M

Matteburk

@Matteburk
Disaster recovery and virtualisation
CatmanV2C

Following on from my last thread, some progress has been made over the weekend.

With 18G of spanky RAM in my Synology DS224+. I've jumped into the murky world of virtualisation and already eliminated the need for two Raspberry Pi's from my system.

Home Assistant: In theory they provide an OVA file which is supported by the Synology. I couldn't get it to work, however, so grabbed a copy of the .img file they supply, renamed it .iso and imported it as a VM. Restored from my full back up and that all seems fantastic.

Minidnla Music server: Trivial. Grabbed a Debian .iso for Bookworm and copied that onto the NAS. Created a new machine which mirrored the specs of the Raspberry Pi, booted from the ISO then did an expert install. Once that was all stable with a basic core of stuff and networking, I've made a copy of that as a good base system. Then fired up minidnla on it, mounted my media and that's also woking. Not bad for a short weekend's work.

Still not sure about the main NUC though. I'm thinking of buying a new USB stick so I can mess around getting it working on the Synology before I do anything drastic.

Once that hurdle is sorted I'm torn between:

Using a brand new install of Bookworm, re-installing Z-way server, OpenLuup, AltUI, MSR and HA bridge, then restoring across or Making an ISO of the current system, importing that and upgrading in place (which will be pretty risk free since I can snapshot everything before I make any changes.)

Decisions, decisions.

C

General Discussion
Remote access of Zwave stick from Z-wave server
CatmanV2C

Afternoon, all.

In my continued attempts to virtualise my system, I'm in the last (I hope throes)

I don't fancy relying on Synology not to break more USB activities, so decided to set up ser2net on a Raspberry pi and plug in a spare Z-wave.me stick

So on the Raspberry pi: ser2net. yaml

catman@Zwave:/etc $ cat ser2net.yaml %YAML 1.1 --- # This is a ser2net configuration file, tailored to be rather # simple. # # Find detailed documentation in ser2net.yaml(5) # A fully featured configuration file is in # /usr/share/doc/ser2net/examples/ser2net.yaml.gz # # If you find your configuration more useful than this very simple # one, please submit it as a bugreport define: &banner \r\nser2net port \p device \d [\B] (Debian GNU/Linux)\r\n\r\n connection: &zwave0 # Bind to TCP port accepter: tcp,4000 enable: on options: kickolduser: true # Ensure mDNS is disabled mdns: false connector: serialdev, /dev/ttyACM0,115200N81,nobreak,local

And if I telnet to it from anywhere:

catman@ChrisMBP15-2018 ~ % telnet 192.168.70.128 4000 Trying 192.168.70.128... Connected to 192.168.70.128. Escape character is '^]'.

Which makes me think that ser2net is doing its thing.

Now in my virtualised Z-wave server I have this:

Screenshot 2025-04-10 at 17.36.52.png

(I've tried with a colon and a space between the ip and the port)

The result:

An unexpected error occurred during loading data. Try to reload the page. Please check 1.) if the controller is plugged in correctly, 2.) that in the app 'Z-Wave Network Access' the right port is entered (UZB: '/dev/ttyACM0', RaZberry shield: '/dev/ttyAMA0', UZB-Windows: '\\.\COM3', Z-Stick: '/dev/ttyUSB0', embedded boxes: '/dev/ttyS0' or '/dev/ttyS1') 3.) the app is aktiv. If not you could activate it under Menu > Apps > Active or add a new one under Menu > Apps > Local. The Setting 'Expert View' needs to be active under Menu > My Settings.

Any pointers as to what I'm doing wrong?

TIA!

C

Software
Organizing/ structuring rule sets and rules
R

Hi guys,

Just wondering how you guys organize your rule sets and rules. I wish I had an extra layer to have some more granularity, but my feature request was not popular.

Maybe there are better ways to organize my rule sets.

I use the rule sets now primarily for rooms. So a rule set per room. But maybe grouping by functionality works better. Any examples/ suggestions would be appreciated.

Multi-System Reactor
Moving MSR from a QNAP container to RP 5 - some issues
Tom_DT

I have installed MSR on a RP5 bare metal and then copied the config and store files. Everything seems to be on the RP5 but I am missing all global expression and I don't see the controller time.

Screenshot 2025-04-06 201446.png

My browser is Microsoft Edge Version 135.0.3179.54 (Official build) (64-bit)

I have probably done something stupid or missed a step but I am stuck.

Thanks for any help.

Multi-System Reactor
Widget deletion does not work and landing page (status) is empy
M

Hi,
It seems that the widget deletion does not work. I tried to drag the widget to the left (as explained in here https://smarthome.community/topic/1071/deleting-widgets?_=1744037333660)
but it does not delete it. Anyone else experiencing the same problem?

Also the landing page after login is empty and seems be have some JS issues on the dev console:

Screenshot from 2025-04-07 18-06-19.png

fd7f0424-debb-49d3-86d8-9a3b09ad3868-image.png

Using dockerized version of Reactor (Multi-hub) latest-25082-3c348de6 on Chromium 135.0.7049.52 (Official Build) snap (64-bit)

br,
mgvra

Multi-System Reactor
Need help reducing false positive notifications
T

Good day all,
I have an notification set up for my washing machine to let me know when it's complete. I have a templete sensor set up in HAAS to let me know if it's Washing, in Standby, or off, based upon the power consumption (Shelly 1PM on outlets)

- name: "Washing Machine" state: > {% if states("sensor.washer_switch_0_power")|float == 0 %} Off {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %} Standby {% else %} Washing {% endif %} icon: > {% if states("sensor.washer_switch_0_power") == "off" %} mdi:washing-machine-alert {% elif states("sensor.washer_switch_0_power")|float <= 2.9 %} mdi:washing-machine-off {% else %} mdi:washing-machine {% endif %} minutes: 2

The MSR code is relatively simple. I have a built in false positive attribute for if MSR gets rebooted, because I would suddenly get tons of notifications when I upgraded MSR.

6774565a-06cc-443f-99c1-e71301b33d83-image.png

What I'm trying to introduce, is a way to verify that I just didn't bump the knob on the washing machine when transferring loads from the washer to the dryer, which turns on the display and brings the power above the Standby threshold.

The power goes up to 3.7W for about 4 minutes if the selector knob is bumped/turned.

What would the best way to do this be? I have most of my MSR code set up for a couple of years now, and my coding logic is struggling a bit.

I think I need a power threshold to be substained for a minimum time period (say 2 or 3 minutes, above 10W), before the other triggers can act. What would the best way to do that be?

Running: latest-25082-3c348de6
Fedora 41 Server
HAAS:
Core
2025.3.4
Supervisor
2025.03.4
Operating System
15.1
Frontend
20250306.0

Multi-System Reactor
Reactor (Multi-System/Multi-Hub) Announcements
toggledbitsT

Build 21228 has been released. Docker images available from DockerHub as usual, and bare-metal packages here.

Home Assistant up to version 2021.8.6 supported; the online version of the manual will now state the current supported versions; Fix an error in OWMWeatherController that could cause it to stop updating; Unify the approach to entity filtering on all hub interface classes (controllers); this works for device entities only; it may be extended to other entities later; Improve error detail in messages for EzloController during auth phase; Add isRuleSet() and isRuleEnabled() functions to expressions extensions; Implement set action for lock and passage capabilities (makes them more easily scriptable in some cases); Fix a place in the UI where 24-hour time was not being displayed.
Multi-System Reactor
Deleting widgets
tunnusT

Hopefully a trivial question, but how do you delete widgets in a status page? Using build 22266

Multi-System Reactor
MQTT configuration question
tunnusT

I have the following yaml configuration in local_mqtt_devices file

x_mqtt_device: set_speed: arguments: speed: type: str topic: "command/%friendly_name%" payload: type: json expr: '{ "fan": parameters.speed }'

While this works fine, I'm wondering how this could be changed to "fixed" parameters, as in this case "fan" only accepts "A", "Q" or a numeric value of 1-5?

Multi-System Reactor
System Configuration Check - time is offset
F

Hi!

I get this message when I'm on the status tab:

System Configuration Check
The time on this system and on the Reactor host are significantly different. This may be due to incorrect system configuration on either or both. Please check the configuration of both systems. The host reports 2025-04-01T15:29:29.252Z; browser reports 2025-04-01T15:29:40.528Z; difference 11.276 seconds.

I have MSR installed as a docker on my Home Assistant Blue / Hardkernel ODROID-N2/N2+. MSR version is latest-25082-3c348de6.
HA versions are:
Core 2025.3.4
Supervisor 2025.03.4
Operating System 15.1

I have restarted HA as well as MSR multiple times. This message didn´t show two weeks ago. Don´t know if it have anything to do with the latest MSR version.
Do anyone know what I can try?
Thanks in advance!
Let's Be Careful Out There (Hill Street reference...) 🙂
/Fanan

Multi-System Reactor
Programmatically capture HTTP Request action status code or error
therealdbT

I have a very strange situation, where if InfluxDB restarts, other containers may fail when restarting at the same time (under not easy to understand circumstances), and InfluxDB remains unreachable (and these containers crashes). I need to reboot these containers in an exact order, after rebooting InfluxDB.

While I understand what's going on, I need a way to reliable determine that InfluxDB is not reachable and these containers are not reachable, in order to identify this situation and manually check what's going on - and, maybe, in the future, automatically restart them if needed.

So, I was looking at HTTP Request action, but I need to capture the HTTP response code, instead of the response (becase if ping is OK, InfluxDB will reply with a 204), and, potentially, a way to programmatically detect that it's failing to get the response.

While I could write a custom HTTP controller for this or a custom HTTP virtual device, I was wondering if this is somewhat on you roadmap @toggledbits

Thanks!

Multi-System Reactor
ZwaveJSUI - RGBWW BULB - Warm/Cold White interfered with RGB settings - Bulb doesn't change color if in WarmWhite state.
N

Hi ,
I'm on
-Reactor (Multi-hub) latest-25067-62e21a2d
-Docker on Synology NAS
-ZWaveJSUI 9.31.0.6c80945

Problem with ZwaveJSUI:
When I try to change color to a bulb RGBWW, it doesn't change to the RGB color and the bulb remains warm or cold white.
I tryed with Zipato RGBW Bulb V2 RGBWE2, Hank Bulb HKZW-RGB01, Aentec 6 A-ZWA002, so seems that it happens with all RGBWW bulb with reactor/zwavejsui.

I'm using from reator the entity action: "rgb_color.set" and "rgb_color.set_rgb".
After I send the reactor command, It changes in zwavejsui the rgb settings but doesn't put the white channel to "0", so the prevalent channel remains warm/cold White and the bulb doesn't change into the rgb color.

This is the status of the bulb in zwavejsui after "rgb_color.set" (235,33,33,) and the bulb is still warmWhite.

x_zwave_values.Color_Switch_currentColor={"warmWhite":204,"coldWhite":0,"red":235,"green":33,"blue":33}

The "cold white" and "warm white" settings interfer with the rgb color settings.

Reactor can change bulb colors with rgb_color set — (value, ui8, 0x000000 to 0xffffff) or rgb_color set_rgb — (red, green, blue, all ui1, 0 to 255) but if warm or cold white
are not to "0", zwavejsui doesn't change them and I can't find a way to change into rgb or from rgb back to warm white.

So if I use from reactor: rgb_color set_rgb — (235,33,33) in zwavejsui I have

x_zwave_values.Color_Switch_targetColor={"red":235,"green":33,"blue":33} 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: targetColor └─endpoint: 0 └─newValue └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──red: 235 └──green: 33 └──blue: 33 └─propertyName: targetColor 14/03/2025, 16:43:57 - value updated Arg 0: └─commandClassName: Color Switch └─commandClass: 51 └─property: currentColor └─endpoint: 0 └─newValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─prevValue └──warmWhite: 204 └──coldWhite: 0 └──red: 235 └──green: 33 └──blue: 33 └─propertyName: currentColor

In zwavejsui, the bulb changes rgb set but warm White remains to "204" and the bulb remais on warm White channel bacause is prevalent on rgb set.

x_zwave_values.Color_Switch_currentColor_0=204 x_zwave_values.Color_Switch_currentColor_1=0 x_zwave_values.Color_Switch_currentColor_2=235 x_zwave_values.Color_Switch_currentColor_3=33 x_zwave_values.Color_Switch_currentColor_4=33

Is it possible to targetColor also for "warmWhite" and "coldWhite" and have something similar to this?

x_zwave_values.Color_Switch_targetColor={"warmWhite":0,"coldWhite":0,"red":235,"green":33,"blue":33}

Thanks in advance.

Multi-System Reactor
Problem with simultaneous notifications.
T

Good day all,
I have a reaction set up, that I use for both troubleshooting and changing home modes when one of my family members either arrive or are leaving. I use the companion app for HAAS on our iPhones, and HAAS reports if the person associated with the iPhone enters or leaves the geofenced area around my home. I'm sure most MSR and HAAS users are familiar with this.

I use this rule set mainly as a condition for other rules, however, as part of troubleshooting, a notification is sent through HAAS to the companion app when the rule becomes true. The problem is that I'm getting notifications now for both arriving and departing simultaneously.

96b3f7db-ba09-499e-a78c-86903b603857-image.png

36903cdd-a87f-473b-82ef-af9ef96d3c44-image.png It used to work fine as intended. I'm not sure exactly when it changed, but now I'm getting two notifications when either of these conditions change.

Any idea what could be happening?

Edit:
Running: latest-25082-3c348de6, bare-metal Linux
ZWaveJSControllerr [0.1.25082]

Multi-System Reactor
Problem after upgrading to 25067
R

MSR had been running fine, but I decided to follow the message to upgrade to 25067. Since the upgrade, I have received the message "Controller "<name>" (HubitatController hubitat2) could not be loaded at startup. Its ID is not unique." MSR throws the message on every restart. Has anyone else encountered this problem?
I am running MSR on a Raspberry Pi4 connecting to two Hubitat units over an OpenVPN tunnel. One C8 and a C8 Pro. Both are up-to-date. It appears that despite the error message that MSR may be operating properly.

Multi-System Reactor
Global expressions not always evaluated
tunnusT

Similarly as for local expressions, global expressions evaluate and update fine when getEntity(...) structure is used. However, at least when certain functions are in use, expressions do not update.

Consider the following test case:

Screenshot 2025-03-13 at 16.29.42.png

Even though auto-evaluation is active, value does not change (it changes only if that expression is manually run). MSR restarts do not help.

Screenshot 2025-03-13 at 16.31.43.png

Note: Tested using build 25067 on Docker. I have also a PR open (but couldn't now get details or PR number as my Mantis account was somehow expired?).

Multi-System Reactor
[Solved] Local expression evaluation
V

Trying to understand what cause a local expresssion to be evaluated. I have read the manual but I am still not clear about it. Using the test rule below, I can see in the log that the rule is being automatically evaluated every time the temperature entity is changing. That is great...

What I am trying to understand is why the expression is not evaluated based on time as well since the "case" statement has time dependencies.

Any help would be appreciated

I have the following test rule:

eba6a3ea-ff61-4610-88c9-9b9864f11ff8-Screenshot 2025-01-21 095244.png

2d9c1ff5-7b73-4005-b324-9029c2709db9-Screenshot 2025-01-21 095302.png

Here is the expressioncode:

vFrom1 = "09:25:00", vFrom2 = "09:30:00", vFrom3 = "09:41:00", vTo = "10:55:00", # Get current time (format HH:MM:SS) vToDay = strftime("%H:%M:%S"), #Get current house temperature CurrentHouseTemp = getEntity( "hass>Thermostat2 " ).attributes.temperature_sensor.value, case when CurrentHouseTemp <= 19 and vToDay >= vFrom1 && vToDay <= vTo: "true1" # From1 when CurrentHouseTemp <= 20 and vToDay >= vFrom2 && vToDay <= vTo: "true2" # From2 when CurrentHouseTemp < 26  and vToDay >= vFrom3 && vToDay <= vTo: "true3" # From3 else "false" end
Multi-System Reactor
[Solved] Runtime error when exiting global reaction that contains a group
S

I am getting a Runtime error on different browsers when I click exit when editing an existing or creating a new global reaction containing a group. If the global reaction does not have a group I don't get an error. I see a similar post on the forum about a Runtime Error when creating reactions but started a new thread as that appears to be solved.

The Runtime Error is different in the two browsers
Safari v18.3

@http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:44 You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.

Google Chrome 133.0.6943.142

TypeError: self.editor.isModified is not a function at HTMLButtonElement.<anonymous> (http://192.168.10.21:8111/reactor/en-US/lib/js/reaction-list.js:171:34) You may report this error, but do not screen shot it. Copy-paste the complete text. Remember to include a description of the operation you were performing in as much detail as possible. Report using the Reactor Bug Tracker (in your left navigation) or at the SmartHome Community.

Steps to reproduce:
Click the pencil to edit a global reaction with a group.
Click the Exit button.
Runtime error appears.
or
Click Create Reaction
Click Add Action
Select Group
Add Condition such as Entity Attribute.
Add an Action.
Click Save
Click Exit
Runtime error appears.

I don’t know how long the error has been there as I haven’t edited the global reaction in a long time.

Reactor (Multi-hub) latest-25060-f32eaa46
Docker
Mac OS: 15.3.1
Thanks

Multi-System Reactor
Cannot delete Global Expressions
SnowmanS

I am trying to delete a global expression (gLightDelay) but for some strange reason, it comes back despite clicking the Delete this expression and Save Changes buttons.

I have not created a global expression for some times and just noticed this while doing some clean-up.

I have upgraded Reactor to 25067 from 25060 and the behaviour is still there. I have restarted Reactor (as well as restarting its container) and cleared the browser's cache several times without success.

Here's what the log shows.

[latest-25067]2025-03-08T23:50:22.690Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" } [latest-25067]2025-03-08T23:50:26.254Z <GlobalExpression:NOTICE> Deleting global expression gLightDelay [latest-25067]2025-03-08T23:50:27.887Z <wsapi:INFO> [WSAPI]wsapi#1 rpc_echo [Object]{ "comment": "UI activity" }

Reactor latest-25067-62e21a2d
Docker on Synology NAS

Multi-System Reactor
Advice on Storing and Backing Up Bind Mounts - Docker
PablaP

Hello all, after seeing Catman's posts about their disaster recovery and move to Docker I took that as a sign to migrate everything (aside from HA) to Docker. After a small learning curve I had Docker+Portainer up and running in a few days.

Instead of using named Volumes I opted to use Bind Mounts so I can easily edit conf files and any other file needed. I do understand the nuances that come with bind mounts, such as migration to a different host may require changing file structures, the possibility of someone editing the bind mount files and permissions but to me those aren't too big of a deal.

My question is what is the best way to keep a back up of these bind mounts? I currently have them stored in the /etc directory in another directory named on a per container basis. I was thinking to move it all to a /home/user/docker/ directory so that I can use a simple cp command to my mounted SMB share to backup all the container data files. Anyone else do it differently?

Side note: I finally got to flex the benefits of Docker with updating Reactor.. it was dead simple. I had no idea what I was missing out on lol!

Software
Local notification methods?
CatmanV2C

Morning, experts. Hard on learning about the internet check script in MSR tools, I was wondering what suggestions anyone has about a local (i.e. non-internet dependent) notification method.

This was prompted by yesterday's fun and games with my ISP.

I've got the script Cronned and working properly but short of flashing a light on and off, I'm struggling to think of a way of alerting me (ideally to my phone)

I guess I could set up a Discord server at home, but that feels like overkill for a rare occasion. Any other suggestions?

TIA

C

Multi-System Reactor
About
Posts
88
Topics
13
Groups
0
Followers
0
Following
1

Posts

Recent Best Controversial

  • My Turn! Suspended at Ezlo Forum
    M Matteburk

    My turn now... Shit Ezlo CEO is really on slipper ice.

    I sak that in the thread that someone has contacted his wife and is Boeing concerened about his behavior.

    When you read the mail you clearly read that its someone close to him at the Company...

    Sad that he is ruining his Company and allt of peoples Jobs at risk.

    /M


  • Can't see VeraPlus and Hubitat (config question)
    M Matteburk

    Ok.... here we go! All hubs online in MSR :). ,Vera Plus and HUBITAT!..... Thanx for the help!..... Lets test!


  • Vera account suspended for a 1000 years
    M Matteburk

    And the winner in the right corner of last nights MMA Forum Fight is .......Riiiiiiiiiiiiigpapaaaaa.......🤪

    So Sad that the other guy cant accept his limits. You cant act as a CEO on a companyforum like you were just an annoying user. If he had stayed off the forum and let Nice guys like Sorin and the others do the talkng i guess the hole forumclimate would be better and ezlo more successful.
    Good that you stand up and Don’t let bad People push you down @toggledbits


  • Preview of Multi-System Reactor
    M Matteburk

    @toggledbits On 21075 now and it works (button found) 🙂 Thanx! Lets rock on!


  • Vera account suspended for a 1000 years
    M Matteburk

    Maybe I should sell my 3d printed ezlo Plus shell on Ebay along with the ezlo plus hardware .... Shell 20 Dollar, Hardware Free .... hahaha


  • Water level sensor
    M Matteburk

    I am building a infinityppool to a customer and I use a Pressure-type level sensor #12086 https://www.youtube.com/watch?v=DCe_wYQ_BC0

    admin

    ASIN AQUA Home en - Aseko Pool Technology

    ASIN AQUA Home en - Aseko Pool Technology

    DOSING Systems CONTROL Systems Aseko PROBES DOSING Pumps ASIN AQUA Home POOL WATER TREATMENT & POOL TECHNOLOGY MANAGEMENT ASIN AQUA Home The luxury unit with most advanced water treatment features and intelligent system control functions. Exclusive stainless-steel case with peristaltic pumps....


  • Easy way to convert to SSD from SD card on Pi with MSR
    M Matteburk

    FYI I got the RPi 4 with ssd up and running and cloned sd card . Thanx to all!


  • How do I "else"
    M Matteburk

    MSR is a bit different then the Reactor.

    Trigger :
    A changes
    Constraints :
    A is true
    Reaction:
    Close window shade

    How do i " Else if A is false ! then Open shades
    ??

    In old reactor it was easy but cant get it with msr....

    /Mattias


  • Shelly i3 as a cheap scene controller for Openluup
    M Matteburk

    I gave up Vera 5 month ago to Hubitat and I Have discovered Shelly. Fast and easy. I sold all my fibaro dimmers and switches... The only device that doesn't have a Hubitat driver now is Uni.. so smart implant still runs... But they work good. The Shellys is almost for free compared to zwave products.....


  • System integration roadmap
    M Matteburk

    Reolink Cameras with NVR ... would be lovely to trigger stuff with....


  • Preview of Multi-System Reactor
    M Matteburk

    @toggledbits
    Could you share a rule for one Room so we can see how it could look like with multipel reactions that has different conditions.
    I Don’t really understand how multipel reactions on diffrent conditions should look like. In Reactor it was easy to understand but in msr i Don’t get it..

    I really Wanja make more complicated automations but Iam stuck with one reaction...
    / Mattias


  • Preview of Multi-System Reactor
    M Matteburk

    @toggledbits Like Christmas for a kid the search entity function just popped up over night,when I woke up in a crispy Sunny Sweden it just was there.... Super great work P!


  • Can someone explain for me how to use Reset reaction in MSR without disturbing other rules.
    M Matteburk

    @librasun that is what I have done in this case. but still didn't work anyway...... lets hope this update sort it up...


  • Feature Request: MSR Rule Snapshot Exporter
    M Matteburk

    Sounds good..... Then the MSR could have a section: Rule example templates


  • Current Alert Tasks
    M Matteburk

    Aha... se the log it says 😁


  • Entitys coming back
    M Matteburk

    ahh, correct wort is Reset , the yellow botton. I save and then go back and reset the rule. I fwill ix a PR for P


  • Version 1.0 Pre-release Discussion
    M Matteburk

    Feature requests .. Now when we have groups in set reactions and reset reactions it would be nice if they showed up in the the visual tree under trigger and conditions.
    Then you have a more visual overview of the hole logic. /Mattias


  • Updated to latest MSR 21243 and no entities are being executed I Hubitat
    M Matteburk

    @toggledbits

    Big thanx again Patrick!
    Keep up the good work!!

    Now bedtime in Sweden!

    /Mattias


  • Hubitat and virtual devices
    M Matteburk

    @toggledbits Yes it is but its just to toggle all off and then on so it goes quite fast.. But in Hubitat dashboard its the same thing. Because if you have all devices enabled for a dashboard it loads slower. Then they have made it so you can enable the ones you want in a dashboard. This really sucks when you make dashboard with a lot of specific devices.

  • Login