walking the dogs in the neighborhood, but to have us away when we're at my parent's house just outside our usual walking route. Google doesn't give me that level of control over what's considered home or away.

                                  G 1 Reply Last reply
                                  0
                                  • G Offline
                                    G Offline
                                    gwp1
                                    replied to Alan_F on last edited by
                                    #24
                                    This post is deleted!
                                    1 Reply Last reply
                                    0
                                    • G Offline
                                      G Offline
                                      gwp1
                                      replied to toggledbits on last edited by gwp1
                                      #25

                                      @toggledbits @toggledbits took your advice above and tried something new with my Living Room blinds and TV watching. The issues are:

                                      • If watching TV during the daylight hours, light from the windows on either side of the fireplace-mounted TV tend to wash it out a bit, esp during night scenes.

                                      • If watching TV at night, the neighbors have a pair of floodlights on their patio that, when in use, don't stream into my windows but do sit there in your field of view as these two white orbs. Very distracting.

                                      My "try something new" solution is this:

                                      26423419-f469-445c-aa43-e175122be7f8-image.png

                                      c6260d1e-8889-476f-b2a7-0996cab7d949-image.png

                                      0b3a06c5-c249-43fa-893a-9618f23268b3-image.png

                                      (I've stricken the Mode Constraint from the above - it's redundant and too restrictive - what if I run out to the store real quick and the house flips to Away?

                                      0dbe1513-f1f3-47b5-bf78-355081422d74-image.png

                                      There is no Reset Reaction for Evenings because why? Just leave them closed as most likely the next stop is sleepy-time when they'll be closed anyway.

                                      Your thoughts?

                                      1 Reply Last reply
                                      0
                                      • toggledbitsT Offline
                                        toggledbitsT Offline
                                        toggledbits
                                        wrote on last edited by
                                        #26

                                        Looks good to me!

                                        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                        G 1 Reply Last reply
                                        1
                                        • G Offline
                                          G Offline
                                          gwp1
                                          replied to toggledbits on last edited by
                                          #27

                                          @toggledbits After I saw this post I tested the daytime version and it behaved as intended. Half the battle down, we'll test the other half this evening. Thanks for the guidance here, it's a different approach but I can def see places where it's useful.

                                          1 Reply Last reply
                                          1
                                          • toggledbitsT toggledbits locked this topic on

                                          Recent Topics

                                          • Disaster recovery and virtualisation
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            5
                                            539

                                          • Remote access of Zwave stick from Z-wave server
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            3
                                            244

                                          • Organizing/ structuring rule sets and rules
                                            G
                                            gwp1
                                            0
                                            5
                                            316

                                          • Moving MSR from a QNAP container to RP 5 - some issues
                                            G
                                            gwp1
                                            0
                                            5
                                            277

                                          • Widget deletion does not work and landing page (status) is empy
                                            G
                                            gwp1
                                            0
                                            4
                                            250

                                          • Need help reducing false positive notifications
                                            T
                                            tamorgen
                                            0
                                            7
                                            435

                                          • Reactor (Multi-System/Multi-Hub) Announcements
                                            toggledbitsT
                                            toggledbits
                                            5
                                            120
                                            35.1k

                                          • Deleting widgets
                                            toggledbitsT
                                            toggledbits
                                            0
                                            4
                                            426

                                          • MQTT configuration question
                                            tunnusT
                                            tunnus
                                            0
                                            11
                                            573

                                          • System Configuration Check - time is offset
                                            G
                                            gwp1
                                            0
                                            8
                                            549
                                          Powered by NodeBB | Contributors
                                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                          • Login

                                          • Don't have an account? Register

                                          • Login or register to search.
                                          • First post
                                            Last post
                                          0
                                          • Categories
                                          • Recent
                                          • Tags
                                          • Popular
                                          • Unsolved