Advice reqeusted to migrate MSR from Bare Metal to Container
T
Good day all, I'm in the process of trying to shut down my 10 year old Linux home server that served many purposes, but primarily it's what I used for my NAS/Plex Media server. I migrated the NAS aspect of the server in November of last year to a true NAS solution (Ubiquti UNAS Pro), which is rack mount and much more efficient than my old tower, which it's only side benefit was heating my home office during the winter. Unfortunately it also means heating my home office during the summer, which were about to be in full swing. I have two things running on this 10 year old server at this point. MSR and pi-hole. I'm running Plex Media Server on Fedora Workstation in Podman on mini PC, which is much more energy efficient than my old tower. My next step is to migrate MSR. I know there are images of MSR out there, and creating it is well documented. I'm going to be using Podman instead of Docker for various reasons, but they work very similar. What I don't know, is what I need to do to migrate my existing Bare Metal installation over to a container. Has anyone done this? Any advice?
Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT
Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here. Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Can´t restart or upgrade/deploy MSR
F
Topic thumbnail image
Multi-System Reactor
[Solved] Limit HA Entity in MSR
wmarcolinW
Topic thumbnail image
Multi-System Reactor
Organizing/ structuring rule sets and rules
R
Hi guys, Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular. Maybe there are better ways to organize my rule sets. I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.
Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT
Topic thumbnail image
Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M
Topic thumbnail image
Multi-System Reactor
Need help reducing false positive notifications
T
Topic thumbnail image
Multi-System Reactor
Deleting widgets
tunnusT
Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266
Multi-System Reactor
MQTT configuration question
tunnusT
I have the following yaml configuration in local_mqtt_devices file x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }' While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?
Multi-System Reactor
System Configuration Check - time is offset
F
Hi! I get this message when I'm on the status tab: System Configuration Check The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds. I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6. HA versions are: Core 2025.3.4 Supervisor 2025.03.4 Operating System 15.1 I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version. Do anyone know what I can try? Thanks in advance! Let's Be Careful Out There (Hill Street reference...) /Fanan
Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT
I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB. While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed. So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response. While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits Thanks!
Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N
Hi , I'm on -Reactor (Multi-hub) latest-25067-62e21a2d -Docker on Synology NAS -ZWaveJSUI 9.31.0.6c80945 Problem with ZwaveJSUI: When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white. I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui. I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb". After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color. This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite. x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33} The "cold white" and "warm white" settings interfer with the rgb color settings. Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white. So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set. x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33 Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this? x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33} Thanks in advance.
Multi-System Reactor
Problem with simultaneous notifications.
T
Topic thumbnail image
Multi-System Reactor
Problem after upgrading to 25067
R
MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem? I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.
Multi-System Reactor
Global expressions not always evaluated
tunnusT
Topic thumbnail image
Multi-System Reactor
[Solved] Local expression evaluation
V
Topic thumbnail image
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S
I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved. The Runtime Error is different in the two browsers Safari v18.3 @http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Google Chrome 133.0.6943.142 TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community. Steps to reproduce: Click the pencil to edit a global reaction with a group. Click the Exit button. Runtime error appears. or Click Create Reaction Click Add Action Select Group Add Condition such as Entity Attribute. Add an Action. Click Save Click Exit Runtime error appears. I don’t know how long the error has been there as I haven’t edited the global reaction in a long time. Reactor (Multi-hub) latest-25060-f32eaa46 Docker Mac OS: 15.3.1 Thanks
Multi-System Reactor
Cannot delete Global Expressions
SnowmanS
I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons. I have not created a global expression for some times and just noticed this while doing some clean-up. I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success. Here's what the log shows. [latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } Reactor latest-25067-62e21a2d Docker on Synology NAS
Multi-System Reactor
Local notification methods?
CatmanV2C
Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method. This was prompted by yesterday's fun and games with my ISP. I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone) I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions? TIA C
Multi-System Reactor

How to monitor sensors that stop working?

Scheduled Pinned Locked Moved Multi-System Reactor
31 Posts 5 Posters 1.6k Views 5 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • A Offline
    A Offline
    Andr
    wrote on last edited by
    #1

    I have some battery powered sensors that doesn't report battery level and thought it would be nice if can make MSR to send me a notification if a sensor value doesn't change for 24h.

    I tried to make a rule that monitored if a temperature value NOT changes, but in this setup I couldn't choose Sustained For as I expected.
    Any way around this?
    Any reason that Sustained For can't be used when monitoring a value Change?

    toggledbitsT 1 Reply Last reply
    0
    • A Andr

      I have some battery powered sensors that doesn't report battery level and thought it would be nice if can make MSR to send me a notification if a sensor value doesn't change for 24h.

      I tried to make a rule that monitored if a temperature value NOT changes, but in this setup I couldn't choose Sustained For as I expected.
      Any way around this?
      Any reason that Sustained For can't be used when monitoring a value Change?

      toggledbitsT Offline
      toggledbitsT Offline
      toggledbits
      wrote on last edited by toggledbits
      #2

      @andr Change is instantaneous. There's no change the instant a change has been noticed. So it's not a sustainable condition.

      The solution is in the way you phrase the problem: "send me a notification if a sensor value doesn't change for 24h". In other words, if changes is false is sustained for 24 hours. Since changes can only signal true (false is its normal state), you need to wrap the entity condition in a group. Use the NOT group operator to invert the interior test condition. You can assign "sustained for" on this group, and that's exactly what you should do.

      11be2173-d181-47a6-bf27-cab19873253f-image.png

      Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

      1 Reply Last reply
      0
      • A Offline
        A Offline
        Andr
        wrote on last edited by
        #3

        Thank you

        wmarcolinW 1 Reply Last reply
        0
        • A Andr

          Thank you

          wmarcolinW Offline
          wmarcolinW Offline
          wmarcolin
          wrote on last edited by
          #4

          @andr I will try to collaborate with two suggestions for you to validate your device.

          The first one with the screen below is to validate your sensors with battery information:
          sensor = prepares the list of which devices have the battery power variable
          low_battery = checks who has less than 50% charge
          names: make a list with names to send alerts

          002a1902-703c-440d-8546-21285032488c-image.png

          The second option is very similar, but I am using the CommFailure variable which depends on an invocation of the device for it to appear as failed, i.e., the same one as in the Vera device list.

          f0726031-a48d-4b84-a6c4-8f7f8ed672ab-image.png

          But I open a question here for our master @toggledbits.

          If the Vera hub has the Poll parameter on all devices, I understand that a call is made from time to time. In this case, using the two examples above, couldn't there be something that the validation would then be if a Polling fails to trigger the error? What would this variable or test time be? How would we express a current time equation - 6 hours to test?

          Thanks

          A B 3 Replies Last reply
          0
          • toggledbitsT Offline
            toggledbitsT Offline
            toggledbits
            wrote on last edited by
            #5

            Vera keeps track of its own polling failures, which you can see most usefully for this kind of application in the entity attribute x_vera_svc_micasaverde_com_ZWaveNetwork1.ConsecutivePollFails.

            Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

            wmarcolinW B 2 Replies Last reply
            0
            • toggledbitsT toggledbits

              Vera keeps track of its own polling failures, which you can see most usefully for this kind of application in the entity attribute x_vera_svc_micasaverde_com_ZWaveNetwork1.ConsecutivePollFails.

              wmarcolinW Offline
              wmarcolinW Offline
              wmarcolin
              wrote on last edited by
              #6

              @toggledbits this variable I can't understand how it works to return to zero, because I have a case here that is different from zero but the device is working normally. It may be a historical accumulation.

              1 Reply Last reply
              0
              • wmarcolinW wmarcolin

                @andr I will try to collaborate with two suggestions for you to validate your device.

                The first one with the screen below is to validate your sensors with battery information:
                sensor = prepares the list of which devices have the battery power variable
                low_battery = checks who has less than 50% charge
                names: make a list with names to send alerts

                002a1902-703c-440d-8546-21285032488c-image.png

                The second option is very similar, but I am using the CommFailure variable which depends on an invocation of the device for it to appear as failed, i.e., the same one as in the Vera device list.

                f0726031-a48d-4b84-a6c4-8f7f8ed672ab-image.png

                But I open a question here for our master @toggledbits.

                If the Vera hub has the Poll parameter on all devices, I understand that a call is made from time to time. In this case, using the two examples above, couldn't there be something that the validation would then be if a Polling fails to trigger the error? What would this variable or test time be? How would we express a current time equation - 6 hours to test?

                Thanks

                A Offline
                A Offline
                Andr
                wrote on last edited by
                #7

                @wmarcolin
                Ok, Expressions isn't anything I have used before. But I noticed the thread about low battery notifications and added this to my list of needed knowledge in the future.
                Either way, I copied your Expressions and devices got listed as expected.
                But how do I get that list in a notification??

                I think that many kind of sensors can need at least two rules/values for checking for failure.
                For example I have a Fibaro Smokesensor that just stop reporting. But either Hass or Vera notice that the device doesn't communicate.
                This device has a temp.sensor, which of course will (should) change value a lot more than battery level.
                I think battery level is the least wanted value to monitor for the sake of device failure. Since some devices can have a battery life of several years the value moves to slow.

                wmarcolinW 1 Reply Last reply
                0
                • toggledbitsT toggledbits

                  Vera keeps track of its own polling failures, which you can see most usefully for this kind of application in the entity attribute x_vera_svc_micasaverde_com_ZWaveNetwork1.ConsecutivePollFails.

                  B Offline
                  B Offline
                  Buxton
                  wrote on last edited by
                  #8

                  @toggledbits One of the last things keeping me from localizing my vera is that the cloud will notify me when a zwave device goes offline. It's important for me to know as some of my devices are connected to security functions.

                  Do you know if the offline notice is tied to "x_vera_svc_micasaverde_com_ZWaveNetwork1.ConsecutivePollFails" and if so, the count/number of fails that vera uses to send a device offline notice? My distant zwave devices tend to rack up a lot of fails, but I never get an offline notice sent to me.

                  I'd much rather prefer to handle that error condition locally, and if it can be done, I can then run your Vera Decouple script.

                  1 Reply Last reply
                  0
                  • toggledbitsT Offline
                    toggledbitsT Offline
                    toggledbits
                    wrote on last edited by
                    #9

                    I do not know how their notification works or what their thresholds are.

                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                    1 Reply Last reply
                    0
                    • wmarcolinW wmarcolin

                      @andr I will try to collaborate with two suggestions for you to validate your device.

                      The first one with the screen below is to validate your sensors with battery information:
                      sensor = prepares the list of which devices have the battery power variable
                      low_battery = checks who has less than 50% charge
                      names: make a list with names to send alerts

                      002a1902-703c-440d-8546-21285032488c-image.png

                      The second option is very similar, but I am using the CommFailure variable which depends on an invocation of the device for it to appear as failed, i.e., the same one as in the Vera device list.

                      f0726031-a48d-4b84-a6c4-8f7f8ed672ab-image.png

                      But I open a question here for our master @toggledbits.

                      If the Vera hub has the Poll parameter on all devices, I understand that a call is made from time to time. In this case, using the two examples above, couldn't there be something that the validation would then be if a Polling fails to trigger the error? What would this variable or test time be? How would we express a current time equation - 6 hours to test?

                      Thanks

                      B Offline
                      B Offline
                      Buxton
                      wrote on last edited by
                      #10

                      @wmarcolin I'll get a device offline notice approximately 24 hours after a device is disconnected. Perhaps vera is using a combination of the two metrics to trigger an offline email ie once 24 hours passes without a poll response, the CommFailure for the device goes true and an Email is sent.

                      1 Reply Last reply
                      0
                      • wmarcolinW wmarcolin

                        @andr I will try to collaborate with two suggestions for you to validate your device.

                        The first one with the screen below is to validate your sensors with battery information:
                        sensor = prepares the list of which devices have the battery power variable
                        low_battery = checks who has less than 50% charge
                        names: make a list with names to send alerts

                        002a1902-703c-440d-8546-21285032488c-image.png

                        The second option is very similar, but I am using the CommFailure variable which depends on an invocation of the device for it to appear as failed, i.e., the same one as in the Vera device list.

                        f0726031-a48d-4b84-a6c4-8f7f8ed672ab-image.png

                        But I open a question here for our master @toggledbits.

                        If the Vera hub has the Poll parameter on all devices, I understand that a call is made from time to time. In this case, using the two examples above, couldn't there be something that the validation would then be if a Polling fails to trigger the error? What would this variable or test time be? How would we express a current time equation - 6 hours to test?

                        Thanks

                        B Offline
                        B Offline
                        Buxton
                        wrote on last edited by Buxton
                        #11

                        @wmarcolin Here's a do loop that uses the device.failed attribute:

                        join( 
                          each id in matchEntities( { controller: 'vera', capability: 'x_vera_device' } ): do
                            e=getEntity( id ), 
                            e.attributes.x_vera_device.failed ? e.name :  null
                          done, ", " )
                        

                        I have one device offline that shows up in the array and the device is offline as I physically removed it a couple of days ago. As well, I'm seeing one plugin that has this attribute set to true, although it is working. Perhaps something in the plugin code needs to reset the device from true to false if the plugin regains communication....

                        Edit: the plugin that was showing failure used "luup.set_failure false" instead of 0 or 1. This is probably an openLuup bug as using false in this case is a holdover from UI5. I changed false to 0, and the plugin no longer shows as failed. http://wiki.micasaverde.com/index.php/Luup_Lua_extensions#function:_set_failure

                        B 1 Reply Last reply
                        0
                        • B Buxton

                          @wmarcolin Here's a do loop that uses the device.failed attribute:

                          join( 
                            each id in matchEntities( { controller: 'vera', capability: 'x_vera_device' } ): do
                              e=getEntity( id ), 
                              e.attributes.x_vera_device.failed ? e.name :  null
                            done, ", " )
                          

                          I have one device offline that shows up in the array and the device is offline as I physically removed it a couple of days ago. As well, I'm seeing one plugin that has this attribute set to true, although it is working. Perhaps something in the plugin code needs to reset the device from true to false if the plugin regains communication....

                          Edit: the plugin that was showing failure used "luup.set_failure false" instead of 0 or 1. This is probably an openLuup bug as using false in this case is a holdover from UI5. I changed false to 0, and the plugin no longer shows as failed. http://wiki.micasaverde.com/index.php/Luup_Lua_extensions#function:_set_failure

                          B Offline
                          B Offline
                          Buxton
                          wrote on last edited by
                          #12

                          @rafale77 does a deep dive into failed vera zwave devices in this thread: https://smarthome.community/topic/392/vera-device-extended-attributes

                          1 Reply Last reply
                          0
                          • A Andr

                            @wmarcolin
                            Ok, Expressions isn't anything I have used before. But I noticed the thread about low battery notifications and added this to my list of needed knowledge in the future.
                            Either way, I copied your Expressions and devices got listed as expected.
                            But how do I get that list in a notification??

                            I think that many kind of sensors can need at least two rules/values for checking for failure.
                            For example I have a Fibaro Smokesensor that just stop reporting. But either Hass or Vera notice that the device doesn't communicate.
                            This device has a temp.sensor, which of course will (should) change value a lot more than battery level.
                            I think battery level is the least wanted value to monitor for the sake of device failure. Since some devices can have a battery life of several years the value moves to slow.

                            wmarcolinW Offline
                            wmarcolinW Offline
                            wmarcolin
                            wrote on last edited by
                            #13

                            @andr I'm using Telegram, but I think this work for all

                            <b>BATTERY LOWER THAN 30%</b>
                            Check the devices listed that have the battery below the desired charge: ${{BatteryMSG}}.

                            <b>DEVICE WITH ERROR</b>
                            Check the listed devices that have a communication failure: ${{FaultMSG}}.

                            I am trying to better understand how the CommFailure variable is updated. Devices plugged into power as soon as it is cut off, update on the fly, now on battery power it doesn't. I am looking to see how to force this update, this would solve a validation of all devices that do not respond to the hub.

                            1 Reply Last reply
                            0
                            • wmarcolinW Offline
                              wmarcolinW Offline
                              wmarcolin
                              wrote on last edited by
                              #14

                              Besides the Variable x_vera_svc_micasaverde_com_HaDevice1.CommFailure I am also checking now the x_vera_device.failed, but the problem is the same, it's not updating, I keep searching how to send some command that forces this update.

                              I looked at the other post that @Buxton suggested and it has the information about the @rafale77 but I also didn't find anything about how to do something to force the re-evaluation of the variables.

                              toggledbitsT 1 Reply Last reply
                              0
                              • wmarcolinW wmarcolin

                                Besides the Variable x_vera_svc_micasaverde_com_HaDevice1.CommFailure I am also checking now the x_vera_device.failed, but the problem is the same, it's not updating, I keep searching how to send some command that forces this update.

                                I looked at the other post that @Buxton suggested and it has the information about the @rafale77 but I also didn't find anything about how to do something to force the re-evaluation of the variables.

                                toggledbitsT Offline
                                toggledbitsT Offline
                                toggledbits
                                wrote on last edited by toggledbits
                                #15

                                @wmarcolin said in How to monitor sensors that stop working?:

                                I also didn't find anything about how to do something to force the re-evaluation of the variables

                                I'm not sure if you're talking about the state variables on the Vera here, or the attributes on the entity in MSR, or the expression variables in MSR, but a few important things:

                                1. Vera's state variables are driven by Luup and the ZWave engine. You have to rely on Luup to set them properly. You can change their value yourself, but that's meaningless, of course: setting CommFailure=1 doesn't mean device communications will fail thereafter, and setting CommFailure=0 when device communication failures are occurring will not cure them. They are state variables, not action variables. If you want a state variable to change related to device behavior, you have to think action: Refresh, Poll, Reconfigure, etc. If those actions result in a change of state, that will update the variables.

                                2. Entities are updated when Vera posts a change for the device. MSR uses Luup's method of sending changes for devices, and that's a pretty old and reliable mechanism, not without problems, but they are well known and would not apply here. The way to update an MSR entity related to a Vera controller is by causing its states to change.

                                3. MSR variables, be they global or rule-based, should update immediately upon a change of the entity, but since 21267, I've been chasing one particular problem that pops up in expressions that use each, first, and do...done. I think I finally found that yesterday. There is an unannounced build 21280 currently posted that contains that fix (I published it for just one person that I'm helping via Mantis). The expression shown in @Buxton 's post is exactly the type of expression affected. I would upgrade to 21280 and retry this experiment.

                                Also, the x_vera_device.failed attribute on Vera device entities is driven entirely from urn:micasaverde-com:serviceId:HaDevice1/CommFailure and there is no other magic there. I just converts the data type (0 if false, anything else is true).

                                Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                wmarcolinW 1 Reply Last reply
                                0
                                • toggledbitsT toggledbits

                                  @wmarcolin said in How to monitor sensors that stop working?:

                                  I also didn't find anything about how to do something to force the re-evaluation of the variables

                                  I'm not sure if you're talking about the state variables on the Vera here, or the attributes on the entity in MSR, or the expression variables in MSR, but a few important things:

                                  1. Vera's state variables are driven by Luup and the ZWave engine. You have to rely on Luup to set them properly. You can change their value yourself, but that's meaningless, of course: setting CommFailure=1 doesn't mean device communications will fail thereafter, and setting CommFailure=0 when device communication failures are occurring will not cure them. They are state variables, not action variables. If you want a state variable to change related to device behavior, you have to think action: Refresh, Poll, Reconfigure, etc. If those actions result in a change of state, that will update the variables.

                                  2. Entities are updated when Vera posts a change for the device. MSR uses Luup's method of sending changes for devices, and that's a pretty old and reliable mechanism, not without problems, but they are well known and would not apply here. The way to update an MSR entity related to a Vera controller is by causing its states to change.

                                  3. MSR variables, be they global or rule-based, should update immediately upon a change of the entity, but since 21267, I've been chasing one particular problem that pops up in expressions that use each, first, and do...done. I think I finally found that yesterday. There is an unannounced build 21280 currently posted that contains that fix (I published it for just one person that I'm helping via Mantis). The expression shown in @Buxton 's post is exactly the type of expression affected. I would upgrade to 21280 and retry this experiment.

                                  Also, the x_vera_device.failed attribute on Vera device entities is driven entirely from urn:micasaverde-com:serviceId:HaDevice1/CommFailure and there is no other magic there. I just converts the data type (0 if false, anything else is true).

                                  wmarcolinW Offline
                                  wmarcolinW Offline
                                  wmarcolin
                                  wrote on last edited by
                                  #16

                                  @toggledbits thank you for your comments, and let's be clear, the MSR is perfect, it reflects exactly the information from Vera's many variables. So it is possible to query x_vera_device.failed or urn:micasaverde-com:serviceId:HaDevice1/CommFailure without any problem, it can be a Global variable that updates immediately, or a routine that I execute every period and it also updates, the problem is definitely not with the MSR.

                                  The question is how to force Vera to fetch the updated status of the device, and then update the variables in the hub (which MSR will then automatically see).

                                  In an old and excellent suggestion from @rafale77 , the wakeup times and the poll (https://community.ezlo.com/t/zwave-network-on-vera-explained/210661/3) have been increased, which has improved the performance of the hub and battery savings, but causes a huge update delay.

                                  So your comment about running a Refresh or Poll is exactly what I am looking for, I understand it should be commanded to not wait for the hub loop, and as you comment, the action should result in the update of the state and variables.

                                  Now what is this command? Where do I find instructions on how to execute this command? Can I have a loop in the MSR to execute based on a device list (example above) of messages?

                                  Thanks

                                  1 Reply Last reply
                                  0
                                  • toggledbitsT Offline
                                    toggledbitsT Offline
                                    toggledbits
                                    wrote on last edited by toggledbits
                                    #17

                                    The zwave_device.reconfigure and zwave_device.refresh actions are available on multiple hubs (it takes a bit of extra config for Home Assistant and Hubitat because they don't "disclose" that a device is a ZWave device through their APIs, but still doable).

                                    Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                    wmarcolinW 1 Reply Last reply
                                    0
                                    • toggledbitsT toggledbits

                                      The zwave_device.reconfigure and zwave_device.refresh actions are available on multiple hubs (it takes a bit of extra config for Home Assistant and Hubitat because they don't "disclose" that a device is a ZWave device through their APIs, but still doable).

                                      wmarcolinW Offline
                                      wmarcolinW Offline
                                      wmarcolin
                                      wrote on last edited by
                                      #18

                                      @toggledbits

                                      This work.

                                      97ade70c-5a06-4305-b588-e4d26ee475e9-image.png

                                      ff2a9d9d-5fd8-417a-af28-38a89c046a6e-image.png

                                      d3c44268-4127-4048-8fa9-3a5f425fdb97-image.png

                                      But after a few seconds the error message disappears, and the error is not displayed, i.e. the variables are not updated.

                                      2aed61ef-6cc9-42d4-9598-c47566c1d7d8-image.png

                                      Incredible! Even after doing a Poll or Refresh, the variables are not updated.

                                      1 Reply Last reply
                                      0
                                      • toggledbitsT Offline
                                        toggledbitsT Offline
                                        toggledbits
                                        wrote on last edited by
                                        #19

                                        Where are you looking to see if the variables are updated?

                                        Author of Multi-system Reactor and Reactor, DelayLight, Switchboard, and about a dozen other plugins that run on Vera and openLuup.

                                        wmarcolinW 1 Reply Last reply
                                        0
                                        • toggledbitsT toggledbits

                                          Where are you looking to see if the variables are updated?

                                          wmarcolinW Offline
                                          wmarcolinW Offline
                                          wmarcolin
                                          wrote on last edited by wmarcolin
                                          #20

                                          @toggledbits here in this query

                                          56132e5b-2a0a-4a51-9f59-ec5b30353873-image.png

                                          Or

                                          e4c91726-8383-4c66-b7ef-88adf5435723-image.png

                                          91c6d358-03e1-4165-a75a-c8192571468a-image.png

                                          Taking as an example the same type of device, but I don't know how and when Vera updated it, see how the same queries appear:

                                          db94a0d5-9561-4b50-9e14-2f034f560407-image.png

                                          96c71690-f0dc-402a-bc69-a21eadd7ef63-image.png

                                          38000151-6959-44be-83c6-f1d096c5fb5a-image.png

                                          The problem is not the query, it is effectively why the hub is not updating the variables after a refresh or poll, and how come then the hub does an operation that does this updating is we can do the same when we want to.

                                          Thanks

                                          1 Reply Last reply
                                          0
                                          Reply
                                          • Reply as topic
                                          Log in to reply
                                          • Oldest to Newest
                                          • Newest to Oldest
                                          • Most Votes


                                          Recent Topics

                                          • Advice reqeusted to migrate MSR from Bare Metal to Container
                                            T
                                            tamorgen
                                            0
                                            5
                                            17

                                          • Reactor (Multi-System/Multi-Hub) Announcements
                                            toggledbitsT
                                            toggledbits
                                            5
                                            122
                                            35.4k

                                          • Z-Wave Future....
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            5
                                            114

                                          • Can´t restart or upgrade/deploy MSR
                                            toggledbitsT
                                            toggledbits
                                            0
                                            4
                                            73

                                          • [Solved] Limit HA Entity in MSR
                                            wmarcolinW
                                            wmarcolin
                                            0
                                            7
                                            178

                                          • Disaster recovery and virtualisation
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            5
                                            652

                                          • Remote access of Zwave stick from Z-wave server
                                            CatmanV2C
                                            CatmanV2
                                            0
                                            3
                                            375

                                          • Organizing/ structuring rule sets and rules
                                            G
                                            gwp1
                                            0
                                            5
                                            370

                                          • Moving MSR from a QNAP container to RP 5 - some issues
                                            G
                                            gwp1
                                            0
                                            5
                                            340

                                          • Widget deletion does not work and landing page (status) is empy
                                            G
                                            gwp1
                                            0
                                            4
                                            330

                                          • Need help reducing false positive notifications
                                            T
                                            tamorgen
                                            0
                                            7
                                            508
                                          Powered by NodeBB | Contributors
                                          Hosted freely by 10RUPTiV - Solutions Technologiques | Contact us
                                          • Login

                                          • Don't have an account? Register

                                          • Login or register to search.
                                          • First post
                                            Last post
                                          0
                                          • Categories
                                          • Recent
                                          • Tags
                                          • Popular
                                          • Unsolved